• Title/Summary/Keyword: Hvdc

Search Result 630, Processing Time 0.038 seconds

The Cold Welding Properties for Al Wire of Aged Overhead Conductor (폐가공송전선 Al선재 냉간접합 특성)

  • Kim, Shang-Shu;Ku, Jae-Kwan;Lee, Young-Ho;Kim, Byung-Geol
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.5
    • /
    • pp.415-420
    • /
    • 2013
  • The new recycling technology for aged Aluminum wires in overhead conductor have been carried out. We are attempting to develop remanufacturing method for them for more effective way of recycling in stead of its conventional remelting process. The weld of aged aluminum wires play a vital role in remanufacture process. The paper investigates the mechanical properties during cold welding process of aged Aluminum wire. The tensile tests and microscopic analysis results are discussed to underscore the hardening features of welded aluminum wire. Various graphs are presented accompanied by discussion about their relevance on the process.

On Enhancement of EMT Simulation capability in Distributed Computing (전자기과도현상 프로그램의 전력계통 모의능력 향상에 관한 연구)

  • Oh, Sea-Seung;Lee, Han-Sang;Jang, Gil-Soo;Moon, Seung-Il
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.518-519
    • /
    • 2008
  • 전력계통에 FACTS, HVDC등의 전력전자 설비들이 도입되면서 실효치기반의 모의중심이었던 계통해석에 순시치기반의 모의를 사용하고자 하는 노력이 계속되어 왔지만 짧은 적분간격과 소자단위 모델링, 초기화의 어려움 등으로 인해 전력계통해석 중심의 어플리케이션에 적용하기에는 상대적으로 제약이 많았다. 본 논문에서는 상용 전자기과도현상 모의프로그램을 이용해 전력전자설비를 포함하는 전력계통을 보다 상세히 모델링하여 모의할 수 있는 방법을 제안하고자 한다.

  • PDF

Impact on Thermal Generator's Operation of Increased Wind Power Penetration in Jeju Island (제주도 풍력발전 점유율 증가에 따른 발전 설비 이용률 분석 연구)

  • Park, Jin-Woo;Pyo, Gi-Chan;Choi, Jung-Hyun;Moon, Seung-Il;Lee, Sung-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1164-1165
    • /
    • 2008
  • 풍력발전을 활성화하기 위한 정부차원의 노력과 제주 지자체의 의지, 그리고 새로운 사업 기회를 찾기 위한 풍력발전 사업자들의 의향 등으로 현재 제주 지역에는 많은 풍력발전의 증가가 예상되고 있다. 동시에 향후 3$\sim$4년 안에 예정되어 있는 제주 계통의 여러 변화들 - 대형 LNG 발전소의 신설 및 신규 HVDC의 건설 - 등과 맞물려 풍력발전 증가에 따른 영향을 분석해볼 필요가 있다. 본 연구에서는 2012년 제주 계통의 변화를 예상해보고 여러 시나리오에 걸쳐 발전 설비를 운용하는 조합을 선정해보았다. 그리고 각 경우의 발전설비 이용률을 검토해 보았다.

  • PDF

The 2nd Jeju HVDC Construction Feasibility & Reasionable Generation Resource Mix Overview (제주 추가 직류연계선 건설 타당성 및 합리적인 발전원 MIX 전망 검토)

  • Park, Jin-Hong;Moon, Bong-Su;Lee, Ho-Yong;Choi, Jae-Myeong
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.121-122
    • /
    • 2008
  • 우리나라의 가장 큰 섬인 제주도는 육지계통과 연결된 직류연계선 및 제주도내 발전기를 이용하여 전력을 공급받고 있다. 정부와 우리 한전은 제주도의 지속적인 전력수요 증가에 능동적으로 대처하고 안정적 전력공급을 위해 2011년 제주 추가 직류연계선과 2013년 LNG 발전소 건설을 제3차 전력수급기본계획에 반영 추진중이다. 이 논문은 제주 추가 직류연계선 및 LNG 발전소 건설 타당성, 사업여건의 변동에 따라 제주도의 전력공급신뢰도와 발전원 MIX 전망을 검토하였다.

  • PDF

Summary of Static Reactive Power Compensator and Influence analysis of Power System Stability (무효전력보상장치 설비 개요 및 전력계통 안정화 영향분석)

  • Kim, Sung-Arm;Han, Byung-jun;Jang, Young-Hoon;Choi, Jin-San
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.343-344
    • /
    • 2015
  • 전력산업은 친환경 신재생 에너지 자원의 증대, 국가간 에너지 교류 등 고성능 대용량 전력전자 응용분야 기기의 필요성이 지속적으로 확대되고 있다. 신규 AC 송전선로 건설이 민원 등의 사유로 건설에 장시간 소요되고, 건설단가의 지속적 증가 및 전력전자 설비의 가격하락(HVDC, FACTS 등 특수설비의 국산화 추진) 등으로 AC 송전선로 신규건설 보다는 송전선로 조류제어로 전력계통 유연성 향상이 필요하게 되었으며, 향후 융통전력의 한계, 전력수요 포화 및 Smart Grid 시대를 대비하여 기존 송전선로의 이용을 극대화하는 방향으로 계통계획의 방향 전환이 더욱 급속도로 진행될 전망이다. 본 논문에서는 최첨단 무효전력보상장치 소개와 계통안정화를 위한 전력계통 영향분석을 통해 직 병렬 FACTS의 필요성을 소개하고자 한다.

