• Title/Summary/Keyword: Hydraulic Leakage

Search Result 209, Processing Time 0.025 seconds

The Method of Certificating Waterproof Effect for Consecutive Column-Wall Mass in Underground (주열식 지중연속벽체의 차수효과 확인 방안)

  • Koh, Yong-IL
    • Journal of the Korean GEO-environmental Society
    • /
    • v.18 no.9
    • /
    • pp.5-9
    • /
    • 2017
  • On the flow of groundwater, the effect of consecutive column-wall in underground as a hydraulic barrier could be identified by conventional geotechnical methods ((1)visualiy identification of wall mass after underground excavating, (2)uniaxial compressive strength test for core of wall mass in underground, (3)in-situ permeability test in the hole after coring wall mass). However, for the cut off the leakage or infiltration of very high concentrated leachate from the waste landfill or the contaminated groundwater, the waterproof effect of consecutive column-wall in underground should be verified more objectively, by in-situ measuring of pH, temperature and salinity. and by evaluating of their consistency and similarity throughout analyzing the characteristics of basic components and their profiles through the series of chemical experiments. Furthermore, its waterproof effect could be verified additionally throughout deciding the similarity more simply by comparing the general distribution patterns including the difference of high and low peaks from the chromatograms using GC-MS for surrounding groundwater.

Proper Regulation of the Cutoff System in Offshore Landfill Built on Clay Ground with Double Walls (점토지반에 이중벽체가 적용된 해상폐기물매립장의 적정 차수 기준)

  • Hwang, Woong-Ki;Kim, Hyang-Eun;Choi, Hoseong;Kim, Tae-Hyung
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.8
    • /
    • pp.5-15
    • /
    • 2019
  • This study was conducted to propose a reasonable requirement regulation of cutoff barriers composed of bottom layer and vertical barrier of offshore landfill for the prevention of contaminant leakage. The bottom layer was composed of impermeable clay layer; vertical walls were composed of double walls; outer wall was composed of steel sheet pile which registed against outer force; cutoff vertical barrier took the role of inner wall. Seepage-advection-dispersion numerical analysis was conducted using SEEP/W and CTRAN/W programs under steady and unsteady flows. The results showed that the values calculated under steady flow showed higher migration of pollutant than those of unsteady flow. The values calculated under steady flow are more valid from a design point of view. Under steady flow and the bottom clay layer and when the vertical barrier are homogeneous and completely well installed, respectively, the minimum required cutoff regulations for hydraulic conductivity, thickness, and embedded depth of the bottom clay layer and vertical barrier were suggested.

A Study on the Applicaton of Electrical Resistivity Survey in the Contaminated Soil and Groundwater Site (토양 및 지하수 오염지역에 대한 전기비저항탐사의 적용성 연구)

  • Chae, Seungheon;Lee, Sangeun;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.30 no.4
    • /
    • pp.525-539
    • /
    • 2020
  • A site containing buried solid waste and treated water and oil storage containers from a leather manufacturing plant was studied through soil and groundwater pollution and electrical resistivity surveys with the aim of identifying areas polluted by leachate generated by landfilling with leather waste and leakage wastewater. It was found that TPH and Zn exceeded environmental standards for soil pollution and, for leachate and groundwater, Cr(VI) concentrations exceeded standard levels for groundwater quality. An electrical resistivity survey was used to elucidate soil and groundwater pollution characteristics and diffusion pathways. Ten survey lines were set up with an electrode spacing of 5 m in a dipole-dipole array. The hydraulic characteristics of soil determined by groundwater contamination surveys matched well the low-resistivity-anomaly zones. Electrical resistivity surveys of areas containing contaminated soil and groundwater that have irregular strata due to waste reclamation are thus useful in highlighting vertical and horizontal pollutant diffusion pathways and in monitoring contaminated and potentially contaminated areas.

