• 제목/요약/키워드: Hybrid composite beams

검색결과 79건 처리시간 0.029초

알루미늄-복합재료 혼성 사각관 보의 굽힘 성능평가 (Bending Performance Evaluation of Aluminum-Composite Hybrid Square Tube Beams)

  • 이성혁;최낙삼
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2005년도 춘계학술발표대회 논문집
    • /
    • pp.76-79
    • /
    • 2005
  • Bending deformation and energy absorption characteristics of aluminum-composite hybrid tube beams have been analyzed for improvement in the bending performance of aluminum space frame by using experimental tests combined with theoretical and finite element analyses. Hybrid tube beams composed of glass fabric/epoxy layer wrapped around on aluminum tube were made in autoclave with the recommended curing cycle. Basic properties of aluminum material used for initial input data of the finite element simulation and theoretical analysis were obtained from the true stress-true strain curve of specimen which had bean extracted from the Al tube beam. A modified theoretical model was developed to predict the resistance to the collapse of hybrid tube beams subjected to a bending load. Theoretical moment-rotation angle curves of hybrid tube beams were in good agreement with experimental ones, which was comparable to the results obtained from finite element simulation. Hybrid tube beams strengthened by composite layer on the whole web and flange showed an excellent bending strength and energy absorption capability.

  • PDF

Free vibration and buckling analysis of the impacted hybrid composite beams

  • Ergun, Emin;Yilmaz, Yasin;Callioglu, Hasan
    • Structural Engineering and Mechanics
    • /
    • 제59권6호
    • /
    • pp.1055-1070
    • /
    • 2016
  • The aim of this experimental study is to investigate the free vibration and buckling behaviors of hybrid composite beams having different span lengths and orientation angles subjected to different impact energy levels. The impact energies are applied in range from 10 J to 30 J. Free vibration and buckling behaviors of intact and impacted hybrid composite beams are compared with each other for different span lengths, orientation angles and impact levels. In free vibration analysis, the first three modes of hybrid beams are considered and natural frequencies are normalized. It is seen that first and second modes are mostly affected with increasing impact energy level. Also, the fundamental natural frequency is mostly affected with the usage of mold that have 40 mm span length (SP40). Moreover, as the impact energy increases, the normalized critical buckling loads decrease gradually for $0^{\circ}$ and $30^{\circ}$ oriented hybrid beams but they fluctuate for the other beams.

Effect of the GFRP wrapping on the shear and bending Behavior of RC beams with GFRP encasement

  • Ozkilic, Yasin Onuralp;Gemi, Lokman;Madenci, Emrah;Aksoylu, Ceyhun;Kalkan, İlker
    • Steel and Composite Structures
    • /
    • 제45권2호
    • /
    • pp.193-204
    • /
    • 2022
  • The need for establishing the contribution of pultruded FRP encasements and additional FRP wraps around these encasements to the shear strength and load-deflection behavior of reinforced concrete beams is the main motivation of the present study. This paper primarily focuses on the effect of additional wrapping around the composite beam on the flexural and shear behavior of the pultruded GFRP (Glass Fiber Reinforced Polymer) beams infilled with reinforced concrete, taking into account different types of failure according to av/H ratio (arch action, shear-tension, shear-compression and pure bending). For this purpose, nine hybrid beams with variable shear span-to-depth ratio (av/H) were tested. Hybrid beams with 500 mm, 1000 mm, and 1500 mm lengths and cross-sections of 150x100 mm and 100x100 mm were tested under three-point and four-point loading. Based on the testing load-displacement relationship, ductility ratio, energy dissipation capacity of the beams were evaluated with comprehensive macro damage analysis on pultruded GFRP profile and GFRP wrapping. The GFRP wraps were established to have a major contribution to the composite beam ductility (90-125%) and strength (40-75%) in all ranges of beam behavior (shear-dominated or dominated by the coupling of shear and flexure). The composite beams with wraps were showns to reach ductilities and strength values of their counterparts with much greater beam depth.

Hybrid Vibration Control of Smart Laminated Composite Beams using Piezoelectric and Viscoelastic Material

  • Kang, Young-Kyu
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제4권1호
    • /
    • pp.37-42
    • /
    • 2003
  • Active control of flexural vibrations of smart laminated composite beams has been carried out using piezoceramic sensor/actuator and viscoelastic material. The beams with passive constrained layer damping have been analyzed by formulating the equations of motion through the use of extended Hamilton's principle. The dynamic characteristics such as damping ratio and modal damping of the beam are calculated for various fiber orientations by means of iterative complex eigensolution method. This paper addresses a design strategy of laminated composite under flexural vibrations to design structure with maximum possible damping capacity.

