• Title/Summary/Keyword: Hot-Spot Temperature

Search Result 133, Processing Time 0.023 seconds

SW Lyncis-Advances and Questions

  • Kim, Chun-Hwey;Kim, Ho-Il;Yoon, Tae-Seog;Han, Won-Yong;Lee, Jae-Woo;Lee, Chung-Uk;Kim, Jin-Hyung;Koch, Robert H.
    • Journal of Astronomy and Space Sciences
    • /
    • v.27 no.4
    • /
    • pp.263-278
    • /
    • 2010
  • Many filtered CCD measures form the basis of six new light curves of the eclipsing system SW Lyn. From these measures and additional observations for eclipse timing, 47 new times of minimum light over the time-interval of about 13 years have been calculated. The complex period variability can be sorted into a linear period improvement with 5.8-year and 33.9-year periodic terms. The shorter cyclic term of these is ascribed to a cool companion of the eclipsing pair but the longer one has no testable interpretation at present. The new light curves are synthesized by the 2003 version of the Wilson-Devinney differential corrections computer code. The results incorporate a source of "third light" which comes from the cool companion star that had been identified by the cycling of the period of the eclipsing pair and also had previously been identified spectroscopically. There is a measure of satisfaction with current understanding of the SW Lyn eclipsing system because of consistent syntheses of all historical light curves. This agreeable convergence, however, comes partly at the expense of an unanticipated temperature of the hot star and of a photospheric spot that has no obvious basis in the detached character modeled for the binary. We offer predictions of changes in the stellar parameters if the modeled detached-configuration should be wrong. The SW Lyn stellar system is still difficult to understand.

Design of Commercial 2,3-Butanediol Dehydration Reaction System Considering Safety (안전을 고려한 상용 2,3-Butanediol 탈수반응 시스템 설계)

  • Song, Daesung
    • Korean Chemical Engineering Research
    • /
    • v.58 no.4
    • /
    • pp.581-587
    • /
    • 2020
  • In this study, a new reaction system is proposed to solve the problems of the existing 2,3-Butanediol (2,3-BDO) dehydration reaction system. It was confirmed that the reaction system did not wok as it should operate properly when using a furnace, which is commonly used in commercial processes, to raise the reactant, 2,3-BDO, to the reaction temperature, 360 ℃, at near atmoshperic pressure. It is because of the substance considered to be oligomers of 2,3-BDO. It can lead to safety problems, such as blockages inside the furnace's tube and explosions, as well as tricky maintenance issues in the reaction system. To solve it, the temperature of reactant can be brought down by using a heat exchanger with High Pressure (HP) steam instead of the furnace, which has a hot spot problem through the vacuum operation and reduce the reaction temperature. It can be seen that the reactor performance is almost similar under the vacuum operation and the lower reaction temperature, 330 ℃, by using a reaction kinetics. This result explains why the new reaction system is proposed.

Application of Flexible-Type Sintered Brake Pads (플렉서블 타입 소결 브레이크 패드의 적용 연구)

  • Kim, Soung-Kwon;Kim, Sang-Ho;Kwon, Seok-Jin;Lee, Hi-Sung
    • Tribology and Lubricants
    • /
    • v.27 no.1
    • /
    • pp.19-24
    • /
    • 2011
  • Metallic sintered brake pads are often applied to mid/high speed train due to their high strength and thermal characteristics. Imbalance contact between discs and pads can greatly influence the life span, one sided wear, discs attack/crack and threat the safety of the train during operation. In this research, we analyzed pressure/temperature distribution between brake pads and disks. Analyzed data had been verified and modified to conduct further tests of flexible brake pads with small/full-scale dynamo test. Flexible brake pads were installed to high speed train to conduct further tests to identify the differences between rigid brake pads and flexible brake pads. In result, Flexible brake pads showed outstanding disk thermal stability, one sided wear, noise and wear rate than rigid brake pad.

