• Title/Summary/Keyword: Hybrid materials

Search Result 1,846, Processing Time 0.03 seconds

Preliminary Experimental Study for Water Recovery and Particulate Matter Reduction through a Hybrid System that Combines Exhaust Cooling and Absorption from Ships (선박배출 배기냉각과 흡수식이 결합된 하이브리드 시스템을 통한 물 회수 및 미세먼지 저감을 위한 기초실험연구)

  • Youngmin Kim;Donggil Shin;Younghyun Ryu
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.7
    • /
    • pp.1252-1258
    • /
    • 2022
  • The exhaust gas from the marine engines include a quantity of water vapor and particulate matter. The total particulate matter includes filterable particulate matter (FPM) and condensable particulate matter (CPM) that condense after releasing into the atmosphere. The portion of CPM is higher than that of FPM that is removable through the filter before discharging. An experimental setup for waste heat and water recovery and removal of CPM in the exhaust gas was tested using an industrial gas boiler in the laboratory. The water and CPM in the exhaust gas were removed through the first stage of cooling method and further removed through the second stage of absorption method. The efficiencies of water recovery were 73% after the first stage of cooling method and 90% after the second stage of absorption method. At the same time, the CPM was removed by 80-90% through the processes. The waste heat recovered could be used to process heat, and the water recovered could be used to process water in the ship. Furthermore, the CPM, which is a major source of the particulate matter but not subject to administrative regulation, could be removed effectively.

Structural change and electrical conductivity according to Sr content in Cu-doped LSM (La1-xSrxMn0.8Cu0.2O3) (Sr 함량이 Cu-doped LSM(La1-xSrxMn0.8Cu0.2O3)의 구조적변화와 전기전도도에 미치는 영향)

  • Ryu, Ji-Seung;Noh, Tai-Min;Kim, Jin-Seong;Lee, Hee-Soo
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.22 no.2
    • /
    • pp.78-83
    • /
    • 2012
  • The structural change and the electrical conductivity with Sr content in $La_{1-x}Sr_xMn_{0.8}Cu_{0.2}O_3$ (LSMCu) were studied. $La_{0.8}Sr_{0.2}MnO_3$ (LSM) and $La_{1-x}Sr_xMn_{0.8}Cu_{0.2}O_3$ ($0.1{\leq}x{\leq}0.4$) were synthesized by EDTA citric complexing process (ECCP). A decrease in the lattice parameters and lattice volumes was observed with increase of Sr content, and these results were attributed to the increasing $Mn^{4+}$ ions and $Cu^{3+}$ ions in B-site. The electrical conductivity measured from $500^{\circ}C$ to $1000^{\circ}C$ was increased with increase of Sr content in the $0.1{\leq}x{\leq}0.3$ composition range, and it was 172.6 S/cm (at $750^{\circ}C$) and 177.7 S/cm (at $950^{\circ}C$, the maximum value) in x = 0.3. The electrical conductivity was decreased in x = 0.4 because of the presence of the second phase in the grain boundaries. The lattice volume was contracted by increase of $Mn^{4+}$ ions and $Cu^{3+}$ ions in B-site according to increase of Sr content and the electrical conductivity was increased with increase of charge carriers which were involved in the hopping mechanism.

Conceptual Design of the Three Unit Fixed Partial Denture with Glass Fiber Reinforced Hybrid Composites (Glass fiber 강화 복합레진을 사용한 3본 고정성 국소의치의 개념 설계 연구)

