• 제목/요약/키워드: Hybrid stud

검색결과 22건 처리시간 0.017초

복합스터드에 경량기포모르터를 충전한 내력벽체의 내화성능 비교연구 (Fire Resistance Performance of Load Bearing Hybrid Panel Infilled with Light-weight Formed Mortar)

  • 박금성;배규웅;강현식;임서형
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제11권2호
    • /
    • pp.109-116
    • /
    • 2007
  • 본 논문의 목적은 경량기포모르터를 충전한 스틸스터드와 복합스터드 내력벽체의 내화성능을 KS규준에 따라 평가하는데 있다. 주거용과 상업용 건물의 최소 내화 요구시간은 2시간이다. 시험 결과로부터 스틸 스터드와 복합스터드에 경량기포 모르터를 충전한 두 시험체 모두 2시간 내화 성능을 만족하는 것으로 나타났다. 또한 복합스터드 패널 시험체의 경우 내화 성능면에서 스틸 스터드 패널 시험체 보다 우수하다는 것을 정량적 평가하였다.

Experimental study on the hybrid shear connection using headed studs and steel plates

  • Baek, Jang-Woon;Yang, Hyeon-Keun;Park, Hong-Gun;Eom, Tae-Sung;Hwang, Hyeon-Jong
    • Steel and Composite Structures
    • /
    • 제37권6호
    • /
    • pp.649-662
    • /
    • 2020
  • Although several types of rigid shear connectors have been developed particularly to increase load-carrying capacity, application is limited due to the complicated details of such connection. In this study, push-out tests were performed for specimens with hybrid shear connectors using headed studs and shear plates to identify the effects of each parameter on the structural performance of such shear connection. The test parameters included steel ratios of headed stud to shear plate, connection length, and embedded depth of shear plates. The peak strength and residual strength were estimated using various shear transfer mechanisms such as stud shear, concrete bearing, and shear friction. The hybrid shear connectors using shear plates and headed studs showed large load-carrying capacity and deformation capacity. The peak strength was predicted by the concrete bearing strength of the shear plates. The residual strength was sufficiently predicted by the stud shear strength of headed studs or by shear friction strength of dowel reinforcing bars. Further, the finite element analysis was performed to verify the shear transfer mechanism of the connection with hybrid shear connector.

복합스터드의 압축 좌굴 거동 (Behavior of Hybrid Stud under Compressive Load)

  • 이상섭;배규웅
    • 한국강구조학회 논문집
    • /
    • 제16권5호통권72호
    • /
    • pp.609-619
    • /
    • 2004
  • 유럽을 중심으로 스틸스터드의 약점으로 지목 받고 있는 열교현상을 억제하기 위한 스터드 개선 연구가 활발히 진행되고 있다. 이 연구는 크게 마감재와 접촉 면적을 줄이는 방법, 웨브면에서 열전달 경로를 늘이는 방법, 열전도성이 낮은 소재를 사용하는 방법, 그리고 스터드를 피복하는 방법으로 구분할 수 있다. 비교적 저층의 주거용 건축물을 대상으로 하는 국외의 경우 에너지 소비에 초점이 맞춰져 있지만, 본 연구의 경우 중층화를 대비하여 구조적 성능도 고려하여 아연도금강판(SGC58)과 FRP를 에폭시로 부착하여 150SL 형태의 복합스터드를 개발하였다. 복합스터드의 소재로는 두께 1.0mm과 1.2mm 강판과 두께 4mm(4ply), 6mm(6ply)의 FRP를 적용하였고, 4가지의 접합 상세에 대한 제작 및 실험을 통해 최종적으로 우수한 결과를 보인 2가지를 선택하였다. 이와 같은 과정을 거쳐 개발된 복합스터드의 압축 성능을 확인하기 위해 2가지 접합 상세에 대해 단면 높이인 150mm에 대해 3, 6, 9, 12배 길이에 대해 압축 실험을 계획하였고, 기존 스틸 스터드와 비교하기 위하여 동일 형태의 비교 실험체도 제작하였다. 실험결과, 복합스터드의 최대하중은 강판 두께 1.0mm인 경우 동일 두께의 스틸 스터드보다 평균 1.62배, 1.2mm인 경우 평균 1.46배 증가하였으며, 가력 종료 시점에 이르기까지 일체 거동을 보여 구조적으로 우수함이 입증되었다.

