• Title/Summary/Keyword: Human Impedance

Search Result 201, Processing Time 0.034 seconds

The Effect of Controlled Respiration on the Impedance Cardiography and the Second Derivative of PhotoPlethysmography (호흡 제어에 따른 임피던스 심장도와 지첨용적맥파에 관한 연구)

  • Ko, Young-Il;Park, Young-Bae;Park, Young-Jae;Lee, Hyon-Soo
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.11 no.1
    • /
    • pp.82-104
    • /
    • 2007
  • Purpose: We performed this study to examine the effect of controlled respiration on cardiovascular system in healthy adult subjects using impedance cardiography and photoplethysmography. Materials and Methods: This study had performed on 74 subjects, which were healthy men and women without a experience of respiration practice. Using the instruments for impedance cardiography and photoplethysmography, parameters of each subject had been measured after each controlled respirations which were natural respiration, controlled natural respiration (I:E=1.1.6), longer inspiration(I:E=3:3), and longer expiration(I:E=2:4). The measured parameters of impedance cardiography and photoplethysmography were processed statistically by one-way repeated ANOVA. Results: 1. HR and CI of impedance cardiography were decreased significantly during controlled respiration comparing with the result of basal state(the state of enough break). There was no significant difference among the results of controlled respiration. 2. PEP of impedance cardiography had no significant difference among the result of basal state and the results of controlled respiration(p=0.059). 3. VI of impedance cardiography had significant differences among the result of basal state and the results of controlled respiration, and decreased continuously through the controlled respiration. 4. b/a of photoplethysmography had no significant difference among the result of basal state and the results of controlled respiration(p=0.554). 5. c/a of photoplethysmography were decreased significantly during controlled respiration comparing with the result of basal state. There was no significant difference among the results of controlled respiration. 6. d/a of photoplethysmography had significant differences among the results of the controlled respiration decreasing continuously through the controlled respiration and had no significant difference between the result of basal state and the result of natural respiration. 7. AGI of photoplethysmography had significant differences among the result of basal state and the results of the controlled respiration increasing continuously through the controlled respiration. Conclusion: We had examined the effects of controlled respirations on cardiovascular system in multiple points of view. The effects of controlled respirations on cardiovascular system can't be explained in a simple way, as the cardiovascular system is controlled by many factors. Therefore, more physiological parameters must be measured in the future study on the effect of the controlled respiration on human cardiovascular system.

  • PDF

A monitoring apparatus for pulse shape of human heartbeats by magnetic impedance sensors (자기 임피던스 센서를 이용한 맥박 측정 장치)

  • Kim, Cheong-Worl;Gu, Bon-Ju;Kim, Jong-Seong
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.77-83
    • /
    • 2006
  • A monitoring apparatus for pulse shapes of human heartbeats has been developed using an amorphous MI(Magnetic Impedance) sensor. The pulse shapes are successfully obtained from voltage signals due to the variations of magnetic impedance in the amorphous MI sensor, which is attached to a patient's wrist. This voltage signal was fed into a signal processing module to extract the pulse shapes of heartbeats. The signal processing module, which is proposed to detect a weak variations of impedance in MI sensor under a noisy measurement environment, consists of a high frequency current source, an amplifier stage and a synchronous detection circuit. To evaluate the characteristics of a newly developed apparatus, various experiments were performed. The experimental results show that the developed apparatus could be used as a diagnosis tool for traditional Korean medicine with further systematic clinical studies.

A Characteristics of Human Skin Impedance Including at Biological Active Points

  • Lee, J. W.;Kim, D. M.;H. G. Lim;Park, I. Y.;J. H. Cho
    • Proceedings of the IEEK Conference
    • /
    • 2002.07a
    • /
    • pp.440-442
    • /
    • 2002
  • The electrical characteristics of biologically active points (BAPs) compared with those of the surrounding human skins are studied. And we confirm that BAPs have lower resistance and higher capacitance than the surrounding skins do. We also find that BAPs have higher characteristic frequency than surrounding skins and the impedance spectra of BAPs sometimes have two semicircles on the complex impedance plane. We propose the skin impedance model that is proper to the BAPs and this circuit describes our experimental results sufficiently well.

  • PDF

Sensorless Force Control with Observer for Multi-functional Upper Limb Rehabilitation Robot (다기능 재활운동을 위한 힘 센서가 없는 상지 재활 로봇의 힘 제어)

  • Choi, Jung Hyun;Oh, Sehoon;An, Jinung
    • The Journal of Korea Robotics Society
    • /
    • v.12 no.3
    • /
    • pp.356-364
    • /
    • 2017
  • This paper presents a force control based on the observer without taking any force or torque measurement from the robot which allows realizing more stable and robust human robot interaction for the developed multi-functional upper limb rehabilitation robot. The robot has four functional training modes which can be classified by the human robot interaction types: passive, active, assistive, and resistive mode. The proposed observer consists of internal disturbance observer and external force observer for distinctive performance evaluation. Since four training modes can be quantitatively identified as impedance variation, position-based impedance control with feedback and feedforward controller was applied to the assistive training mode. The results showed that the proposed sensorless observer estimated cleaner and more accurate force compared to the force sensor and the impedance controller embedded with the proposed observer completed the assistive training mode safely and properly.

