• 제목/요약/키워드: Hybrid Probe

검색결과 81건 처리시간 0.028초

자가적응모듈과 퍼지인식도가 적용된 하이브리드 침입시도탐지모델 (An Hybrid Probe Detection Model using FCM and Self-Adaptive Module)

  • 이세열
    • 디지털산업정보학회논문지
    • /
    • 제13권3호
    • /
    • pp.19-25
    • /
    • 2017
  • Nowadays, networked computer systems play an increasingly important role in our society and its economy. They have become the targets of a wide array of malicious attacks that invariably turn into actual intrusions. This is the reason computer security has become an essential concern for network administrators. Recently, a number of Detection/Prevention System schemes have been proposed based on various technologies. However, the techniques, which have been applied in many systems, are useful only for the existing patterns of intrusion. Therefore, probe detection has become a major security protection technology to detection potential attacks. Probe detection needs to take into account a variety of factors ant the relationship between the various factors to reduce false negative & positive error. It is necessary to develop new technology of probe detection that can find new pattern of probe. In this paper, we propose an hybrid probe detection using Fuzzy Cognitive Map(FCM) and Self Adaptive Module(SAM) in dynamic environment such as Cloud and IoT. Also, in order to verify the proposed method, experiments about measuring detection rate in dynamic environments and possibility of countermeasure against intrusion were performed. From experimental results, decrease of false detection and the possibilities of countermeasures against intrusions were confirmed.

Development of the DC-RF Hybrid Plasma Source

  • 김지훈;천세민;강인제;이헌주
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.213-213
    • /
    • 2011
  • DC arc plasmatron is powerful plasma source to apply etching and texturing processing. Even though DC arc plasmatron has many advantages, it is difficult to apply an industry due to the small applied area. To increase an effective processing area, we suggest a DC-RF hybrid plasma system. The DC-RF hybrid plasma system was designed and made. This system consists of a DC arc plasmatron, RF parts, reaction chamber, power feeder, gas control system and vacuum system. To investigate a DC-RF hybrid plasma, we used a Langmuir probe, OES (Optical emission spectroscopy), infrared (IR) light camera. For RF matching, PSIM software was used to simulate a current of an impedance coil. The results of Langmuir probe measurements, we obtain a homogeneous plasma density and electron temperature those are about $1{\times}1010$ #/cm3 and 1~4 eV. The DC-RF hybrid plasma source is applied for plasma etching experimental, and we obtain an etching rate of 10 ${\mu}m$/min. through a 90 mm of reaction chamber diameter.

  • PDF

Cutoff Probe를 이용한 자화유도결합 플라즈마의 특성 연구 (A Study on Magnetized Inductively Coupled Plasma Using Cutoff Probe)

  • 손의정;김동현;이호준
    • 전기학회논문지
    • /
    • 제65권10호
    • /
    • pp.1706-1711
    • /
    • 2016
  • Electromagnetic wave simulation was performed to predict characteristics of manufactured cutoff probe at low temperature magnetized plasma medium. Microwave cutoff probe is designed for research the properties of magnetized inductively coupled plasma. It was shown that the cutoff probe method can safely be used for weakly magnetized high density plasma sources. Cutoff probe system with two port network analyzer has been prepared and applied to measure electron density distributions in large area, 13.56MHz driven weakly magnetized inductively coupled plasma source. The results shown that, the plasma frequency confirmed cut-off characteristics in low temperature plasma. Especially, cut-off characteristics was found at upper hybrid resonance frequency in the environment of the magnetic field. In case of a induced weak magnetic field in inductively coupled plasma, plasma density estimated from the cutoff frequency in the same way at unmagnetized plasma due to nearly same plasma frequency and upper hybrid resonance frequency. The plasma density is increased and uniformity is improved by applying a induced weak magnetic field in inductively coupled plasma.

IT 시스템 장애탐지력 향상을 위한 하이브리드 모니터링 프레임워크 개발 (Development of hybrid monitoring framework for fault detectability enhancement on IT-System)

  • 박석환;손지성;백두권
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2012년도 추계학술발표대회
    • /
    • pp.1203-1206
    • /
    • 2012
  • 본 논문은 다양한 기기로 구성된 분산 IT 환경에서 보다 신속한 장애 탐지 및 원인 파악을 위한 Monitoring framework을 제안한다. 제안된 Framework은 전통적인 Event Correlation 기법과 전통적 기법의 문제점 해결을 위한 Probing 기법을 혼용한(Hybrid) 것인데, 이를 통해 각각의 기법이 지닌 한계를 극복하고, 장애탐지 능력을 향상시킨다. 즉, Event Correlation 기법은 임계영역에서 장애 판별이 어려운 문제점이 있는데, 이러한 경우 장애 여부를 확신하기 위해 Probe station을 이용하여 Probe를 실행함으로써 장애 판단 능력을 향상시켰다. 또한 Probing 기법은 복잡한 분산 IT 환경에서 Probe Set를 구성하는 어려움이 있는데, 이를 회피하는데 도움을 준다. 본 논문에서는 Web 기반 애플리케이션에서 User-Session을 기반으로 추출한 Http Packet를 Probe set으로 이용하여 구현하였다.

