• Title/Summary/Keyword: Hybrid Probe

Search Result 81, Processing Time 0.027 seconds

An Hybrid Probe Detection Model using FCM and Self-Adaptive Module (자가적응모듈과 퍼지인식도가 적용된 하이브리드 침입시도탐지모델)

  • Lee, Seyul
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.13 no.3
    • /
    • pp.19-25
    • /
    • 2017
  • Nowadays, networked computer systems play an increasingly important role in our society and its economy. They have become the targets of a wide array of malicious attacks that invariably turn into actual intrusions. This is the reason computer security has become an essential concern for network administrators. Recently, a number of Detection/Prevention System schemes have been proposed based on various technologies. However, the techniques, which have been applied in many systems, are useful only for the existing patterns of intrusion. Therefore, probe detection has become a major security protection technology to detection potential attacks. Probe detection needs to take into account a variety of factors ant the relationship between the various factors to reduce false negative & positive error. It is necessary to develop new technology of probe detection that can find new pattern of probe. In this paper, we propose an hybrid probe detection using Fuzzy Cognitive Map(FCM) and Self Adaptive Module(SAM) in dynamic environment such as Cloud and IoT. Also, in order to verify the proposed method, experiments about measuring detection rate in dynamic environments and possibility of countermeasure against intrusion were performed. From experimental results, decrease of false detection and the possibilities of countermeasures against intrusions were confirmed.

Development of the DC-RF Hybrid Plasma Source

  • Kim, Ji-Hun;Cheon, Se-Min;Gang, In-Je;Lee, Heon-Ju
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.213-213
    • /
    • 2011
  • DC arc plasmatron is powerful plasma source to apply etching and texturing processing. Even though DC arc plasmatron has many advantages, it is difficult to apply an industry due to the small applied area. To increase an effective processing area, we suggest a DC-RF hybrid plasma system. The DC-RF hybrid plasma system was designed and made. This system consists of a DC arc plasmatron, RF parts, reaction chamber, power feeder, gas control system and vacuum system. To investigate a DC-RF hybrid plasma, we used a Langmuir probe, OES (Optical emission spectroscopy), infrared (IR) light camera. For RF matching, PSIM software was used to simulate a current of an impedance coil. The results of Langmuir probe measurements, we obtain a homogeneous plasma density and electron temperature those are about $1{\times}1010$ #/cm3 and 1~4 eV. The DC-RF hybrid plasma source is applied for plasma etching experimental, and we obtain an etching rate of 10 ${\mu}m$/min. through a 90 mm of reaction chamber diameter.

  • PDF

A Study on Magnetized Inductively Coupled Plasma Using Cutoff Probe (Cutoff Probe를 이용한 자화유도결합 플라즈마의 특성 연구)

  • Son, Eui-Jeong;Kim, Dong-Hyun;Lee, Ho-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.10
    • /
    • pp.1706-1711
    • /
    • 2016
  • Electromagnetic wave simulation was performed to predict characteristics of manufactured cutoff probe at low temperature magnetized plasma medium. Microwave cutoff probe is designed for research the properties of magnetized inductively coupled plasma. It was shown that the cutoff probe method can safely be used for weakly magnetized high density plasma sources. Cutoff probe system with two port network analyzer has been prepared and applied to measure electron density distributions in large area, 13.56MHz driven weakly magnetized inductively coupled plasma source. The results shown that, the plasma frequency confirmed cut-off characteristics in low temperature plasma. Especially, cut-off characteristics was found at upper hybrid resonance frequency in the environment of the magnetic field. In case of a induced weak magnetic field in inductively coupled plasma, plasma density estimated from the cutoff frequency in the same way at unmagnetized plasma due to nearly same plasma frequency and upper hybrid resonance frequency. The plasma density is increased and uniformity is improved by applying a induced weak magnetic field in inductively coupled plasma.

Development of hybrid monitoring framework for fault detectability enhancement on IT-System (IT 시스템 장애탐지력 향상을 위한 하이브리드 모니터링 프레임워크 개발)

