• Title/Summary/Keyword: Humidity effects

Search Result 958, Processing Time 0.033 seconds

Effect of Combined Supplementation Catechin and Vitamin C on Growth Performance, Meat Quality, Blood Composition and Stress Responses of Broilers under High Temperature (고온 환경에서 카테킨 및 비타민 C 첨가가 육계의 생산성, 계육품질, 혈액성분 및 스트레스 지표에 미치는 영향)

  • Jiseon Son;Woo-Do Lee;Hee-jin Kim;Hyunsoo Kim;Eui-Chul Hong;Iksoo Jeon;Hwan-Ku Kang
    • Korean Journal of Poultry Science
    • /
    • v.50 no.1
    • /
    • pp.1-13
    • /
    • 2023
  • The study was carried out to investigate the effects of dietary combined supplementation of antioxidants as catechin and vitamin C on growth performance, meat quality, blood profiles and stress responses of broilers exposed to high temperature. For this experiment, a total of 360 21-day-old male Ross 308 broilers were used. Treatments were assigned with 6 replicates per treatment and 10 birds per replicate in a 2 × 3 factorial design with vitamin C (0, 250 mg/kg) and catechin (0, 600, 1,200 mg/kg). The heat stress environment was maintained at temperature 32±1℃ and relative humidity 60±5% for 24 hours until the end of the experiment. The supplemented antioxidants had no significant difference in weight gain, feed intake and feed conversion ratio (P>0.05). The content of total cholesterol in blood had no interaction, but decrease (P<0.01) in the supplemented catechin group. Also, the supplementation with catechin showed increase in the SOD activity of blood, and lower corticosterone and IgM levels of broilers. The contents of HSP70 and MDA in liver decrease (P<0.05) with the supplementation of antioxidants, and HSP70 showed an interaction between groups. DPPH radical scavenging ability in breast meat increased (P<0.01) in catechin, but meat quality did not show difference according to treatments. Respiratory rate decreased (P<0.05) in catechin, but no interaction with vitamin C. In conclusion, the combination of vitamin C and catechin can alleviate stress under high temperature, such as HSP70 and MDA, but further study on the optimal supplemental level is needed.

A Study on the Characteristic of Habitat and Mating Calls in Korean Auritibicen intermedius (Hemiptera: Cicadidae) Using Bioacoustic Detection Technique (생물음향탐지기법을 활용한 한국 참깽깽매미 서식 및 번식울음 특성 연구)

  • Yoon-Jae Kim;Kyong-Seok Ki
    • Korean Journal of Environment and Ecology
    • /
    • v.36 no.6
    • /
    • pp.592-602
    • /
    • 2022
  • This study aimed to check habitat distribution and analyze influencing factors by analyzing the mating calls of Auritibicen intermedius inhabiting limited locations in South Korea by applying bioacoustic detection techniques. The study sites were 20 protection areas nationwide. The mating call analysis period was 4 years from 2017 to 2021, excluding 2020. The bioacoustic recording system installed at each study site collected recordings of mating calls every day for 1 minute per hour. Climate data received from the Meteorological Agency, such as temperature, humidity, rainfall, cloudiness, and sunshine, were analyzed. The results of this study identified A. intermedius habitat only in four national parks in the highlands of Gangwon Province (Mt. Seorak, Mt. Odae, Mt. Chiak, and Mt. Taebak) out of 20 study sites. During the four years of study, the mating call period of A. intermedius was between August 5 and September 28, and the duration of the mating call was 31 to 52 days. The temperature analysis during the appearance period of A. intermedius showed that A. intermedius mainly produced mating calls at temperatures between 13.1℃ and 35.3℃, and the average temperature during the circadian cycle of mating calls (09:00 to 16:00) was 24.4 to 24.9℃. The analysis of the circadian cycle of mating calls at four study sites where A. intermedius appeared in 2019 showed that A. intermedius produced mating calls from 06:00 to 16:00 and that they peaked around 11:00 to 12:00. During the appearance period of A. intermedius, four species appeared in common: Hyalessa maculaticollis, Meimuna opalifera, Graptopsaltria nigrofuscata, and Suisha coreana. A logistic regression analysis confirmed that sunlight was the environmental factor affecting the mating call of A. intermedius. Regarding interspecific influence, it was confirmed that A. intermedius exchanged interspecific influence with 4 other common species (H. maculaticollis, M. opalifera, G. nigrofuscata, and S. coreana). The above results confirmed that A. intermedius habitats were limited in the highlands of Gangwon Province highlands in Korea and produced mating calls at a lower temperature compared to other species. These results can be used as basic data for future research on A. intermedius in Korea.

