• 제목/요약/키워드: Hybrid Damper

검색결과 141건 처리시간 0.023초

하이브리드 면진장치의 뉴로-퍼지 모형화 (Neuro-Fuzzy Modeling Approach for Hybrid Base Isolaton System)

  • 김현수;;이동근
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.201-208
    • /
    • 2005
  • Neuro-Fuzzy modeling approach is proposed to predict the dynamic behavior of a single-degree-of-freedom structure that is equipped with hybrid base isolation system. Hybrid base isolation system consists of friction pendulum systems (FPS) and a magnetorheological (MR) damper. Fuzzy model of the M damper is trained by ANFIS using various displacement, velocity, and voltage combinations that are obtained from a series of performance tests. Modelling of the FPS is carried out with a nonlinear analytical equation that is derived in this study and neuro-fuzzy training. Fuzzy logic controller is employed to control the command voltage that is sent to MR damper. The dynamic responses or experimental structure subjected to various earthquake excitations are compared with numerically simulated results using neuro-fuzzy modeling method. Numerical simulation using neuro-fuzzy models of the MR damper and FPS predict response of the hybrid base isolation system very well.

  • PDF

Optimum distribution of steel slit-friction hybrid dampers based on life cycle cost

  • Eldin, Mohamed Nour;Kim, Jaegoo;Kim, Jinkoo
    • Steel and Composite Structures
    • /
    • 제27권5호
    • /
    • pp.633-646
    • /
    • 2018
  • This study investigated the seismic performance of a hybrid damper composed of a steel slit plate and friction pads, and an optimum retrofit scheme was developed based on life cycle cost. A sample hybrid damper was tested under cyclic loading to confirm its validity as a damping device and to construct its nonlinear analysis model. The effectiveness of the optimum damper distribution schemes was investigated by comparing the seismic fragility and the life cycle costs of the model structure before and after the retrofit. The test results showed that the damper behaved stably throughout the loading history. Numerical analysis results showed that the slit-friction hybrid dampers optimally distributed based on life cycle cost proved to be effective in minimizing the failure probability and the repair cost after earthquakes.

점탄성-슬릿 복합댐퍼로 보강된 건물의 내진성능평가 (Seismic Performance Evaluation of Structures Retrofitted with Viscoelastic-Slit Hybrid Dampers)

  • 김민성;자오동쉬;김진구
    • 한국지진공학회논문집
    • /
    • 제22권7호
    • /
    • pp.361-367
    • /
    • 2018
  • This study investigates the seismic performance of a hybrid seismic energy dissipation device composed of a viscoelastic damper and a steel slit damper connected in parallel. A moment-framed structure is designed without seismic load and is retrofitted with the hybrid dampers. The model structure is transformed into an equivalent simplified system to find out optimum story-wise damper distribution pattern using genetic algorithm. The effectiveness of the hybrid damper is investigated by fragility analysis of the structure with and without the dampers. The analysis results show that after seismic retrofit the probability of reaching damage states, especially the complete damage state, of the structure turn out to be significantly reduced.

복합구조 댐퍼를 적용한 고 감쇠 폴리머 콘크리트의 진동 특성에 관한 연구 (Vibrational Properties of High Damping Polymer Concrete with Hybrid Damper)

  • 김정진;최경석;위준우;석원균
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제24권5호
    • /
    • pp.135-142
    • /
    • 2020
  • 구조물을 구성하고 있는 콘크리트의 경우, 진동에 대한 감쇠성능이 작아, 구조물에서 발생하는 다양한 진동 문제를 해결하는데 어려움이 있으므로, 이러한 문제를 해결하기 위해, 최근 폴리머 콘크리트와 복합구조 댐퍼를 혼합하여 댐핑 성능을 크게 증가시킨 고 감쇠 시스템에 대한 연구가 활발히 진행되고 있다. 한편, 폴리머 콘크리트는 배합 시, 시멘트와 물을 사용하지 않아, 경화시간이 매우 짧고, 물리적 특성 및 동특성 등이 매우 우수하여 진동저감이 요구되는 건축구조물에의 폭넓은 활용이 기대되는 구조재료이며, 복합구조 댐퍼는 파이프 관 내부에 위치한 쇠구슬의 충돌에 따른 운동에너지 소산과 점성유체의 에너지 소산 방식을 통해 진동을 저감하는 구조시스템이라 할 수 있다. 본 연구에서는 폴리머 콘크리트와 복합구조 댐퍼의 물리적, 동적 특성을 일반 콘크리트와 비교하였는데, 물리적 특성의 경우, 폴리머 콘크리트가 탄성계수 및 강도 특성에서 상당히 우수한 결과를 보였으며, 특히 인장강도는 6.5~10배 이상 큰 차이를 보였다. 또한, 동적 특성의 경우도 폴리머 콘크리트는 일반 콘크리트 대비 동적강성은 25%, 감쇠비는 약 3배 정도 증가하였으며, 복합구조 댐퍼는 동적강성은 비슷한 경향을 보였지만 감쇠비는 3.5배 이상 증가하여, 일반 콘크리트보다 진동 감쇠성능이 우수한 것으로 나타났다.