Applications of Improved Low-Flow Mortar Type Grouting Method for Road Safety and Constructability in Dangerous Steep Slopes (급경사지 붕괴 위험지역의 도로 안전 및 시공성을 고려한 개선된 저유동 몰탈형 그라우팅공법 적용성 분석)

  • Choi, Gisung;Kim, Seokhyun;Kim, Nakseok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.40 no.4
    • /
    • pp.409-415
    • /
    • 2020
  • Low-flow mortar injection method grouting technology was selected and the traffic area was preserved as much as possible in order to secure safety for road traffic when the outflow and subsidence of landfill occurred due to ground-water, and etc. In particular, the current existing method was newly improved since there are risks of damage such as hydraulic fracturing at the lower part of the road, spilling of soil particles on steep slopes, and bumps on the road due to excessive injection pressure during construction. This study was carried out at the site of reinforcement work on the road as a maintenance work for the danger zone for collapse of the steep slope of the 00 hill, which was ordered from the 00 city 00 province. The improved low-flow mortar type grouting method adopted a new automated grouting management system and especially, it composites the method for grouting conditions decision by high-pressure pre-grouting test and injection technology by AGS-controlled and studied about grouting effect analysis by using new technology. By applying the improved low-flow mortar type grouting method, it was possible to lay the groundwork for road maintenance work such as the prevention of subsidence of old roads, uneven subsidence of buildings and civil engineering structures, and of soil leakage of ground-water spills. Furthermore, the possibility of application on future grouting work not only for just construction that prevents subsidence of old roads but also for various buildings and civil engineering structures such as railroads, subways, bridges, underground structures, and boulder stone and limestone areas was confirmed.

A Study for Lifespan Prediction of Expansion by Temperature Status (온도상태에 따른 신축관 이음의 수명예측에 관한 연구)

  • Oh, Jung-Soo;Lee, Bong-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.10
    • /
    • pp.424-429
    • /
    • 2018
  • In this study, an expansion joint that is susceptible to waterhammer was tested for its vibration durability. The operation data for the hydraulic actuator was the expansion length of the expansion joint when the waterhammer occurred. In the case of the vibration durability test, the internal temperature status of the expansion joint was assumed to be a stress factor and a lifespan prediction model was assumed to follow the Arrhenius model. A test was carried out by increasing the internal temperature status at $30^{\circ}C$, $50^{\circ}C$, and $65^{\circ}C$. By a linear transformation of the lifespan data for each temperature, a constant value and activation energy coefficient was induced for the Arrhenius equation and verified by comparing the value of a lifetime prediction model with the experimental value at $85^{\circ}C$. The failure modes of the ongoing or finished test were leakage, bellows separation, and internal deformation. In the future, a composite lifespan prediction model, including two more stress factors, will be developed.

Site Investigation for Pilot Scale $CO_2$ Sequestration by Magnetotelluric Surveys in Uiseong, Korea (이산화탄소 지중저장 Pilot 부지 선정을 위한 의성지역 MT 탐사)

  • Lee, Tae-Jong;Han, Nu-Ree;Ko, Kwang-Beom;Hwang, Se-Ho;Park, Kwon-Gyu;Kim, Hyung-Chan;Park, Yong-Chan
    • Geophysics and Geophysical Exploration
    • /
    • v.12 no.4
    • /
    • pp.299-308
    • /
    • 2009
  • A magentotelluric (MT) survey at the Uiseong area has been performed for the site investigation of pilot scale $CO_2$ sequestration. The purpose of the MT survey is to delineate deeply extended fracture systems that can act as a leakage path of injected $CO_2$ Plume. Since the target area is extremely noisy in electromagentic sense, low frequency data below 1 Hz cannot be used for inversion. Two- and three-dimensional interpretation of the MT data showed a very clear conductive anomaly, which has the direction of $N55\sim65^{\circ}W$ and is extended roughly down to 1.6 km. It have the same direction with the strike-slip faults, the Gaeum and Geumcheon Faults. On the contrary, the eastern part of the survey area shows relatively homogeneous to the depth of 2 km though some small fractures at shallow depths can be found. Test drilling and high-definition borehole surveys should be followed at the eastern part of the survey area and hydraulic fracturing is required for injection of $CO_2$, because mean porosity of the sedimetary rock in the area is only 1.47%.