Effects of Impact of Climate Change on Livestock Productivity - For bullocks, dairy, pigs, laying hens, and broilers - (기후변화가 축산 생산성에 미치는 영향 -거세우, 낙농, 양돈, 산란계, 육계를 대상으로-)

  • Lee, H.K.;Park, H.M.;Shin, Y.K.
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.20 no.1
    • /
    • pp.107-123
    • /
    • 2018
  • The global impact of climate change on agriculture is now increasing. The purpose of this study was to investigate the effect of climate change on livestock productivity. The variables that have the greatest influence on climate change factors were examined through previous studies and expert surveys. We also used the actual productivity data of livestock farmers to investigate the relationship with climate change. In order to evaluate the climate for changes in livestock productivity, national representative data (such as bullocks, dairy, pigs, laying hens, and broilers) were surveyed in Korea. Also, to select and classify evaluation indexes, we selected climate change factor variables as prior studies and studied the weighting factor of climate variable factors. In this study, the researchers of industry, academia, and farmers in the livestock sector conducted questionnaires on the indicators of vulnerability to climate change using experts, and then weighed the selected indicators using the hierarchical analysis process (AHP). In order to verify the validity of the evaluation index, was examined using domestic climate data (temperature, precipitation, humidity, etc.). Correlation and regression analysis were performed. The empirical relationship between climate change and livestock productivity was examined through this study. As a result, we used data with high reliability of statistical analysis and found that there are significant variables.

Pergola's Shading Effects on the Thermal Comfort Index in the Summer Middays (여름철 낮 그늘시렁의 차양이 온열쾌적 지표에 미치는 영향)

