• 제목/요약/키워드: Human arm impedance

검색결과 17건 처리시간 0.028초

생체 임픽던스 측정에 의한 상지 운동 감지 시스템 (A Human Arm Movement Detection System Using Electrical Bioimpedance Measurement)

  • 김종찬;김수찬;남기창;박민용;김경환;김덕원
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제51권8호
    • /
    • pp.374-379
    • /
    • 2002
  • In this study, we developed a new human arm movement detection system using electrical bio-impedance method with several skin-electrodes. The correlation coefficients of the joint angle and the impedance change from human arm movement was obtained using a goniometer and impedance measurement system developed in this study. The correlation coefficients of the wrist and the elbow movements were 0.94 and -0.99, respectively. This system was applied to control a robotic arm by converting the measured impedance to joint angle to confirm the validity of the proposed system. In conclusion, we confirmed that this system can control the robotic arm according to arm movement without any limitation of movement. This system showed possibility that upper arm movement could be easily measured by impedance measurement system with a few skin-electrodes.

개인차 보상을 고려한 팔운동감의 정량화 방법 (Quantification Method of Kinesthetic Sense of Arm with Compensation for Individual Difference)

  • 정웅철;송재복;김용일
    • 한국정밀공학회지
    • /
    • 제17권2호
    • /
    • pp.227-234
    • /
    • 2000
  • The human sensibility caused by the motion of an object grasped by a human operator is defined as kinesthetic sense of arm. Due to nonlinearity and ambiguity of human sense, there is no absolute standard for quantification of kinesthetic sense. In this research, a so-called 2-dimensional arm motion generator is developed to present various mechanical impedance (i.e., stiffness or damping) characteristics to a human arm. The kinesthetic words representing arm kinesthetic sense are selected and then the subject's satisfaction levels on these words for given impedance values are measured and processed by the SD method and factor analysis. In addition, the quantification method using neural network is proposed to take into account the individual difference between the mean sensibility and each subject's sensibility. Through this proposed algorithm, the sensibility of human motion described qualitatively can be converted into engineering data ensuring objectivity, reproducibility, and universality.

  • PDF

Impedance characteristic of human arm for cooperative robot

  • Rahman, Mozasser;Ikeura, Ryojun;Mizutani, Kazuki
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2002년도 ICCAS
    • /
    • pp.85.3-85
    • /
    • 2002
  • In this study, we tried to investigate the impedance characteristic of human arm in a cooperative task. Human arm was moved in a desired trajectory. The motion was actuated by a 1 degree-of-freedom robot system. As the muscle is mechanically analogous to a spring-damper system, a second-order equation was considered as the model for arm dynamics. In the model, inertia, stiffness and damping factor were considered. The impedance parameter was estimated from the position and torque data obtained from the experiment and based on the "Estimation of Parametric Model". It was found that the inertia is almost constant over the operational time. The damping factor and stiffness were high...

  • PDF

생체임피던스에 의한 상지운동 감지를 위한 최적 전극 위치의 평가 및 검증 (Evaluation and Verification of Optimal Electrode Configurations for Detection of Arm Movement Using Bio-Impedance)

  • 안선희;김수찬;남기창;김덕원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.399-402
    • /
    • 2002
  • In this study, we constructed a four-channel impedance measurement system including a two-channel goniometer to analyze human arm movement. Impedances and joint angles were simultaneously measured for wrist and elbow movements. As the impedance changes resulting from wrist and elbow movements depended heavily on electrode placement, we determined the optimal electrode configurations for those movements by searching for high correlation coefficients, large impedance changes, and minimum interferences in ten subjects (age: 29+6). Our optimal electrode configurations showed very strong relationships between the wrist joint angle and forearm impedance (correlation coefficient = 0.95+0.04), and between the elbow joint angle and upper arm impedance (correlation coefficient = -0.98+0.02). Although the measured impedances changes of the wrist (1.1+1.5 ohm) and elbow (-5.0+2.9 ohm) varied among individuals, the reproducibilities of wrist and elbow impedance changes of five subjects were 5.8+1.8 % and 4.6+1.4 % for the optimal electrode pairs, respectively. We propose that this optimal electrode configuration would be useful for future studies involving the measurement of accurate arm movements by impedance method.

