• 제목/요약/키워드: Human respiration

검색결과 134건 처리시간 0.029초

호흡 제어에 따른 임피던스 심장도와 지첨용적맥파에 관한 연구 (The Effect of Controlled Respiration on the Impedance Cardiography and the Second Derivative of PhotoPlethysmography)

  • 고영일;박영배;박영재;이현수
    • 대한한의진단학회지
    • /
    • 제11권1호
    • /
    • pp.82-104
    • /
    • 2007
  • Purpose: We performed this study to examine the effect of controlled respiration on cardiovascular system in healthy adult subjects using impedance cardiography and photoplethysmography. Materials and Methods: This study had performed on 74 subjects, which were healthy men and women without a experience of respiration practice. Using the instruments for impedance cardiography and photoplethysmography, parameters of each subject had been measured after each controlled respirations which were natural respiration, controlled natural respiration (I:E=1.1.6), longer inspiration(I:E=3:3), and longer expiration(I:E=2:4). The measured parameters of impedance cardiography and photoplethysmography were processed statistically by one-way repeated ANOVA. Results: 1. HR and CI of impedance cardiography were decreased significantly during controlled respiration comparing with the result of basal state(the state of enough break). There was no significant difference among the results of controlled respiration. 2. PEP of impedance cardiography had no significant difference among the result of basal state and the results of controlled respiration(p=0.059). 3. VI of impedance cardiography had significant differences among the result of basal state and the results of controlled respiration, and decreased continuously through the controlled respiration. 4. b/a of photoplethysmography had no significant difference among the result of basal state and the results of controlled respiration(p=0.554). 5. c/a of photoplethysmography were decreased significantly during controlled respiration comparing with the result of basal state. There was no significant difference among the results of controlled respiration. 6. d/a of photoplethysmography had significant differences among the results of the controlled respiration decreasing continuously through the controlled respiration and had no significant difference between the result of basal state and the result of natural respiration. 7. AGI of photoplethysmography had significant differences among the result of basal state and the results of the controlled respiration increasing continuously through the controlled respiration. Conclusion: We had examined the effects of controlled respirations on cardiovascular system in multiple points of view. The effects of controlled respirations on cardiovascular system can't be explained in a simple way, as the cardiovascular system is controlled by many factors. Therefore, more physiological parameters must be measured in the future study on the effect of the controlled respiration on human cardiovascular system.

  • PDF

지식(止息)호흡에 대한 인체의 특성연구 (Characteristic Study of Breath-holding)

  • 유승연;오환섭;박영재;박영배
    • 대한한의진단학회지
    • /
    • 제15권1호
    • /
    • pp.95-110
    • /
    • 2011
  • Objectives: The aim of the present study is to define breath-holding in spontaneous respiration and to observe the difference of respiratory variables, EEG and HRV. Methods: 46 healthy young volunteers (M:F=31:15) were recruited in the study. By measuring and analysing respiration, EEG and HRV in the spontaneous respiration. We segment subjects by 100% of coefficient of variation in the breath-holding. Results & Conclusions: 1. There is a period of breath-holding after expiration and before endeavored inspiration, in the course of respiration. The greater coefficient of variation in the breath-holding, longer respiration period mean, inspiration period mean and breath-holding mean in respiratory variable. 2. There was no significant difference between HRV parameters. 3. The greater coefficient of variation in the breath-holding, the higher ${\beta}$ frequency and ${\gamma}$ frequency in the left prefrontal lobe.

맥솔(脈率)과 체성분(體成分) 분석(分析)의 상관성(相關性) 연구(硏究) (Correlation Results of Pulse/Respiration Ratio and Body Composition Analysis)

  • 박재성;박영배;김민용;박영재
    • 대한한의진단학회지
    • /
    • 제10권2호
    • /
    • pp.132-150
    • /
    • 2006
  • Objectives : The objective is that we measure and analyze Pulse-Respiration Ratio and Body Composition Analysis to study the correlation between both. Methods : First, after subjects take a rest over 10 minutes, we measure their electrocardiogram and respiration pattern through which we take average peak interval to calculate an average pulse cycle and a respiration cycle. An average respiration cycle divided by an average Pulse Rate gives Pulse-Respiration Ratio. Next, we draw out 22 Body Composition Analysis indicators by using In-Body 720 model. Last, we analyze and take statistics on them by using SPSS 13.0 program. Results : Negative is the correlation between P/R Ratio and Body Composition Analysis indicator like fatness degree, body fat volume, body fat rate, abdominal fatness, BMI. Conclusions : 1. The higher P/R Ratio the more likely to be thin, the lower P/R Ratio the more likely to be fat. 2. We separately analyze P/R Ratio depending on each breathing frequency and pulse frequency to find out that breathing frequency has great influence and that breathing frequency decides the fatness degree. 3. In study on the correlation between P/R Ratio and Body Composition Analysis, fatness degree, in-body fat volume, in-body fat rate, BMI are the related indicators, which shows the connection with the fatness indicators. 4. In study on the correlation between Han-Yeol [寒熱] grade and Body Composition Analysis indicators, the result is that Han[寒] has no connection and that only Yeol[熱] grade has something to do with it, which means the higher heat symptom subjects have, the more basic metabolism volume and muscular build they have.