A Study on the Rainfall Infiltration Capacity of Soil (A Study on the Mid-Mountain Area of Jeju Island) (강우의 토양 침투 투수성 연구(제주도 중산간 지역을 중심으로))

  • Jeon, Byeong Chu;Lee, Su Gon;Kim, Sung Soo;Kim, Ki Su;Kim, Nam Ju
    • The Journal of Engineering Geology
    • /
    • v.29 no.2
    • /
    • pp.99-112
    • /
    • 2019
  • Rainfall infiltration through the unsaturated zone is influenced by a range of factors including topography, geology, soil, rainfall intensity, temperature and vegetation; the actual infiltration varies largely in time and space. The infiltration capacity of soil is a critical factor in identifying groundwater recharge and leakage of surface water. It may differ depending on soil types and geological features of a particular basin or territory as well as on the usage of the land. This study was conducted in forest and farmland region of the mid-mountain area (EL. 50~300 m) of Jeju Island to test soil infiltration capacity of the area where rainfall contributes to groundwater. Results were analyzed using the four soil group classification methods presented by Jeong et al. (1995) and NAS (2007) to discover that the method offered by NAS (2007) is more reliable in the mid-mountain area of Jeju Island. The study compares and reviews the existing classification methods using the results of infiltration capacity tests executed on different soil groups throughout the whole region of the Jeju mid-mountain area. It is expected that this work will serve as a guideline for evaluating surface water recharge and hydraulic characteristics of Jeju Island.

Effect of Viscosity and Clogging on Grout Penetration Characteristics (점도 변화와 폐색 현상을 고려한 그라우트재의 침투 특성)

  • Kim, Jong-Sun;Choi, Yong-Ki;Park, Jong-Ho;Woo, Sang-Baik;Lee, In-Mo
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.4
    • /
    • pp.5-13
    • /
    • 2007
  • Many construction projects adopt grouting technology to prevent the leakage of groundwater or to improve the shear strength of the ground. Recognition as a feasible field procedure dates back to 1925. Since then, developments and field use have increased rapidly. According to improvement of grout materials, theoretical study on grout penetration characteristics is demanded. Fluid of grout always tends to flow from higher hydraulic potential to lower one and the motion of grout is also a function of formation permeability. Viscosity of pout is changed by chemical action while grout moves through pores. Due to the increment of viscosity, permeability is decreased. Permeability is also reduced by grout particle deposits to the soil aggregates. In this paper, characteristics of new cement grout material that has been developed recently are studied: injectable volume of new grout material is tested in two different grain sizes of sands; and the method to calculate injectable volume of grout Is suggested with consideration of change in viscosity and clogging phenomena. The calculated values are compared with injection test results. Viscosity of new grout material is found to increase as an exponential function of time. And lumped parameter $\delta$ of new grout material to be used for assessing deposition characteristics is estimated by comparing deposit theory with injection test results considering different soil types and different injection pressures. Injection test results show that grout penetration rate is decreased by the increase of grout viscosity and clogging phenomena.

A Review Study on Major Factors Influencing Chlorine Disappearances in Water Storage Tanks (저수조 내 잔류염소 감소에 미치는 주요 영향 인자에 관한 문헌연구)

  • Noh, Yoorae;Kim, Sang-Hyo;Choi, Sung-Uk;Park, Joonhong
    • Journal of Korean Society of Disaster and Security
    • /
    • v.9 no.2
    • /
    • pp.63-75
    • /
    • 2016
  • For safe water supply, residual chlorine has to be maintained in tap-water above a certain level from drinking water treatment plants to the final tap-water end-point. However, according to the current literature, approximately 30-60% of residual chlorine is being lost during the whole water supply pathways. The losses of residual chlorine may have been attributed to the current tendency for water supply managers to reduce chlorine dosage in drinking water treatment plants, aqueous phase decomposition of residual chlorine in supply pipes, accelerated chlorine decomposition at a high temperature during summer, leakage or losses of residual chlorine from old water supply pipes, and disappearances of residual chlorine in water storage tanks. Because of these, it is difficult to rule out the possibility that residual chlorine concentrations become lower than a regulatory level. In addition, it is concerned that the regulatory satisfaction of residual chlorine in water storage tanks can not always be guaranteed by using the current design method in which only storage capacity and/or hydraulic retention time are simply used as design factors, without considering other physico-chemical processes involved in chlorine disappearances in water storage tank. To circumvent the limitations of the current design method, mathematical models for aqueous chlorine decomposition, sorption of chlorine into wall surface, and mass-transfer into air-phase via evaporation were selected from literature, and residual chlorine reduction behavior in water storage tanks was numerically simulated. The model simulation revealed that the major factors influencing residual chlorine disappearances in water storage tanks are the water quality (organic pollutant concentration) of tap-water entering into a storage tank, the hydraulic dispersion developed by inflow of tap-water into a water storage tank, and sorption capacity onto the wall of a water storage tank. The findings from his work provide useful information in developing novel design and technology for minimizing residual chlorine disappearances in water storage tanks.