• Title/Summary/Keyword: House Planning

Search Result 536, Processing Time 0.025 seconds

A Study on the Time-Sectional Analysis of Apartment Housing related research in Korea (국내 아파트 관련 연구의 연구주제 시계열 분석)

  • Kim, Tae-Sok;Park, Jong-Mo;Park, Eu-Gene;Han, Dong-Suk
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.3
    • /
    • pp.45-52
    • /
    • 2018
  • Currently, apartments have become an important research subject for the overall area of politics, economics, and culture as well as urban architectural study. However, there are few analyses of the research trends related to the current interest in the apartment research and prediction of the future changes of an apartment in politics and industry. In this study, the research information related to the apartment has classified, and the changes in the research trends have analyzed. Based on the classified data, the first thesis and dissertation related to the apartment and changes of academic notation have discovered. In addition, future interests and future research directions through Frequency of Appearance, Degree Centrality Analysis, and Betweenness Centrality Analysis of author keywords were predicted. As a result of the analysis, 'Space,' 'Residential Mobility' and 'Apartment Complex' studies were found to be important research topics throughout the entire period. 'Han Gang Apartment,' 'Small Size Apartment,' 'Civic Apartments,' 'Jamsil,' and 'Child' were newly interested topics until 70's era. '(Super) High-rise Apartment,' 'Perception,' 'Jugong Apartment,' 'Housing Environment,' 'Housewife,' 'Apartment Layout,' and 'Busan' were newly interested topics during the 80's and 90's era. 'Apartment Price,' 'Energy,' 'Remodeling,' 'Noise,' 'Resident Satisfaction,' 'Community,' and 'Apartment Lotting-out' were newly interested topics after the year 2000. New concerns for last decade are found to be 'Super High-rise Apartment', 'Remodeling', 'Indoor'(2007), 'Apartment Reconstruction Project', 'Brand', 'AHP', 'Housing Environment'(2008), 'Ventilation'(2009), 'Apartment Lotting-out'(2010), 'Economic Assessment'(2011), 'Cost'(2012), 'Green Building', 'Apartment Sales', 'Law', 'Society'(2013), 'Floor Impact Noise', 'Seoul'(2014), 'Noise'(2015), 'Hedonic Model'(2016). In addition, following research topics are expected to be active in the future: In maturity stage of the research development is going to be 'Apartment Price', 'Space', 'Management of Apartment Housing'; the hedonic model, which is research growth and development stage, is going to be '(Floor Impact) Noise', 'Community', 'Energy.

A Study on the End of Defects Liability Exit Procedure in Apartment Buildings through Case Studies (사례분석을 통한 공동주택 하자담보책임 종료 절차연구)

  • Kim, Jin-kuk;Bang, Hong-Soon;Choi, Byung-Ju;kim, Ok-Kyue
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.10
    • /
    • pp.25-32
    • /
    • 2018
  • The ending of the warranty under the current Multi-Housing Management Act has a lot of problem as it is very disadvantageous to the business entity and it makes hard for the contractor to finish the repair work. It is almost none for the business entity to get the written confirmation of the expiration of warranty liability from the client even though it sincerely completed their warranty obligation. It is because the client asks for the works other than fair repair arising from the defect in the work, such as the upgrade work for the enhancement of the value of their assets and the repair work which the client should take care before it issues the written confirmation of the expiration of warranty liability to the contractor. "So, though there is the law specifying this matter, the parties are relying on the unnecessary civil agreement. This leads to the big social and economic losses. If there is no agreement made between the client and the contractor, that leads to the legal dispute. This research on cases of 10 apartments shows that the types of works which the apartment residents ask for depend on the characteristics and conditions of the apartments and that they ask for various kinds of compensational works. In addition, it was found that there were many cases in which even the civil agreement is not recognized as the ending of the warranty obligation even if the proper procedure is taken for the ending of warranty by the contractor or business entity. If the collateral is to be offered to the client, the contractor would get more hard because there is the additional cost other than the warranty obligation, thus damaging the legal objective of the laws trying to minimize the damage made to the resident of the apartments. It means that the increase in the unnecessary warranty cost would lead to the increase in the selling price of apartment and the ending of the dispute through the civil procedure would make the Multi-Housing Act ineffective.