  • PDF

호흡조절에 따른 위전도와 심박변이도 변화 연구 (The Study on the Change of EGG and HRV through Respiratory Control)

  • 하성룡;박영배;양동훈;박영재;김민용
    • 대한한의진단학회지
    • /
    • 제11권1호
    • /
    • pp.157-166
    • /
    • 2007
  • Background: The change in the respiratory pattern has an influence on the change in the autonomic nervous system, which in turn has an influence on the EGG to measure a gastric activity. However, the study on the influence on the EGG parameters by respiratory control and on the correlation between the HRV and EGG through respiratory control has not been perform yet. Objective: It is to perform a series of experiments to find out how the EGG parameters are influenced by the controlled respiration and what correlation there may exist between the EGG and HRV to measure the change in the autonomic nervous system after controlled respiration. Methods: 1st Experiment: During a 15minutes' voluntary respiration, HRV was measured, and it was measured again during another 15 minutes' controlled respiration. 2nd Experiment: After an eight hours' fast, EGG was measured for a period of 30 minutes, and then after another 15 minutes' voluntary respiration, a test-meal was offered for 10 minutes and again EGG was measured. The next day, after an 8 hour's fast, EGG was measured for 30 minutes, and after a 15 minutes' controlled respiration and offered with a test-meal for 10 minutes and then EGG was measured again for 30 minutes. Results: 1. It was observed in all the channels that the power ratio increased more after controlled respiration than after voluntary respiration. No statistical significance, however, could be observed. 2. Through controlled respiration, the HF of HRV and the power ratio of EGG Channel 4 was negatively correlated, while the LF/HF of HRV and the power ratio of EGG channel 1 & 4 was positive correlated. Such correlations as mentioned above, however, could not be observed in HRV & EGG through voluntary respiration. Conclusions: 1. It was concluded that the increase in the power of gastric contractile after controlled respiration is bigger than the increase in the power of gastric contractile after voluntary respiration. 2. It was concluded that the gastric contractile power and sympathetic activity through controlled respiration was negatively correlated, while the gastric contractile power and parasympathetic activity through controlled respiration was positively correlated.

  • PDF

체표온도특성(體表溫度特性)과 맥율(脈率)의 상관성(相關性) 연구(硏究) (A Study of Correlation between Pulse-Respiration Ratio and Characteristics of Thermal Temperature)

  • 이혁재;박영재;박영배;오환섭
    • 대한한의진단학회지
    • /
    • 제12권1호
    • /
    • pp.103-130
    • /
    • 2008
  • Background: For standardizing of Han-Yeol [寒熱], which is a kind of diagnosis method in oriental medicine, it is necessary to investigate into relationship of symptoms and signs representative of Han-Yeol [寒熱] to the biofunctional medical signals; thermal temperature by Thermography, Pulse-Respiration Ratio and so on. By correlation analysis of these data items acquired from patients, it could be provides the fundamental data for standardizing of Han-Yeol [寒熱]. Objectives: We performed this study to check the characteristics of thermal temperature with Han-Yeol [寒熱] statue by pulse-respiration ratio. Methods: We selected nine regions around acupoints including Yin dang[印堂], Sugu[水溝, GV26], Ch'ondol[天突, CV22], Chonjung[CV17], Chung-wan[中脘, CV12], Chonchu[天樞 S25], No-gung[勞官, P8], and calculated based on the utility of R.O.I.(Region of Integer) by IR-2000 these points temperature from 68 subjects. In practicing pulse-respiration ratio over 4.0 means the statues of Yeol [熱], pulse-respiration ratio below 4.0 means the statues of Han [寒]. To optimum conditions thermal temperature, which are not effected by internal and external variables, we studied preceding research. The results shows that optimal time period is 20minutes after undressed and the optimal region is the region around acupoints including Sugu [水溝, GV26]. Based on a preceding research results, we analyzed these data by Paired T-test between GV26 Region and 8-Thermography Regions and two-way repeated ANOVA with thermography$({\Delta}T)$ and Han-Yeol [寒熱] statue by pulse-respiration ratio. Results: 1. In applying of two-way repeated ANOVA with thermography$({\Delta}T)$ and Han-Yeol [寒熱] statue by pulse-respiration ratio, Sugu [水溝穴, GV26] - [印堂穴, HN1], Sugu 水溝, GV26] - Chonjung[CV17], Sugu [水溝, GV26] -Chung-wan[中脘, CV12]had significant differences. 2. In applying of Paired T-test between Sugu [水溝穴, GV26] Region and 8- Thermography Regions, there were significant differences except of Sugu [水溝穴, GV26] -Chondolp[天突, CV22]. 3. In the difference of Sugu [水溝, GV26] -Chung-wan[中脘, CV12], thermal temperature increases a lot in the statues of Yeol [熱], thermal temperature decreases a lot in the statues of Han [寒]. Conclusions: On the analysis of Thermography, we obtain the measurement conditions were considered the individual variations. And it is different that the thermal temperature change on Thermography according to Han-Yeol [寒熱] statue by pulse-respiration ratio.

