• Title/Summary/Keyword: Hot-zone

Search Result 304, Processing Time 0.03 seconds

Analysis of Fluidization in a Fluidized Bed External Heat Exchanger using Barracuda Simulation (바라쿠다 시뮬레이션을 이용한 유동층 외부 열교환기의 유동해석)

  • Lee, Jongmin;Kim, Dongwon;Park, Kyoungil;Lee, Gyuhwa
    • Korean Chemical Engineering Research
    • /
    • v.58 no.4
    • /
    • pp.642-650
    • /
    • 2020
  • In general, the circulation path of the fluidized particles in a CFB (Circulating Fluidized Bed) boiler is such that the particles entrained from a combustor are collected by a cyclone and recirculated to the combustor via a sealpot which is one of non-mechanical valves. However, when a fluidized bed heat exchanger (FBHE) is installed to additionally absorb heat from the fluidized particles, some particles in the sealpot pass through the FBHE and then flow into the combustor. At this time, in the FBHE operated in the bubbling fluidization regime, if the heat flow is not evenly distributed by poor mixing of the hot particles (800~950 ℃) flowing in from the sealpot, the heat exchanger tubes would be locally heated and then damaged, and the agglomeration of particles could also occur by formation of hot spot. This may affect the stable operation of the circulating fluidized bed. In this study, the unevenness of heat flow arising from structural problems of the FBHE of the domestic D-CFB boiler was found through the operating data analysis and the CPFD (Computational Particle Fluid Dynamics) simulation using Barracuda VR. Actually, the temperature of the heat exchanger tubes in the FBHE showed the closest correlation with the change in particle temperature of the sealpot. It was also found that the non-uniformity of the heat flow was caused by channeling of hot particles flowing in from the sealpot. However, it was difficult to eliminate the non-uniformity even though the fluidizing velocity of the FBHE was increased enough to fluidize hot particles vigorously. When the premixing zone for hot particles flowing in from the sealpot is installed and when the structure is changed through the symmetrization of the FBHE discharge line for particles reflowing into the combustor, the particle mixing and the uniformity of heat flow were found to be increased considerably. Therefore, it could be suggested that the structural modification of the FBHE, related to premixing and symmetric flow of hot particles, is an alternative to reduce the non-uniformity of the heat flow and to minimize the poor particle mixing.

Effect of Flow Stress, Friction, Temperature, and Velocity on Finite Element Predictions of Metal Flow Lines in Forgings (유동응력, 마찰, 온도, 속도 등이 단조 중 단류선의 유한요소예측에 미치는 영향)

  • Choi, M. H.;Jin, H. T.;Joun, M. S.
    • Transactions of Materials Processing
    • /
    • v.24 no.4
    • /
    • pp.227-233
    • /
    • 2015
  • In this paper, the effect of flow stress, friction, temperature, and velocity on finite element predictions of metal flow lines after cylindrical upsetting is presented. An actual three-stage hot forging process involving an upsetting step is utilized and experimental metal flow lines are measured to study the effect of the various process variables. It was found that temperature and velocity for reasonable values of friction have little influence on metal flow lines especially those located deep within the cylinder but that flow stress has a direct influence on the flow lines. It was shown that a pure power law material model cannot reflect the real flow stress of hot material because it underestimates the flow stress especially around the dead-metal zone for the upsetting of a cylindrical specimen. It is thus recommended that a proper lower limit of flow stress be assumed to alleviate this issue.

Hydrogeological Characteristics and Groundwater Table Fluctuation of Dongrae Hot Spring (동래온천의 수리지질학적 특성과 수위변화)

  • Lee, Dong Young;Lim, Jeong Ung
    • Economic and Environmental Geology
    • /
    • v.28 no.2
    • /
    • pp.165-176
    • /
    • 1995
  • Dongrae is one of the most famous hot spring resort area in the Republic of Korea. The water temperature ranges $50^{\circ}C{\sim}66$. The chemical composition of the thermal water is quite different from normal groundwater. $Na^+$ and $Cl^-$ are the main components, measured more than 75%, $Ca^{+{+}}$ is contained about 22% and the other ions such as $SO_4$ or $HCO_3$ are the minor components. The heat source is uprising along the fracture zone of granite which is indicated as a subsurface high temperature belt. During the research period of 1991~1992, the groundwater table was lowered down to the depth of about 100 m according to continuous increase of daily use of thermal water. The groundwater table was fluctuated with an amplitude of day, weak or seasion. The groundwater table was the lowest at 18:00 h in a day and also lowest at the weekend for the week period. There was a relavent relationship between drawdown and the amount of thermal water use on a long term base. To protect such a rapid drawdown of groundwater table, Dongrae resort area is now asked to take strong municipal control for the daily use of thermal water.