  • Ryu, Nam-Hyong;Lee, Chun-Seok
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.41 no.6
    • /
    • pp.52-61
    • /
    • 2013
  • This study was conducted to investigate the effects of pergola's shading on the thermal comfort index in the summer. The 3 type of pergolas($4m{\times}4m{\times}h2.7m$) which were screened overhead(I)/overhead west(II)/overhead west north(III) plane with reed blind for summer shading and winter wind break, were constructed on the 4th floor rooftop. Thereafter the meteorological variables(air temperature, humidity, radiation, and wind speed) of pergola I, III and rooftop were measured from 14 to 16 August 2013(1st experiment), those of pergola I, II and rooftop were measured from 26 to 28 August 2013(2nd experiment). The effects of pergola's shading on the radiation environment and mean radiant temperature($T_{mrt}$), standard effective temperature($SET^*$) were as follows. The maximum 1 h mean values of differences ${\Delta}$ of the sums of shortwave radiant flux densities absorbed by the human body (${\Delta}K_{abs,max}$) between pergola I, III and nearby sunny rooftop were $-119W/m^2$, $-158W/m^2$, those between pergola I, II and rooftop were $-145W/m^2$, $-159W/m^2$. The maximum 1 h mean values of differences ${\Delta}$ of the sums of long wave radiant flux densities absorbed by the human body (${\Delta}L_{abs,max}$) between pergola I, III and nearby sunny rooftop, were $-15W/m^2$, $-17W/m^2$, those between pergola I, II and nearby rooftop, were $-8W/m^2$, $-7W/m^2$. The response of the direction dependent long wave radiant flux densities $L_1$ on the pergola's shading turned out to be distinctly weaker as compared to shortwave radiant flux densities $K_1$. The pergola's shading leads to a lowering of $T_{mrt}$ and $SET^*$. The peak values of $T_{mrt}$ absorbed by the human body were decreased $16^{\circ}C$ and $21.4^{\circ}C$ under pergola I and III as compared to that of nearby rooftop in the 1st experiment. Those were decreased $18.8^{\circ}C$ and $20.8^{\circ}C$ under pergola I and II as compared to that of nearby rooftop in the 2nd experiment. The peak values of $SET^*$ absorbed by the human body were decreased $2.9^{\circ}C$ and $2.6^{\circ}C$ under pergola I and III as compared to that of nearby rooftop in the 1st experiment. Those were decreased $3.5^{\circ}C$ and $2.6^{\circ}C$ under pergola I and II as compared to that of nearby rooftop in the 2nd experiment. The relative $SET^*$ decrease in pergola II, III compared to nearby sunny rooftop $SET^*$ were lower than that in pergola I, revealing the influence of the wind speed. Therefore it is essential to design pergola to maximize wind speed and minimize solar radiation to achieve comfort in the hot summer. The $SET^*$ under pergola I, III were exceeded $28.7^{\circ}C$ and $30.4^{\circ}C$ which were the upper limit of thermal comfort and tolerable zone during all most daytimes in the 1st experiment(maximum air temperature $37.5^{\circ}C$). The $SET^*$ under pergola I was exceeded $28.7^{\circ}C$ which was the upper limit of thermal comfort zone at 13h, that under pergola II was exceeded $28.7^{\circ}C$ from 8h to 14h, meanwhile the $SET^*$ under pergola I, II were within thermal tolerable zone during most daytimes in the 2nd experiment(maximum air temperature $34.4^{\circ}C$). Therefore to ensure the thermal comfort of pergola for summer hottest days, pergola should be shaded with not only reed blind but also climbing and shade plants. $T_{mrt}$ and $SET^*$ were suitable index for the evaluation of pergola's shading effects and outdoors.

Studies on the Mechanical Properties of Weathered Granitic Soil -On the Elements of Shear Strength and Hardness- (화강암질풍화토(花崗岩質風化土)의 역학적(力學的) 성질(性質)에 관(關)한 연구(硏究) -전단강도(剪斷强度)의 영향요소(影響要素)와 견밀도(堅密度)에 대(對)하여-)

