• Title/Summary/Keyword: Humidity measurement

Search Result 471, Processing Time 0.055 seconds

A Study on Seasonal Variation of Water Content under Highway Asphalt Pavements Using Neutron Moisture Meter (중성자 수분측정기를 이용한 고속도로 포장의 계절별 함수량 변화 측정에 관한 연구)

  • Song Kwan-Cheol;Lee Sang-Mo;Yoo Sun-Ho;Ryu Kwan-Sik;Park Moo-Eon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.2 no.4
    • /
    • pp.156-166
    • /
    • 2000
  • This study was carried out to provide the information on seasonal variations of water content under highway asphalt pavements which influence on the dynamic behaviour and durability of pavements, and to assess the correlation between water content and soil or meteorological factors. Total eight sites for water content measurement which included fives sites in Kyungbu, two sites in Honam, and one site in Youngdong Highway were selected considering the variations in geology, topology and meteorology factors over all the country. Water contents under asphalt pavements were measured up to 170 cm depth every two week for total 13 months of August 1992 through September 1993 using neutron moisture meter(CPN-503DR). The range of water content ($\theta$$_{w}$) at the upper soils of above 50 cm depth was 7~12% and was not quite different regardless of sites, except for Iseo site. However, soil water contents below 60 or 70 cm depth were significantly different between the measurement sites, that is, the lowest water content was 5% at Kyungsan site and the highest water content was 20% at Iseo site. For all the sites, seasonal variations in water content during the experimental period were little, their range was within only 1 to 4%. Seasonal variations of water content in original or cutting area, which were 4% more or less, were slightly larger than in bedding areas, which were below 2%. Water contents under asphalt pavements had statistically significant positive correlations with silt and clay content in soil, but there were little correlations between water content and meteorological factors such as precipitation, relative humidity, mean air temperature, and wind velocity.

  • PDF

Evaluation of Pedestrian Space Ion Index by Land Use Type in Heat wave - Focused on ChungJu - (폭염시 토지이용유형별 보행공간 이온지수 평가 - 충주시를 대상으로 -)

  • Yoon, Yong Han;Yoon, Ji Hun;Kim, Jeong Ho
    • Korean Journal of Environment and Ecology
    • /
    • v.33 no.3
    • /
    • pp.354-365
    • /
    • 2019
  • This study measured and analyzed the weather characteristics and the air-ion characteristics of walking space by land use type in Chungju, Chungcheongbuk Province during the heat wave. We used the land registration map to classify the type of land use in walking areas in the studied into the production and green area, the residential area, and the commercial area. We then selected 44 measurement points in about 4.1 km. They included 12 walking space points in the green area, 14 in the residential area, and 18 in the commercial area. Moreover, we calculated the ion index by analyzing the impact of weather factors such as temperature, relative humidity, solar radiation, and net radiation in the walking space on the anion generation and cation generation by land use type during the heat wave. Comparison of air ion characteristics in walking space by type of land use during the heat wave showed that the average cation generation was in the order of commercial area ($700.73cations/cm^3$) > residential area ($600.76cations/cm^3$) > green area ($589.73cations/cm^3$). The average anion generation was in the order of green area ($663.95anions/cm^3$) > residential area ($628.48anions/cm^3$) > commercial area ($527.48anions/cm^3$). The average ion index was in the order of green area (1.13) > residential area (1.04) > commercial area (0.75). This study checked the weather characteristics, cation generation, and anion generation in walking space according to the land use type during the heat wave and checked the difference of ion indexes in the walking space according to the land use type. However, there were limitations in the lack of accurate comparison according to the land use due to the moving measurement and the insufficient quantitative comparison according to the change of road width. Therefore, we recommend further studies that consider the road characteristics.

The Effects of Pergola Wisteria floribunda's LAI on Thermal Environment (그늘시렁 Wisteria floribunda의 엽면적지수가 온열환경에 미치는 영향)

