• 제목/요약/키워드: Hybrid desiccant dehumidification

검색결과 12건 처리시간 0.026초

Energy Saving Components Analysis in Hybrid Desiccant Dehumidification System (하이브리드 데시칸트 제습방식 에너지 절감 요소분석)

  • Park, Jongil;Park, Seungtae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제27권11호
    • /
    • pp.603-608
    • /
    • 2015
  • The hybrid desiccant dehumidifier is an energy-effective system in comparison with the existing desiccant dehumidifier. Its main feature is to use the heat given off by the condenser as the react heat source. Through analysis of the elements for a more efficient design of the hybrid desiccant dehumidifier, it is evident that those energy-saving components do not work individually, but organically influence the efficiency of the equipment. Therefore, the hybrid desiccant dehumidifier may be an important product in the dehumidification industry.

A Fundamental Study on the Composition for the Hybrid Dehumidification System Using Thermoelectric Device (열전소자를 활용한 하이브리드 제습시스템의 구성에 관한 기초적 연구)

  • Ryu, Seong-Ryong;Yeom, Ho-Jin;Lee, Hyun-Jae;Cho, Hyun
    • Journal of Korean Institute of Architectural Sustainable Environment and Building Systems
    • /
    • 제12권6호
    • /
    • pp.618-626
    • /
    • 2018
  • In this paper, the hybrid dehumidification system using thermoelectric device is based on the idea of utilizing waste heat from the heat dissipation side of thermoelectric device as a heat source to regenerate chemical desiccant. We would like to apply this system to spaces required dehumidification due to continuous moisture generation or local high humidity in the houses. And, we want to confirm the possibility of developing the hybrid dehumidification system that combines passive dehumidification using chemical desiccant with active dehumidification using thermoelectric device.

Study on the Energy Efficiency Improvement of Hybrid Dehumidification Air Conditioning System Compared with Refrigeration System (냉각식 시스템과 비교한 복합식 제습냉방시스템의 냉각 열량증가에 관한 실험적 연구)

  • Lee Su-Dong;Park Moon-Soo;Chung Jin-Eun;Choi Young-Seok
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제16권10호
    • /
    • pp.952-959
    • /
    • 2004
  • The hybrid liquid desiccant air conditioning system has been in use for many years, primarily in industrial process applications requiring dehumidification and humidity control. In this study, the hybrid dehumidifier has been designed to study the dehumidification characteristic of the aqueous triethylene glycol (TEG) solution. The experimental results show energy efficient characteristics of hybrid liquid desiccant air conditioning system compared with the refrigeration system in terms of energy use, the difference of pressure loss between hybrid liquid desiccant air conditioning system and refrigeration system. Data obtained are useful for design guidance and performance analysis of the hybrid air conditioning system.

An Experimental Study on the Optimization of Performance Parameter for Membrane Based Dehumidification and Air Conditioning System (분리막 제습공조 시스템의 성능변수 최적화를 위한 실험적 연구)

  • Jang, Jeachul;Kang, Eun-Chul;Jeong, Siyoung;Park, Seong-Ryong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제28권2호
    • /
    • pp.75-80
    • /
    • 2016
  • There are three types of dehumidification systems : refrigeration dehumidification method, desiccant dehumidification method and hybrid dehumidification method. The first method involves removing moisture by condensation below the dew point, the second method involves absorption by a desiccant material and the last is an integration method. However, the refrigeration dehumidification system consumes too much power and controlling the humidity ratio is difficult. The desiccant dehumidification system uses less power but it has problems of environmental pollution. The hybrid dehumidification system has the disadvantage of a high initial cost. On the other hand, the energy consumption of the membrane based dehumidification system is lower than for the refrigeration dehumidification system. Also, it is an environmentally friendly technology. In this study, the performance parameters are evaluated for the dehumidification system using a hollow fiber membrane. Available area, duct side dry-bulb temperature, sweep gas flux (flow rate) and LMPD (Log Mean Pressure Difference) were used as the performance parameters.

An Experimental Study on the Performance Characteristics with Height of a Fin-Tube Liquid Desiccant Dehumidifier (휜-튜브형 액체건조제 제습기의 높이에 따른 성능특성에 관한 실험적 연구)

  • Lee, Su-Dong;Park, Moon-Soo;Chung, Jin-Eun;Choi, Young-Seok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • 제28권5호
    • /
    • pp.594-603
    • /
    • 2004
  • Several desiccant cooling systems have been developed in terms of cost and performance. In this study a fin-tube exchanger has been used for liquid desiccant dehumidification system. This dehumidifier has been designed to study the absorption characteristic of the aqueous triethylene glycol(TEG) solution which has the flow range from 20 to 50 LPM. The dehumidifier performance characteristics of working factor variables such as inlet solution flow rate, air flow rate, solution concentration and brine temperature have been analyzed. This dehumidifier has the ability to provide running while saving the latent heat load of total energy. The result of this experiment can provide useful data for hybrid air conditioning system.

