• 제목/요약/키워드: Humidifying modules

검색결과 2건 처리시간 0.017초

기화식 가습기에서 가습모듈 형상에 따른 가습효율의 수치해석 연구 (Numerical Study on the Humidification Efficiency of Humidifying Module Shapes of the Evaporative Humidifier)

  • 김현경;엄태인;문승현;윤형기;방기영
    • 설비공학논문집
    • /
    • 제26권1호
    • /
    • pp.42-47
    • /
    • 2014
  • Adequate relative humidity is needed in the common living space, for human health, and industrial space, for maintenance and efficiency. Evaporative humidifier systems generally have slow response tendencies of air loads, but relatively low initial investment and maintenance costs. Humidification efficiency in the evaporative humidifier is dependent mostly on the shapes and arrays of humidifying modules. So, we tried to apply the computational fluid dynamics to the evaporative humidifier systems, and studied the humidification efficiency of evaporative humidifiers, through the outlet air conditions.

비분산 적외선 이산화탄소 가스센서 특성의 온·습도 영향 (Effects of Temperature and Humidity on NDIR CO2 Gas Sensor)

  • 김진호;이승환
    • 센서학회지
    • /
    • 제26권3호
    • /
    • pp.179-185
    • /
    • 2017
  • This article describes the characteristics of nondispersive infrared carbon dioxide gas sensor according to the temperatures and humidifies. In this researches, a thermopile sensor that included application-specific integrated circuit (ASIC) was used and the White-cell structure was implemented as an optical waveguide. The developed sensor modules were installed in gas chamber and then the temperature of gas chamber has been increased from 283 K to 313 K with 10K temperature step. In order to analyze the effects of humidity levels, the relative humidity levels were changed from 30 to 80%R.H. with small humidifier. Then, the characteristics of sensor modules were acquired with the increment of carbon dioxide concentrations from 0 to 2,000 ppm. When the initial voltages of sensors were compared before and after humidifying the chamber at constant temperature, the decrements of the output voltages of sensors are like these: 9mV (reference infrared sensor), 41 mV (carbon dioxide sensor), 2 mV (temperature sensor). With the increment of ambient temperature, the averaged output voltage of carbon dioxide sensor was increased 19 mV, however, when the humidity level was increased, it was decreased 14mV. Based upon the experimental results, the humidity effect could be alleviated by the increment of temperature, so the effects of humidity and temperature could be only compensated by the ambient temperature itself. The estimated carbon dioxide concentrations showed 10% large errors below 200 ppm, however, the errors of the estimations of carbon dioxide concentrations were less than ${\pm}5%$ from 400 to 2,000 ppm.