  • Park, Sok-Hwan;Son, Jiseong;Baik, Doo-Kwon
    • Annual Conference of KIPS
    • /
    • 2012.11a
    • /
    • pp.1203-1206
    • /
    • 2012
  • 본 논문은 다양한 기기로 구성된 분산 IT 환경에서 보다 신속한 장애 탐지 및 원인 파악을 위한 Monitoring framework을 제안한다. 제안된 Framework은 전통적인 Event Correlation 기법과 전통적 기법의 문제점 해결을 위한 Probing 기법을 혼용한(Hybrid) 것인데, 이를 통해 각각의 기법이 지닌 한계를 극복하고, 장애탐지 능력을 향상시킨다. 즉, Event Correlation 기법은 임계영역에서 장애 판별이 어려운 문제점이 있는데, 이러한 경우 장애 여부를 확신하기 위해 Probe station을 이용하여 Probe를 실행함으로써 장애 판단 능력을 향상시켰다. 또한 Probing 기법은 복잡한 분산 IT 환경에서 Probe Set를 구성하는 어려움이 있는데, 이를 회피하는데 도움을 준다. 본 논문에서는 Web 기반 애플리케이션에서 User-Session을 기반으로 추출한 Http Packet를 Probe set으로 이용하여 구현하였다.

Application of DNA Probe Method for Detection of 2,4-Dichlorophenoxyacetic Acid Degrading Bacteria in Soil (DNA Probes에 의한 토양의 이사디 (2,4-D) 분해세균의 검출)

  • Ka, Jong-Ok
    • Applied Biological Chemistry
    • /
    • v.39 no.5
    • /
    • pp.403-408
    • /
    • 1996
  • Total bacterial community DNA, which was extracted from microcosm soil and field soil after 2,4-D amendments, was analyzed on Southern blots, using the tfdA gene probe derived from plasmid pJP4 and the Spa probe from Sphingomonas paucimobilis. Southern blot analyses with total bacterial DNA extracted from soils Inoculated with Pseudomonas cepacia/pJP4 revealed that DNA probe method could detect the 2,4-D degrading bacteria down to $10^5\;cells/g$ dry soil. In the microcosm experiment, there was a good correlation between 2,4-D degradation and banding patterns in hybridization analyses performed after each 2,4-D treatment using the two probes. When bacterial DNA extracted from microcosm soil was hybridized with the Spa probe, a change in the position of hybrid bands was observed over time in a Southern blot, suggesting that population change or possibly genetic rearrangement in 2,4-D degrading microbial populations occurred in this soil. With the Spa probe, one hybrid DNA band was persistently observed throughout the five 2,4-D additions. When bacterial DNA isolated from the field soil was probed with the tfdA and Spa, strong hybridization signal was observed in the 100 ppm-treated subplot, weak signal In the 10 ppm-treated subplot, and no significant signal in the 1 ppm-treated and control subplots. The data show that DNA probe analyses were capable of detecting and discriminating the indigenous 2,4-D degrading microbial populations in soil amended with 2,4-D under laboratory and field conditions.

  • PDF

Cloning of $\alpha$-Amylase Gene from Zea mays (옥수수 $\alpha$-amylase 유전자의 클로닝)

  • 김용욱;강신혜
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.38 no.3
    • /
    • pp.275-282
    • /
    • 1993
  • The objective of this study was to clone a partial fragment of $\alpha$-amylase from Korean maize. We designed and synthesized an oligonucleotide probe and two kinds of PCR primers based on cDNA conserved region of $\alpha$-amylase sequences from other plants. Total RNA from 3-day-old maize seedling was used as template for 1st strand cDNA synthesis and RNA-DNA hybrid was used as template for polymerase chain reaction(PCR). The product of PCR was about 0.5 kb long and inserted into pUC19. We named this recombinant plasmid as pZM$\alpha$'. The cloned fragment was certified by Southern blot analysis using labeled synthetic oligonucleotide as probe.

  • PDF

Design of Hybrid Network Probe Intrusion Detector using FCM

  • Kim, Chang-Su;Lee, Se-Yul
    • Journal of information and communication convergence engineering
    • /
    • v.7 no.1
    • /
    • pp.7-12
    • /
    • 2009
  • The advanced computer network and Internet technology enables connectivity of computers through an open network environment. Despite the growing numbers of security threats to networks, most intrusion detection identifies security attacks mainly by detecting misuse using a set of rules based on past hacking patterns. This pattern matching has a high rate of false positives and can not detect new hacking patterns, making it vulnerable to previously unidentified attack patterns and variations in attack and increasing false negatives. Intrusion detection and prevention technologies are thus required. We proposed a network based hybrid Probe Intrusion Detection model using Fuzzy cognitive maps (PIDuF) that detects intrusion by DoS (DDoS and PDoS) attack detection using packet analysis. A DoS attack typically appears as a probe and SYN flooding attack. SYN flooding using FCM model captures and analyzes packet information to detect SYN flooding attacks. Using the result of decision module analysis, which used FCM, the decision module measures the degree of danger of the DoS and trains the response module to deal with attacks. For the performance evaluation, the "IDS Evaluation Data Set" created by MIT was used. From the simulation we obtained the max-average true positive rate of 97.064% and the max-average false negative rate of 2.936%. The true positive error rate of the PIDuF is similar to that of Bernhard's true positive error rate.