An Experimental Study on the Performance Characteristic with Height of a Fin-Tube Liquid Desiccant Dehumidifier (핀-튜브형 액체건조제 제습기의 높이에 따른 성능특성에 관한 실험적 연구)

  • Lee, Su-Dong;Park, Moon-Soo;Chung, Jin-Eun;Lee, Jin-Soo
    • Proceedings of the KSME Conference
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.25-30
    • /
    • 2003
  • Several desiccant cooling systems have been developed in terms of cost and performance. In this study a fin-tube exchanger has been used for liquid desiccant dehumidification system. This dehumidifier has been designed to study the absorption characteristic of the aqueous triethylene glycol(TEG) solution which has the flow range from 20 to 50 LPM. The dehumidifier performance characteristic of working factor variables such as inlet solution flow rate, air flow rate, solution concentration, solution temperature, brine temperature, air temperature and inlet air relative humidity has been analyzed. The result of this experiment can provide useful data for hybrid air conditioning system.

  • PDF

Study on the Effect of Performance Factors on the Evaporator Using Liquid Desiccant Falling Flim for Dehumidification (습식건조제 이용 제습에서의 증발기 성능인자 영향 연구)

  • Park, M.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제7권3호
    • /
    • pp.512-520
    • /
    • 1995
  • This study investigates the simultanceous heat and mass transfer between a falling desiccant film and air in cross flow at the interface. The application of this work is the optimization of falling film evaporators for use in potential hybrid air conditioning systems. The specific geometry considered is liquid TEG films falling along the vertical cooled surfaces of a channel with air in cross flow. The equations to describe the coupled heat and mass transfer between a falling desiccant film and air in cross flow for a falling film evaporator have been presented and solved numerically. The effects of important design and operating variables on the evaporator performance predicted by the parametric numerical analysis and suggestions for performance improvements of the evaporator are presented.

  • PDF

Study on the Performance Characteristics with the Height of a Regenerator and Dehumidifier for Liquid Desiccant Dehumidification System (액체식 제습시스템을 위한 재생기와 제습기의 높이에 따른 성능특성에 관한 연구)

  • 이수동;박문수;정진은;최영석
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제16권7호
    • /
    • pp.630-638
    • /
    • 2004
  • Liquid desiccant dehumidification systems have the ability to provide efficient humidity and temperature control while saving the electrical energy requirement for air conditioning as compared to a conventional system. The dehumidifier and the regenerator form the heart of this system. The latent part of the cooling load is overcome using liquid desiccant. The model regenerator has been designed to study the absorption characteristic of the aqueous triethylene glycol (TEG) solution which is in the flow range from 20 to 50 LPM. Also, this system designed that was able to change the height of the regenerator and dehumidifier. Because the effect of performance have different result according the height. The effect of performance factors of the regenerator with inlet solution flow rate, air flow rate, solution concentration, solution temperature, brine temperature, air temperature and inlet air relative humidity have been analyzed. Data obtained are useful for design guidance and performance analysis of the hybrid air conditioning system.

Hybrid Desiccant Dehumidifier for Shipbuilding Painting (하이브리드 데시칸트 선박도장용 제습기)

  • Park, Seung-Tae;Kum, Jong-Soo;Kim, Hue-Jae;Kim, Dong-Hyuk
    • Proceedings of the SAREK Conference
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.248-253
    • /
    • 2009
  • For the energy's effective utilization, the mixed humidifier has been developed and popularized by combining the cooling dehumidifier with the desiccant humidifier properly. This has contributed in many ways to the industry. Hybrid Desiccant Dehumidifier that would be shown in this study could be indispensible in site due to the reduced equipment, with more than 50% reduction in energy.

  • PDF

R&D Trend in desiccant based dehumidification and hybrid cooling system (건조제(desiccant)를 이용한 제습 및 복합냉방 시스템의 기술개발동향)

  • 박문수
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • 제27권6호
    • /
    • pp.533-540
    • /
    • 1998
  • 최근에 국내외 에너지 이용 효율성 증대 문제, CFCs등으로 인한 오존층 파괴문제, $CO_2$ 등으로 인한 지구온난화 문제, 실내공기질(IAQ)과 관련된 건물 환기량 증대요구로 인한 건물용 공조시스템(HVAC)의 설계변경 문제 등으로 인해 다양한 종류의 대체 냉방기기가 연구되어 오고 있다. 현재 미국에서는 ASHRAE Standard 62-1989에 의해 실내거주자의 필요한 IAQ와 쾌적함을 유지하기 위해 환기량을 기존의 경우보다 약 3배 이상이 되도록 권장하고 있고 또한 대다수의 미국 주 정부에서 건물설계에 관련된 조례로 ASHRAE Standard 62-1989를 적용하고 있다. 따라서 빌딩공조 설비관계자들은 늘어난 환기 요구량에 따라 잠열냉방용량이 크게 증대되므로 이를 처리하기 위한 새로운 냉방공조기기 시스템기술에 대해 관심이 증대하고 있다. 이에 따라 건조제를 x이용한 냉방 및 제습 시스템이 대체 냉방시스템 또는 기존의 냉방 시스템과 더불어 잠열부하를 처리하는 복합 시스템으로 최근에 다시 상당한 주목을 받고 있다.

  • PDF