Urban Change Detection for High-resolution Satellite Images Using U-Net Based on SPADE (SPADE 기반 U-Net을 이용한 고해상도 위성영상에서의 도시 변화탐지)

  • Song, Changwoo;Wahyu, Wiratama;Jung, Jihun;Hong, Seongjae;Kim, Daehee;Kang, Joohyung
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.6_2
    • /
    • pp.1579-1590
    • /
    • 2020
  • In this paper, spatially-adaptive denormalization (SPADE) based U-Net is proposed to detect changes by using high-resolution satellite images. The proposed network is to preserve spatial information using SPADE. Change detection methods using high-resolution satellite images can be used to resolve various urban problems such as city planning and forecasting. For using pixel-based change detection, which is a conventional method such as Iteratively Reweighted-Multivariate Alteration Detection (IR-MAD), unchanged areas will be detected as changing areas because changes in pixels are sensitive to the state of the environment such as seasonal changes between images. Therefore, in this paper, to precisely detect the changes of the objects that consist of the city in time-series satellite images, the semantic spatial objects that consist of the city are defined, extracted through deep learning based image segmentation, and then analyzed the changes between areas to carry out change detection. The semantic objects for analyzing changes were defined as six classes: building, road, farmland, vinyl house, forest area, and waterside area. Each network model learned with KOMPSAT-3A satellite images performs a change detection for the time-series KOMPSAT-3 satellite images. For objective assessments for change detection, we use F1-score, kappa. We found that the proposed method gives a better performance compared to U-Net and UNet++ by achieving an average F1-score of 0.77, kappa of 77.29.

Evaluation of Metal Volume and Proton Dose Distribution Using MVCT for Head and Neck Proton Treatment Plan (두경부 양성자 치료계획 시 MVCT를 이용한 Metal Volume 평가 및 양성자 선량분포 평가)

  • Seo, Sung Gook;Kwon, Dong Yeol;Park, Se Joon;Park, Yong Chul;Choi, Byung Ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.25-32
    • /
    • 2019
  • Purpose: The size, shape, and volume of prosthetic appliance depend on the metal artifacts resulting from dental implant during head and neck treatment with radiation. This reduced the accuracy of contouring targets and surrounding normal tissues in radiation treatment plan. Therefore, the purpose of this study is to obtain the images of metal representing the size of tooth through MVCT, SMART-MAR CT and KVCT, evaluate the volumes, apply them into the proton therapy plan, and analyze the difference of dose distribution. Materials and Methods : Metal A ($0.5{\times}0.5{\times}0.5cm$), Metal B ($1{\times}1{\times}1cm$), and Metal C ($1{\times}2{\times}1cm$) similar in size to inlay, crown, and bridge taking the treatments used at the dentist's into account were made with Cerrobend ($9.64g/cm^3$). Metal was placed into the In House Head & Neck Phantom and by using CT Simulator (Discovery CT 590RT, GE, USA) the images of KVCT and SMART-MAR were obtained with slice thickness 1.25 mm. The images of MVCT were obtained in the same way with $RADIXACT^{(R)}$ Series (Accuracy $Precision^{(R)}$, USA). The images of metal obtained through MVCT, SMART-MAR CT, and KVCT were compared in both size of axis X, Y, and Z and volume based on the Autocontour Thresholds Raw Values from the computerized treatment planning equipment Pinnacle (Ver 9.10, Philips, Palo Alto, USA). The proton treatment plan (Ray station 5.1, RaySearch, USA) was set by fusing the contour of metal B ($1{\times}1{\times}1cm$) obtained from the above experiment by each CT into KVCT in order to compare the difference of dose distribution. Result: Referencing the actual sizes, it was appeared: Metal A (MVCT: 1.0 times, SMART-MAR CT: 1.84 times, and KVCT: 1.92 times), Metal B (MVCT: 1.02 times, SMART-MAR CT: 1.47 times, and KVCT: 1.82 times), and Metal C (MVCT: 1.0 times, SMART-MAR CT: 1.46 times, and KVCT: 1.66 times). MVCT was measured most similarly to the actual metal volume. As a result of measurement by applying the volume of metal B into proton treatment plan, the dose of $D_{99%}$ volume was measured as: MVCT: 3094 CcGE, SMART-MAR CT: 2902 CcGE, and KVCT: 2880 CcGE, against the reference 3082 CcGE Conclusion: Overall volume and axes X and Z were most identical to the actual sizes in MVCT and axis Y, which is in the superior-Inferior direction, was regular in length without differences in CT. The best dose distribution was shown in MVCT having similar size, shape, and volume of metal when treating head and neck protons. Thus it is thought that it would be very useful if the contour of prosthetic appliance using MVCT is applied into KVCT for proton treatment plan.