  • Ryu, Nam-Hyong;Lee, Chun-Seok
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.45 no.6
    • /
    • pp.115-125
    • /
    • 2017
  • This study was to investigate the user's thermal environments under the pergola($L\;7,200{\times}W\;4,200{\times}H\;2,700mn$) covered with Wisteria floribunda(Willd.) DC. according to the variation of leaf area index(LAI). We carried out detailed measurements with two human-biometeorological stations on a popular square Jinju, Korea($N35^{\circ}10^{\prime}59.8^{{\prime}{\prime}}$, $E\;128^{\circ}05^{\prime}32.0^{{\prime}{\prime}}$, elevation: 38m). One of the stations stood under a pergola, while the other in the sun. The measurement spots were instrumented with microclimate monitoring stations to continuously measure air temperature and relative humidity, wind speed, shortwave and longwave radiation from the six cardinal directions at the height of 0.6m so as to calculate the Universal Thermal Climate Index(UTCI) from $9^{th}$ April to $27^{th}$ September 2017. The LAI was measured using the LAI-2200C Plant Canopy Analyzer. The analysis results of 18 day's 1 minute term human-biometeorological data absorbed by a man in sitting position from 10am to 4pm showed the following. During the whole observation period, daily average air temperatures under the pergola were respectively $0.7{\sim}2.3^{\circ}C$ lower compared with those in the sun, daily average wind speed and relative humidity under the pergola were respectively 0.17~0.38m/s and 0.4~3.1% higher compared with those in the sun. There was significant relationship in LAI, Julian day number and were expressed in the equation $y=-0.0004x^2+0.1719x-11.765(R^2=0.9897)$. The average $T_{mrt}$ under the pergola were $11.9{\sim}25.4^{\circ}C$ lower and maximum ${\Delta}T_{mrt}$ under the pergola were $24.1{\sim}30.2^{\circ}C$ when compared with those in the sun. There was significant relationship in LAI, reduction ratio(%) of daily average $T_{mrt}$ compared with those in the sun and was expressed in the equation $y=0.0678{\ln}(x)+0.3036(R^2=0.9454)$. The average UTCI under the pergola were $4.1{\sim}8.3^{\circ}C$ lower and maximum ${\Delta}UTCI$ under the pergola were $7.8{\sim}10.2^{\circ}C$ when compared with those in the sun. There was significant relationship in LAI, reduction ratio(%) of daily average UTCI compared with those in the sun and were expressed in the equation $y=0.0322{\ln}(x)+0.1538(R^2=0.8946)$. The shading by the pergola covered with vines was very effective for reducing daytime UTCI absorbed by a man in sitting position at summer largely through a reduction in mean radiant temperature from sun protection, lowering thermal stress from very strong(UTCI >$38^{\circ}C$) and strong(UTCI >$32^{\circ}C$) down to strong(UTCI >$32^{\circ}C$) and moderate(UTCI >$26^{\circ}C$). Therefore the pergola covered with vines used for shading outdoor spaces is essential to mitigate heat stress and can create better human thermal comfort especially in cities during summer. But the thermal environments under the pergola covered with vines during the heat wave supposed to user "very strong heat stress(UTCI>$38^{\circ}C$)". Therefore users must restrain themselves from outdoor activities during the heat waves.

EFFECT OF OXYGEN TENSION ON THE ACTIVITY AND FUNCTION OF THE CELLS DERIVED FROM HUMAN PERIODONTAL LIGAMENT (산소 장력이 치주인대에서 유래한 세포의 활성과 기능에 미치는 영향)

  • Sa, Muyng-Hee;Yang, Won-Sik
    • The korean journal of orthodontics
    • /
    • v.27 no.3 s.62
    • /
    • pp.503-513
    • /
    • 1997
  • This study was undertaken to investigate the effect of oxygen tension on the activity and function of the cells derived from human periodontal ligament by measuring cell activity, total protein synthesis, collagen synthesis, $IL-1{\beta},\;IL-6,\;TNF-{\alpha}$ Human periodontal ligament fibroblasts were collected from premolars extracted for orthodontic treatment and incubated in the environment of $37^{\circ}C,\;5\%\;CO_2,\100\%$ humidity. After the fifth to sixth passage they were used for the experiment. Gaspack system to which $0.2{\mu}m$ Millipore filter was attached was connected to mixed-gas tanks. The mixed gases were composed of $10\%\;O_2,\;5\%\;CO_2,\;85\%\;N_2$ in hyoxic group or $90\%\;O_2,\;5\%\;CO_2,\;5\%\;N_2$ in hyperoxic group and $5\%\;CO_2,\;95\%$ air for control. After incubation in $37^{\circ}C$ for 2, 4, 6 days, cell activity was determined by tetrazolium(MTT) assay and total protein synthesis was assayed using sulforhodamine B(SRB). And measurement of 4-hydroxyproline was performed to assess collagen synthesis md $IL-1{\beta},\;IL-6,\;and\;TNF-{\alpha}$ were measured by enzymeimmunoassay. The results were as follows. 1. The cell activity and total protein synthesis in hypoxic group were a little higher than or almost the same with those in control group. 2. In hyperoxic group, the cell activity was lower than that in control group and total protein synthesis was decreased. 3. Collagen synthesis was significantly decreased initially in both hypoxic and hyperoxic group and increased nearly to the level of control group as the duration of cell incubation was longer 4. As a result of enzymeimmunoassay, the amount of cytokines was $IL-6,\;TNF-{\alpha}\;and\;IL-1{\beta}$ in order. 5. $IL-6,\;TNF-{\alpha}\;and\;IL-1{\beta}$ were increased more rapidly in both hypoxic and hyperoxic group than in control group as the duration of cell incubation was longer. 6. There were more $IL-6\;and\;TNF-{\alpha}$ in hyperoxic group than in control group after 6 days, and there were more $IL-6\;and\;TNF-{\alpha}$ after 6 days than after 2 or 4 days in hyperoxic group. These results suggested that oxygen tension might modulate the production of extracellular matrix and cytokines in the cells derived from human periodontal ligament.

