• Title/Summary/Keyword: Humerus shaft fracture

Search Result 36, Processing Time 0.027 seconds

Results of the Autogenous Sural Nerve Graft for Ruptured Radial Nerve in the Closed Humerus Shaft Fracture (상완골 골절과 동반된 요골 신경 손상에서 자가 비복 신경 이식술의 결과)

  • Lee, Jun-Mo;Lim, Young-Jin;Park, Jong-Hyuk
    • Archives of Reconstructive Microsurgery
    • /
    • v.14 no.2
    • /
    • pp.138-143
    • /
    • 2005
  • In the high radial nerve palsy caused by displaced humeral shaft fracture, radial nerve have to be explored in the fracture site. 5 cases of the ruptured radial nerve at the fracture site of the humerus from January 1993 through January 2005 were treated at first by open reduction and internal fixation with plates and screws fixation and then defective radial nerves were grafted with autogenous sural nerves by microsurgical epineurial and or perineurial neurorrhaphy. At average 30.4 months follow-up, 5 cases were recovered from motor and sensory deficit with solid bony union of the humerus shaft fracture. Authors have confirmed that ruptured radial nerve in the humerus shaft fracture grafted with autogenous sural nerve with microsurgical epineurial and or perineurial neurorrhaphy would be expected good motor and sensory recovery.

  • PDF

Traumatic full thickness rotator cuff tear accompanied by the humerus shaft fracture - A case report - (상완골 간부 골절과 동반된 외상성 회전근 개 전층 파열 - 증례 보고 -)

  • Jeong, Woong-Kyo;Park, Sang-Won;Lee, Soon-Hyuck;Choi, Keun-Seok
    • Clinics in Shoulder and Elbow
    • /
    • v.9 no.2
    • /
    • pp.222-226
    • /
    • 2006
  • Full-thickness rotator cuff tears are relatively uncommon in the young adults. One of the pathogenesis of such tear is thought to be closely related to the specific trauma event. Favorable outcome is expected in young patient rotator cuff tears when it is diagnosed early following prompt surgical repair. However, early detection is sometimes difficult when the acute rotator cuff tear is combined with other injuries especially around the shoulder joints such as ipsilateral humerus fractures. Authors report an uncommon case of acute traumatic rotator cuff tear accompanied by the midhumerus shaft fracture in young adult.

Delayed Diagnosis of Muculocutaneous Nerve Injury Associated with a Humerus Shaft Fracture - A Case Report - (상완골 간부 골절과 동반된 진단이 지연된 근피신경 손상 - 증례 보고 -)

  • Roh, Young-Hak;Kim, Seong-Wan;Chung, Moon-Sang;Baek, Goo-Hyun;Oh, Joo-Han;Lee, Young-Ho;Gong, Hyun-Sik
    • Archives of Reconstructive Microsurgery
    • /
    • v.19 no.1
    • /
    • pp.50-55
    • /
    • 2010
  • Injury of the musculocutanous nerve can be associated with a proximal humeral fracture or shoulder dislocation, and injury of the brachial plexus. However, injury of this nerve associated with a humeral shaft fracture has rarely been reported. Diagnosis of the musculocutaneous nerve injury is difficult because its sensory loss is ill-defined, and examination of elbow flexion is difficult when it is associated with fractures. We report an unusual case of musculocutaneous nerve injury in a 27 years old woman who had multiple injuries including a humerus shaft fracture, an ipsilateral radius shaft fracture, and an associated radial nerve laceration. Diagnosis of the musculocutaneous nerve injury was delayed because combined fractures of the humerus and radius prevented proper examination of the elbow motion and nerve grafting of the radial nerve delayed early elbow motion exercise. Delayed exploration of the musculocutaneous nerve 6 months after trauma showed complete rupture of the nerve at its entry into the coracobrachialis muscle and the defect was successfully managed by sural nerve graft.

