• 제목/요약/키워드: Hybrid System Simulation

검색결과 922건 처리시간 0.023초

운전비용 절감을 위한 가정용 연료전지 시스템의 운전전략 수립 (A simulation study on operation strategy of residential fuel cell system for cost curtailment)

  • 황수영;김민진;이진호;이원용
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 추계학술대회 논문집
    • /
    • pp.55-58
    • /
    • 2008
  • Residential fuel cell cogeneration systems have gained much interest due to its high efficiency. In this study, we have performed numerical simulation of residential fuel cell cogeneration system which includes a fuel cell/grid hybrid system. The cogeneration system consists of 1kW PEFC, cooling system, inverter/converter and reformer. Several empirical models have been employed for respective components to improve the accuracy of the simulations. The load varies seasonally. The present simulations can successfully predict the characteristics of the hybrid cogeneration system and thus it can be utilized for establishing an optimal operating strategy of the system.

  • PDF

가정용 연료전지 시스템 대상 시뮬레이션 기반 비용절감 기법 연구 (A simulation study on residential fuel cell system for cost curtailment)

  • 황수영;김민진;이진호;이원용
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.3148-3153
    • /
    • 2008
  • Residential fuel cell cogeneration systems have gained much interest due to its high efficiency. In this study, we have performed numerical simulation of residential fuel cell cogeneration system which includes a fuel cell/grid hybrid system. The cogeneration system consists of 1kW PEFC, cooling system, inverter/converter and reformer. Several empirical models have been employed for respective components to improve the accuracy of the simulations. The load varies seasonally. The present simulations can successfully predict the characteristics of the hybrid cogeneration system and thus it can be utilized for establishing an optimal operating strategy of the system.

  • PDF

Bang-Bang 형태의 제어기를 갖는 복합제어 (Hybrid Control with a Bang-Bang Type Controller)

  • 박규식;정형조;조상원;이인원
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.193-200
    • /
    • 2003
  • This paper presents a hybrid (i.e., integrated passive-active) system for seismic response control of a cable-stayed bridge. Because multiple control devices are operating, a hybrid control system could alleviate some of the restrictions and limitations that exist when each system is acting alone. Lead rubber bearings are used as passive control devices to reduce the earthquake-induced forces in the bridge and hydraulic actuators are used as active control devices to further reduce the bridge responses, especially deck displacements. In the proposed hybrid control system, a linear quadratic Gaussian control algorithm is adopted as a primary controller. In addition, a secondary bang-bang type (i.e., on-off type) controller according to the responses of lead rubber bearings is considered to increase the controller robustness. Numerical simulation results show that control performances of the hybrid control system are superior to those of the passive control system and slightly better than those of the fully active control system. Furthermore, it is verified that the hybrid control system with a bang-bang type controller is more robust for stiffness perturbation than the active controller with μ-synthesis method and there are no signs of instability in the overall system whereas the active control system with linear quadratic Gaussian algorithm shows instabilities in the perturbed system. Therefore, the proposed hybrid protective system could effectively be used to seismically excited cable-stayed bridges.

  • PDF

Development of hybrid shielding system for large-area Compton camera: A Monte Carlo study

  • Kim, Jae Hyeon;Lee, Junyoung;Kim, Young-su;Lee, Hyun Su;Kim, Chan Hyeong
    • Nuclear Engineering and Technology
    • /
    • 제52권10호
    • /
    • pp.2361-2369
    • /
    • 2020
  • Compton cameras using large scintillators have been developed for high imaging sensitivity. These scintillator-based Compton cameras, however, mainly due to relatively low energy resolution, suffer from undesired background-radiation signals, especially when radioactive materials' activity is very low or their location is far from the Compton camera. To alleviate this problem for a large-size Compton camera, in the present study, a hybrid-type shielding system was designed that combines an active shield with a veto detector and a passive shield that surrounds the active shield. Then, the performance of the hybrid shielding system was predicted, by Monte Carlo radiation transport simulation using Geant4, in terms of minimum detectable activity (MDA), signal-to-noise ratio (SNR), and image resolution. Our simulation results show that, for the most cases, the hybrid shielding system significantly improves the performance of the large-size Compton camera. For the cases investigated in the present study, the use of the shielding system decreased the MDA by about 1.4, 1.6, and 1.3 times, increased the SNR by 1.2-1.9, 1.1-1.7, and 1.3-2.1 times, and improved the image resolution (i.e., reduced the FWHM) by 7-8, 1-6, and 3-5% for 137Cs, 60Co, and 131I point source located at 1-5 m from the imaging system, respectively.