Efficacy and Accuracy of Patient Specific Customize Bolus Using a 3-Dimensional Printer for Electron Beam Therapy (전자선 빔 치료 시 삼차원프린터를 이용하여 제작한 환자맞춤형 볼루스의 유용성 및 선량 정확도 평가)

  • Choi, Woo Keun;Chun, Jun Chul;Ju, Sang Gyu;Min, Byung Jun;Park, Su Yeon;Nam, Hee Rim;Hong, Chae-Seon;Kim, MinKyu;Koo, Bum Yong;Lim, Do Hoon
    • Progress in Medical Physics
    • /
    • v.27 no.2
    • /
    • pp.64-71
    • /
    • 2016
  • We develop a manufacture procedure for the production of a patient specific customized bolus (PSCB) using a 3D printer (3DP). The dosimetric accuracy of the 3D-PSCB is evaluated for electron beam therapy. In order to cover the required planning target volume (PTV), we select the proper electron beam energy and the field size through initial dose calculation using a treatment planning system. The PSCB is delineated based on the initial dose distribution. The dose calculation is repeated after applying the PSCB. We iteratively fine-tune the PSCB shape until the plan quality is sufficient to meet the required clinical criteria. Then the contour data of the PSCB is transferred to an in-house conversion software through the DICOMRT protocol. This contour data is converted into the 3DP data format, STereoLithography data format and then printed using a 3DP. Two virtual patients, having concave and convex shapes, were generated with a virtual PTV and an organ at risk (OAR). Then, two corresponding electron treatment plans with and without a PSCB were generated to evaluate the dosimetric effect of the PSCB. The dosimetric characteristics and dose volume histograms for the PTV and OAR are compared in both plans. Film dosimetry is performed to verify the dosimetric accuracy of the 3D-PSCB. The calculated planar dose distribution is compared to that measured using film dosimetry taken from the beam central axis. We compare the percent depth dose curve and gamma analysis (the dose difference is 3%, and the distance to agreement is 3 mm) results. No significant difference in the PTV dose is observed in the plan with the PSCB compared to that without the PSCB. The maximum, minimum, and mean doses of the OAR in the plan with the PSCB were significantly reduced by 9.7%, 36.6%, and 28.3%, respectively, compared to those in the plan without the PSCB. By applying the PSCB, the OAR volumes receiving 90% and 80% of the prescribed dose were reduced from $14.40cm^3$ to $0.1cm^3$ and from $42.6cm^3$ to $3.7cm^3$, respectively, in comparison to that without using the PSCB. The gamma pass rates of the concave and convex plans were 95% and 98%, respectively. A new procedure of the fabrication of a PSCB is developed using a 3DP. We confirm the usefulness and dosimetric accuracy of the 3D-PSCB for the clinical use. Thus, rapidly advancing 3DP technology is able to ease and expand clinical implementation of the PSCB.