  • PDF

The Treatment of Humerus Shaft Simple Fracture by MIPO Technique (상완골 간부 단순 골절에서 최소 침습적 금속판 골유합술을 이용한 치료)

  • Ko, Sang-Hun;Lee, Sun-Ho;Cho, Bum-Keun
    • Clinics in Shoulder and Elbow
    • /
    • v.16 no.1
    • /
    • pp.27-32
    • /
    • 2013
  • Purpose: The purpose of this study is to evaluate the clinical and radiological outcomes of treatment of humerus shaft simple fracture by minimally invasive percutaneous osteosynthesis (MIPO) technique using locking compression plate (LCP). Materials and Methods: Six patients who were operated for humerus shaft simple fracture from August 2010 to May 2011 were enrolled for this study. We checked the cause of injury and the accompanying injuries and evaluated the operation time, the clinical and radiological period of union, postoperative range of motion of the shoulder and elbow joint, pain, activities in daily living, radiologic alignment, and other complications. Results: The clinical period of bone union was 7.2 weeks on average, and the radiologic period of bone union was 8 weeks on average. Follow-up period was more than 12 months in all cases. The angulation through postoperative alignment was 2.8 degrees in AP view and 2 degrees in lateral view. The postoperative range of motion was 167 degrees in forward flexion, 50 degrees in external rotation, and thoracic vertebra 12 level in internal rotation. The average value of visual analogue scale (VAS) was 1.2 and that of KSS was 91.3. The American Shoulder and Elbow Surgeons' score (ASES) was 26.5 and the UCLA score was 31.5. Conclusion: MIPO technique for the humerus shaft simple fracture showed good functional and radiological outcomes and may be considered as one of the treatment options for humerus shaft simple fracture.

A case study of radial nerve injury associated with humerus shaft fracture (상완골 간부 골절에 동반된 요골신경손상에 대한 치험 1례)

  • Lee, Jae-Eun;Lee, Jung-Min;Oh, Min-Seok
    • Journal of Haehwa Medicine
    • /
    • v.23 no.1
    • /
    • pp.157-166
    • /
    • 2014
  • Objective : The purpose of this study is to report the patient with radial nerve injury associated with humerus shaft fracture, who was improved by Korean medical treatments. Methods : The patient was treated by Jungsongouhyul pharmacopuncture, electrical stimulation therapy, physical therapy, and herbal medicine according to "Locating Yang brightness meridians" theory. Coding result, Numeric rating scale(NRS) and digital grip dynamometer were used to evaluate the wrist drop, numbness of fingers and grip power. Results : The patient showed the first sign of recovery after 6 weeks from onset. After 9 weeks from onset, the patient could perform delicate manual activity. Grip power showed noticeable improvement as well as coding result and NRS. Conclusions : The results suggest that providing Korean medical treatments according to "Locating Yang brightness meridians" theory is a good method for treating radial nerve injury associated with humerus shaft fracture. But further studies are required to concretely prove the effectiveness of this method for treating radial nerve injury associated with humerus fracture.

Ultrasonography in Radial Nerve Palsy after Surgery of Humerus Shaft Fracture - Case Report - (상완골 간부 골절 수술 후 발생한 요골신경 마비에서 시행한 초음파 검사 -증례 보고-)

  • Yoon, Hyungmoon;Kho, Dukhwan;Kim, Hyeungjune;Nam, Kyoungmo;Kang, Daemyung
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.5 no.2
    • /
    • pp.106-112
    • /
    • 2012
  • Radial nerve palsy after surgery of humerus fracture is uncommon complication. Occasionally it needs operative treatment because of difficulty to accurate evaluation. We report this case of radial nerve palsy after surgery of humerus shaft fracture with ultrasound examination. We checked the continuity of radial nerve and radial nerve palsy was complete recovered with conservative treatment.

  • PDF

Pathologic Fracture Due to an Osteoblastoma of the Humerus Shaft: A Case Report (골모세포종으로 인한 상완골 간부의 병적 골절: 증례 보고)

  • Yum, Jae-Kwang;Park, Jae-Gu;Kim, Min-Kyu
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.17 no.2
    • /
    • pp.87-90
    • /
    • 2011
  • Osteoblastoma is rare, benign, bone-forming tumor that often occur in the spine. There are few reports of osteoblastomas resulting in pathologic fractures involving long bones. Authos report a unique case of a pathologic fracture due to an osteoblastoma of the humerus shaft. The tumor was treated successfully by curettage, intramedullary nailing and bone allograft.