Polymorphism of Carp $\beta$-globin Gene on Chromosome (잉어 $\beta$-globin 유전자의 염색체상에서의 다형해석)

  • 진덕희;청목주
    • Journal of Life Science
    • /
    • v.8 no.3
    • /
    • pp.348-351
    • /
    • 1998
  • Common DNA fragments of the ${\beta}$-globin gene were observed from six races of the adult common carp: Hybrid-Yamato, Japanese wild type, Mirror, Suwa-Yamato, Scale German, and Saku-Yamato. Chromosomal DNAs isolated from the above six races were digested with restriction endonucleased EcoRI and PstI. The digested fragments were transferred onto nitrocellulose filter and hybridized with a probe of carp ${\beta}$-globin cDNA. Molecular sizes of the hybridized DNA fragments digested with EcoRI were 3.6Kb(Kilo base), 4.3Kb and 15Kb in Hybrid-Yamato, Japanese wild type, Mirror, Scale German and Saku-Yamato carp DNAs. In Scale German and Saku-Yamato carp DNAs, two and one more hybridized DNA fragments were observed, respectively. Molecular sizes of the hybridized DNA fragments digested with PstI were 2.2Kb, 6.5Kb, 7.8Kb and 9.2Kb in Hybrid-Yamato, 2.2Kb, 6.5Kb and 9.2Kb in Japanese wild type, 2.2Kb, 6.5Kb, 7.8Kb, and 13Kb in Mirror, 2,2Kb, 5,5Kb, 6.5Kb, 7.8Kb, 9.2Kb and13Kb in Scale German, and 2.2Kb, 5.5Kb, 6.5Kb, 9.2Kb and Saku-Yamato carp DNA. Therefore, depending on carps, three to six DNA fragments were hybridized with ${\beta}$-globin gene probe. Thus it indicated polymorphysm in the globin gene family of carp.

  • PDF

Monitoring Cathodic Shielding and Corrosion under Disbonded Coatings

  • Varela, F.;Tan, M. YJ;Hinton, B.;Forsyth, M.
    • Corrosion Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.109-114
    • /
    • 2017
  • Monitoring of corrosion is in most cases based on simulation of environmental conditions on a large and complex structure such as a buried pipeline using a small probe, and the measurement of thermodynamics and kinetics of corrosion processes occurring on the probe surface. This paper presents a hybrid corrosion monitoring probe designed for simulating deteriorating conditions wrought by disbonded coatings and for measuring current densities and distribution of such densities on a simulated pipeline surface. The concept of the probe was experimentally evaluated using immersion tests under cathodic protection (CP) in high resistivity aqueous solution. Underneath the disbonded area, anodic currents and cathodic currents were carefully measured. Anodic current densities were used to calculate metal loss according to Faraday's law. Calculated corrosion patterns were compared with corrosion damage observed at the surface of the probe after a series of stringent tests. The capability of the probe to measure anodic current densities under CP, without requiring interruption, was demonstrated in high resistivity aqueous solution. The pattern of calculated metal loss correlated well with corrosion products distribution observed at the array surface. Working principles of the probe are explained in terms of electrochemistry.

Development and Application of Penetration-type Bender Elements Probe for Stiffness Measurements of Soft Soils (연약지반의 강성도 측정을 위한 관입형 벤더 엘리먼트 프로브의 개발 및 적용)

  • Mok, Young-Jin;Jung, Jae-Woo;Kim, Hak-Sung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.119-126
    • /
    • 2008
  • Ground stiffness(shear wave velocity) is one of the key parameters in geotechnical earthquake engineering. An In-situ seismic technique has its own advantages and disadvantages over the others in stiffness measurements. By combining the crosshole and seismic cone techniques and utilizing favourable features of bender elements, a new hybrid probe has been developed in order to enhance data quality and easiness of testing. The basic structure of the probe, called "MudFork", is a fork composed of two blades, on each of which source and receiver bender elements were mounted respectively. To evaluate the disturbance caused by the penetration of the probe, shear wave velocity measurements were carried out in the Kaolinite slurry in the laboratory. Finally, the probe was penetrated in coastal mud near Incheon, Korea, using SPT(standard penetration test)rods pushed with a routine boring machine and shear wave velocity measurements were carried out. The results were verified with data from laboratory and cone testing. The performance of the probe turns out to be excellent in terms of data quality and testing convenience.

  • PDF