Ecological Niche of Quercus acutissima and Quercus variabilis (상수리나무와 굴참나무의 생태적 지위에 관한 연구)

  • Kim, Hae-Ran;Jeong, Heon-Mo;Kim, Hyea-Ju;You, Young-Han
    • Korean Journal of Environmental Biology
    • /
    • v.26 no.4
    • /
    • pp.385-391
    • /
    • 2008
  • In Korea, Quercus acutissima distributed in good condition with high nutrients and moisture content, but Quercus variabilis in dry soil or rock habitate. In order to understand this ecological distribution of Q. acutissima and Q. variabilis, we cultivated the seedlings of two oak species treated with light, soil moisture and nutrient gradients each four level, from May to October in glass house. Then we measured the ecological niche breadth and niche overlap of the two species, and analyzed the relationship of competition using cluster analysis and PCA ordination. Ecological niche breadths of Q. acutissima under moisture and nutrient treatments were slightly wider than those under light one. Among 14 characters measured, 6 characters related with length items were wider in all the environmental treatments, but 8 characters connected with weight terms narrower in light treatment. Ecological niche breadths of Q. variabilis under moisture and nutrient treatment were wider than those of light one. Ecological niche of Q. acutissima was wider than those of Q. variabilis in all the environmental treatments. Ecological overlap between two species was higher with a range of 0.87$\sim$0.92, especially higher in soil moisture factor. These results means that Q. acutissima is more competitive than Q. variabilis, especially in soil moisture condition. Two species were ordinated with distinct group based on 9 characters. From these results, it can be explained that what Q. variabilis distributed in bad soil condition is due to the escape strategy, because of its low competitive ability to Q. acutissima in natural communities.

Clinical Application of Dose Reconstruction Based on Full-Scope Monte Carlo Calculations: Composite Dose Reconstruction on a Deformed Phantom (몬테칼로 계산을 통한 흡수선량 재구성의 임상적 응용: 변형된 팬텀에서의 총제적 선량재구성)

  • Yeo, Inhwan;Xu, Qianyi;Chen, Yan;Jung, Jae Won;Kim, Jong Oh
    • Progress in Medical Physics
    • /
    • v.25 no.3
    • /
    • pp.139-142
    • /
    • 2014
  • The purpose of this study was to develop a system of clinical application of reconstructed dose that includes dose reconstruction, reconstructed dose registration between fractions of treatment, and dose-volume-histogram generation and to demonstrate the system on a deformable prostate phantom. To achieve this purpose, a deformable prostate phantom was embedded into a 20 cm-deep and 40 cm-wide water phantom. The phantom was CT scanned and the anatomical models of prostate, seminal vesicles, and rectum were contoured. A coplanar 4-field intensity modulated radiation therapy (IMRT) plan was used for this study. Organ deformation was simulated by inserting a "transrectal" balloon containing 20 ml of water. A new CT scan was obtained and the deformed structures were contoured. Dose responses in phantoms and electronic portal imaging device (EPID) were calculated by using the XVMC Monte Carlo code. The IMRT plan was delivered to the two phantoms and integrated EPID images were respectively acquired. Dose reconstruction was performed on these images using the calculated responses. The deformed phantom was registered to the original phantom using an in-house developed software based on the Demons algorithm. The transfer matrix for each voxel was obtained and used to correlate the two sets of the reconstructed dose to generate a cumulative reconstructed dose on the original phantom. Forwardly calculated planning dose in the original phantom was compared to the cumulative reconstructed dose from EPID in the original phantom. The prescribed 200 cGy isodose lines showed little difference with respect to the "prostate" and "seminal vesicles", but appreciable difference (3%) was observed at the dose level greater than 210 cGy. In the rectum, the reconstructed dose showed lower volume coverage by a few percent than the plan dose in the dose range of 150 to 200 cGy. Through this study, the system of clinical application of reconstructed dose was successfully developed and demonstrated. The organ deformation simulated in this study resulted in small but observable dose changes in the target and critical structure.