실내공기질을 고려한 공동주택의 하이브리드 환기 시스템의 운영에 관한 연구 (A Study on the Operational Strategy for Hybrid Ventilation System in Apartment unit focused on Indoor Air Quality)

  • 이용준;이승복;이경회
    • KIEAE Journal
    • /
    • 제4권3호
    • /
    • pp.203-210
    • /
    • 2004
  • This dissertation identifies and investigates the possible control modes of hybrid ventilation system in applying to general apartments. It evaluates range of hybrid ventilation control modes in terms of indoor air quality, thermal comfort, and energy consumption in a living room and a kitchen of the $1000m^2$ apartment. The TRNSYS simulation program was used for evaluating the following four ventilation types : A ventilation mode relying on only infiltration for supplying air, A natural ventilation mode considering with weather condition, A hybrid ventilation (natural + mechanical ventilation) mode allowing minimum ventilation with no heat exchange, and a hybrid ventilation mode with heat exchange. This study shows the following results. As temperature being controlled by heating cooling equipments, there is without significant difference in thermal performance among ventilation types. Regarding Indoor Air quality, Indoor air contamination level of the hybrid ventilation case consistently keep the lower levels. The hybrid ventilation modes consume more energy by a 49% as compared to the A ventilation mode relying on only infiltration for supplying air. It is caused by the continuous ventilation for keeping good indoor air quality; the increase of energy consumption can be attributable to the increase of the heating energy. Therefore, the heat exchange between indoor and outdoor air is required during heating season in severe weather conditions. During the cooling seasons, Introducing natural ventilation can achieve energy saving by 40 ~ 45%. Thus, it can be an effective strategies for energy saving. Based on these results, a hybrid ventilation system can be suggested as an effective ventilation strategy for archiving high level of indoor air quality, thermal comfort, and energy consumption.

대체장비를 고려한 항공기 부품 생산라인의 ARENATM 시뮬레이션 모델링 방법론 (Simulation Modeling Method Using ARENATM Considering Alternative Machines in the Manufacturing System for Aircraft Parts)

  • 나상현;문덕희
    • 한국시뮬레이션학회논문지
    • /
    • 제25권4호
    • /
    • pp.1-12
    • /
    • 2016
  • 항공기 엔진부품을 생산하는 제조산업은 전통적인 주문형 제조방식을 따르며, 다품종 소량생산시스템이다. 또한 생산공장의 배치는 유사한 기능을 가지는 병렬 기계들이 공정별 배치 형태로 구성되어 있고 조립공정이 포함되는 Hybrid Job Shop이다. 더 나아가 다양한 대체장비를 가지고 있으며, 공정 경로도 다양하고, 조립공정도 포함되어 있다. 이와 같은 복잡한 시스템의 생산능력을 검증하기 위해서는 시뮬레이션이 가장 우수한 방법이며, 정확한 모델의 개발을 위해 고도의 시뮬레이션 모델링기술이 필요하다. 이 논문에서는 위에서 언급한 복잡한 특성을 가진 생산시스템을 효과적으로 모델링하기 위한 방법론을 소개하고, 실제 항공기부품 생산업체를 대상으로 시뮬레이션 연구를 수행한 사례에 대해 소개한다.