  • PDF

Monitoring soybean growth using L, C, and X-bands automatic radar scatterometer measurement system (L, C, X-밴드 레이더 산란계 자동측정시스템을 이용한 콩 생육 모니터링)

  • Kim, Yi-Hyun;Hong, Suk-Young;Lee, Hoon-Yol;Lee, Jae-Eun
    • Korean Journal of Remote Sensing
    • /
    • v.27 no.2
    • /
    • pp.191-201
    • /
    • 2011
  • Soybean has widely grown for its edible bean which has numerous uses. Microwave remote sensing has a great potential over the conventional remote sensing with the visible and infrared spectra due to its all-weather day-and-night imaging capabilities. In this investigation, a ground-based polarimetric scatterometer operating at multiple frequencies was used to continuously monitor the crop conditions of a soybean field. Polarimetric backscatter data at L, C, and X-bands were acquired every 10 minutes on the microwave observations at various soybean stages. The polarimetric scatterometer consists of a vector network analyzer, a microwave switch, radio frequency cables, power unit and a personal computer. The polarimetric scatterometer components were installed inside an air-conditioned shelter to maintain constant temperature and humidity during the data acquisition period. The backscattering coefficients were calculated from the measured data at incidence angle $40^{\circ}$ and full polarization (HH, VV, HV, VH) by applying the radar equation. The soybean growth data such as leaf area index (LAI), plant height, fresh and dry weight, vegetation water content and pod weight were measured periodically throughout the growth season. We measured the temporal variations of backscattering coefficients of the soybean crop at L, C, and X-bands during a soybean growth period. In the three bands, VV-polarized backscattering coefficients were higher than HH-polarized backscattering coefficients until mid-June, and thereafter HH-polarized backscattering coefficients were higher than VV-, HV-polarized back scattering coefficients. However, the cross-over stage (HH > VV) was different for each frequency: DOY 200 for L-band and DOY 210 for both C and X-bands. The temporal trend of the backscattering coefficients for all bands agreed with the soybean growth data such as LAI, dry weight and plant height; i.e., increased until about DOY 271 and decreased afterward. We plotted the relationship between the backscattering coefficients with three bands and soybean growth parameters. The growth parameters were highly correlated with HH-polarization at L-band (over r=0.92).

Variation and Distribution of Anions and Cations in the Aerosols of Gyorae Forests in Jeju Island (제주도 교래휴양림 지역의 대기질의 음이온 및 양이온의 분포와 변이성)

  • Sin, Bangsik;Im, Dongho;Lee, Keun Kwang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.7
    • /
    • pp.384-395
    • /
    • 2018
  • This study was conducted to investigate the distribution and variation of the anion and cation number of aerosols in the A and B regions of Gyorae forests. Ions were measured using an ion number meter between 28 June and 13 July 2017. The total average number of anions and cations were $735ions/cm^3$ and $459.27ions/cm^3$, respectively, which were measured at five sites in A area at average temperature of $27.81^{\circ}C$, wind speed of 0.28 m/sec, and altitude of 455.7 m. The average number of anions and cations were $780ions/cm^3$ and $379.55ions/cm^3$, respectively, which were measured at all four sites in the B region at average temperature of $27.6^{\circ}C$, humidity of 80%, wind speed of 0.1 m/sec and altitude of 477 m. The number of anions and cations in the A and B regions was $757.5ions/cm^3$ and $419.41ions/cm^3$, respectively. The number of ions was highly variable for each measurement over time. The number of anions remained $275.73ions/cm^3$ higher than that of cations. The variance of the measured values of anions and cations between and within sites A and B was significant (p<.001) and there was a significant positive correlation between regional mean values of anions and cations. In conclusion, the temporal distribution and variation of the ion content in the Gyorae forests provide basic information regarding aerosol compositions and changes.