  • PDF

Study of Self-excited Resonant DC Circuit Breaker in Future DC Grid (향후 DC 전력 계통에서의 자려 공진 DC 차단기에 관한 연구)

  • Guo, Qinglei;Yoon, Minhan;Jang, Gilsoo
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.396-397
    • /
    • 2015
  • With the increasing utilization of high-voltage, direct current (HVDC) transmissions in modern power systems, the DC grid is becoming a hot topic in academic and practical systems. In the DC grid, one of the urgent problems is the fast clearance of the DC fault in the DC network. One preferred method is to isolate the faulty point from the DC network in a short time. The DC circuit breaker is to interrupt the overcurrent after DC faults occur. In this paper, a self-excited resonant DC circuit breaker is an easy and cheap equipment to interrupt the DC fault current. The Mayr's arc model is utilized to simulate the self-excited DC circuit breaker in a DC test system in PSCAD/EMTDC.

  • PDF

Study on comparisons between PSS/E and Matlab Simulink/SimPower Result on network system data (PSS/E - Matlab Simulink/SimPower 간 순시치 시뮬레이션 비교에 관한 연구)

  • Yoo, Yeuntae;Kim, Kisuk;Lee, Changun;Jang, Gilsoo
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.249-250
    • /
    • 2015
  • Technological advance of power elcetronic devices using semiconductor switches in last several decades, invoke the increase of switching devices' penetration in the system like STATCOM or HVDC and also, increase the difficulty to adjust switching characteristics in the virtual simulating configuration, which are not capable of reflect the detailed phenomena. To investigate harmful effect of switching devices into the grid, detailed modeling of power electronic devices are necessary, and the first step for entire grid modelling is simulate power system in time domain model. In this paper, simple two bus system with synchronous generator and infinite bus on the other side has been compromised in two simulation environment, using PSS/E and Matlab/Simulink. Comparing the result of two simulation result will give answers to the fundamental difference between two type of simulation environment.

  • PDF

Characteristic Analysis of Reactive-Power Compensator using Resonant Current-Source Inverter by simplification model (축소모형에 의한 공진형 전류원 인버터식 무효전력보상기의 특성 분석)

  • 한병문;백승택;박덕희;소용철
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.269-274
    • /
    • 1998
  • This paper describes a scaled model for PWM thyristor current-source inverter with a commutation circuit. The system consists of a 6-pulse thyristor bridge and an LC resonant circuit with thyristor switches, which offers thyristors to have turn-off capability for PWM operation with minimal switching losses. The proposed system can be used as a reactive power compensator with PWM operation for the utilitity application. There would be two advantages in the proposed system over the existing voltage source inverter. One is the low system cost due to using the conventional thyristors. Another is easy expansion of system operation voltage because th series operation of thyristor devices is already proven in HVDC system.

  • PDF

STUDY OF VOLTAGE AND HARMONIC STABILITY OF CAPACITOR COMMUTATED CONVERTERS APPLIED TO HVDC/BTB

  • Konishi, Hiroo;Yamada, Tatsuo;Sanpei, Masatoshi;Sano, Takayoshi
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.898-902
    • /
    • 1998
  • Voltage and harmonic stability characteristics of capacitor commutated converters applied to a BTB (back to back) system (CCC-BTB) are analyzed and compared to characteristics of a BTB system composed of conventional line commutated converters (LCC-BTB). About 1.6 times larger safe operating regions can be obtained for the CCC-BTB system compared to the latter. The CCC-BTB system results in no harmonic instability problem as it has no shunt reactive compensators in the station and the adjoining AC system generates no low anti-res onance points.

  • PDF

A New Scheme for Nearest Level Control with Average Switching Frequency Reduction for Modular Multilevel Converters

  • Park, Yong-Hee;Kim, Do-Hyun;Kim, Jae-Hyuk;Han, Byung-Moon
    • Journal of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.522-531
    • /
    • 2016
  • This paper proposes a new NLC (Nearest Level Control) scheme for MMCs (Modular Multilevel Converters), which offers voltage ripple reductions in the DC capacitor of the SM (Sub-Module), the output voltage harmonics, and the switching losses. The feasibility of the proposed NLC was verified through computer simulations. Based on these simulation results, a hardware prototype of a 10kVA, DC-1000V MMC was manufactured in the lab. Experiments were conducted to verify the feasibility of the proposed NLC in an actual hardware environment. The experimental results were consistent with the results obtained from the computer simulations.