• Title/Summary/Keyword: Hounsfield unit

Search Result 118, Processing Time 0.023 seconds

Distinction of Internal Tissue of Raw Ginseng Root Using a Computed Tomography Scanner

  • Jung, In-Chan;Jeong, In-Soo;Kim, Cheon-Suk
    • Journal of Ginseng Research
    • /
    • v.36 no.4
    • /
    • pp.469-476
    • /
    • 2012
  • Raw ginseng root of Panax ginseng is graded according to its shape and the quality of its internal tissue. A variety of grades are sold with prices according to grade. If an inferior raw ginseng is purchased, the consumer experience an economic loss. This research was conducted in order to explore the possibility of developing a noninvasive method for investigating raw ginseng's internal tissue. It has been determined that computed tomography (CT) scanner images agreed with actual cross-sections of raw ginseng. CT images were obtained to assess the internal portions of raw ginseng, and CT scans of raw ginseng were thoroughly measured using the Hounsfield unit (HU) system, since it allows for a more detailed analysis compared to nuclear magnetic resonance imaging. HU is a measure of attenuation used for CT images, with each pixel being assigned a value using a scale on which air is defined as -1000, water as 0 and compact bone as +1000. It takes about one second to process are slice and produce an image of the raw ginseng by a one channel CT scanner. An image good enough to discriminate the internal tissues can be obtained in 1/24 seconds with a one-channel CT scanner. Using this method, images of raw ginseng can be obtained and the characteristics of the internal tissues can be observed in a short time.

Effects of Physical Factors on Computed Tomography Image Quality

  • Jeon, Min-Cheol;Han, Man-Seok;Jang, Jae-Uk;Kim, Dong-Young
    • Journal of Magnetics
    • /
    • v.22 no.2
    • /
    • pp.227-233
    • /
    • 2017
  • The purpose of this study was to evaluate the effects of X-ray photon energy, tissue density, and the kernel essential for image reconstruction on the image quality by measuring HU and noise. Images were obtained by scanning the RMI density phantom within the CT device, and HU and noise were measured as follows: images were obtained by varying the tube voltages, the tube currents and eight different kernels. The greater the voltage-dependent change in the HU value but the noise was decreased. At all densities, changes in the tube current did not exert any significant influence on the HU value, whereas the noise value gradually decreased as the tube current increased. At all densities, changes in the kernel did not exert any significant influence on the HU value. The noise value gradually increased in the lower kernel range, but rapidly increased in the higher kernel range. HU is influenced by voltage and density, and noise is influenced by voltage, current, kernel, and density. This affects contrast resolution and spatial resolution.

A Solid Anterior Mediastinal Mass (전종격동 고형성 종괴)

  • You, Young-Kyu;Ahn, Young-Soo;Rha, Dong-Jib;Kim, Do-Jin;Lee, Sang-Moo;Kim, Hyeon-Tae;Uh, Soo-Taek;Kim, Yong-Hoon;Park, Choon-Sik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.6
    • /
    • pp.747-750
    • /
    • 1993
  • A 51-year-old male was admitted due to mediastinal mass. Chest PA showed a $4{\times}5$ cm sized round mass on right lower paratracheal area. The chest computerized tomogram showed cystic mass located between superior vena cava and trachea. This cystic mass was composed of variable internal architecture with Hounsfield unit(HU) from -44.4 to +25.5. The resected cystic mass revealed ectodermal, mesodermal, and endodermal structures. We report a case of anterior mediastinal cystic teratoma confirmed by open thoracotomy.

  • PDF

The Effect of Advanced Modeling Iterative Reconstruction(ADMIRE) on the Quality of CT Images : Non-contrast CT in Chest (고급 모델링 반복 재구성법(ADMIRE)이 CT 영상의 화질에 미 치는 영향: 흉부 비조영 CT에서)

  • Lee, SangHeon;Lee, HyoYeong
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.159-168
    • /
    • 2019
  • We examined the effect of Siemens ADMIRE (Advanced Modeled Iterative Reconstruction) on image quality by measuring changes in HU, noise, and SNR of background air, fat, muscle, and background signals on a chest CT scan. Experimental results show that as the ADMIRE Strength increases, the noise decreases and the signal increases, consequently the signal-to-noise ratio increases. ADMIRE can reduce noise by 28 ~ 61% compared to FBP, which is a conventional image reconstruction algorithm, and improves SNR by 16 ~ 100%.