철골 프리캐스트 콘크리트 합성보 성능 분석 연구 (Load carrying capacity of Structural Composite Hybrid System (Green Frame))

  • 홍원기;김선국;김승일
    • KIEAE Journal
    • /
    • 제10권1호
    • /
    • pp.25-31
    • /
    • 2010
  • An experimental investigation of composite beams composed of wide flange steel and precast concrete is presented. The bottom flange of the steel section is encased in precast concrete. The composite beams tested in this study were designed to reduce the depth of the slab and beam. The slabs are constructed on top of the edges of the Structural Composite Hybrid System, instead of on top of the steel flange, decreasing the depth of the beams. When concrete is cast on the metal deck plate located on the edges of the precast concrete, the weight of the concrete slabs and other construction loads must be supported by the contacts between the steel and the precast concrete. This interface must not exhibit bearing failures, shear failures, and failures caused by torque due to the loading of the precast concrete. When the contact area between the concrete and the bottom flange of the steel beam is small, these failures of the concrete are likely and must be prevented. The premature failure of precast concrete must not also be present when the weight of the concrete slabs and other construction loads is loaded. This paper presents a load carrying capacity of Structural Composite Hybrid System in order to observe the failure mode. The symmetrically distributed loading that caused the failure of the composite beam was found. The paper also provides design recommendations of such type of composite structure.

하이브리드 FRP로 보강된 콘크리트 보의 거동 예측을 위한 해석연구 (Analytical Studies for Predicting Behaviors of RC Beams Retrofitted with Hybrid FRPs)

  • 우투이 나디아;김희선
    • 복합신소재구조학회 논문집
    • /
    • 제2권2호
    • /
    • pp.1-6
    • /
    • 2011
  • 본 연구는 하이브리드 FRP로 보강된 철근 콘크리트 보의 구조거동 예측을 목표로 구조해석을 수행하여 기존에 발표된 실험 연구 데이터와 비교하였다. 보다 정확한 구조해석을 위하여 현존하는 다양한 부착강도 모델을 검토한 후, 이 중 콘크리트 피복분리를 예측하는 Teng and Yao model과 FRP 탈락 현상을 예측할 수 있는 Smith and Teng model을 유한요소 해석 모델에 포함시켰다. 비선형 재료 및 형상 역시 구조해석 모델에 포함되었으며 이렇게 해석된 결과는 실험결과와 비교하여 유사한 경향을 나타냈다. 그러나 다양한 하이브리드 FRP로 보강한 철근 콘크리트 보의 파괴모드를 보다 정확하게 예측하기 위하여 현존하는 수치식의 수정 및 도입이 필요하다.

고강도강재를 적용한 비대칭 하이브리드 합성보의 휨거동 실험 (Flexural Testing of Asymmetric Hybrid Composite Beams Fabricated from High-strength Steels)

  • 전수찬;한규홍;이철호;김진원
    • 한국강구조학회 논문집
    • /
    • 제29권3호
    • /
    • pp.217-228
    • /
    • 2017
  • 본 연구에서는 고강도강재를 적용한 비대칭 하이브리드 합성보의 휨성능을 실물대 실험을 통하여 평가하였다. 합성보의 웨브와 상부플랜지에는 일반강재(SM400, SM490)를 적용하고 하부플랜지는 상부플랜지에 비해 상대적으로 크게 제작하여 비대칭 단면으로 적용한 후 일반강재(SM520) 및 고강도강재(SM570, HSA800)를 각각 적용하였다. 본 연구의 주요 목적은 비대칭 하이브리드 합성보의 휨성능 평가 및 설계지침의 개발이다. 실험결과 하부플랜지에 일반강재를 적용한 실험체의 경우 $Dp/Dt{\leq}0.15$를 만족시킬 시 우수한 휨강도와 연성능력을 발현하는 것을 확인하였다. 반면 하부플랜지에 고강도강재가 적용된 실험체의 경우 휨내력의 증가로 인한 슬래브의 수평전단력 증가가 예상치 못한 슬래브 종방향 전단파괴를 발생시켜 소성강도에 도달하지 못하였다. 따라서 고강도강재를 적용한 비대칭 하이브리드 합성보의 경우 설계단계에서 슬래브 수평전단강도 확보가 필수적이다.