Operative Treatment with Intramedullary Fibular Strut Allograft for Osteoporotic Proximal Humerus Fracture

  • Chun, Yong-Min;Lee, Wonyong
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.2
    • /
    • pp.95-99
    • /
    • 2017
  • Background: The purpose of this study was to investigate the clinical and radiological outcomes of locking plate fixation with fibular strut allograft to manage unstable osteoporotic proximal humerus fractures. Methods: We retrospectively reviewed 15 patients who underwent open reduction and locking plate fixation with fibular strut allograft for osteoporotic proximal humerus fracture between July 2011 and June 2015. For functional evaluation, we evaluated visual analogue scale (VAS) pain score, American Shoulder and Elbow Surgeons (ASES) score, University of California Los Angeles (UCLA) shoulder score, and active range of motion. For radiological evaluation, shoulder true anteroposterior (AP) and AP in $20^{\circ}$ external rotation, as well as the axillary view were taken at two weeks, six weeks, three months, six months, and one year. And the neck-shaft angle was measured on the AP view in $20^{\circ}$ external rotation view. Results: At the one-year follow-up, mean VAS pain score and all shoulder scores, including ASES score and UCLA shoulder score, exhibited satisfactory clinical outcomes. All patients obtained bone union between three and six months post-procedure. Moreover, the mean immediate postoperative neck-shaft angle was $138^{\circ}{\pm}4^{\circ}$, and at one-year follow-up, the neck shaft angle was $137^{\circ}{\pm}5^{\circ}$. There was no significant difference between the preoperative and postoperative values (p=0.105). Conclusions: For the unstable two-part and three-part osteoporotic proximal humerus fractures with medial calcar comminution, the use of fibular strut allograft with locking plate fixation was effective in maintaining the initial status of reduction and exhibiting the satisfactory functional and radiological outcomes.

An Anterior Approach to Entire Length of Humerus and to Distal Shaft for Fracture Fixation

  • Lee, Chul-Hyung;Choi, Hyun;Kim, Tae-In;Kim, Jun Beom;Shin, Sang Yeop;Rhee, Seung-Koo
    • Clinics in Shoulder and Elbow
    • /
    • v.19 no.4
    • /
    • pp.223-228
    • /
    • 2016
  • Background: The aim of study was to confirm the clinical effectiveness and results of wide and single anterior approach for fractures occurring along length of humerus. Methods: A total of 23 patients with humeral fracture were enrolled into our study who were able to participate in at least one year of follow-up. Seven patients had segmental comminuted humeral fractures and 16 patients had distal humeral fractures. We made various tractions of the muscles to expose the proximal and the middle third humerus between the biceps and brachialis and the distal humerus by partial splitting of lateral side of biceps through a single incision. Postoperatively, we measured the Mayo elbow performance index (MEPI). Results: we achieved bone union in all 23 patients. Solid union of the bone was achieved at an average 13.9 weeks. Postoperatively, two complications were observed screw loosening and nonunion. Revision surgery was performed in both patients. The patient with bone nonunion was treated using bone grafts. No postoperative infections or peripheral neuropathies were observed. At the final follow-up (average 20 months), we found that the average MEPI functional score of the patients was 91.7 points regardless of the fracture site. Conclusions: Our whole humerus with a single incision was effective for the treatment of segmental comminuted and distal fractures. we believe it is a useful alternative to preexisting methods of fracture fixation.

Antegrade Interlocking Intramedullary Nailing in Humeral Shaft Fractures (상완골 간부 골절에서의 전향적 교합성 골수강내 금속정 고정술)

  • Cho, Chul-Hyun;Song, Kwang-Soon;Kim, Sin-Ki
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.1
    • /
    • pp.1-6
    • /
    • 2010
  • Purpose: To evaluate the results and complications of antegrade intramedullary interlocking nailing in humerus shaft fractures. Materials and Methods: We evaluated the clinical outcomes, radiologic results and complications in 47 patients with humerus shaft fracture treated with antegrade intramedullary interlocking nailing, and followed up until bony union. Bony union was confirmed by serial plain radiographs and the clinical outcomes were assessed according to the ASES scoring system. Results: Bony union was confirmed in 41 (87.2%) out of a total 47 patients, and the mean union period was 14.5 weeks. Major complications were as follows: 6 non-union, 3 delayed union, 2 intraoperative posterior cortex fracture in the distal humerus and 2 permanent shoulder pain, including 1 case of adhesive capsulitis. The clinical outcomes were as follows: 29 excellent, 11 good, 4 fair and 3 poor. Satisfactory outcomes were demonstrated in 40 patients (85.1%). Conclusion: Anterograde intramedullary interlocking nailing as treatment for humerus shaft fracture showed satisfactory bony union and clinical outcomes. It is considered an efficacious treatment, especially in patients with associated injury, such as multiple fractures and segmental fracture.