• Title/Summary/Keyword: Human Body Detection

Search Result 207, Processing Time 0.032 seconds

Recognition of Events by Human Motion for Context-aware Computing (상황인식 컴퓨팅을 위한 사람 움직임 이벤트 인식)

  • Cui, Yao-Huan;Shin, Seong-Yoon;Lee, Chang-Woo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.14 no.4
    • /
    • pp.47-57
    • /
    • 2009
  • Event detection and recognition is an active and challenging topic recent in Computer Vision. This paper describes a new method for recognizing events caused by human motion from video sequences in an office environment. The proposed approach analyzes human motions using Motion History Image (MHI) sequences, and is invariant to body shapes. types or colors of clothes and positions of target objects. The proposed method has two advantages; one is thant the proposed method is less sensitive to illumination changes comparing with the method using color information of objects of interest, and the other is scale invariance comparing with the method using a prior knowledge like appearances or shapes of objects of interest. Combined with edge detection, geometrical characteristics of the human shape in the MHI sequences are considered as the features. An advantage of the proposed method is that the event detection framework is easy to extend by inserting the descriptions of events. In addition, the proposed method is the core technology for event detection systems based on context-aware computing as well as surveillance systems based on computer vision techniques.

Vision-Based Identification of Personal Protective Equipment Wearing

  • Park, Man-Woo;Zhu, Zhenhua
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.313-316
    • /
    • 2015
  • Construction is one of the most dangerous job sectors, which reports tens of thousands of time-loss injuries and deaths every year. These disasters incur delays and additional costs to the projects. The safety management needs to be on the top primary tasks throughout the construction to avoid fatal accidents and to foster safe working environments. One of the safety regulations that are frequently violated is the wearing of personal protection equipment (PPE). In order to facilitate monitoring of the compliance of the PPE wearing regulations, this paper proposes a vision based method that automatically identifies whether workers wear hard hats and safety vests. The method involves three modules - human body detection, identification of safety vest wearing, and hard hat detection. First, human bodies are detected in the video frames captured by real-time on-site construction cameras. The detected human bodies are classified into with/without wearing safety vests based on the color features of their upper parts. Finally, hard hats are detected on the nearby regions of the detected human bodies and the locations of the detected hard hats and human bodies are correlated to reveal their corresponding matches. In this way, the proposed method provides any appearance of the workers without wearing hard hats or safety vests. The method has been tested on onsite videos and the results signify its potential to facilitate site safety monitoring.

  • PDF

Compact Microwave Heartbeat Proximity Sensor Under Human Body Movement (인체 움직임을 고려한 소형 근접 마이크로파 심박 센서)

  • Yun, Gi-Ho
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.10
    • /
    • pp.63-69
    • /
    • 2020
  • In this paper, a small microwave sensor that can be applied to a wearable device is proposed because it can detect the heartbeat signal of a human body moving irregularly at low speed. It consist of balanced microstrip radiation patches in the 2.4 GHz ISM band, self-oscillation detection circuit, and feedback circuit. Based on the theoretical development and simulation, the validity of the proposed structure was confirmed and the manufactured prototype was tested. The board size of the circuit is as small as 65mm × 85㎟, and has a low power consumption of 60mW thanks to the simple RF circuit structure. Finally heartbeat signal has been obtained from a human body moving at low speed (0.5Hz) within a linear distance of 2 to 30mm close to the sensor and a lateral distance of ±20mm.

A study on digital locking device design using detection distance 13.4mm of human body sensing type magnetic field coil (인체 감지형 자기장 코일의 감지거리 13.4mm를 이용한 디지털 잠금장치 설계에 관한 연구)

  • Lee, In-Sang;Song, Je-Ho;Bang, Jun-Ho;Lee, You-Yub
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.9-14
    • /
    • 2016
  • This study evaluated a digital locking device design using detection distance of 13.4mm of a human body sensing type magnetic field coil. In contrast to digital locking devices that are used nowadays, the existing serial number entering buttons, lighting, number cover, corresponding pcb, exterior case, and data delivery cables have been deleted and are only composed of control ON/OFF power switches and emergency terminals. When the magnetic field coil substrates installed inside the inner case detects the electric resistance delivered from the opposite side of the 12mm interval exterior contacting the glass body part, the corresponding induced current flows. At this time, the magnetic field coil takes the role as a sensor when coil frequency of the circular coil is transformed. The magnetic coil as a sensor detects a change in the oscillation frequency output before and after the body is detected. This is then amplified to larger than 2,000%, transformed into digital signals, and delivered to exclusive software to compare and search for embedded data. The detection time followed by the touch area of the body standard to a $12.8{\emptyset}$ magnetic field coil was 30% contrast at 0.08sec and 80% contrast at 0.03sec, in which the detection distance was 13.4mm, showing the best level.