반능동 현가장치의 하이브리드형 댐퍼 개발에 관한 연구 (Development and Evaluation of a Hybrid Damper for Semi-active Suspension)

  • 진철호;윤영원;이재학
    • 드라이브 ㆍ 컨트롤
    • /
    • 제15권1호
    • /
    • pp.38-49
    • /
    • 2018
  • This research describes the development model and testing of a hybrid damper which can be applicable to a vehicle suspension. The hybrid damper is devised to improve the performance of a conventional passive oil damper using a magneto-rheological (MR) accumulator which consists of a gas accumulator and a MR device. The level of damping is continuously variable by the means of control in the applied current in a MR device fitted to a floating piston which separates the gas and the oil chamber. A simple MR device is used to resist the movement of floating piston. At first a mathematical model which describes all flows within the conventional oil damper is formulated, and then a small MR device is also devised and adopted to a mathematical model to characterize the performance of the device.

Control of a building complex with Magneto-Rheological Dampers and Tuned Mass Damper

  • Amini, F.;Doroudi, R.
    • Structural Engineering and Mechanics
    • /
    • 제36권2호
    • /
    • pp.181-195
    • /
    • 2010
  • Coupled building control is a viable method to protect tall buildings from seismic excitation. In this study, the semi-active control of a building complex is investigated for mitigating seismic responses. The building complex is formed of one main building and one podium structure connected through Magneto-Rheological (MR) Dampers and Tuned Mass Damper. The conventional semi-active control techniques require a primary controller as a reference to determine the desired control force, and modulate the input voltage of the MR damper by comparing the desired control force. The fuzzy logic directly determines the input voltage of an MR damper from the response of the MR damper. The control performance of the proposed fuzzy control technique for the MR damper is evaluated for the control problem of a seismically-excited building complex. In this paper, a building complex that include a 14-story main building and an 8-story podium structure is applied as a numerical example to demonstrate the effectiveness of semi-active control with Magneto-Rheological dampers and its comparison with the passive control with the Tuned Mass Damper and two uncoupled buildings and hybrid semi-active control including the Tuned Mass Damper and Magneto-Rheological dampers while they are subject to the earthquake excitation. The numerical results show that semi-active control and hybrid semi-active control can significantly mitigate the seismic responses of both buildings, such as displacement and shear force responses, and fuzzy control technique can effectively mitigate the seismic response of the building complex.

건축 구조물의 진동 제어용 하이브리드형 대용량 리니어 모터 댐퍼의 개발 (Development of a Large Capacity Hybrid-Type Linear Motor Damper for the vibration Control of Building Structures)

  • 정상섭;장석명;이성호;윤인기
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권11호
    • /
    • pp.601-611
    • /
    • 2002
  • As resent trends in structural construction have been to build taller and larger structures than any time in the past, they have had high flexibility and low damping that can cause large vibration response under severe environmental loading such as earthquakes, winds, and mechanical excitations. The damper with mass and sqring is one aproach to safeguarding the structure against excessive vibrations. In this paper, a large capacity hybrid-type linear motor damper(LMD) was designed and fabricated for the application to the vibration control of a large building structure model. It has been designed to be able to move the damper mass, 1,500 kg up to ${\pm}250mm$ strokes at the first mode natural frequency of the building structure model, ${\pm}0.51Hz$. Linear motor is consisted of the fixed coil and the movable NdFeB permanent magnets field part. The PM field part composed magnet modules and iron yoke, is the damper mass itself, 1500kg. LMD therefore has a simplified structure and requires a few elements in the driving system, being compared with a rotary motor damper and a hydraulic damper. However, the manufacture of large PM linear actuator is difficult because of the limit of PM size and the attraction and repulsion at the assembly of PM. Therefore, large damper system is manufactured and tested for dynamic characteristics and frequency response.

