Background: Persistent uroliths after a cystotomy in dogs are a common cause of surgical failure. Objectives: This study examined the following: the success rate of retrograde urohydropropulsion in male dogs using non-enhanced computed tomography (CT), whether the CT mean beam attenuation values in Hounsfield Units (mHU) measured in vivo could predict the urolithiasis composition and whether the selected reconstruction kernel may influence the measured mHU. Methods: All dogs and cats that presented with lower urinary tract uroliths and had a non-enhanced CT preceding surgery were included. In male dogs, CT was performed after retrograde urohydropropulsion to detect the remaining urethral calculi. The percentage and location of persistent calculi were recorded. The images were reconstructed using three kernels, from smooth to ultrasharp, and the calculi mHU were measured. Results: Sixty-five patients were included in the study. The success rate of retrograde urohydropropulsion in the 45 male dogs was 55.6% and 86.7% at the first and second attempts, respectively. The predominant components of the calculi were cystine (20), struvite (15), calcium oxalate (8), and urate (7). The convolution kernel influenced the mHU values (p < 0.05). The difference in mHU regarding the calculus composition was better assessed using the smoother kernel. A mHU greater than 1,000 HU was predictive of calcium oxalate calculi. Conclusions: Non-enhanced CT is useful for controlling the success of retrograde urohydropropulsion. The mHU could allow a prediction of the calculus composition, particularly for calcium oxalate, which may help determine the therapeutic strategy.
Lipomatosis is a condition containing multiple lipomatous masses.Lipoma is a benign neoplasm composed of adult adipose tissue, and occur most often in the fifth or sixth decade and rarely in the pleura. Pleural lipomas are usually asymptomatic and revealed as an incidental roentgenographic findings. The patient was 59 year-old male and admitted because of dyspnea-on-exertion for 30 years. Chest CT revealed right pleural mass abutting on the chest wall, measuring minus 80 hounsfield units. The mass was resected with calcified pleural plaque and confirmed to be lipomatosis with collagenous fibrosis arising from viserai pleura.
A 5-year-old intact female Persian cat was referred with anorexia and vomiting. Physical examination revealed icterus in the pinna, oral mucosa, and sclera. Ultrasonography revealed several findings including uniformly hyperechoic hepatic parenchyma compared to adjacent falciform fat, increased attenuation of the ultrasound beam, and poor visualization of intrahepatic vessel borders. Computed tomography revealed hypoattenuation of the hepatic parenchyma with a radiodensity value of -60 Hounsfield units. The adjacent intrahepatic vessels appeared hyperattenuated relative to the hepatic parenchyma as if the vessels were contrast-enhanced. Based on ultrasonography and computed tomography results, the cat was tentatively diagnosed as feline hepatic lipidosis.
This paper describes the computed tomographic features of ovarian masses in dogs. The CT images of female dogs with a confirmed histological diagnosis of ovarian tumors or ovarian cystic diseases were studied retrospectively. Seven dogs met the inclusion criteria. The morphological features of ovarian tumors and ovarian cystic diseases coincided to a certain degree, but ovarian tumors tended to be predominantly solid. Objective measurements of Hounsfield units (HU) suggest that benign lesions may show lower HU values than malignant tumors and mild contrast enhancement because of the small soft tissue composition. CT is useful for a differential diagnosis of ovarian masses by providing additional information on the imaging features of the masses and an evaluation of metastases.
본 연구는 CT 촬영 시 금속으로 인해 발생한 금속 인공물 감소를 위한 알고리즘 적용에 따른 영상 화질에 대한 정량적 비교를 하고자 한다. Spectral detected-based CT와 CT ACR 464 팬톰을 이용하여 일반적인 필터보정역투영 알고리즘을 적용한 기준 영상을 10장 획득하고, 동일 팬톰에 금속 인공물을 발생시켜 일반적인 필터보정역투영 알고리즘을 적용한 영상을 10장 획득하였다. 금속 인공물을 발생시켜 획득한 영상의 원시 데이터에 metal artifact reduction 알고리즘, 가상 단일 에너지 알고리즘, metal artifact reduction 알고리즘 적용 후 추가로 가상 단일 에너지 알고리즘을 적용한 영상을 각각 10장씩 획득하였다. 알고리즘 적용에 따른 hounsfield unit 비교를 위해 CT ACR 464 팬톰 module 1에 위치한 폴리에틸렌, 뼈, 아크릴, 공기, 물에 관심영역을 설정하고, 전체 영상 화질 평가를 위해 평균 제곱근 오차, 평균 절대 오차, 신호 대 잡음비, 최대 신호 대 잡음비, 구조적 유사도 지수 지표를 통해 알고리즘 별 비교하였다. 알고리즘 적용 영상 별 hounsfield unit 비교 결과 알고리즘 적용 영상 간 유의한 차이를 보였으며(p < .05), 아크릴을 제외한 관심영역에서 가상 단일 에너지 알고리즘 적용 영상에서 큰 변화를 나타냈다. 영상 화질 평가 지표 결과 metal artifact reduction 알고리즘 적용 영상 화질이 가장 높았으나, 구조적 유사도 지수는 metal artifact reduction 알고리즘 적용 후 추가로 가상 단일 에너지 알고리즘이 동시에 적용된 영상이 가장 높았다. CT 촬영 시 금속 인공물 감소에 metal artifact reduction 알고리즘이 가상 단일 에너지 알고리즘에 비해 효과적이었지만, 양질의 CT 영상 획득을 위해 알고리즘 적용에 따른 이점과 영상 화질 변화를 파악하고 효율적인 활용이 필요하다고 사료된다.