  • PDF

양방향 제어를 이용한 가상환경에서의 팔운동감 제시 (Reproduction of Arm Kinesthetic Sense in Virtual Environment Using Bilateral Control)

  • 정웅철;민두기;송재복;김용일
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 1999년도 추계학술대회 논문집
    • /
    • pp.97-100
    • /
    • 1999
  • Human feels kinesthetic sense in response to the force acted on him. In order to represent kinesthetic sense, a force is analyzed as mechanical impedance (i.e., stiffness or damping) and implemented by active impedance control. In this research, a 3-dimensional arm motion generator is developed to present various mechanical impedance characteristics to an operator. An introduction of virtual reality provides not only a visual effect in virtual environment but also the change in force synchronized with the visual effect in real time.

  • PDF

힘 제어 기반의 로봇 팔과 인간 팔의 상호 작용을 위한 임베디드 시스템 설계 (Implementation of an Embedded System for an Interaction between Robot Arm and Human Arm Based on Force Control)

  • 전효원;정슬
    • 제어로봇시스템학회논문지
    • /
    • 제15권11호
    • /
    • pp.1096-1101
    • /
    • 2009
  • In this paper, an embedded system has been designed for force control application to interact between a robot arm and a human operator. Force induced by the human operator is converted to the desired position information for the robot to follow. For smooth operations, the impedance force control algorithm is utilized to represent interaction between the robot and the human operator by filtering the force. To improve the performance of position control of the robot arm, a velocity term has been obtained and tested by several filters. A PD controller for position control has been implemented on an FPGA as well. Experimental studies are conducted with the ROBOKER to test the functionality of the designed hardware.

Human Arm Posture Control Using the Impedance Controllability of the Musculo-Skeletal System Against the Alteration of the Environments

  • Kim, Jaehyo;Makoto Sato;Yasuharu Koike
    • Transactions on Control, Automation and Systems Engineering
    • /
    • 제4권1호
    • /
    • pp.43-48
    • /
    • 2002
  • We show that humans execute the postural control ingeniously by regulating the impedance properties of the musculo-skeletal system as the motor command against the alteration of the environment. Adjusting muscle activity can control the impedance properties of the musculo-skeletal system. To quantify the changes in human arm viscoelasticity on the vertical plane during interaction with the environment, we asked our subject to hold an object. By utilizing surface electromyographic(EMG) studies, we determined a relationship between the perturbation and a time-varying muscle co-activation. Our study showed when the subject lifts the object by himself the muscle stiffness increases while the torque remains the same just before the lift-off. These results suggest that the central nervous system(CNS) simultaneously controls not only the equilibrium point(EP) and the torque, but also the muscle stiffness as themotor command in posture control during the contact task.

Experimental study on impedance characteristics of a human upper link in a positioning motion

  • Kobayashi, Hideaki;Inooka, Hikaru;Ikeura, Ryojun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 Proceedings of the Korea Automatic Control Conference, 11th (KACC); Pohang, Korea; 24-26 Oct. 1996
    • /
    • pp.247-250
    • /
    • 1996
  • In this paper, we have examined the impedance characteristics of a tipper link of human being in a positioning motion. Firstly, we have shown the characteristics of the human arm using a bilinear model. From the bilinear model, we have observed that both the driving torque of the forearm and the visco-elasticity of the elbow joint can be controlled by muscles, respectively. Then, we have defined several indexes to show the impedance characteristics. Using the proposed indexes, we have examined the impedance characteristics in the positioning operation. As a result, we can not observe the difference of the impedance characteristics, even if the ease of the positioning motion is varied.

  • PDF

중력 보상 팔 기능 지지대의 설계 및 제어 성능 평가 (Design and Evaluation of the Control Performance of a Compliant Arm Support)

  • 김상훈;정우석;박대근;구인욱;조규진
    • 한국정밀공학회지
    • /
    • 제34권2호
    • /
    • pp.115-123
    • /
    • 2017
  • This paper presents the design and the control performance of a novel dynamic compliant-arm support with parallel elastic actuators that was developed to assist with the daily living activities of those whose arms are compromised by muscular disease or the aging process. The parallel elastic-arm support consists of a compliant mechanism with combined passive and active components for human interaction and to reach the user's desired positions. The achievement of these tasks requires impedance control, which can change the virtual stiffness, damping coefficients, and equilibrium points of the system; however, the desired-position tracking by the impedance control is limited when the end-effector weight varies according to the equipping of diverse objects. A prompt algorithm regarding weight calibration and friction compensation is adopted to overcome this problem. A result comparison shows that, by accurately assessing the desired workspace, the proposed algorithm is more effective for the accomplishment of the desired activities.