  • Cho, Hi Doo
    • Journal of Korean Society of Forest Science
    • /
    • v.66 no.1
    • /
    • pp.16-36
    • /
    • 1984
  • It is very important in forestry to study the shear strength of weathered granitic soil, because the soil covers 66% of our country, and because the majority of land slides have been occured in the soil. In general, the causes of land slide can be classified both the external and internal factors. The external factors are known as vegetations, geography and climate, but internal factors are known as engineering properties originated from parent rocks and weathering. Soil engineering properties are controlled by the skeleton structure, texture, consistency, cohesion, permeability, water content, mineral components, porosity and density etc. of soils. And the effects of these internal factors on sliding down summarize as resistance, shear strength, against silding of soil mass. Shear strength basically depends upon effective stress, kinds of soils, density (void ratio), water content, the structure and arrangement of soil particles, among the properties. But these elements of shear strength work not all alone, but together. The purpose of this thesis is to clarify the characteristics of shear strength and the related elements, such as water content ($w_o$), void ratio($e_o$), dry density (${\gamma}_d$) and specific gravity ($G_s$), and the interrelationship among related elements in order to decide the dominant element chiefly influencing on shear strength in natural/undisturbed state of weathered granitic soil, in addition to the characteristics of soil hardness of weathered granitic soil and root distribution of Pinus rigida Mill and Pinus rigida ${\times}$ taeda planted in erosion-controlled lands. For the characteristics of shear strength of weathered granitic soil and the related elements of shear strength, three sites were selected from Kwangju district. The outlines of sampling sites in the district were: average specific gravity, 2.63 ~ 2.79; average natural water content, 24.3 ~ 28.3%; average dry density, $1.31{\sim}1.43g/cm^3$, average void ratio, 0.93 ~ 1.001 ; cohesion, $ 0.2{\sim}0.75kg/cm^2$ ; angle of internal friction, $29^{\circ}{\sim}45^{\circ}$ ; soil texture, SL. The shear strength of the soil in different sites was measured by a direct shear apparatus (type B; shear box size, $62.5{\times}20mm$; ${\sigma}$, $1.434kg/cm^2$; speed, 1/100mm/min.). For the related element analyses, water content was moderated through a series of drainage experiments with 4 levels of drainage period, specific gravity was measured by KS F 308, analysis of particle size distribution, by KS F 2302 and soil samples were dried at $110{\pm}5^{\circ}C$ for more than 12 hours in dry oven. Soil hardness represents physical properties, such as particle size distribution, porosity, bulk density and water content of soil, and test of the hardness by soil hardness tester is the simplest approach and totally indicative method to grasp the mechanical properties of soil. It is important to understand the mechanical properties of soil as well as the chemical in order to realize the fundamental phenomena in the growth and the distribution of tree roots. The writer intended to study the correlation between the soil hardness and the distribution of tree roots of Pinus rigida Mill. planted in 1966 and Pinus rigida ${\times}$ taeda in 199 to 1960 in the denuded forest lands with and after several erosion control works. The soil texture of the sites investigated was SL originated from weathered granitic soil. The former is situated at Py$\ddot{o}$ngchangri, Ky$\ddot{o}$m-my$\ddot{o}$n, Kogs$\ddot{o}$ng-gun, Ch$\ddot{o}$llanam-do (3.63 ha; slope, $17^{\circ}{\sim}41^{\circ}$ soil depth, thin or medium; humidity, dry or optimum; height, 5.66/3.73 ~ 7.63 m; D.B.H., 9.7/8.00 ~ 12.00 cm) and the Latter at changun-long Kwangju-shi (3.50 ha; slope, $12^{\circ}{\sim}23^{\circ}$; soil depth, thin; humidity, dry; height, 10.47/7.3 ~ 12.79 m; D.B.H., 16.94/14.3 ~ 19.4 cm).The sampling areas were 24quadrats ($10m{\times}10m$) in the former area and 12 in the latter expanding from summit to foot. Each sampling trees for hardness test and investigation of root distribution were selected by purposive selection and soil profiles of these trees were made at the downward distance of 50 cm from the trees, at each quadrat. Soil layers of the profile were separated by the distance of 10 cm from the surface (layer I, II, ... ...). Soil hardness was measured with Yamanaka soil hardness tester and indicated as indicated soil hardness at the different soil layers. The distribution of tree root number per unit area in different soil depth was investigated, and the relationship between the soil hardness and the number of tree roots was discussed. The results obtained from the experiments are summarized as follows. 1. Analyses of simple relationship between shear strength and elements of shear strength, water content ($w_o$), void ratio ($e_o$), dry density (${\gamma}_d$) and specific gravity ($G_s$). 1) Negative correlation coefficients were recognized between shear strength and water content. and shear strength and void ratio. 2) Positive correlation coefficients were recognized between shear strength and dry density. 3) The correlation coefficients between shear strength and specific gravity were not significant. 2. Analyses of partial and multiple correlation coefficients between shear strength and the related elements: 1) From the analyses of the partial correlation coefficients among water content ($x_1$), void ratio ($x_2$), and dry density ($x_3$), the direct effect of the water content on shear strength was the highest, and effect on shear strength was in order of void ratio and dry density. Similar trend was recognized from the results of multiple correlation coefficient analyses. 2) Multiple linear regression equations derived from two independent variables, water content ($x_1$ and dry density ($x_2$) were found to be ineffective in estimating shear strength ($\hat{Y}$). However, the simple linear regression equations with an independent variable, water content (x) were highly efficient to estimate shear strength ($\hat{Y}$) with relatively high fitness. 3. A relationship between soil hardness and the distribution of root number: 1) The soil hardness increased proportionally to the soil depth. Negative correlation coefficients were recognized between indicated soil hardness and the number of tree roots in both plantations. 2) The majority of tree roots of Pinus rigida Mill and Pinus rigida ${\times}$ taeda planted in erosion-controlled lands distributed at 20 cm deep from the surface. 3) Simple linear regression equations were derived from indicated hardness (x) and the number of tree roots (Y) to estimate root numbers in both plantations.