Comparison of Radiation Dose in the Measurement of MDCT Radiation Dose according to Correction of Temperatures and Pressure, and Calibration of Ionization Chamber (MDCT 선량측정에서 온도와 압력에 따른 보정과 Ionization Chamber의 Calibration 전후 선량의 비교평가)

  • Lee, Chang-Lae;Kim, Hee-Joung;Jeon, Seong-Su;Cho, Hyo-Min;Nam, So-Ra;Jung, Ji-Young;Lee, Young-Jin;Lee, Seung-Jae;Dong, Kyung-Rae
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.49-55
    • /
    • 2008
  • This study aims to conduct the comparative analysis of the radiation dose according to before and after the calibration of the ionization chamber used for measuring radiation dose in the MDCT, as well as of $CTDI_w$ according to temperature and pressure correction factors in the CT room. A comparative analysis was conducted based on the measured MDCT (GE light speed plus 4 slice, USA) data using head and body CT dosimetric phantom, and Model 2026C electrometer (RADICAL 2026C, USA) calibrated on March 21, 2007. As a result, the $CTDI_w$ value which reflected calibration factors, as well as correction factors of temperature and pressure, was found to be the range of $0.479{\sim}3.162mGy$ in effective radiation dose than the uncorrected values. Also, under the routine abdomen routine CT image acquisition conditions used in reference hospitals, patient effective dose was measured to indicate the difference of the maximum of 0.7 mSv between before and after the application of such factors. These results imply that the calibration of the ion chamber, and the correction of temperature and pressure of the CT room are crucial in measuring and calculating patient effective dose. Thus, to measure patient radiation dose accurately, the detailed information should be made available regarding not only the temperature and pressure of the CT room, but also the humidity and recombination factor, characteristics of X-ray beam quality, exposure conditions, scan region, and so forth.

  • PDF

Measurement of Operator Exposure During Treatment of Fungicide Difenoconazole on Grape Orchard (포도 과수원에서 살균제 Difenoconazole의 농작업자 노출량 측정)

  • Cho, ll Kyu;Park, Joon Seong;Park, So Hyun;Kim, Su Jin;Kim, Back Jong;Na, Tae Wong;Nam, Hyo Song;Park, Kyung Hun;Lee, Jiho;Kim, Jeong-Han
    • Korean Journal of Environmental Agriculture
    • /
    • v.35 no.4
    • /
    • pp.286-293
    • /
    • 2016
  • BACKGROUND: 18% of difenoconazole+iminoctadin triacetate microemulsion (3%+15%) formulation were mixed and sprayed as closely as possible to normal practice on the ten of farms located in the Youngju of South Korea. Patches, cotton gloves, socks, masks and XAD-2 resin were used to measure the potential exposure for applicators wearing standardized whole-body outer and inner dosimeter (WBD). This study has been carried out to determine the dermal and inhalation exposure to difenoconazole during preparation of spray suspension and application with a power sprayer on a grape orchard. METHODS AND RESULTS: A personal air monitor equipped with an air pump IOM sampler and cassette and glass fiber filter were used for inhalation exposure. The field studies were carried out in a grape orchard. The temperature and relative humidity were monitored with a thermometer and a hygrometer. Wind speed was measured using a pocket weather meter. All mean field fortification recoveries were between 97.3% and 119.6% in the level of 100 LOQ (limit of quantification) while the LOQ for difenoconazole was $0.025{\mu}g/mL$ using HPLC-UVD. The arms exposure to difenoconazole for the mixer/loader (0.0794 mg) was higher than other body parts (head, hands, upper body, legs). The exposure to difenoconazole in the legs for applicator (3.78 mg) was highest in the parts of body. The dermal exposure for mixer/loader and applicator were 0.02 and 2.28 mg on a grape orchard, respectively. The inhalation exposure during application was estimated as 0.02 mg. The ratio of inhalation exposure to dermal exposure was equivalent to 0.9% of the dermal exposure. CONCLUSION: The inhalation exposure for applicator indicated $18.8{\times}10^{-3}mg$, which was level of 0.9% of the dermal exposure (2.28 mg). Operator exposure (0.004 mg/kg bw/day) to difenoconazole during treatment for grape is calculated as 2.5% of the established AOEL (0.16 mg/kg bw/day).