Comparision of Combustion Characteristics of the Different Property Coal in Cyclone Combustor (사이클론 연소기에서 성상이 다른 석탄의 연소 특성 비교)

  • Hong, Sung-Sun;Hwang, Kap-Sung;Choi, Byung-Sun
    • Applied Chemistry for Engineering
    • /
    • v.5 no.2
    • /
    • pp.337-344
    • /
    • 1994
  • Two coals which have a quite different properties were selected to compare the combustion characteristics in a cyclone combustor. The capacity of the combustion test rig is about 75kW and total volume is 5.7 liters. The pulverized sample coals are well burned from fuel rich(air ratio 0.4) to fuel lean(airs ratio 1.6). Two different property coals show quite different patterns of ash collection in slag pot, dust separator and combustion chamber. Combustion temperature of subbituminous coal is about $100^{\circ}C$ lower than bituminous coal at the entire region, and in case of bituminous coal, hot spot appeared at the lower part and axial line of the combustion chamber.

  • PDF

Electromagnetic Indirect Induction Fluid Heating System using Series Resonant PWM Inverter and Its Performance Evaluations (직렬공진 PWM인버터를 이용한 전자간절유도가열 열유체 에너지시스템과 그 성능평가)

  • 김용주;김기환;신대철
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.1
    • /
    • pp.48-54
    • /
    • 2002
  • This paper is described the indirect induction heated boiler and induction heated hot air producer using the voltage-fed series resonant high-frequency inverter which can operate in the frequency range from 20 kHz to 50 kHz. A specially designed induction heater is composed of laminated stainless plates, which have many tiny holes and are interconnected by spot welding. This heater is inserted into the ceramic type vessel with external working coil. This working coil is connected to the inverter and turbulence fluid through this induction heater to moving fluid generates in the vessel. The operating performances of this unique appliance in next generation and its effectiveness are evaluated and discussed from a practical point of view.

A study on the S/W application for a riser design process for fabricating axisymmetric large offshore structures by using a sand casting process

  • Seo, Hyung-Yoon;Seo, Pan-Ki;Kang, Chung-Gil
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.11 no.1
    • /
    • pp.462-473
    • /
    • 2019
  • The effects of the location and dimension of the gate, location, and volume of the feeder, application of a chill, chill volume, and heating method of the feeder with respect to the effect of the mold-designing technologies on the defect status of the products are described. It is possible to increase the solidification time of the feeder by heating feeder. Furthermore, the pressure generated from the feeder is imposed on a product, and this decreases the generation of shrinkage porosities. In this study, two types of gating and feeding systems had been proposed: the bottom L-type junctions and the top L-type junctions. Additionally, solidification behaviors, such as solidification time, shrinkage porosities, weight percentage of chill system to product, hot spot, and solidification time ratio (=Solidification time of feeder/solidification time of product), are extensively analyzed by using commercial casting simulation software. Based on the solidification behaviors, reasonable mold design, feeding system, critical feeder heating temperature, and solidification time ratios are proposed in the sand casting process for the fabrication of carrier housing in order to reduce the casting defects and to increase the recovery rate.

An Analysis of TYLCV Damages under Regional Climate Changes (지역별 기후변화에 따른 토마토 황화잎말림병 피해 분석)

  • Yoon, Jiyoon;Kim, Soyoon;Kim, Kwansoo;Kim, Brian H.S.;An, Donghwan
    • Journal of Korean Society of Rural Planning
    • /
    • v.21 no.4
    • /
    • pp.35-43
    • /
    • 2015
  • The purpose of the research is to analyze damages of TYLCV (Tomato Yellow Leaf Curl Virus) in the context of climate changes and to find the spatial distribution of the damages and characteristics of regions. A TYLCV is generally known for a plant disease related to temperature. Its occurrence rate increases when temperature rises. This disease first occurred in 2008 and rapidly spread nationwide. Due to the spread of a TYLCV, a number of Tomato farms in Korea were damaged severely. To analyze damages of the pest in the context of climate changes, this research estimated production loss under the current situation and RCP scenarios. Additionally, Hot Spot Analysis, LISA, and Cluster analysis were conducted to find spatial distribution and properties of largely damaged regions under RCP scenarios. The results explained that additional production loss was estimated differently by regions with the same temperature rising scenario. Also, largely damaged regions are spatially clustered and factors causing large damages were different across regional cluster groups. It means that certain regions can be damaged more than others by diseases and pests. Furthermore, pest management policy should reflect the properties of each region such as climate conditions, cultivate environment and production technologies. The findings from this research can be utilized for developing rural management plans and pest protection policies.