  • Na, Kyoung-Hee;Lee, Kyu-Bok;Jo, Kwang-Hun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.18 no.3
    • /
    • pp.145-155
    • /
    • 2002
  • The results of the present feasibility study are summarized as follows, 1. The three unit bridge of knitted material and UD fibre reinforcement has both the rigidity and the strength against a vertical occlusal load of 75N. 2. Stress concentration at the junctional area between the bridge and the abutments, i.e. between the pontic and the knitted caps was observed. In the case of the bridge with reinforcement straps, it was partly shown that the concentration problem could be improved by simply increasing the fillet size at the area. Further refining in the surface of the junctional area will be needed to ensure a further improvement in the stress distribution. This will require some trade off in the level of the stress and the available space. A parametric study will help to decide the appropriate size of the fillet. 3. Design refinement is a must to improve the stress distribution and realize the most favourable shape in terms of fabrication. The current straight bar with a constant cross section area can be redesigned to a tapered shape. The curve from the dental arch should also be placed on the pontic design. In accordance with design refinement, the resistance of the bridge frame to other load cases should be evaluated. 4. Although not included in the present feasibility study, it is estimated that bridges of the anterior teeth can be made strong enough with the knitted material without further reinforcement using unidirectional materials. In this regard, a feasibility study on design concepts and stress analysis for 3, 4, 5 unit bridge is suggested. 5. Two types of bridge were analysed in terms of fatigue. The safe life design concept, i.e. fatigue design concept, looks reasonable for the bridge where if cracks should form and propagate there is virtually nothing a dentist to do. The bridge must be designed so that no crack will be initiated during the life span. In the case of crowns, however, if constructed with composite resin with knitted materials, it might be possible to repair them, which in general is impossible for crowns of PFM or of metal. Therefore for composite resin crowns, a damage tolerance design concept can be applied and reasonably higher operational stresses can be allowed. In this case, of course, a periodic inspection program should be established in parallel. 6. Parts of future works in terms of structural viewpoint which need to be addressed are summarized as the following: 1) To develop processing technology to accommodate design concepts; 2) More realistic modelling of the bridge and analysis-geometry and loading condition. Thickness variation in the knitted material, taper in the pontic, design for anterior tooth bridge, the effect of combined loads, etc, will need to be included; 3) To develop appropriate design concepts and design goals for the fibre composite FPD aiming at taking the best advantage of knitted materials, including the damage tolerance design concept; 4) To develop testing method and perform test such as static ultimate load test, fatigue test, repair test, etc, as necessary.

Effects of Bisphenol A to interspecific hybrids between marine medaka Oryzias dancena and javanese medaka O. javanicus (바다송사리, Oryzias dancena와 자바송사리, O. javanicus 간 잡종에 대한 비스페놀 A의 효과)

  • Kim, Bong-Seok;Song, Ha-Yeun;Nam, Yoon-Kwon;Kim, Dong-Soo
    • Journal of fish pathology
    • /
    • v.24 no.2
    • /
    • pp.131-139
    • /
    • 2011
  • Bisphenol A (BPA) is mainly used in the production of epoxy resins and polycarbonate plastics, which is a known endocrine disruptor and acutely toxic to aquatic organisms. In this study, estrogenic effect of BPA was investigated on hybrid between Oryzias dancena and O. javanicus (ODJ). ODJ were exposed to BPA of various concentrations (eg. 2.5 mg/L, 5.0 mg/L and 10.0 mg/L) for 56 days. The growth rate, abnormality and the ratio of female and male were observed in test group and control group. As a result, the growth was $14.7{\pm}2.0$ mm in total length (TL) in 2.5 mg/L, $13.7{\pm}2.5$ mm in 5.0 mg/L, $12.8{\pm}2.5$ mm in 10.0 mg/L in test group while it was $18.0{\pm}1.2$ mm in TL in control group which was not treated with bisphenol A. The result showed that the growth decreased as the concentration of BPA increased. The abnormality rate was 13.6% in control group, 65.4% in 2.5 mg/L, 81.3% in 5.0 mg/L and 98.1 % in 10.0 mg/L which showed increase in abnormality as an increase of BPA concentration. As a result of analyzing ratio of sex in the test group and control group, 6.0% was examined to be interspecific in controls, 76.9% in 2.5 mg/L and 100.0% in 5.0 mg/L and 10.0 mg/L. In conclusion, these results suggest that BPA has estrogenic effect on ODJ.