  • PDF

U-Health Care 환경에서 호흡측정을 위한 PPG 최적필터기술 (PPG Filtering Method for Respiration Measurement in U-Health Care System)

  • 김종화;황민철;남기창
    • 대한인간공학회지
    • /
    • 제27권4호
    • /
    • pp.95-101
    • /
    • 2008
  • This research is to develop PPG filtering method for respiration measurement in U-Health Care system. Respiration rate was determined by filtering PPG and analyzing its spectrum. Optimal filter of PPG has been selected to get respiration by testing 120 sets of experiment data using 700 filtering cases. As a result, 2nd order Bessel-filter that used band-pass cutoff frequency at 0.175~0.4Hz with second order was good at developing respiration signal. Respiration signal in time domain could be continuously analyzed by converting frequency domain using spectrum analysis. 24 seconds has been found to be optimal time duration of collecting PPG data for determining respiration. Therefore, this study was successful of getting not only heart activity but also respiration by only PPG. Minimal invasive measurement obtaining multi-bio information by one sensor can be expected to apply to U-Health Care and human computer interaction.

Simultaneous Blockage of Epidermal Growth Factor Receptor and Cyclooxygenase-2 in a Human Xenotransplanted Lung Cancer Model

  • Mu, Xiao-Yan;Dong, Xue-Li;Sun, Jie;Ni, Yu-Hua;Dong, Zhang;Li, Xi-Li;Sun, Er-Lian;Yi, Zhou;Li, Gao
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권1호
    • /
    • pp.69-73
    • /
    • 2014
  • The effects of erlotinib combined with celecoxib in a lung cancer xenograft model were here explored with a focus on possible mechanisms. A xenotransplanted lung cancer model was established in nude mice using the human lung cancer cell A549 cell line and animals demonstrating tumour growth were randomly divided into four groups: control, erlotinib, celecoxib and combined (erotinib and celecoxib). The tumor major axis and short diameter were measured twice a week and after 40 days tissues were collected for immunohistochemical analyses of Bcl-2 and Bax positive cells and Western-blotting analyses for the epidermal growth factor recepto (EGFR), P-EGFR, and cyclooxygenase-2 (COX-2). Tumor size in the combined group was smaller than in the others (p<0.01) and the percentage of Bcl-2 positive cells was fewer in most cases (p<0.01), while that of Bax positive cells was greater than in the erlotinib and celecoxib groups (P>0.05). Western blotting showed decreased expression of P-EGFR and COX-2 with both erlotinib and celecoxib treatments, but most pronouncedly in the combined group (P<0.05). Simultaneous blockage of the EGFR and COX-2 signal pathways exerted stronger growth effects in our human xenotransplanted lung cancer model than inhibition of either pathway alone. The anti-tumor effects were accompanied by synergetic inhibition of tumor cell apoptosis, activation of p-EGFR and expression of COX-2.