  • PDF

The Environmental and Ecological Meaning of Bibo Landscape in Otgol Village (옻골마을 비보경관의 환경생태적 의미)

  • Jang, Byoung-Kwan;Whang, Bo-Chul
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.36 no.2
    • /
    • pp.32-41
    • /
    • 2008
  • An empirical study and environmental and ecological analysis were conducted on Otgol Village(a village of the Gyeongju Choi's clan in Daegu) where an enclosed pond and groves are still observed. In particular, the enclosed pond and groves and village water system were investigated from an ecological perspective. The enclosed landscape is described based on feng shui principles and the environmental and ecological significance were examined. In general, the environmental and ecological significance is very broad; however, they were analyzed in terms of the quality of life as an empirical study as follows: First, water quality was measured to investigate the improvement of continuous water system functions. In other words, water quality was measured at East Valley(resting space), West Valley(living space), the enclosed pond where the two valleys merge, and the stream that flows out of the pond. Second, the climate functions of the enclosed groves that border the village were examined. In other words, temperature was measured in two places(200m distance from the center of the groves). Third, whether or not a sound ecosystem can be sustained was investigated. In other words, landscape ecological indicators were chosen and measured. The results are as follows: First, the enclosed pond played the role of purifying water quality. While the East Valley has been popular with men for its rock walls and torrents, the West Valley has been popular with women as a living space(ex: doing the laundry). Therefore, the difference of water quality can be explained. Second, since enclosed groves are in a small village forest, they are very weak in terms of being wind proof and temperature reduction effects. Instead, they play the role of the village boundary. Third, the groves are ecologically sound considering the landscape ecological indicators and are similar to ordinary traditional rural villages. In terms of the connection of the green zone, the village groves are well connected to the village boundary wood. If the village groves are restored, in particular, they would offer a decent habitat for grove creatures. According to this study, the traditional village space was formed upon the influence of Feng Shui theories that are based on environmental and ecological principles that focus on the harmony between humans and nature. From the environmental and ecological perspective, the enclosed pond and groves are important factors in building a sustainable village. The diverse water space would help to improve water quality and increase water volume by promoting the water circulation system. In addition, the village woods would surround the village and decrease the temperature and humidity difference between winter and summer. If the groves are small and badly damaged, however, they are meaningful only in dividing the region. The overall improvement of a forestation system and botanical composition may increase the biological diversity and promote the migration of species. Otgol Village has developed an enclosed landscape to improve the village environment. In other words, a sound and refreshing living environment can be developed when the natural ecological system is well understood and properly preserved. Additionally, this traditional village planning will be the environmental and ecological method. From the perspective of environmental ecology, therefore, a traditional village is recommended.

THE EFFECTS OF VARIOUS TETRACYCLINE HCL CONCENTRATION TREATED ROOW SURFACES ON PROLIFERATION AND SPREADING OF PERIODONTAL LIGAMENT CELLS (다양한 농도의 테트라사이클린로 처리된 치근면이 치주인대세포의 증식과 전개에 미치는 영향)