Flowering Patterns of Miscanthus Germplasms in Korea (국내 수집 억새 유전자원의 출수 특성)

  • An, Gi-Hong;Um, Kyoung-Ran;Lee, Jun-Hee;Jang, Yun-Hui;Lee, Ji-Eun;Yu, Gyeong-Dan;Cha, Young-Lok;Moon, Yun-Ho;Ahn, Jong-Woong
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.60 no.4
    • /
    • pp.510-517
    • /
    • 2015
  • Miscanthus has been considered as the most promising bioenergy crop for lignocellulosic biomass production. In Korea, M. sacchariflorus and M. sinensis can be found easily in all regions. It is a great advantage to utilize as important species with respect to genetic and cross-breeding programs materials for creation of novel hybrids. For successful breeding programs, it is important to precisely understand the variability of flowering traits among Miscanthus species as breeding parents materials. In this study, flowering traits were observed daily in 960 germplasms of two Miscanthus species (M. sacchariflorus and M. sinensis) for growing seasons over 2 years. The flowering process was divided into three stages. ST (sprouting time) was recorded when first leaf of the plant emerged on soil. FS1 (flowering stage 1) and FS2 (flowering stage 2) were recorded when flag leaf was firstly observed, and 1 cm of panicle was showing on at least one stem, respectively. For 2013 and 2014, the latest germplasms exerted flag leaf, i.e. September 30 (DOY of FS1 164.1) and September 4 (DOY of FS1 141.0) occurred M. sacchariflorus cv. Geodae 1 and M. sacchariflorus cv. Uram collected from Southern Korea (Jeollanam-do), while Miscanthus germplasms collected from northern Korea (Gyeonggi-do) which emerged the earliest flag leaf in July and August, significantly decreased DOY. For DOY from ST to FS2, M. sacchriflorus germplasms ranged from 140 to 190 days, and 110 to 170 days for 2013 and 2014. The highest frequency showed to 160 days for 2013, and 150 days for 2014. In M. sinensis germplasms, the highest frequency showed to 180 days for 2013, and 170 days for 2014. In the results of correlation between the day of years from ST to FS2 for 2013 and 2014, M. sacchriflorus and M. sinensis showed high coefficient of correlation (0.70 and 0.89). It can be supposed that flowering characteristics of Miscanthus are largely affected by the unique phenotypic characteristic of native habitat than environmental factors of the current planted site. This study for flowering traits of Miscanthus may provides an important information in order to expedite the introduction as breeding materials for creation of new hybrid.

Feasibility of MatriXX for Intensity Modulated Radiation Therapy Quality Assurance (세기변조방사선치료의 품질관리를 위한 이온전리함 매트릭스의 유용성 고찰)

  • Kang, Min-Young;Kim, Yoen-Lae;Park, Byung-Moon;Bae, Yong-Ki;Bang, Dong-Wan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.2
    • /
    • pp.91-97
    • /
    • 2007
  • Purpose: To evaluate the feasibility of a commercial ion chamber array for intensity modulated radiation therapy (IMRT) quality assurance (QA) was performed IMRT patient-specific QA Materials and Methods: A use of IMRT patient-specific QA was examined for nasopharyngeal patient by using 6MV photon beams. The MatriXX (Wellhofer Dosimetrie, Germany) was used for IMRT QA. The case of nasopharyngeal cancer was performed inverse treatment planning. A hybrid dose distribution made on the CT data of MatriXX and solid phantom all of the same gantry angle (0$^\circ$). The measurement was acquired with geometrical condition that equal to hybrid treatment planning. The $\gamma$-index (dose difference 3%, DTA 3 mm) histogram was used for quantitative analysis of dose discrepancies. An absolute dose was compared at the high dose low gradient region. Results: The dose distribution was shown a good agreement by gamma evaluation. A proportion of acceptance criteria was 95.8%, 97.52%, 96.28%, 98.20%, 97.78%, 96.64% and 92.70% for gantry angles were 0$^\circ$, 55$^\circ$, 110$^\circ$, 140$^\circ$, 220$^\circ$, 250$^\circ$ and 305$^\circ$, respectively. The absolute dose in high dose low gradient region was shown reasonable agreement with the RTP calculation within $\pm$3%. Conclusion: The MatriXX offers the dosimetric characteristics required for performing both relative and absolute measurements. If MatriXX use in the clinic, it could be simplified and reduced the IMRT patient-specific QA workload. Therefore, the MatriXX is evaluated as a reliable and convenient dosimeter for IMRT patient-specific QA.