Estimation of Lower Jaw Density using CT data

  • Jargalsaikhan, Ariunbold;Sengee, Nyamlkhagva;Telue, Berekjan;Ochirkhvv, Sambuu
    • Journal of Multimedia Information System
    • /
    • v.6 no.2
    • /
    • pp.67-74
    • /
    • 2019
  • Bone density is one of the factors in the early failure of dental implants and doctors should make a preoperative assessment of jaw bone density using patient's CT data before dental implant surgery in order to find out whether the patient has osteoporosis and osteopenia. The main goal of this study was to propose a method that based on image processing techniques in order to provide accurate information about where to drill and place an abutment screw of implants in the jaw bone for doctors and reduce human activity for the estimation of the local cancellous bone density of mandible using CT data. The experiment was performed on a computed tomography data of the jaw bone of two different individuals. We assumed that the result of the estimation of jaw bone density depends on the angle of drilling and average HU (Hounsfield Unit) values were used to evaluate the quality of local cancellous bone density of mandible. As a result of this study, we have been developed a toolbox that can be used to estimate jaw bone density automatically and found a positive correlation between the angle of the drill and time complexity but a negative correlation between the diameter of the drill and time complexity.

The Osteoporotic Condition as a Predictive Factor for Hemorrhagic Transformation in Acute Cardioembolic Stroke

  • Won, Yu Deok;Kim, Jae-Min;Ryu, Je-Il;Koh, Seong-Ho;Han, Myung-Hoon;Cheong, Jin-Hwan
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.5
    • /
    • pp.763-775
    • /
    • 2021
  • Objective : Hemorrhagic transformation (HT) can be occurred after acute cerebral infarction. HT can worse symptoms in severe cases and adversely affect long-term prognosis. As bone and vascular smooth muscle are composed of type 1 collagen, we aimed to identify a potential relationship between bone mineral density (BMD) and HT after acute cardioembolic stroke. Methods : As an indicator of BMD, we used mean frontal skull Hounsfield unit (HU) values on brain computed tomography (CT). Multivariative hazard ratios were calculated using Cox regression analysis to identify whether the osteoporotic condition was an independent predictor of HT after acute cardioembolic stroke. Results : This 11-year analysis enrolled 506 patients who diagnosed as acute cardioembolic infarction. The first tertile of skull HU value was an independent predictor of HT development compared to the third tertile (hazard ratio, 2.12; 95% confidence interval, 1.13-3.98; p=0.020). We observed no interactions between age and skull HU with respect to HT statistically. Conclusion : The results of this study revealed an association between osteoporotic conditions and HT development after acute cardioembolic stroke. A convenient method to measure the cancellous bone HU value of the frontal skull using brain CT images may be useful for predicting HT in patients with acute cerebral infarction.

CT Evaluation of Age-Related Changes in Epaxial Muscle Attenuation and Cross-Sectional Area for Sarcopenia and Myosteatosis in Small Breed Dogs

  • Ji Yeong Lee;Tae Sung Hwang;Hee Chun Lee
    • Journal of Veterinary Clinics
    • /
    • v.40 no.3
    • /
    • pp.182-188
    • /
    • 2023
  • Sarcopenia and myosteatosis can increase the risk of adverse effects in dogs and humans. However, such imaging study results for evaluating sarcopenia and myosteatosis in small dogs have not yet been available. The objective of this study was to assess age-related changes according to the breed in epaxial muscle cross-sectional area (CSA) and fat infiltration using CT to evaluate sarcopenia and age-related myosteatosis in small breed dogs. In 144 dogs (92 Maltese dogs, 27 Poodle dogs, and 25 Shih Tzu dogs), Hounsfield Unit (HU) values and CSA of left epaxial muscle were measured at the thirteenth thoracic vertebral level on non-contrast transverse CT images. Differences in HU values and CSA according to age and breed were analyzed. The geriatric group (≥12 years) had significantly lower HU values of epaxial muscle than mature adult group (2 to 6 years) of all breeds. The geriatric group had significantly lower CSA of epaxial muscle than mature adult and senior groups (7 to 11 years) of Maltese dogs. HU values of epaxial muscle were not significantly different among all age groups of all breeds. Maltese dogs had significantly lower CSA of epaxial muscle than Poodle and Shih Tzu dogs in all age groups. Results of this study showed that as age increased in small breed dogs, muscle mass and density decreased.