DNA Probes에 의한 토양의 이사디 (2,4-D) 분해세균의 검출 (Application of DNA Probe Method for Detection of 2,4-Dichlorophenoxyacetic Acid Degrading Bacteria in Soil)

  • 가종억
    • Applied Biological Chemistry
    • /
    • 제39권5호
    • /
    • pp.403-408
    • /
    • 1996
  • 토양에서 세균군집의 DNA를 추출하여 이사디 분해세균의 밀도와 군집변화를 tdfA 유전자와 Spa Probe를 이용하여 조사하였다. 이사디 분해균주인 Pseudomonas cepacia/pJP4을 토양에 여러 가지 밀도로 접종한 후 추출된 토양세균군집의 DNA를 Southern blot에서 분석한 결과, 본 실험에 사용된 DNA probe method에 의해 이 세균을 $10^5\;cells/g$ soil 수준까지 검출할 수 있는 것으로 나타났다. 이사디를 가해준 microcosm 토양에서 추출된 세균군집의 DNA를 분석한 실험에서는 Pseudemonas pickettii와 Sphingomonas Paucimobilis가 우점종으로 검출되었고, 사용된 두 가지의 DNA probes는 토양의 이사디 분해미생물에 대해 매우 높은 특이성을 가지고 있는 것으로 나타났다. 밭에 이사디를 장기 적으로 가해준 후 추출된 토양세균군집의 DNA를 분석 한 실험에서는 이사디를 최소한 10 ppm 이상 가해주어야 토양의 이사디 분해세균을 DNA probe method에 의해 검출할 수 있었고, tfdA 유전자는 실제의 밭토양에서도 높은 특이성을 나타냈으나 Spa probe는 일부의 토착세균에 비특이적으로 반응하는 것으로 나타났다. 토양에서 추출된 세균군집의 DNA를 분석하는 DNA probe method는 Southern blot과 함께 사용되었을 때 토양에 존재하는 이사디 분해미생물을 실험실 배지에 배양하지 않고 검출할 수 있었고,이 미생물들의 밀도, 군집변화, 유전적 변화 등을 효과적으로 분석할 수 있는 것으로 나타났다.

  • PDF

옥수수 $\alpha$-amylase 유전자의 클로닝 (Cloning of $\alpha$-Amylase Gene from Zea mays)

  • 김용욱;강신혜
    • 한국작물학회지
    • /
    • 제38권3호
    • /
    • pp.275-282
    • /
    • 1993
  • 본 연구는 한국 옥수수의 $\alpha$-amylase의 유전자 클로닝을 주된 목표로 하여 수행되었다. 이를 위하여 여러 식물체의 $\alpha$-amylase 염기서열로 부터 잘 보존된 부분을 참고로 oligonucleotlde probe 및 PCR primer를 설계, 합성하고, 옥수수의 유묘로부터 전체 RNA를 분리하여 northern blot analysis를 통하여 확인한 다음, 이로부터 첫 번째 가닥 cDNA를 만든 후, 여기서 얻은 RNA : DNA hybrid를 주형으로 한 polymerase chain reaction을 통하여 길이 가 약 500bp되 는 PCR 산물을 얻었다. 이를 클로닝하기 위해 pUC19을 클로닝 백터로 사용하여 재조합 플라스미드인 $\ulcorner$pZM$\alpha$'$\lrcorner$를 만들었다. 합성 probe를 이용, Southern blot analysis한 결과, $\ulcorner$pZM$\alpha$'$\lrcorner$가 옥수수 mRNA로 부터 증폭된 DNA의 일부분을 갖고 있음을 확인하였으며, 그 길이는 PCR 산물과 같은 500bp가량 되는 것으로 나타났다.

  • PDF

Design of Hybrid Network Probe Intrusion Detector using FCM

  • Kim, Chang-Su;Lee, Se-Yul
    • Journal of information and communication convergence engineering
    • /
    • 제7권1호
    • /
    • pp.7-12
    • /
    • 2009
  • The advanced computer network and Internet technology enables connectivity of computers through an open network environment. Despite the growing numbers of security threats to networks, most intrusion detection identifies security attacks mainly by detecting misuse using a set of rules based on past hacking patterns. This pattern matching has a high rate of false positives and can not detect new hacking patterns, making it vulnerable to previously unidentified attack patterns and variations in attack and increasing false negatives. Intrusion detection and prevention technologies are thus required. We proposed a network based hybrid Probe Intrusion Detection model using Fuzzy cognitive maps (PIDuF) that detects intrusion by DoS (DDoS and PDoS) attack detection using packet analysis. A DoS attack typically appears as a probe and SYN flooding attack. SYN flooding using FCM model captures and analyzes packet information to detect SYN flooding attacks. Using the result of decision module analysis, which used FCM, the decision module measures the degree of danger of the DoS and trains the response module to deal with attacks. For the performance evaluation, the "IDS Evaluation Data Set" created by MIT was used. From the simulation we obtained the max-average true positive rate of 97.064% and the max-average false negative rate of 2.936%. The true positive error rate of the PIDuF is similar to that of Bernhard's true positive error rate.