  • PDF

The Test of Combining Ability and Heterosis on the Silkworm(Bombyx mori) Breeding (누에 견.사질에 관한 잡종강세 및 조합능력검정)

  • 문병원;한경수
    • Journal of Sericultural and Entomological Science
    • /
    • v.36 no.1
    • /
    • pp.8-25
    • /
    • 1994
  • The study was conducted to obtain the genetic information on heterosis and combining ability of the quantitative characters for F1 hybrid breeding in silkworms. Six parental varieties and each set of 30 diallel crosses in F1's were used as materials, and bred on the randomized complete block design with three replications. Fourteen characters were observed with the twenty samples in each tray. The data were analyzed for (1) heterosis and combining ability in F1 hybrid. The heterosis in the weight and the length of cocoon showed positively high at 24.51%, and 23.4%, respectively and the weight of the whole cocoon as well as the weight of the whole cocoon layer showed a siginificant heterosis ranging from 15.56% to 15.71% and from 17.14% to 19.01%, but the fifth and the total instar period showed negative heterosis. It was found that the combination between, C70XRomogua and N9 X Romogua showed highly a negative heterosis on the fifth instar period and for the cocoon weight. The female of N9+Sansuian and the male of Romogua X Sansurian have a high heterosis effect, on the cocoon shell weight, and Sansurian X Romogua(reciprocal) on the length and the weight of cocoon filament with no regard to sexuality. The significant maternal and cytoplasmic effect on heterosis of the cocoon weight and the cocoon shell weight were observed with the combinations, N9 X C5, N63 X C70 and on the length of the cocoon filament with the combinations, Sansurian X N63, Sansurian X C5, Sansurian X C70 and N9 X C70, N63 X C70 on the weight of cocoon filament. As mean squared of GCA, SCA and RCA were significant with these combining ability for all characters resulted from additive and non-additive altogether and there is a significant difference between reciprocals. Sansurian showed a negative GCA effect on the fifth and total larval duration, but the higher positive GCA effects took places with varieties N9 and C5 on the length, width, weight of cocoon, cocoon shell weight, percentage of cocoon shell weight, length and weight of cocoon filament, percentage of raw-silk with no regard to both generations and silkworm sexuality. The values of SCA between the cross combinations varied generation-wise and sex-wise. It was shown that SCA value for the fifth instar period was highly negative for Sansurian X C70, Romogua X C70, Sansurian X C5, Romogua X C5, but it was positive effect on the cocoon weight, cocoon shell weight with N9 X C5, and C70 X Sansurian, on the length of cocoon filament with N9 X C5, Romogua X Sansurian on the weight of cocoon filament between Romogua and N63 and on the percentage of raw-silk between the combination of Sansurian X Romoga.

  • PDF

Study on Waxy Corn X. Analysis on Botanical Characteristics, Physicochemical Properties Related to Table Qualities of the Developed Waxy Corn Hybrids (찰옥수수 연구 X. 육성된 찰옥수수 교잡종의 식물학적 특성 및 식미관련 이화학적 형질)

  • Lee, Moon-Sub;Bok, Tae-Gyu;Choi, Yun-Pyo;Hong, Bom-Young;Jo, Yang-Hee;Lee, Hee-Bong
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.56 no.1
    • /
    • pp.8-13
    • /
    • 2011
  • This study was carried out to compare botanical characteristics, physicochemical properties related to table quality and feed values and develop a new variety among 12 developed waxy com hybrids. These materials were produced in 2008 and cultivated in 2009 at Com Breeding and Genetics Farm of Coll. of Agri. & Life Sci., Chungnam Nat'l Univ. Botanical characteristics of used waxy com hybrids showed large difference among hybrids; stem height, ear height and ear length. In physical properties, range of kernel sugar content among used hybrids appeared 16.1 to 13.0brix(%). CNU08H-15, CNU08H-35 and CNU08H-h39 among these were highly appeared as 15 above and pericarp thickness of Yeonongchal was very thick as $46.0{\mu}m$, while CNU08H-39 among hybrids showed the thinnest as $23.0{\mu}m$ compared to other hybrids. Protein content as a indicator of table quality was the highest in Ilmichal among hybrids, while that of CNU08H-39 was the lowest, while amylopectin content was the highest as 94.5%, From experimental results, Daehakchal Gold 1, CNU08H-h121 and CNU08H-39 including check Yeonyoungchal were highly evaluated as new hybrid in thinner pericarp, high amylopectin and chewiness.