복합동반쓰기를 사용하는 디스크 시스템의 성능 평가 (Performance Evaluations of Hybrid Write-Piggybacking Technique for Disk System)

  • 장윤석;김홍일;김국보
    • 한국정보처리학회논문지
    • /
    • 제3권4호
    • /
    • pp.983-991
    • /
    • 1996
  • 본 논문에서는 디스크캐쉬 관리 기법의 하나인 동반쓰기 기법을 개선한 복합동반 쓰기 기법을 제안하고 그 성능을 평가하였다. 제안된 기법의 성능 평가를 위하여 디스 크 시스템을 모델화 하여 실제 디스크시스템에 근접한 시뮬레이션 모델을 구현하고 trace-driven 시뮬레이션을 수행하였다. 시뮬레이션의 결과 본 연구에서 제안된 복합 동반쓰기 기법이 기존의 동반쓰기 기법에 비하여 우수한 성능을 나타냄을 증명하였다.

  • PDF

차륜형 이동로봇 시스템의 하이브리드 시스템 모델과 제어 (An approach to hybrid system modeling and control for the mobile robot systems)

  • 임진모;임미섭;임준홍
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.231-236
    • /
    • 1997
  • We propose the hybrid control for the path control of wheeled mobile robot system. To develop the hybrid control of mobile robot, the continuous dynamics of mobile robot are modeled by the switched systems. The abstract model and digital automata for the path control are developed. This hybrid control system has the 3-layered hierachical structure : digital automata as the higher process, mobile robot system as the lower process, and the interface as the interaction process between the continuous dynamics and the discrete dynamics. The control of following the desired-paths with edges are investigated as the applications by the computer simulation.

  • PDF

상용차용 디젤엔진의 Engine ECU_ILS 시스템 개발 (Development of Engine ECU_ILS System for Diesel Engine of Commercial Vehicle)

  • 고영진
    • 한국자동차공학회논문집
    • /
    • 제22권5호
    • /
    • pp.35-43
    • /
    • 2014
  • The automobile industry requires technological innovations to reduce fuel consumption with the public interest in environmental conservation in recent years. Thus, the hybrid system is applied not only to passenger cars but also commercial vehicles. The purpose of this paper is to develop engine ECU_ILS to develop commercial hybrid vehicles. In order to develop the engine and vehicle, the dynamometer and exhaust gas analyzer is needed. However, a lot of time and cost are required. In contrast, the model-based development environment that can be applied to a variety of test conditions can reduce development time. Therefore, a HILS system environment that can consider the behavior of actual vehicles for evaluation of the control logic, fuel consumption and exhaust gas is required. This engine ECU_ILS system was developed in this study, can analyze parameter such as the fuel injection rate, fuel injection time, fuel consumption and exhaust gas like the actual vehicle test using map data. Also, this system is expected to be able to analyze the characteristic of vehicle behavior and the development of peripheral device in relation to engine and vehicles. This HILS system can be used to develop control strategies of commercial hybrid vehicle systems in the future.

X-By-Wire 시스템의 센서 결함 허용을 위한 Fuzzy Hybrid Redundancy 개발 (Development of Fuzzy Hybrid Redundancy for Sensor Fault-Tolerant of X-By-Wire System)

  • 김만호;손병점;이경창;이석
    • 제어로봇시스템학회논문지
    • /
    • 제15권3호
    • /
    • pp.337-345
    • /
    • 2009
  • The dependence of numerous systems on electronic devices is causing rapidly increasing concern over fault tolerance because of safety issues of safety critical system. As an example, a vehicle with electronics-controlled system such as x-by-wire systems, which are replacing rigid mechanical components with dynamically configurable electronic elements, should be fault¬tolerant because a devastating failure could arise without warning. Fault-tolerant systems have been studied in detail, mainly in the field of aeronautics. As an alternative to solve these problems, this paper presents the fuzzy hybrid redundancy system that can remove most erroneous faults with fuzzy fault detection algorithm. In addition, several numerical simulation results are given where the fuzzy hybrid redundancy outperforms with general voting method.