Effect of Pig Slurry Fertigation on Soil Chemical Properties and Growth and Development of Cucumber (Cucumis sativus L.) (돈분 액비 관비가 오이의 생육 및 토양화학성에 미치는 영향)

  • Park, Jin-Myeon;Lim, Tae-Jun;Lee, Seong-Eun;Lee, In-Bok
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.2
    • /
    • pp.194-199
    • /
    • 2011
  • This study was conducted to evaluate fertigation effects of pig slurry (PS) and chemical fertilizer (CF) in cucumber by investigating the growth and yield, nutrient content and uptake, nutrient use efficiency, and soil characteristics in greenhouse cultivation. The cropping patterns of cucumber were semi-forcing culture and retarding culture, and the experiment involves four treatments: No fertilizer (NF), $26mg\;L^{-1}$ and $52mg\;L^{-1}$ of N application by slurry composting biofiltration liquefied fertilizer (SCBLF), and $52mg\;L^{-1}$ of N treatment by chemical fertilizer. The difference on the plant height of cucumber between SCBLF and CF treatments was no significant, but fresh weight and dry weight of stem and root were higher in $26mg\;L^{-1}$ SCBLF treatment. The Ca content of the leaf was lower in the treatments of SCBLF and the K content of the root was lower in the $52mg\;L^{-1}$ CF treatment. The Ca content of the stem was lowest in the $52mg\;L^{-1}$ CF treatment and the mineral content of the fruit showed no significant difference. In case of semi-forcing culture, the gross yield was lower in the $52mg\;L^{-1}$ CF treatment and the yield of unmarketable fruit was lower in the SCBLF treatments. The nutrient use efficiency of cucumber is as follows: K (8.3 ~ 30.9%), N (4.2 ~ 13.0%), P (1.9 ~ 2.0%). The SCBLF treatments showed higher figure in the soil pH than that of the CF treatment, while EC and the content of $NO_3$-N were higher in the CF treatment than the former. The content of exchangeable K was higher in the plot treated with $52mg\;L^{-1}$ SCBLF, and there were no significant differences in the content of Ca and Mg between the treatments. In conclusion, it is suggested that the application of liquefied manure made from pig slurry may be able to replace the use of chemical fertilizer in nitrogen and potassium.

A Study on Performance and Achievement of Village Health Workers in Rural Primary Health Care Program (농촌 일차 보건사업에 있어서 마을건강원 업무량 및 업적에 관한 연구)