This study was performed to differentiate calcium oxalate and struvite canine urinary stones using computed tomography. A total of 38 urinary stones (8 calcium oxalate and 30 struvite) were scanned using a computed tomography scanner. These urinary stones (10-15 mm diameter) extracted surgically without fragmentation were obtained from the different individual patients. The stone's Hounsfield units(HU) values, heterogenicity, and roughness of surface were evaluated to differentiate calcium oxalate and struvite. The HU values of calcium oxalate were significantly higher than those of struvite. A receiver operator characteristic (ROC) curve revealed 1272 as the best threshold value to distinguish calcium oxalate from struvite (ROC curve AUC 0.87, p < 0.0014). The heterogenicity of calcium oxalate and struvite significantly differed on bone and dental window setting (p < 0.0001). There was no significant difference between calcium oxalate and struvite in roughness of surface. On computed tomographic images, bone and dental windows setting were useful for evaluation of heterogenicity between calcium oxalate and struvite. The HU value and heterogenicity are highly promising factor that can distinguish calcium oxalate and struvite with reasonable accuracy.
CT검사에 따른 방사선 선량의 유해성에 대한 관심이 고조되고 있어, 고정관전류기법과 AEC(automatic exposure control)를 적용하여 선량의 감소 효과를 비교하였다. 64MDCT를 이용하여 인체조직등가물질 팬텀으로 흉부 및 복부 부위를 고정관전류기법과 AEC를 적용하여 CTDIvol과 DLP를 비교하였고, 영상의 평가는 관심영역으로 CT감약계수와 노이즈를 측정하여 비교하였다. 흉부에서 고정관전류기법과 AEC적용에 따른 선량감소 효과는 CTDIvol 35.2%, DLP 49.3%, 복부에서는 CTDIvol 5.9%, DLP 3.2% 감소 효과가 있었다. CT검사에서 자동노출장치인 AEC를 이용하여 선량의 감소효과가 있다. CT 검사에 따른 환자의 피폭선량을 줄이기 위해서는 AEC를 이용하여야 한다.
Purpose: The microstructural characteristics of trabecular bone were identified using micro-computed tomography (micro-CT), in order to develop a potential strategy for implant surface improvement to facilitate osseointegration. Methods: Alveolar bone specimens from the cadavers of 30 humans were scanned by high-resolution micro-CT and reconstructed. Volumes of interest chosen within the jaw were classified according to Hounsfield units into 4 bone quality categories. Several structural parameters were measured and statistically analyzed. Results: Alveolar bone specimens with D1 bone quality had significantly higher values for all structural parameters than the other bone quality categories, except for trabecular thickness (Tb.Th). The percentage of bone volume, trabecular separation (Tb.Sp), and trabecular number (Tb.N) varied significantly among bone quality categories. Tb.Sp varied markedly across the bone quality categories (D1: $0.59{\pm}0.22mm$, D4: $1.20{\pm}0.48mm$), whereas Tb.Th had similar values (D1: $0.30{\pm}0.08mm$, D4: $0.22{\pm}0.05mm$). Conclusions: Bone quality depended on Tb.Sp and number-that is, endosteal space architecture-rather than bone surface and Tb.Th. Regardless of bone quality, Tb.Th showed little variation. These factors should be taken into account when developing individualized implant surface topographies.
The purpose of this study was to evaluate the clinical and imaging characteristics of canine splenic tumors and to establish guidelines for the presurgical assessment of splenic tumors in dogs. Fifty-seven dogs that underwent total splenectomy for the treatment of splenic tumors were evaluated by examining medical records, hematologic results, diagnostic imaging results, and histopathologic results. The maximum lesion size from ultrasonography was significantly different between malignant and benign tumors (p = 0.002). There was a correlation between tumor margination and type of splenic tumors (p = 0.045). Precontrast lesion attenuation on computed tomography was significantly different between splenic malignant and benign tumors (p = 0.001). The mean ${\pm}$ SD precontrast lesion attenuation of malignant tumors was $40.3{\pm}5.9$ Hounsfield units (HU), and for benign tumors, it was $52.8{\pm}6.8HU$. In conclusion, some variables of the imaging examination could be used to distinguish the type of splenic tumor. Based on the study results, using a diagnostic flowchart would be effective in increasing the survival rate of patients with splenic malignant tumors. In addition, fine needle aspiration or magnetic resonance imaging prior to surgical exploration and histopathologic examination may be useful in achieving a more accurate diagnosis.
Purpose: Focused ultrasound is an emerging technology for treating the brain locally in a noninvasive manner. In this study, we have investigated the influence of skull properties on simulating transcranial pressure field. Methods: A 3D computational model of transcranial focused ultrasound was constructed using female and male CT data to solve for intracranial pressure. For heterogeneous model, the acoustic properties were calculated from CT Hounsfield units based on a porosity. The homogeneous model assigned constant acoustic properties for the single-layered skull. Results: A computational model was validated against empirical data. The homogeneous models were then compared with the heterogeneous model, resulted in 10.87% and 7.19% differences in peak pressure for female and male models respectively. For the focal volume, homogeneous model demonstrated more than 94% overlap compared with the heterogeneous model. Conclusion: Homogeneous model can be constructed using MR images that are commonly used for the segmentation of the skull. We propose the possibility of the homogeneous model for the simulating transcranial pressure field owing to comparable focal volume between homogeneous model and heterogeneous model.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.