Variable Impedance Control for Industrial Manipulators Based on Sensor-Less External Force Estimator for CPPS (CPPS를 위한 산업용 매니플레이터의 힘 센서리스 외력 추정기 기반 적응 임피던스 제어)

  • Park, Jongcheon;Han, Seungyong;Jin, Yongsik;Lee, Sangmoon
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.14 no.5
    • /
    • pp.259-267
    • /
    • 2019
  • This paper proposes a structure of a variable impedance control system based on sensor-less external force estimator of industrial manipulators for cyber physical production systems (CPPS). To implement CPPS, a feedback system is constructed by using the robot operating system (ROS) and an external force estimator which is designed to measure the external force applied to the manipulator without a force sensor. Based on the robot dynamics, the robot-human cooperating system for the cyber physics production system is implemented through a controller that changes the impedance characteristics of the manipulator according to the situation using the external force estimator. Simulation and experimental results verify the effectiveness of the proposed control system.

Impedance characteristic of human arm for cooperative robot

  • Rahman, Mozasser;Ikeura, Ryojun;Mizutani, Kazuki
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.85.3-85
    • /
    • 2002
  • In this study, we tried to investigate the impedance characteristic of human arm in a cooperative task. Human arm was moved in a desired trajectory. The motion was actuated by a 1 degree-of-freedom robot system. As the muscle is mechanically analogous to a spring-damper system, a second-order equation was considered as the model for arm dynamics. In the model, inertia, stiffness and damping factor were considered. The impedance parameter was estimated from the position and torque data obtained from the experiment and based on the "Estimation of Parametric Model". It was found that the inertia is almost constant over the operational time. The damping factor and stiffness were high...

  • PDF

Comparison of the Standard Floor Impact Source with the Human Impact Source (표준충격원과 실충격원의 특성 비교)

  • Lee, Pyoung-Jik;Jeong, Jeong-Ho;Jeon, Jin-Yong;Park, Jun-Hong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.804-807
    • /
    • 2005
  • The characteristics of the standard floor impact sources and the human impact source were investigated. First, the mechanical impedance of the each source was evaluated. Second, the impact force exposure levels and impact sounds level driven by the each source were measured. The results showed that the mechanical impedance and impact force exposure level of the impact ball are the most similar to those of the human impact source among the standard impact sources.

  • PDF

The Controlled Impedance Measurement on the PCB

  • Park, Min-Ju;Lee, Jae-Kyung;Yoon, Dal-Hwan;Min, Seung-Gi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.113-117
    • /
    • 2003
  • The digital systems include the noise in power supply, ground and packaging due to a simultaneous switching of signal, signal reflections and distortions on single and multiple transmission lines. The requirement for the controlled impedance on a PCB can be both a critical success factor and a design challenge. So, the invented tool simulates the tracks controlled impedance with the test coupon. It can saves the design time and supports the economical PCB design.

  • PDF

Electrical Impedance Tomography as a Primary Screening Technique for Breast Cancer Detection

  • Akhtari-Zavare, Mehrnoosh;Latiff, Latiffah A
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.14
    • /
    • pp.5595-5597
    • /
    • 2015
  • Electrical impedance tomography (EIT) is a new non-invasive, mobile screening method which does not use ionizing radiation to the human breast. It is based on the theory that cancer cells display altered local dielectric properties, thus demonstrating measurably higher conductivity values. This article reviews the utilisation of EIT in breast cancer detection. It could be used as an adjunct to mammography and ultrasonography for breast cancer screening.

Measurement of Body Fat by Impedance Technique (임피던스 방법을 이용한 체지방 측정)

  • Kim, Deok-Won;Song, Chul-Gyu;Hwang, Soo-Kwan
    • Journal of Biomedical Engineering Research
    • /
    • v.13 no.2
    • /
    • pp.133-140
    • /
    • 1992
  • Bioelectrical Impedance method for measuring human body composition is based upon the principle that the electrical conductivity of the fat-free mass (FFM) is far greater than that of the (at. Deter- mination o( impedance was nlade in 30 healthy and obese men aged $40.9{\pm}14.7$yr (mean${\pm}$SD) and 25 healthy and obese women aged $44.0{\pm}10.2$ yr. A commercial impedance body fat analyzer was used with a four electrode arrangement that introduced a painless constant current(ImA at 50 kHz) into the body. Linear relationships were found between impudence values and FFM(r=-0.786) and between weight and FFM(r=0.837). Signigicant increases in the correlation coefficients were ob served when the predicator Hta/z was regressed against FFM(r=0.912) where Ht Is height and Z Is impedance. A linear regression equation, FFM=0.586(Htf/z) +0.317(Weight) -1.674(r=0.977), was found. The correlation coefficient of % body fat between the impedance and infrared methods was 0.898. These data Indicate that the bioelectrical impedance technique is a reliable and valld approach for the estimation of human body composition. This method Is safe, noninvasivr, prouides rapld measure menu, requires little operator skill and subject cooperation, and Os portable. Finally measurement of percent body fat was made possible using both the regression equation and a developed impedance measuring device which measures impedance between wrist and ankle.

  • PDF