  • Hur, Dal-Young;Lee, Myoung-Sook;Yum, Yong-Tae;Kim, Soon-Duck
    • Journal of agricultural medicine and community health
    • /
    • v.12 no.1
    • /
    • pp.36-53
    • /
    • 1987
  • It is utmostly important to establish the efficient fitable way of peoples' active participation in primary health care especially in the areas where the public or governmental service input for the basic health care is insufficient like as in rural areas of Korea. In light of above reason, this study focused mainly on the evaluation of roles and activities of village health workers (VHWs) who were selected from grass- root level of village people in order to derive further motivation for active participation. This is believed to be a sort of feedback mechanisms. Actually, the authors collected the activity reports of VHWs who had been devoting themselves in the primary health care services of Jeomdong Area, of Yeoju Gun one of Korea University Community Health Action Programmes and survey record on the VHWs activity from correspondent people. 1 hose data were analyzed through computer programmed package. The activities performed by VHWs were limited to the performance in 1985 for conveniance. The summarized results were as follows; 1) General characteristics of VHWs. Among a total of 28 VHWs in the area, about 39.3g of them have been replaced up to the date since the implementation in 1983, because of moving out, occupational employment and of others. The age of majority (75.0%) lied between the range of 30-50, and educational background of 67.9% belonged to category of primary school graduation, about 50% of them experienced to be or were also entiled "chief of women club" of corresponding villages. 2) Work-load of VHWs. Each VHW was assigned for tasks of health care for average 55 households of 248 persons. They shared approximately 6 days a month for the activity in average and it covered 17 cases of basic health care in a month. A half of the VHWs performed home visits irregularly without solidified schedule. 3) Work performance analysis. Informations collected through VHWs were compared with data from official vital registration at local administration center "Myon Office" in 1985. VHWs collected 100.8 of new born, 116.2 of death, 58.3 of move in and 74.8 of move out in comparison with 100.0 of official registration each. Pregnant women of 79.8% of mothers among the total pregnancy of 94 which were confirmed as normally delivered or aborted cases by all means afterwards had been detected by VHWs as being pregnant and all of them received some of antenatal cares by VHWs. All(100%) of delivered women were detected by VHWs through home visits and they were cared postnatally. Whereas, according to the records of birth registration, the places of delivery were clinic in 33.7%, and mother's home in 66.3%, VHWs reported them to be clinic in 48.9%, midwifery in 20.2%. It was cleared that most of misinformation was caused by uncautious filling of birth registration at notification. Among the total of 717 eligible women under age 44 years, family planning status of 92.6% was reported by VHWs confirming practice of control to be 70.8% of reported fertile women. 4) Attitude of VHW on the roles and functions. Although 92.0% of VHWs expressed VHWs to be worthwhile, only 52.0% of them had dignity and satisfaction in their activity and 44.0% of them had passive attitude of working saying they followed direction regardlessly. Concerning difficulties in performance as a VHW, 60.7% of them pointed out lacking of medical and health related knowledge by themselves. Still, 64.0% of them thought visiting unfamilier house to be awful and 40.0% complained forms of activity to be difficult and hard. It was also revealed that 56.6% confessed lack of interest on community health service itself. Most of VHWs needed more educational training especially on clinical fields such as cares of gynecological diseases, hypertension, diabetes, and other chronic diseaes of the aged. Regular on-the-job basic trainings were said to be needed twice a year.

  • PDF

Development of Video Image-Guided Setup (VIGS) System for Tomotherapy: Preliminary Study (단층치료용 비디오 영상기반 셋업 장치의 개발: 예비연구)

  • Kim, Jin Sung;Ju, Sang Gyu;Hong, Chae Seon;Jeong, Jaewon;Son, Kihong;Shin, Jung Suk;Shin, Eunheak;Ahn, Sung Hwan;Han, Youngyih;Choi, Doo Ho
    • Progress in Medical Physics
    • /
    • v.24 no.2
    • /
    • pp.85-91
    • /
    • 2013
  • At present, megavoltage computed tomography (MVCT) is the only method used to correct the position of tomotherapy patients. MVCT produces extra radiation, in addition to the radiation used for treatment, and repositioning also takes up much of the total treatment time. To address these issues, we suggest the use of a video image-guided setup (VIGS) system for correcting the position of tomotherapy patients. We developed an in-house program to correct the exact position of patients using two orthogonal images obtained from two video cameras installed at $90^{\circ}$ and fastened inside the tomotherapy gantry. The system is programmed to make automatic registration possible with the use of edge detection of the user-defined region of interest (ROI). A head-and-neck patient is then simulated using a humanoid phantom. After taking the computed tomography (CT) image, tomotherapy planning is performed. To mimic a clinical treatment course, we used an immobilization device to position the phantom on the tomotherapy couch and, using MVCT, corrected its position to match the one captured when the treatment was planned. Video images of the corrected position were used as reference images for the VIGS system. First, the position was repeatedly corrected 10 times using MVCT, and based on the saved reference video image, the patient position was then corrected 10 times using the VIGS method. Thereafter, the results of the two correction methods were compared. The results demonstrated that patient positioning using a video-imaging method ($41.7{\pm}11.2$ seconds) significantly reduces the overall time of the MVCT method ($420{\pm}6$ seconds) (p<0.05). However, there was no meaningful difference in accuracy between the two methods (x=0.11 mm, y=0.27 mm, z=0.58 mm, p>0.05). Because VIGS provides a more accurate result and reduces the required time, compared with the MVCT method, it is expected to manage the overall tomotherapy treatment process more efficiently.