Flexural behavior of prestressed hybrid wide flange beams with hollowed steel webs

  • Han, Sun-Jin;Joo, Hyo-Eun;Choi, Seung-Ho;Heo, Inwook;Kim, Kang Su
    • Steel and Composite Structures
    • /
    • 제38권6호
    • /
    • pp.691-703
    • /
    • 2021
  • In this study, experiments were conducted to evaluate the flexural performance of prestressed hybrid wide flange (PHWF) beams with hollowed steel webs. A total of four PHWF beams were fabricated, where the width and spacing of the steel webs and the presence of cast-in-place (CIP) concrete were set as the main test parameters, and their flexural behavior and crack patterns, and the longitudinal strain distribution in a section with respect to the width and spacing of the steel webs were analyzed in detail. The experiment results showed that, as the ratio of the width to the spacing of the steel webs decreased, the flexural stiffness and strength of the PHWF beams without CIP concrete decreased. In addition, in the case of composite PHWF beam with CIP concrete, fully composite behavior between the precast concrete and the CIP concrete was achieved through the embedded steel member. Finite element analyses were performed for the PHWF beams considering the bond properties between the hollowed steel webs and concrete, and nonlinear flexural analyses were also conducted reflecting the pre-compressive strains introduced only into the bottom flange. From the comparison of the test and analysis results, it was confirmed that the analysis models proposed in this study well evaluated the flexural behavior of PHWF beams with and without CIP concrete.

Multiscale bending and free vibration analyses of functionally graded graphene platelet/ fiber composite beams

  • Garg, A.;Mukhopadhyay, T.;Chalak, H.D.;Belarbi, M.O.;Li, L.;Sahoo, R.
    • Steel and Composite Structures
    • /
    • 제44권5호
    • /
    • pp.707-720
    • /
    • 2022
  • In the present work, bending and free vibration analyses of multilayered functionally graded (FG) graphene platelet (GPL) and fiber-reinforced hybrid composite beams are carried out using the parabolic function based shear deformation theory. Parabolic variation of transverse shear stress across the thickness of beam and transverse shear stress-free conditions at top and bottom surfaces of the beam are considered, and the proposed formulation incorporates a transverse displacement field. The present theory works only with four unknowns and is computationally efficient. Hamilton's principle has been employed for deriving the governing equations. Analytical solutions are obtained for both the bending and free vibration problems in the present work considering different variations of GPLs and fibers distribution, namely, FG-X, FG-U, FG-Λ, and FG-O for beams having simply-supported boundary condition. First, the matrix is assumed to be strengthened using GPLs, and then the fibers are embedded. Multiscale modeling for material properties of functionally graded graphene platelet/fiber hybrid composites (FG-GPL/FHRC) is performed using Halpin-Tsai micromechanical model. The study reveals that the distributions of GPLs and fibers have significant impacts on the stresses, deflections, and natural frequencies of the beam. The number of layers and shape factors widely affect the behavior of FG-GPL-FHRC beams. The multilayered FG-GPL-FHRC beams turn out to be a good approximation to the FG beams without exhibiting the stress-channeling effects.

부분 비부착 NSM Hybrid FRP 보강근에 의한 철근콘크리트보의 연성보강 (Ductile Strengthening of Reinforced Concrete Beams by Partially Unbonded NSM Hybrid FRP Rebars)

  • 이차돈;정상모;원종필;이승환
    • 콘크리트학회논문집
    • /
    • 제15권1호
    • /
    • pp.143-153
    • /
    • 2003
  • 철근콘크리트를 FRP 복합재로 보강할 경우, 취성파괴를 방지하고 연성파괴를 확보할 수 있는 새로운 기법을 표면매립공법(Near Surface Mounted technique: 이하 NSM 공법)에 근거하여 제시하였다. 제안된 기법은 Hybrid FRP rebar를 부분적으로 비부착 시킴으로서 보강된 보의 연성을 확보한다. Hybrid FRP rebar의 일부를 비부착으로 한 경우와 전부를 부착으로 한 경우의 NSM 공법에 의한 FRP 보강된 철근 콘크리트보의 거동을 비교하기 위한 실험을 실시하였다. 실험 결과, 부분 비부착 NSM 공법으로 보강된 철근 콘크리트보만이 연성거동을 함이 관찰되었다. 부분 비부착 보강된 보의 극한 시 내력을 확보하기 위한 최소한의 FRP의 부분 비부착길이를 이론적으로 산정하여 제시하였다. 제시된 부분 비부착 NSM 공법은 FRP 복합재로 보강된 철근 콘크리트 부재의 구조적 거동을 크게 향상시킬 수 있으리라 기대된다.