잉어 $\beta$-globin 유전자의 염색체상에서의 다형해석 (Polymorphism of Carp $\beta$-globin Gene on Chromosome)

  • 진덕희;청목주
    • 생명과학회지
    • /
    • 제8권3호
    • /
    • pp.348-351
    • /
    • 1998
  • Common DNA fragments of the ${\beta}$-globin gene were observed from six races of the adult common carp: Hybrid-Yamato, Japanese wild type, Mirror, Suwa-Yamato, Scale German, and Saku-Yamato. Chromosomal DNAs isolated from the above six races were digested with restriction endonucleased EcoRI and PstI. The digested fragments were transferred onto nitrocellulose filter and hybridized with a probe of carp ${\beta}$-globin cDNA. Molecular sizes of the hybridized DNA fragments digested with EcoRI were 3.6Kb(Kilo base), 4.3Kb and 15Kb in Hybrid-Yamato, Japanese wild type, Mirror, Scale German and Saku-Yamato carp DNAs. In Scale German and Saku-Yamato carp DNAs, two and one more hybridized DNA fragments were observed, respectively. Molecular sizes of the hybridized DNA fragments digested with PstI were 2.2Kb, 6.5Kb, 7.8Kb and 9.2Kb in Hybrid-Yamato, 2.2Kb, 6.5Kb and 9.2Kb in Japanese wild type, 2.2Kb, 6.5Kb, 7.8Kb, and 13Kb in Mirror, 2,2Kb, 5,5Kb, 6.5Kb, 7.8Kb, 9.2Kb and13Kb in Scale German, and 2.2Kb, 5.5Kb, 6.5Kb, 9.2Kb and Saku-Yamato carp DNA. Therefore, depending on carps, three to six DNA fragments were hybridized with ${\beta}$-globin gene probe. Thus it indicated polymorphysm in the globin gene family of carp.

  • PDF

Monitoring Cathodic Shielding and Corrosion under Disbonded Coatings

  • Varela, F.;Tan, M. YJ;Hinton, B.;Forsyth, M.
    • Corrosion Science and Technology
    • /
    • 제16권3호
    • /
    • pp.109-114
    • /
    • 2017
  • Monitoring of corrosion is in most cases based on simulation of environmental conditions on a large and complex structure such as a buried pipeline using a small probe, and the measurement of thermodynamics and kinetics of corrosion processes occurring on the probe surface. This paper presents a hybrid corrosion monitoring probe designed for simulating deteriorating conditions wrought by disbonded coatings and for measuring current densities and distribution of such densities on a simulated pipeline surface. The concept of the probe was experimentally evaluated using immersion tests under cathodic protection (CP) in high resistivity aqueous solution. Underneath the disbonded area, anodic currents and cathodic currents were carefully measured. Anodic current densities were used to calculate metal loss according to Faraday's law. Calculated corrosion patterns were compared with corrosion damage observed at the surface of the probe after a series of stringent tests. The capability of the probe to measure anodic current densities under CP, without requiring interruption, was demonstrated in high resistivity aqueous solution. The pattern of calculated metal loss correlated well with corrosion products distribution observed at the array surface. Working principles of the probe are explained in terms of electrochemistry.

연약지반의 강성도 측정을 위한 관입형 벤더 엘리먼트 프로브의 개발 및 적용 (Development and Application of Penetration-type Bender Elements Probe for Stiffness Measurements of Soft Soils)

  • 목영진;정재우;김학성
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.119-126
    • /
    • 2008
  • Ground stiffness(shear wave velocity) is one of the key parameters in geotechnical earthquake engineering. An In-situ seismic technique has its own advantages and disadvantages over the others in stiffness measurements. By combining the crosshole and seismic cone techniques and utilizing favourable features of bender elements, a new hybrid probe has been developed in order to enhance data quality and easiness of testing. The basic structure of the probe, called "MudFork", is a fork composed of two blades, on each of which source and receiver bender elements were mounted respectively. To evaluate the disturbance caused by the penetration of the probe, shear wave velocity measurements were carried out in the Kaolinite slurry in the laboratory. Finally, the probe was penetrated in coastal mud near Incheon, Korea, using SPT(standard penetration test)rods pushed with a routine boring machine and shear wave velocity measurements were carried out. The results were verified with data from laboratory and cone testing. The performance of the probe turns out to be excellent in terms of data quality and testing convenience.

  • PDF