• Title/Summary/Keyword: Humid airflow

Search Result 8, Processing Time 0.022 seconds

Effects of Humidity and Velocity on Frost Distribution Characteristics of Humid Air Flow on Cold Surfaces (차가운 표면위에서의 습공기 유동의 습도 및 속도가 착상분포 특성에 미치는 영향)

  • Kwon Jeong-Tae;Rew Keun-Ho;Lim Hyo-Jae;Han Ji-Won;Kwon Young Chul
    • Journal of Energy Engineering
    • /
    • v.14 no.4 s.44
    • /
    • pp.213-218
    • /
    • 2005
  • In order to understand the heat and mass transfer characteristics of humid airflow in frosting conditions, a flat plate of aluminum with cooling modules located in the central part of the plate was used. A microscope system (resolution of 0.05 mm) was used for the measurement of local thickness of frost at seven points along the plate in the flow direction. For the total mass of frost at each test operation, an electronic balance (resolution of 1 mg) was used. The local frost thickness distributions far various test conditions were presented along with the frost mass data measured at the given operating times. The effect of humidity and velocity of humid air on frosting were analyzed.

An Experimental Study on Frosting of Humid Air-flow on a Surface with Local Cooling for Heat Exchanger Design (열교환기 설계를 위한 국소 냉각 표면위에서의 습공기 유동의 착상실험)

  • Kwon, Jeong-Tae;Lim, Hyo-Jae;Park, Kyoung-Woo;Kim, Chang-Eob;Kim, Kyung-Min;Kwon, Young-Chul
    • Journal of Energy Engineering
    • /
    • v.17 no.1
    • /
    • pp.1-7
    • /
    • 2008
  • The present study has been conducted to understand the heat and mass transfer characteristics of humid airflow in frosting conditions. A flat plate of aluminum was used for the simulation of flat surface part of the fin of the heat exchanger. The aluminum surface temperatures were measured and analyzed to clarify the heat and mass transfer characteristics under frosting conditions. Also, the pressure drops were measured to clarify the air-blocking effect of frost in the mini channel of the air-side hoot exchangers. A data reduction method was developed far the analysis of local characteristics of humid air under frosting conditions.

A Study of Frost Formation on Different Hydrophilic Surfaces (다른 친수성능을 가진 두 표면에서의 착상에 관한 연구)

  • 김철환;신종민;하삼철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.6
    • /
    • pp.519-524
    • /
    • 2002
  • An experimental study has been conducted to investigate the effects of surface energy on frost formation. Test samples with two different surfaces are installed in a wind tunnel and exposed to a humid airflow. Dynamic contact angles (DCA) for these surfaces are $23^{\circ}\;and\;88^{\circ}$, respectively. The thickness and the mass of frost layer are measured and used to calculate the frost density while frost formation is visualized simultaneously with their measurements. Results show that frost density increases as time increases at specific test conditions. The air Reynolds number, the airflow humidity and the cold plate temperature are maintained at 12,000, 0.0042 kg/kg and $-21^{\circ}C$, respectively. The surface with a lower DCA shows a higher frost density during two-hour test, but no differences in the frost density have been found after two hours of frost generation. Empirical correlations for thickness, mass and density are assumed to be the functions of the test time and DCA.

A Study on the Room Temperature Control Methods Considering Human Thermal Comfort Under Hot and Humid Condition (인체의 온열환경 적응을 고려한 여름철의 실온 쾌적변동 제어에 관한 연구)

  • Lee, Ju-Youn
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.5
    • /
    • pp.334-341
    • /
    • 2008
  • The purpose of this study is to investigate the effects of changing air temperature and the changing on/off periods of the air-conditioner system. Adding to that, this paper discuss is to consider the effects of air temperature with the air-conditioner system upon the human thermal comfort. The experiment is conducted during the summer. The subjects(6 young females) are exposed to the following conditions: combinations of 2 Swing and 2 Linear air control Conditions. (2 Swing during 40 min, 4 Swing during 40 min, Linear 40 min, Linear 60 min in still air and RH 50%). From the experiment, the following results are obtained; the thermal sensation vote is neutral after 90 minute. The mean skin temperature ranged about $34^{\circ}C$ at all conditions. The skin temperature was greatly affected by 2 Swing big amplitude condition.