  • Jung, Oh-Chul;Sun, Jo-Young
    • Journal of Periodontal and Implant Science
    • /
    • v.24 no.3
    • /
    • pp.581-596
    • /
    • 1994
  • This in vitro study was undertaken to obtain optimal tetracycline concentration that aids proliferation and spreading of human periodontal ligament cells, for clinical application in root surfaces of periodontally diseased teeth. Periodontal ligament cells used in this study were obtained from explants of periodontal ligament of 1st premolar teeth which were extracted for the purpose of orthodontic treatment. The cells were cultured in Dulbecco's Modified Eagle Medium(DMEM) supplemented with 100 U/ml penicillin, $100\;{\mu}g/ml$ streptomycin and 10% FBS at $37^{\circ}C$, 100% humidity, 5% $CO_2-95%$ air. Cells were used between the third to 4th passage. After root planing of periodontally extracted teeth, the root slabs were cut with carborundum disk. In the cell proliferation experiment, experimental groups were root planing only group, immersed groups in 25, 50, 75, 100, 150mg/ml aqueous solution of Tetracycline HCl followed by a vigorous rinse in PBS. Human PDL cells at concentration of $1{\times}10^5\;cells/ml$ were seeded in each culture well which contained root slabs and incubated for 6 hours. Then, all of the root slabs were moved into new 24 culture well and incubated 24, 48 and 72 hours. The cell counting was done by inverted phase contrast microscope after trypsinization. The following results were obtained. The cell number was increased in order root planing only group, 25, 150, 50, 75, 100mg/ml of Tetracycline HCl treated group in 24, 48 and 72 hours. The maximal cell number was obtained when the root slabs were immersed in solution with 100mg/ml of Tetracycline HCl. There were statistically significant between the root planing only group and 75, 100 mg/ml of Tetracycline HCl treated group in 24 hours, between the root planing only group and 100mg/ml of Tetracycline HCl treated group in 48 hours, between the root planing only group and 50, 75, 100mg/ml of Tetracycline HCl treated group, between 25 and 100mg/ml of Tetracycline HCl treated group in 72 hours(p<0.05). In the cell spreading experiment, after 30 minutes of incubated, in the root planing only group, the cells were generally round in shape. The cell surface was mostly covered with blebs. The cells started to attach to root surface by cytoplasmic extension in 50, 100mg/ml of Tetracycline HCl treated groups, more numerous cells attached to root surface than root planing only group. Many orifices of dentinal tubule were exposed, cells showed radially spreaded cytoplasm and unspreaded central region of the cell was covered with blebs. After 6 hours of incubation, in the root planing only group, cells showed radially spreaded cytoplasm and were attached flat appearance. In 50, 100mg/ml of Tetracycline HCl treated groups, cellular margin was concaved and cytoplasm showed elongated appearance with polarity. After 24 hours of incubation, in the root planing group, cells showed characteristic polarity. In 50, 100mg/ml of Tetracycline HCl treated groups, cells showed more elongated and spindle - like appearance.

  • PDF

Analysis of Greenhouse Thermal Environment by Model Simulation (시뮬레이션 모형에 의한 온실의 열환경 분석)