  • PDF

Wideband Dual-polarized Microstrip Antenna with H-shaped Coupling Slot (H-커플링 슬롯 광대역 이중편파 마이크로스트립 안테나)

  • Kim, Jang Wook;Jeon, Joo Seong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.4
    • /
    • pp.71-79
    • /
    • 2014
  • This paper investigates wideband dual-polarized microstrip antenna with H-shaped coupling slot. These types of antennas are used to prevent deterioration of transmission quality caused by terminal interference or multipath fading, which usually occur when many terminals are used in limited space such as hot-spot zones. The experimental results show that the impedance bandwidth ($SWR{\leq}2$) of 33.98% and the peak gain of 8.58 dBi (at 2.11 GHz) were obtained by the frequency band under 2.7 GHz. The proposed antenna is designed originally for multiple service bands with simple structure and easily be mass-produced for various commercial applications.

Thermal sensation based humidity controls for improving indoor thermal comfort and energy efficiency in summer (온열감각 기반 습도제어를 통한 여름철 건물의 열쾌적 및 에너지성능 향상)

  • Moon, Jin Woo;Chin, Kyung-Il;Kim, Sang-Chul;Lee, Kwang Ho
    • KIEAE Journal
    • /
    • v.14 no.1
    • /
    • pp.75-81
    • /
    • 2014
  • This study aims at investigating the benefit of actively controlling humidity to improve thermal comfort and energy efficiency in climate zones other than hot-dry. For this research purpose, three thermal control strategies, which adopted different initiative degrees in humidity control, were developed - i) temperature controls, ii) temperature and humidity controls, and iii) thermal sensation controls. Performance of the developed strategies were experimentally tested in a full scale mock up of an office environment. The study revealed that air temperature was better controlled in the occupied zone under the first two strategies than the thermal sensation based strategy. On the other hand, the thermal sensation-based strategy maintained thermal sensation levels more comfortably. In addition, energy consumption was significantly reduced when humidity was actively controlled for thermal comfort. The thermal sensation-based control strategy consumed significantly less electricity than the first two strategies. From these findings, this study indicated that adoption of an active humidity control system based on thermal sensation can provide increased thermal comfort as well as energy savings for summer seasons in climatic zones other than hot-dry.

Remotely Operated Decontamination Systems for Use in DFDF

  • Kim, Kiho;Park, Jangjin;Myungseung Yang
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.438-446
    • /
    • 2003
  • This paper presents the development of the remotely operated decontamination systems for use in a highly radioactive zone of the DUPIC Fuel Development facility of the Irradiated Material Examination Facility at the Korea Atomic Energy Research Institute. The remotely operated decontamination systems were designed to completely eliminate human interaction with hazardous radioactive contaminants. These decontamination systems are mainly classified into three systems depending on the task environment - a fabrication equipment decontamination system, a hot-cell floor decontamination system, and an isolation room floor decontamination system. A decontamination system for contaminated fabrication equipment utilizes dry ice pellet blasting method to decontaminate contaminated surface of the equipment. The decontamination systems for the hot-cell floor and isolation room floor employ a vacuum cleaning method to decontaminate the contaminated floor and collect loose dry spent nuclear fuel debris and other radioactive waste placed on the floor. The human operator from the out-of-cell performs a series of decontamination tasks remotely by manipulating decontamination systems located in-cell via a handcontroller with the aid of vision feedback information. The environmental, functional and mechanical design considerations, control system and capabilities of the remotely operated decontamination systems at a high radioactive environment are also described.