Risk Assessment of Operator Exposure During Treatment of Fungicide Dithianon on Apple Orchard (사과 과수원에서 농약살포시 살균제 Dithianon의 농작업자 위해성 평가)

  • Cho, ll Kyu;Kim, Su Jin;Kim, Ji Myung;Oh, Young Goun;Seol, Jae Ung;Lee, Ji Ho;Kim, Jeong Han
    • Korean Journal of Environmental Agriculture
    • /
    • v.37 no.4
    • /
    • pp.302-311
    • /
    • 2018
  • BACKGROUND: Dithianon (75%) formulation were mixed and sprayed as closely as possible by normal practice on the ten farms located in the Mungeong of South Korea. Patches, cotton gloves, socks, masks, and XAD-2 resin were used for measurement of the potential exposure of dithianon on the applicators wearing standardized whole-body outer and inner dosimeter (WBD). This study has been carried out to determine the dermal and inhalation exposure to dithianon during preparation of spray suspension and application with a power sprayer on a apple orchard. METHODS AND RESULTS: A personal air monitor equipped with an air pump, IOM sampler and cassette, and glass fiber filter was used for inhalation exposure. The field studies were carried out in a apple orchard. The temperature and relative humidity were monitored with a thermometer and a hygrometer. Wind speed was measured using a pocket weather meter. All mean field fortification recoveries were between 85.1% and 99.1% in the level of 100 LOQ (limit of quantification), while the LOQ for dithianon was $0.05{\mu}g/mL$ using HPLC-DAD. The exposure to dithianon on arms of the mixer/loader (0.0794 mg) was higher than other body parts (head, hands, upper body, or legs). The exposure to dithianon on the applicator's legs (3.78 mg) was highest in the body parts. The dermal exposures for mixer/loader and applicator were 10 and 8.10 mg, respectively, from a grape orchard. The inhalation exposure during application was estimated as 0.151 mg, and the ratio of inhalation exposure was 11.2% of the dermal exposure (inner clothes). CONCLUSION: The dermal and inhalation exposure on the applicator appeared to be 4.203 mg - 25.064 mg and $0.529{\mu}g-116.241{\mu}g$, respectively. The total exposures on the agricultural applicators were at the level of 2.596 mg - 25.069 mg to dithianon during treatment for apple orchard. The TER showed 3.421 (>1) when AOEL of dithianon was used as a reference dose for the purpose of risk assessment of the mixing/loading and application.

The study of thermal change by chemoport in radiofrequency hyperthermia (고주파 온열치료시 케모포트의 열적 변화 연구)

  • Lee, seung hoon;Lee, sun young;Gim, yang soo;Kwak, Keun tak;Yang, myung sik;Cha, seok yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.97-106
    • /
    • 2015
  • Purpose : This study evaluate the thermal changes caused by use of the chemoport for drug administration and blood sampling during radiofrequency hyperthermia. Materials and Methods : 20cm size of the electrode radio frequency hyperthermia (EHY-2000, Oncotherm KFT, Hungary) was used. The materials of the chemoport in our hospital from currently being used therapy are plastics, metal-containing epoxy and titanium that were made of the diameter 20 cm, height 20 cm insertion of the self-made cylindrical Agar phantom to measure the temperature. Thermoscope(TM-100, Oncotherm Kft, Hungary) and Sim4Life (Ver2.0, Zurich, Switzerland) was compared to the actual measured temperature. Each of the electrode measurement position is the central axis and the central axis side 1.5 cm, 0 cm(surface), 0.5 cm, 1.8 cm, 2.8 cm in depth was respectively measured. The measured temperature is $24.5{\sim}25.5^{\circ}C$, humidity is 30% ~ 32%. In five-minute intervals to measure the output power of 100W, 60 min. Results : In the electrode central axis 2.8 cm depth, the maximum temperature of the case with the unused of the chemoport, plastic, epoxy and titanium were respectively $39.51^{\circ}C$, $39.11^{\circ}C$, $38.81^{\circ}C$, $40.64^{\circ}C$, simulated experimental data were $42.20^{\circ}C$, $41.50^{\circ}C$, $40.70^{\circ}C$, $42.50^{\circ}C$. And in the central axis electrode side 1.5 cm depth 2.8 cm, mesured data were $39.37^{\circ}C$, $39.32^{\circ}C$, $39.20^{\circ}C$, $39.46^{\circ}C$, the simulated experimental data were $42.00^{\circ}C$, $41.80^{\circ}C$, $41.20^{\circ}C$, $42.30^{\circ}C$. Conclusion : The thermal variations were caused by radiofrequency electromagnetic field surrounding the chemoport showed lower than in the case of unused in non-conductive plastic material and epoxy material, the titanum chemoport that made of conductor materials showed a slight differences. This is due to the metal contents in the chemoport and the geometry of the chemoport. And because it uses a low radio frequency bandwidth of the used equipment. That is, although use of the chemoport in this study do not significantly affect the surrounding tissue. That is, because the thermal change is insignificant, it is suggested that the hazard of the chemoport used in this study doesn't need to be considered.

  • PDF