  • 서원명;윤용철
    • Journal of Bio-Environment Control
    • /
    • v.5 no.2
    • /
    • pp.215-235
    • /
    • 1996
  • The thermal analysis by mathematical model simulation makes it possible to reasonably predict heating and/or cooling requirements of certain greenhouses located under various geographical and climatic environment. It is another advantages of model simulation technique to be able to make it possible to select appropriate heating system, to set up energy utilization strategy, to schedule seasonal crop pattern, as well as to determine new greenhouse ranges. In this study, the control pattern for greenhouse microclimate is categorized as cooling and heating. Dynamic model was adopted to simulate heating requirements and/or energy conservation effectiveness such as energy saving by night-time thermal curtain, estimation of Heating Degree-Hours(HDH), long time prediction of greenhouse thermal behavior, etc. On the other hand, the cooling effects of ventilation, shading, and pad ||||&|||| fan system were partly analyzed by static model. By the experimental work with small size model greenhouse of 1.2m$\times$2.4m, it was found that cooling the greenhouse by spraying cold water directly on greenhouse cover surface or by recirculating cold water through heat exchangers would be effective in greenhouse summer cooling. The mathematical model developed for greenhouse model simulation is highly applicable because it can reflects various climatic factors like temperature, humidity, beam and diffuse solar radiation, wind velocity, etc. This model was closely verified by various weather data obtained through long period greenhouse experiment. Most of the materials relating with greenhouse heating or cooling components were obtained from model greenhouse simulated mathematically by using typical year(1987) data of Jinju Gyeongnam. But some of the materials relating with greenhouse cooling was obtained by performing model experiments which include analyzing cooling effect of water sprayed directly on greenhouse roof surface. The results are summarized as follows : 1. The heating requirements of model greenhouse were highly related with the minimum temperature set for given greenhouse. The setting temperature at night-time is much more influential on heating energy requirement than that at day-time. Therefore It is highly recommended that night- time setting temperature should be carefully determined and controlled. 2. The HDH data obtained by conventional method were estimated on the basis of considerably long term average weather temperature together with the standard base temperature(usually 18.3$^{\circ}C$). This kind of data can merely be used as a relative comparison criteria about heating load, but is not applicable in the calculation of greenhouse heating requirements because of the limited consideration of climatic factors and inappropriate base temperature. By comparing the HDM data with the results of simulation, it is found that the heating system design by HDH data will probably overshoot the actual heating requirement. 3. The energy saving effect of night-time thermal curtain as well as estimated heating requirement is found to be sensitively related with weather condition: Thermal curtain adopted for simulation showed high effectiveness in energy saving which amounts to more than 50% of annual heating requirement. 4. The ventilation performances doting warm seasons are mainly influenced by air exchange rate even though there are some variations depending on greenhouse structural difference, weather and cropping conditions. For air exchanges above 1 volume per minute, the reduction rate of temperature rise on both types of considered greenhouse becomes modest with the additional increase of ventilation capacity. Therefore the desirable ventilation capacity is assumed to be 1 air change per minute, which is the recommended ventilation rate in common greenhouse. 5. In glass covered greenhouse with full production, under clear weather of 50% RH, and continuous 1 air change per minute, the temperature drop in 50% shaded greenhouse and pad & fan systemed greenhouse is 2.6$^{\circ}C$ and.6.1$^{\circ}C$ respectively. The temperature in control greenhouse under continuous air change at this time was 36.6$^{\circ}C$ which was 5.3$^{\circ}C$ above ambient temperature. As a result the greenhouse temperature can be maintained 3$^{\circ}C$ below ambient temperature. But when RH is 80%, it was impossible to drop greenhouse temperature below ambient temperature because possible temperature reduction by pad ||||&|||| fan system at this time is not more than 2.4$^{\circ}C$. 6. During 3 months of hot summer season if the greenhouse is assumed to be cooled only when greenhouse temperature rise above 27$^{\circ}C$, the relationship between RH of ambient air and greenhouse temperature drop($\Delta$T) was formulated as follows : $\Delta$T= -0.077RH+7.7 7. Time dependent cooling effects performed by operation of each or combination of ventilation, 50% shading, pad & fan of 80% efficiency, were continuously predicted for one typical summer day long. When the greenhouse was cooled only by 1 air change per minute, greenhouse air temperature was 5$^{\circ}C$ above outdoor temperature. Either method alone can not drop greenhouse air temperature below outdoor temperature even under the fully cropped situations. But when both systems were operated together, greenhouse air temperature can be controlled to about 2.0-2.3$^{\circ}C$ below ambient temperature. 8. When the cool water of 6.5-8.5$^{\circ}C$ was sprayed on greenhouse roof surface with the water flow rate of 1.3 liter/min per unit greenhouse floor area, greenhouse air temperature could be dropped down to 16.5-18.$0^{\circ}C$, whlch is about 1$0^{\circ}C$ below the ambient temperature of 26.5-28.$0^{\circ}C$ at that time. The most important thing in cooling greenhouse air effectively with water spray may be obtaining plenty of cool water source like ground water itself or cold water produced by heat-pump. Future work is focused on not only analyzing the feasibility of heat pump operation but also finding the relationships between greenhouse air temperature(T$_{g}$ ), spraying water temperature(T$_{w}$ ), water flow rate(Q), and ambient temperature(T$_{o}$).

  • PDF