  • PDF

Study of Optical Design Method for Ultra Slim Backlight System Using LED Light Source (LED광원을 이용한 초박형 백라이트에 대한 광학설계기법의 연구)

  • Han, Jeong-Min;Han, Jin-Woo;Kim, Byoung-Young;Kim, Jong-Yeon;Kim, Young-Hwan;Kim, Jong-Hwan;Seo, Dae-Shik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.432-432
    • /
    • 2007
  • We studied optical simulation method for ultra slim backlight system. We designed 0.7mm thickness light guide plate and combined 48 white color LEDs for 12 inch wide size TFT-LCD. We designed flat shape PMMA light guide plate with both side patterned. It have vertical prism shape on upper side and ellipse dot pattern on the other side. We targeted 4500 nit brightness and uniform emission characteristic without hot spot or dark area. At first, we designed uniform emission area with more high brightness in center area and then, debugged light entering hot spot zone and direction of outgoing light flux. Although it was designing step, we obtained good result with reverse prism optical sheet and it had good repeatability because it was based on the stamper method in injection process without laser engraving or micro groove engraving method.

  • PDF

Subscale high altitude simulation test using solid propellant gas generator (고체추진제 가스발생기를 이용한 축소형 고공환경모사 시험)

  • Kim, Yong-Wook;Lee, Jung-Ho;Yu, Byung-Il;Cho, Sang-Yeon;Oh, Seung-Hyub
    • Aerospace Engineering and Technology
    • /
    • v.7 no.1
    • /
    • pp.136-141
    • /
    • 2008
  • Cylindrical supersonic exhaust diffuser, which utilizes the momentum of high temperature gas exhausted from nozzle, provides simple methods for obtaining stable and low pressure around the propulsion system. Hot zone on which exhausted gas from nozzle exit impinges directly should be cooled to avoid melting of diffuser. This paper describes method and result of subscale high altitude simulation test with water cooling. Subscale gas generator with solid propellant was used for hot gas source and tap water for coolant.

  • PDF

Wake Flow Characteristics around the Side Mirror of a Passenger Car (승용차 외장측면거울 주위의 유동 특성)

  • Han, Yong-Oun;Kim, Jung-Hyun;Hwang, In-Ho;Seo, Jung-Bok;Lim, Byung-Hoon;Jung, Ui-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2573-2578
    • /
    • 2007
  • In order to investigate the vortex body frame interaction around the side mirror of a passenger car, velocity vector fields in the wake, pressure distributions and boundary layer flows over both the mirror surface and the mirror housing, have been measured by several experimental tools. It was resulted that only within an half downstream distance of the mirror span there appears the recirculation zone, and also found that vortex trail towards to the driver side window between A and B pillars, making the acoustic noise and vibration. Wake vortex rolls up after this recirculating zone and makes the trail of the vortex center towards the driver side window, which was also confirmed by measurements of wake velocity vectors in the vertical sections of the trail and visualization over the side mirror surfaces as well. It was also observed that total pressure distribution over the mirror surface has the minimum peak near the lower tip region which can be considered as the origin of the vortex center. It can be concluded that the geometrical modification of the lower tip and the upper root area of the mirror housing is the key to control the wake vortex.

  • PDF

Analysis and Design of a Forming Porcess for Combined Extrusion with Aluminum AIIoy 7075 (알루미늄 7075 복합압출재에 대한 공정해석 및 설계)

  • 김진복;변상규
    • Transactions of Materials Processing
    • /
    • v.6 no.5
    • /
    • pp.446-455
    • /
    • 1997
  • A Combined extrusion operation consists of forward and backward extrusion forming and it is possible to make the process be simple by employing it. But the metal flow pattern induced by the operation is hard to analyze accurately because the flows are non-steady, which have at least two directions dependent upon each other. So engineers in the industrial factories had conducted the two extrusion operations separately. A new process was designed by the industrial expert for forming of an alu-minum preform using the combined extrusion operation. In this study, experiments and finite element analysis was carried out to determine the process parameters. Through the preliminary experiment, it was shown that warm forming condition was more desirable than cold or hot ones. And optimal shape of initial billet could be also determined. From the compatibility test, bonde-lube was chosen as the optimal lubricant and 20$0^{\circ}C$ as the material temperature by the inspection of micro-structure. The operation was simulated by the rigid-plastic finite element method to examine the metal flow. Disap-pearing of dead metal zone was observed as the punch fell down and desirable shape was obtained from the one operation. As a result of this study, 7 operations could be reduced and 225% of material saved.

  • PDF