유방암 환자의 Field-in-Field Technique 치료 시 호흡의 움직임에 따른 선량 평가 (Evaluation of the Dose According to the Movement of Breath During Field-in-Field Technique Treatment of Breast Cancer Patients)

  • 권경태
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권6호
    • /
    • pp.561-566
    • /
    • 2018
  • Field-in-Field Technique is applied to the radiation therapy of breast cancer patients, and it is possible to compensate the difference in breast thickness and deliver uniform dose in the breast. However, there are several fields in the treatment field that result in a more complex dose delivery than a single field dose delivery. If the patient's respiration is irregular during the delivery of the dose by several fields and the change of respiration occurs, the dose distribution in the breast changes. Therefore, based on the computed tomography images of breast cancer patients, a human model was created by using a 3D printer (Builder Extreme 1000) to describe the volume in the same manner. A computerized tomography (CT) of the human body model was performed and a treatment plan of 260 cGy / fx was established using a 6-MV field-in-field technique using a computerized treatment planning system (Eclipse 13.6, Varian, USA). The distribution of the dose in the breast according to the change of the respiration was measured using a moving phantom at 0.1 cm, 0.3 cm, 0.5 cm amplitude, using a MOSOXIDE Silicon Field Effect Transistor (MOSFET, Best Medical, Canada) Were measured and compared. The distribution of dose in the breast according to the change of respiration showed similar value within ${\pm}2%$ in the movement up to 0.3 cm compared to the treatment plan. In this experiment, we found that the dose distribution in the breast due to the change of respiration when the change of respiration was increased was not much different from the treatment plan.

초등학생의 호흡 개념 이해에 대한 연구 (A Cross-age Study on Elementary Students이 Understanding of the Concept of Respiration)

  • 성정희;김영수
    • 한국초등과학교육학회지:초등과학교육
    • /
    • 제19권2호
    • /
    • pp.57-74
    • /
    • 2000
  • Students' concepts of scientific phenomena have become a point of focus in science education research. This study investigated into developmental process and mechanism of the students' respiration concept through a cross-age study. This study utilized the 1st, 3rd, 6th grade elementary students to find out changes in student's understanding of the concept of respiration. The 1st and 3rd grade level students were interviewed what the respiration mean and whether each of living things respires, etc. The 6th grade students were interviewed and tested. Respiration is a word that students come across often in everyday life. It was found that they were more likely to associate respiration with its more common concept of breathing or gas exchange as opposed to its more scientific definition as the process in which nutrients are oxidized to provide energy. This trend didn't improve as they advanced grade. This is an indication that the knowledge system of student is split into a generic knowledge system and scientific knowledge system. Understanding of concept increased and differentiated across grade levels but that understanding was limited. They overcome their tendency to base their understanding of respiration on their understanding of human phenomena and learn to integrate their understanding of biological phenomena through a one organ - one role type of logic. They also intuitively explain everything based on their own experience.

  • PDF

명상호흡 모니터링용 스마트의류를 위한 호흡수 측정 직물센서 연구 (A Study on the Textile Sensor Applied to Smart Wear for Monitoring Meditation Breathing)

  • 황수정;정윤원;이주현
    • 감성과학
    • /
    • 제21권1호
    • /
    • pp.83-90
    • /
    • 2018
  • 본 연구의 목적은 정신적, 신체적 힐링을 위한 명상용 스마트 의류 개발을 위한 기초연구로서 명상 시 복식호흡 수를 측정함으로써, 의복을 통해 명상의 진입상태를 모니터링 하기 위한 방법을 연구하는 것이다. 이를 위해 본 연구에서는 Single Wall Carbon Nano-Tube (SWCNT)를 기반으로 한 스트레인 게이지 타입의 직물센서를 구현하고, 1차 실험으로 0.1 Hz의 주기로 복부형태의 더미를 5 cm 길이로 2분간 개폐를 반복하여 명상호흡을 시뮬레이션 한 결과 참조전극인 BIOPAC과 직물호흡센서의 신호가 매우 높은 일치도를 나타냈다(p<0.001). 같은 조건으로 2차 본 실험에서 피험자 4명에게 명상호흡을 수행하도록 하였고, 배꼽점, 횡경막 부근 중심과 측면 총 4군데 위치에서 출력된 전압 값을 비교한 결과 배꼽점 중심 위치와 횡경막 측면에서 신호의 일치도가 높고, 크고 안정된 신호형태를 보여 명상호흡을 측정하기에 적합한 위치로 선정되었다. 따라서 본 연구에서는 긴 호흡주기의 명상호흡을 측정하기 위한 직물센서를 구현하고, 이 센서의 명상 호흡수 측정을 위한 신뢰성과 타당성을 검토하며, 인체 상 측정위치에 따른 호흡 수 측정효율을 비교, 고찰하는 것을 목표로 하였다.