조영제 사용 전${\cdot}$후 불균질 조직 보정 알고리즘에 따른 선량변화에 대한 연구

  • Kim, Ju-Ho;Jo, Jeong-Hui;Lee, Seok;Jeon, Byeong-Cheol;Park, Jae-Il
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.13 no.1
    • /
    • pp.38-46
    • /
    • 2001
  • Purpose : The aim of this study is to investigate the effect of tissue inhomogeneities when appling to contrast medium among Homogeneous, Batho and ETAR dose calculation method in RTP system. Method and Material : We made customized heterogeneous phantom it filled with water or contrast medium slab. Phantom scan data have taken PQ 5000 (CT scanner, Marconi, USA) and then dose was calculated in 3D RTP (AcQ-Plan, Marconi, USA) depends on dose calculation algorithm (Homogeneous, Batho, ETAR). The dose comparisons were described in terms of 2D isodose distribution, percent depth dose data, effective path length and monitor unit. Also dose distributions were calculated with homogeneous and inhomogeneous correction algorithm, Batho and ETAR, in each patients with different clinical sites. Results : Result indicated that Batho and ETAR method gave rise to percent depth dose deviation $1.5{\sim}2.7\%,\;2.3{\sim}3.5\%$ (6MV, field size $10{\times}10cm^2$) in each status with and without contrast medium. Also show that effective path lengths were more increase in contrast status (23.14 cm) than Non-contrast (22.07 cm) about $4.9\%$ or 10.7 mm (In case Hounsfield Unit 270) and these results were similary showned in each patient with different clinical site that was lung. prostate, liver and brain region. Concliusion : In conclusion we shown that the use of inhomogeneity correction algorithm for dose calculation in status of injected contrast medium can not represent exact dose at GTV region. These results mean that patients will be more irradiated photon beam during radiation therapy.

  • PDF

Predicting Factors of Chronic Subdural Hematoma Following Surgical Clipping in Unruptured and Ruptured Intracranial Aneurysm

  • Kwon, Min-Yong;Kim, Chang-Hyun;Lee, Chang-Young
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.5
    • /
    • pp.458-465
    • /
    • 2016
  • Objective : The aim of this study is to analyze the differences in the incidence, predicting factors, and clinical course of chronic subdural hematoma (CSDH) following surgical clipping between unruptured (UIA) and ruptured intracranial aneurysm (RIA). Methods : We conducted a retrospective analysis of 752 patients (UIA : 368 and RIA : 384) who underwent surgical clipping during 8 years. The incidence and predicting factors of CSDH development in the UIA and RIA were compared according to medical records and radiological data. Results : The incidence of postoperative CSDH was higher in the UIA (10.9%) than in the RIA (3.1%) (p=0.000). In multivariate analysis, a high Hounsfield (HF) unit (blood clots) for subdural fluid collection (SFC), persistence of SFC ${\geq}5mm$ and male sex in the UIA and A high HF unit for SFC and SFC ${\geq}5mm$ without progression to hydrocephalus in the RIA were identified as the independent predicting factors for CSDH development (p<0.05). Conclusion : There were differences in the incidence and predicting factors for CSDH following surgical clipping between UIA and RIA. Blood clots in the subdural space and persistence of SFC ${\geq}5mm$ were predicting factors in both UIA and RIA. However, progression to hydrocephalus may have in part contributed to low CSDH development in the RIA. We suggest that cleaning of blood clots in the subdural space and efforts to minimize SFC ${\geq}5mm$ at the end of surgery is helpful to prevent CSDH following aneurysmal clipping.

Effects of energy level, reconstruction kernel, and tube rotation time on Hounsfield units of hydroxyapatite in virtual monochromatic images obtained with dual-energy CT

  • Jeong, Dae-Kyo;Lee, Sam-Sun;Kim, Jo-Eun;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.49 no.4
    • /
    • pp.273-279
    • /
    • 2019
  • Purpose: This study was performed to investigate the effects of energy level, reconstruction kernel, and tube rotation time on Hounsfield unit (HU) values of hydroxyapatite (HA) in virtual monochromatic images (VMIs) obtained with dual-energy computed tomography (DECT)(Siemens Healthineers, Erlangen, Germany). Materials and Methods: A bone density calibration phantom with 3 HA inserts of different densities(CTWATER®; 0, 100, and 200 mg of HA/㎤) was scanned using a twin-beam DECT scanner at 120 kVp with tube rotation times of 0.5 and 1.0 seconds. The VMIs were reconstructed by changing the energy level (with options of 40 keV, 70 keV, and 140 keV). In order to investigate the impact of the reconstruction kernel, virtual monochromatic images were reconstructed after changing the kernel from body regular 40 (Br40) to head regular 40 (Hr40) in the reconstruction phase. The mean HU value was measured by placing a circular region of interests (ROIs) in the middle of each insert obtained from the VMIs. The HU values were compared with regard to energy level, reconstruction kernel, and tube rotation time. Results: Hydroxyapatite density was strongly correlated with HU values(correlation coefficient=0.678, P<0.05). For the HA 100 and 200 inserts, HU decreased significantly at increased energy levels(correlation coefficient= -0.538, P<0.05) but increased by 70 HU when using Hr40 rather than Br40 (correlation coefficient=0.158, P<0.05). The tube rotation time did not significantly affect the HU(P>0.05). Conclusion: The HU values of hydroxyapatite were strongly correlated with hydroxyapatite density and energy level in VMIs obtained with DECT.