복합구조 교량 적용을 위한 접합부 거동 실험 (An Experiment of Joint Behavior for the Application of Hybrid Bridges)

  • 유성원;서정인;김광수;정광회;심정욱;구동길
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.774-777
    • /
    • 2004
  • This study was performed to evaluate joint behavior for the application of hybrid bridges by experiment of 14 beams according to penetration length, amount of reinforcing steel and stud and prestressing stress. By tests results, prestressing stress was more effective than amount of stud or reinforcing steel. And the spacing of stud is also more effective than penetration length. Especially, all beams were failed by turns desertion of reinforcing steel, stud, and steel plate.

  • PDF

기존 학교건물 골조와 내진보강요소 일체화를 위한 변형경화형 시멘트 복합체를 적용한 스터드 전단 접합부의 구조성능 (Structural Performance of Stud Shear Connections using SHCC between Existing School Building Frame and Seismic Retrofitting Elements)

  • 김성호;윤현도
    • 교육시설 논문지
    • /
    • 제20권4호
    • /
    • pp.35-43
    • /
    • 2013
  • Some results of experimental investigation conducted to assess the effect of cement composite strength and ductility on the shear behavior and crack-damage mitigation of stud connections between existing reinforced concrete frame in school buildings and seismic strengthening elements from cyclically direct shear tests are described. The cement composite strengths include 50 for medium strength and 70 MPa for high strength. Two types of cement composites, strain-hardening cement composite (SHCC) and non-shrinkage mortar, are used for stud shear connection specimens. The special SHCCs are reinforced with hybrid 0.2% polyethylene (PE) and 1.3% polyvinyl alcohol (PVA) fibers at the volume fraction and exhibits tensile strain capacity ranging from 0.2 to 0.5%. Test result indicates that SHCC improves the seismic performance and crack-damage mitigation of stud shear connections compared with stud connections with non-shrinkage mortar. However, the performance enhancement in SHCC stud connections with transverse and longitudinal reinforcements is less notable for those without additional reinforcement.

Static and fatigue performance of stud shear connector in steel fiber reinforced concrete

  • Xu, Chen;Su, Qingtian;Masuya, Hiroshi
    • Steel and Composite Structures
    • /
    • 제24권4호
    • /
    • pp.467-479
    • /
    • 2017
  • The stud is one of the most frequently used shear connectors which are important to the steel-concrete composite action. The static and fatigue behavior of stud in the steel fiber reinforced concrete (SFRC) were particularly concerned in this study through the push-out tests and analysis. It was for the purpose of investigating and explaining a tendency proposed by the current existing researches that the SFRC may ameliorate the shear connector's mechanical performance, and thus contributing to the corresponding design practice. There were 20 test specimens in the tests and 8 models in the analysis. According to the test and analysis results, the SFRC had an obvious effect of restraining the concrete damage and improving the stud static performance when the compressive strength of the host concrete was relatively low. As to the fatigue aspect, the steel fibers in concrete also tended to improve the stud fatigue life, and the favorable tensile performance of SFRC may be the main reason. But such effect was found to vary with the fatigue load range. Moreover, the static and fatigue test results were compared with several design codes. Particularly, the fatigue life estimation of Eurocode 4 appeared to be less conservative than that of AASHTO, and to have higher safety redundancy than that of JSCE hybrid structure guideline.

Numerical analysis of large stud shear connector embedded in HFRC

  • He, Yu Liang;Zhang, Chong;Wang, Li Chao;Yang, Ying;Xiang, Yi Qiang
    • Structural Engineering and Mechanics
    • /
    • 제80권5호
    • /
    • pp.595-608
    • /
    • 2021
  • To investigate the mechanical behavior of large stud shear connector embedded in hybrid fiber-reinforced concrete (HFRC), a refined 3D nonlinear finite element (FE) model incorporating the constitutive model of HFRC was developed using ANSYS. Firstly, the test results conducted by the authors (He et al. 2017) were used to validate FE model of push out tests. Secondly, a total of 27 specimens were analyzed with various parameters including fiber volume fractions of HFRC, diameter of studs and HFRC strength. Finally, an empirical equation considering the contribution of steel fiber (SF) and polypropylene fiber (PF) was recommended to estimate the ultimate capacity of large stud shear connector embedded in HFRC.