Reverse engineering technique on the evaluation of impression accuracy in angulated implants (경사진 임플란트에서 임플란트 인상의 정확도 평가를 위한 역공학 기법)

  • Jung, Hong-Taek;Lee, Ki-Sun;Song, So-Yeon;Park, Jin-Hong;Lee, Jeong-Yol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.3
    • /
    • pp.261-270
    • /
    • 2021
  • Purpose. The aim of this study was (1) to compare the reverse engineering technique with other existing measurement methods and (2) to analyze the effect of implant angulations and impression coping types on implant impression accuracy with reverse engineering technique. Materials and methods. Three different master models were fabricated and the distance between the two implant center points in parallel master model was measured with different three methods; digital caliper measurement (Group DC), optical measuring (Group OM), and reverse engineering technique (Group RE). The 90 experimental models were fabricated with three types of impression copings for the three different implant angulation and the angular and distance error rate were calculated. One-way ANOVA was used for comparison among the evaluation methods (P < .05). The error rates of experimental groups were analyzed by two-way ANOVA (P < .05). Results. While there was significant difference between Group DC and RE (P < .05), Group OM had no significant difference compared with other groups (P > .05). The standard deviations in reverse engineering were much lower than those of digital caliper and optical measurement. Hybrid groups had no significant difference from the pick-up groups in distance error rates (P > .05). Conclusion. The reverse engineering technique demonstrated its potential as an evaluation technique of 3D accuracy of impression techniques.

COMPARISON OF POLYMERIZATION SHRINKAGE AND STRAIN STRESS OF SEVERAL COMPOSITE RESINS USING STRAIN GUAGE (스트레인 게이지를 이용한 수종의 복합레진의 중합수축 및 수축응력의 비교)

  • Kim, Young-Kwang;Yoo, Seung-Hoon;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.3
    • /
    • pp.516-526
    • /
    • 2004
  • Polymerization shrinkage of photoinitiation type composite resin cause several clinical problems. The purpose of this study was to evaluate the shrinkage strain stress, linear polymerization shrinkage, compressive strength and microhardness of recently developed composite resins. The composite resins were divided into four groups according to the contents of matrix and filler type. Group I : $Denfil^{TM}$(Vericom, Korea) with conventional matrix, Group II : $Charmfil^{(R)}$(Dentkist, Korea) with microfiller and nanofller mixture, Group III : $Filtek^{TM}$ Z250(3M-ESPE, USA) TEGDMA replaced by UDMA and Bis-EMA(6) in the matrix, and Group IV : $Filtek^{TM}$ Supreme(3M-ESPE, USA) using pure nanofiller. Preparation of acrylic molds were followed by filling and curing with light gun. Strain gauges were attached to each sample and the leads were connected to a strainmeter. With strainmeter shrinkage strain stress and linear polymerization shrinkage was measured for 10 minutes. The data detected at 1 minute and 10 minutes were analysed statistically with ONE-way ANOVA test. To evaluate the mechanical properties of tested materials, compressive hardness test and microhardness test were also rendered. The results can be summarized as follows : 1. Filling materials in acrylic molds showed initial temporary expansion in the early phase of polymerization. This was followed by contraction with the rapid increase in strain stress during the first 1 minute and gradually decreased during post-gel shrinkage phase. After 1 minute, there's no statistical differences of strain stress between groups. The highest strain stress was found in group IV and followed by group III, I, II at 10 minutes-measurement(p>.05). In regression analysis of strain stress, group III showed minimal inclination and followed by group II, I, IV during 1 minute. 2. In linear polymerization shrinkage test, the composite resins in every group showed initial increase of shrinkage velocity during the first 1 minute, followed by gradually decrease of shrinkage velocity. After 1 minute, group IV and group III showed statistical difference(p<.05). After 10 minutes, there were statistical differences between group IV and group I, III(p<.05) and between group II and group III(p<.05). In regression analysis of linear polymerization shrinkage, group II showed minimal inclination and followed by group IV, III, I during 1 minute. 3. In compressive strength test, group III showed the highest strength and followed by group II, IV, I. There were statistical differences between group III and group IV, I(p<.05). 4. In microhardness test, upper surfaces showed higher value than lower surfaces in every group(p<.05).

  • PDF