Impregnated Active Carbon-Shelf Life Studies and Its Evaluation Against Cyanogen Chloride with and without Canister

  • Singh, Beer;Saxena, Amit;Srivastava, Avanish Kumar;Dubey, Devendra Kumar;Gupta, Arvind Kumar
    • Carbon letters
    • /
    • v.8 no.4
    • /
    • pp.280-284
    • /
    • 2007
  • Samples of active carbon of $1150\;m^2/g$ surface area were impregnated with ammoniacal salts of copper, chromium and silver, with and without triethylenediamine. The samples of impregnated carbon were aged at $50^{\circ}C$, with and without 90% RH (relative humidity), for a little more than one year and chemically evaluated periodically. Initially copper (II) and chromium (VI) reduced very fast in the samples in humid atmosphere to the extent of 30% and 60% respectively in four months. These values were found to be unaffected by the presence of triethylenediamine (TEDA) indicating that the chemical did not retard the reduction process of chromium (VI) and copper (II). However, in the absence of humidity the reduction of the impregnants was significantly less (10-12%, w/w) in four months. It was quite evident; therefore, that the moisture was mainly responsible for the reduction of chromium (VI) and copper (II) species in impregnated carbons. The prolonged ageing of the samples with and without triethylenediamme after four months with and without humid atmosphere showed that the extent of reduction of chromium (VI) was very low, i.e. 5-10% and of copper (II) was 2-25%. Silver is not reduced due to carbon, as it remained unchanged in concentration on storage. The impregnated carbon samples (100 g) without triethylenediamine, which were aged at room temperature for 5 years in absence of humidity and unaged when evaluated against cyanogen chloride (CNCl) at a concentration of 4 mg/L and airflow rate of 30 lpm showed a high degree of protection (80- 110 minutes).

Water-blocking Asphyxia of N95 Medical Respirator During Hot Environment Work Tasks With Whole-body Enclosed Anti-bioaerosol Suit

  • Jintuo Zhu;Qijun Jiang;Yuxuan Ye;Xinjian He;Jiang Shao;Xinyu Li;Xijie Zhao; Huan Xu;Qi Hu
    • Safety and Health at Work
    • /
    • v.14 no.4
    • /
    • pp.457-466
    • /
    • 2023
  • Background: During hot environment work tasks with whole-body enclosed anti-bioaerosol suit, the combined effect of heavy sweating and exhaled hot humid air may cause the N95 medical respirator to saturate with water/sweat (i.e., water-blocking). Methods: 32 young male subjects with different body mass indexes (BMI) in whole-body protection (N95 medical respirator + one-piece protective suit + head covering + protective face screen + gloves + shoe covers) were asked to simulate waste collecting from each isolated room in a seven-story building at 27-28℃, and the weight, inhalation resistance (Rf), and aerosol penetration of the respirator before worn and after water-blocking were analyzed. Results: All subjects reported water-blocking asphyxia of the N95 respirators within 36-67 min of the task. When water-blocking occurred, the Rf and 10-200 nm total aerosol penetration (Pt) of the respirators reached up to 1270-1810 Pa and 17.3-23.3%, respectively, which were 10 and 8 times of that before wearing. The most penetration particle size of the respirators increased from 49-65 nm before worn to 115-154 nm under water-blocking condition, and the corresponding maximum size-dependent aerosol penetration increased from 2.5-3.5% to 20-27%. With the increase of BMI, the water-blocking occurrence time firstly increased then reduced, while the Rf, Pt, and absorbed water all increased significantly. Conclusions: This study reveals respirator water-blocking and its serious negative impacts on respiratory protection. When performing moderate-to-high-load tasks with whole-body protection in a hot environment, it is recommended that respirator be replaced with a new one at least every hour to avoid water-blocking asphyxia.