Mechanical behavior of stud shear connectors embedded in HFRC

  • He, Yu-Liang;Wu, Xu-Dong;Xiang, Yi-Qiang;Wang, Yu-Hang;Liu, Li-Si;He, Zhi-Hai
    • Steel and Composite Structures
    • /
    • 제24권2호
    • /
    • pp.177-189
    • /
    • 2017
  • Hybrid-fiber reinforced concrete (HFRC) may provide much higher tensile and flexural strengths, tensile ductility, and flexural toughness than normal concrete (NC). HFRC slab has outstanding advantages for use as a composite bridge potential deck slab owing to higher tensile strength, ductility and crack resistance. However, there is little information on shear connector associated with HFRC slabs. To investigate the mechanical behavior of the stud shear connectors embedded in HFRC slab, 14 push-out tests (five batches) in HFRC and NC were conducted. It was found that the stud shear connector embedded in HFRC had a better ductility, higher stiffness and a slightly larger shear bearing capacity than those in NC. The experimentally obtained ultimate resistances of the stud shear connectors were also compared against the equations provided by GB50017 2003, ACI 318-112011, AISC 2011, AASHTO LRFD 2010, PCI 2004, and EN 1994-1-1 (2004), and an empirical equation to predict the ultimate shear connector resistance considering the effect of the HFRC slabs was proposed and validated by the experimental data. Curve fitting was performed to find fitting parameters for all tested specimens and idealized load-slip models were obtained for the specimens with HFRC slabs.

프리스트레스트 콘크리트-강 혼합거더의 휨 실험 및 경계면 수평계수 분석 (Flexural Experiment of PSC-Steel Mixed Girders and Evaluation for Analyses on Tangentional Stiffness of Connection)

  • 김광수;정광회;심정욱;유성원
    • 콘크리트학회논문집
    • /
    • 제20권2호
    • /
    • pp.231-237
    • /
    • 2008
  • 복합 구조 형식인 PSC-강 혼합 거더는 신형식 구조로서 비대칭 경간 구조물이나 장대교량에 적용될 수 있다. 본 연구에서는 매입길이, 보강철근, 스터드, 프리스트레스 힘 등을 변수로 총 14개의 실험체를 제작하여 혼합 거더의 접합부 거동을 분석하고자 하였다. 모든 실험체는 보강철근, 스터드, 강판 등의 순서로 기능을 손실하면서 파괴되었다. 실험 결과에 의하면 접합부의 성능에는 스터드 배치와 보강철근에 비해 프리스트레싱 힘이 상대적으로 큰 영향을 미치는 것으로 분석되었다. 이와 함께 매입길이에 비하여 스터드의 배치가 접합부 성능에 보다 중요한 역할을 하는 것으로 평가되었다. 실험적 연구와 함께 슬립을 고려한 3차원 비선형해석을 수행하였다. 경계면의 거동은 인터페이스 요소와 슬립 물성을 통하여 완전 합성, 부분합성, 비합성으로 분석할 수 있는데 혼합 거더의 접합부 설계에 따른 경계면 거동을 해석과 실험 결과를 통하여 분석하였다. 특히, 스터드 전단연결재가 적용된 혼합 거더는 극한하중 단계에서 부분합성 거동을 나타내며 보강 철근 또한 혼합 거더의 극한강도 증진에 기여하는 것으로 분석되었다.

압축과 비틂을 동시에 받는 복합스터드의 구조적 성능에 관한 연구 (A Study on the Structural Performance of Hybrid Studs Subjected to Compression and Torsion)

  • 정윤진;권영봉;곽명근;배규웅
    • 한국강구조학회 논문집
    • /
    • 제18권5호
    • /
    • pp.543-551
    • /
    • 2006
  • 최근까지 벽식 스틸하우스에 구조재로 주로 적용되어오고 있는 박판냉간성형형강 스터드의 경우 열교현상에 의한 단열상의 문제를가지고 있기 때문에 추가적인 단열재를 사용하여야 한다. 이러한 문제를 해결하기 위한 새로운 개념의 아연도금강판(t =1.0mm-1.2mm)과 난연 강화플라스틱(GFRP) 패널 (t=4.0mm-6.0mm)로 구성된 복합스터드가 개발되었다. 복합스터드 패널을 주택 에 적용하기 위하여, 복합스터드의 구조적인 거동 및 내하력 평가를 수행하였다. 본 논문에서는 ATTM(Axial/Torsional Test machine)을 이용하여 수행된 압축력과 비틂을 동시에 받는 복합스터드의 실험적인 연구결과를 기술하였다. 압축-비틂 실험의 주요 변수는 복합스터드의 길이, 초기 압축력, 가력방법 등이며, 초기 압축력을 일정하게 유지한 상태에서 스터드 시험체가 종국적인 파괴에 이르도록 비틂 하중을 점차 증가시키는 방법으로 실험을 수행하였다. 또한 고강도 아연도금강판과 GFRP의 기계적인 특성을 고려한 비선형 유한요소해석을 수행하여 실험결과와 비교, 검증하였다.