Study of body movement monitoring utilizing nano-composite strain sensors contaning Carbon nanotubes and silicone rubber

  • Azizkhani, Mohammadbagher;Kadkhodapour, Javad;Anaraki, Ali Pourkamali;Hadavand, Behzad Shirkavand;Kolahchi, Reza
    • Steel and Composite Structures
    • /
    • v.35 no.6
    • /
    • pp.779-788
    • /
    • 2020
  • Multi-Walled Carbon nanotubes (MWCNT) coupled with Silicone Rubber (SR) can represent applicable strain sensors with accessible materials, which result in good stretchability and great sensitivity. Employing these materials and given the fact that the combination of these two has been addressed in few studies, this study is trying to represent a low-cost, durable and stretchable strain sensor that can perform excellently in a high number of repeated cycles. Great stability was observed during the cyclic test after 2000 cycles. Ultrahigh sensitivity (GF>1227) along with good extensibility (ε>120%) was observed while testing the sensor at different strain rates and the various number of cycles. Further investigation is dedicated to sensor performance in the detection of human body movements. Not only the sensor performance in detecting the small strains like the vibrations on the throat was tested, but also the larger strains as observed in extension/bending of the muscle joints like knee were monitored and recorded. Bearing in mind the applicability and low-cost features, this sensor may become promising in skin-mountable devices to detect the human body motions.

Center of Pressure of a Human Body using Force Sensing Resistor (Force Sensing Resistor를 이용한 인체압력중심 변화 분석)

  • Park, Cheol;Park, Shinsuk;Kim, Choong Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.12
    • /
    • pp.1722-1725
    • /
    • 2014
  • An experimental investigation of COP(center of pressure) was performed using FSR(force sensing resistor) and force plate. The FSR sensor system is used as effective device to detect the movement of human body in activities of daily living. It has been shown that the FSR provides the trajectories of COP with repeatability and reliability.

Armed person detection using Deep Learning (딥러닝 기반의 무기 소지자 탐지)

  • Kim, Geonuk;Lee, Minhun;Huh, Yoojin;Hwang, Gisu;Oh, Seoung-Jun
    • Journal of Broadcast Engineering
    • /
    • v.23 no.6
    • /
    • pp.780-789
    • /
    • 2018
  • Nowadays, gun crimes occur very frequently not only in public places but in alleyways around the world. In particular, it is essential to detect a person armed by a pistol to prevent those crimes since small guns, such as pistols, are often used for those crimes. Because conventional works for armed person detection have treated an armed person as a single object in an input image, their accuracy is very low. The reason for the low accuracy comes from the fact that the gunman is treated as a single object although the pistol is a relatively much smaller object than the person. To solve this problem, we propose a novel algorithm called APDA(Armed Person Detection Algorithm). APDA detects the armed person using in a post-processing the positions of both wrists and the pistol achieved by the CNN-based human body feature detection model and the pistol detection model, respectively. We show that APDA can provide both 46.3% better recall and 14.04% better precision than SSD-MobileNet.

Development of an Automatic Body Temperature Measuring System for Dairy Cattle (젖소의 자동 체온 측정 시스템 개발)

  • 정길도;김형주;김용준;한병성;김명순
    • Journal of Veterinary Clinics
    • /
    • v.13 no.2
    • /
    • pp.140-143
    • /
    • 1996
  • In this paper the development of an automatic body temperature measuring system which can be attached to the milking machine has been studied. Since the disease is highly related to the body temperature of the cattle, early detection of the abnormal temperature would prevent the severe problems which may occur in dairy farms. The electronic component AD590 is used as a temperature sensor for the system. The device is highly robust against the noise since the output signal is the current. So it can be applied to the long distance sensing. The resolution of the signal is $0.1{\circ}C$ and the current is 10 mV. Also the A/D converter is designed for interfacing the sensor with a computer. A temperature measuring experiment using the developed system has been done for measuring the temperature of human beings and the system was proven to be useful for measuring the body temperature of the dairy cattle properly.

  • PDF

A Study on the Sex Determination of Human Dental Pulp by Y-Chromosome (치수조직염색체에서의 F-body검출에 의한 성별판정에 관한 연구)

  • 박동호;김종열
    • Journal of Oral Medicine and Pain
    • /
    • v.9 no.1
    • /
    • pp.127-138
    • /
    • 1984
  • The author had tried to identify the sex from single tooth by detecting F-body of Y-chromosome in the nucleus of the dental pulp cells of 70 persons aged from 4 to 61 years under a fluorescent miscroscope. The results were as follows : 1. In the cell nuclei of male and female dental pulp at refrigeratory, the rate of F-body appearancd ranged 42-86%(average 61.06%) in male, while it was 0-6%(average 1.86%) in female, indicationg that male could be distinctly differentiated from female by F-body. 2. With male and female dental pulp puterfide by leaving in at room temperature, the rate of F-body appearance ranged 35-58%(average 48.20%) in male, 1-3%(average1.70%) in female, indicating that it was possible to distinguish male and female by F-body. 3. Even in heat-treated male teeth at $100^{\circ}C$,10 mins, the rate of F-body appearace proved to be 32-56%(averaged 42.50%), also indicating the possibility of identifying male. 4. When detecting of F-body in process of time, the rate of F-body appearance did not show major charges. 5. It was reaffirmed that F-body detection method was a positive determination method of male.

  • PDF