실시간 하이브리드 실험법을 이용한 대형 MR감쇠기의 제진 성능평가 (Performance Evaluation of a Large-scale MR Damper for Controlling Seismic Response using a Real-time Hybrid Test Method)

  • 정희산;이성경;박은천;윤경조;민경원;이헌재;최강민;문석준;정형조
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.655-660
    • /
    • 2007
  • This paper presents real-time hybrid test method of large-scale MR damper applied to a building structure under seismic excitation. The real-time hybrid test using an actuator for the control performance evaluation of a MR damper controlling the response of earthquake-excited building structure is experimentally implemented. In the test, the building structure is used as a numerical part, on which a large-scale MR damper adopted as an experimental part was installed to reduce its response. At first, the force that is acting between a MR damper and building structure is measured from the load cell attached on the actuator system and is fed-back to the computer to control the motion of the actuator. Then, the actuator is so driven that the error between the interface displacement computed from the numerical building structure with the excitations of earthquake and the fed-back interface force and that measured from the actuator. The control efficiency of the MR damper used in this paper is experimentally confirmed by implementing this process of experiment on real-time.

  • PDF

MR 감쇠기와 FPS를 이용한 하이브리드 면진장치의 수치해석적 연구 (Numerical Study of Hybrid Base-isolator with Magnetorheological Damper and Friction Pendulum System)

  • 김현수
    • 한국지진공학회논문집
    • /
    • 제9권2호통권42호
    • /
    • pp.7-15
    • /
    • 2005
  • 본 연구에서는 하이브리드 면진장치가 설치된 단자유도 구조물의 동적거동을 예측할 수 있는 수치해석모델을 제안한다. 하이브리드 면진장치는 MR 감쇠기와 마찰진자시스템(FPS)으로 구성된다. MR감쇠기의 동적거동을 모형화하기 위하여 뉴로-퍼지 모델을 사용한다. 다양한 변위, 속도, 전압의 조합을 사용하여 MR 감쇠기의 성능실험을 수행한 후 얻어진 데이터를 이용하여 MR 감쇠기 뉴로-퍼지 모델을 ANFIS로 학습시킨다. FPS의 모형화는 본 연구에서 유도한 비선형 모델식에 근거하여 뉴로-퍼지 모형화방법을 사용하여 이루어진다. 본 연구에서는 MR 감쇠기로 전달되는 제어전압을 조절하기 위하여 퍼지논리제어기를 사용한다. 다양한 지진하중을 사용한 진동대 실험을 통하여 얻은 실험체의 동적응답과와 뉴로-퍼지 모형화방법을 사용한 수치해석의 결과를 비교한다. 뉴로-퍼지 모델을 사용하여 MR 감쇠기와 FPS를 모형화해서 수치해석을 수행한 결과 하이브리드 면진장치의 동적거동을 매우 정확하게 예측할 수 있었다.

실시간 하이브리드 실험법을 이용한 대형 MR감쇠기의 제진 성능평가 (Performance Evaluation of a Large-scale MR Damper for Controlling Seismic Responses Using a Real-time Hybrid Test Method)

  • 박은천;이성경;윤경조;정희산;이헌재;최강민;문석준;정형조;민경원
    • 한국소음진동공학회논문집
    • /
    • 제18권1호
    • /
    • pp.131-138
    • /
    • 2008
  • This paper presents real-time hybrid test method of large-scale MR damper applied to a building structure under seismic excitation. The real-time hybrid test using an actuator for the control performance evaluation of a MR damper controlling the response of earthquake-excited building structure is experimentally implemented. In the test, the building structure is used as a numerical part, on which a large-scale MR damper adopted as an experimental part was installed to reduce its response. At first, the force that is acting between a MR damper and building structure is measured from the load cell attached on the actuator system and is fed-back to the computer to control the motion of the actuator. Then, the actuator is so driven that the error between the interface displacement computed from the numerical building structure with the excitations of earthquake and the fed-back interface force and that measured from the actuator. The control efficiency of the MR damper used in this paper is experimentally confirmed by implementing this process of experiment on real-time.