Design of the Fixed-Bed Catalytic Reactor for the Maleic Anhydride Production (무수마레인산 생산을 위한 고정층 촉매 반응기 설계)

  • Yoon, Young Sam;Koo, Eun Hwa;Park, Pan Wook
    • Applied Chemistry for Engineering
    • /
    • v.10 no.3
    • /
    • pp.467-476
    • /
    • 1999
  • This paper analyzed the behavior of fixed-bed catalytic reactor (FBCR) which synthesizing maleic anhydride(MA) from the selective oxidation of n-butane. The behavior of FBCR describing convection-diffusion-reaction mechanism is examined by using two-dimensional pseudohomogeneous plug-flow transient model, with the kinetics of Langmuir-Hinshelwood type. Prediction model is composed by optimum parameter estimation from temperature profile, yield and conversion of single FBCR on operating condition variations of Sharma's pilot-plant experiment. A double FBCR with same yield and conversion for single FBCR generated a $8.96^{\circ}C$ lower hot spot temperature than a single FBCR. We could predict parametric sensitivity according to the variation of possible operating condition (temperature, concentration, volumetric flow of feed reactant and coolant flow rate) of single and double FBCR. Double FBCR showed the behavior of more operating range than single FBCR. Double FBCR with nonuniform activities could assure safety operation condition for the possible variation of operating condition. Also, double FBCR had slightly higher than the single FBCR in conversion and yield.

  • PDF

Operating Properties for a Resistive SFCL of YBCO Thin Films (YBCO 박막의 저항형 초전도 한류기에 대한 동작 특성)

  • Choe, Hyo-Sang;Hyeon, Ok-Bae;Kim, Hye-Rim;Hwang, Si-Dol;Kim, Sang-Jun;Mun, Seung-Hyeon;Han, Byeong-Seong
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.10
    • /
    • pp.537-543
    • /
    • 1999
  • We fabricated a resistive superconducting fault current limiter (SFCL) of a meander type based on a YBCO film with the meander cross section of 5 $\times$ $10^{-6}$$cm^2$, and performed current limitation experiments. The film was coated quench current was 9.6 Apeak at 60 Hz, and the fast quench time was 0.63 msec. The resistance of the limiter continuously increased for three cycles dut to the temperature rise in the gold layer. The temperature of the current limiting element reached the room temperature in 11 msec, $150^{\circ}C$ in 54 msec after quench, and was saturated afterwards. For $45^{\circ}$and $90^{\circ}$faults the fast quench times were 0.56 msec and 0.26 msec, respectively. The quench time is believed to be reduced because the fault occurred when the current was either increasing or at the peak value. This limiter effectively limited the fault current to about 1/5 of the potential current with no SFCL right after the fault and to about 1/8.5 in three cycles. We confirmed that the gold layer effectively carried out the role of heat dissipation as the SFCL was quenched.

  • PDF

Rapid cooling of injection mold for high-curvature parts using CO2 cooling module (CO2 냉각모듈을 적용한 고곡률 성형품의 사출금형 급속냉각)

  • Se-Ho Lee;Ho-Sang Lee
    • Design & Manufacturing
    • /
    • v.16 no.4
    • /
    • pp.67-74
    • /
    • 2022
  • Injection molding is a cyclic process comprising of cooling phase as the largest part of this cycle. Providing efficient cooling in lesser cycle times is of significant importance in the molding industry. Recently, lots of researches have been done for rapid cooling of a hot-spot area using CO2 in injection molding. The CO2 flows under high pressure through small, flexible capillary tubes to the point of use, where it expands to create a snow and gas mixture at a temperature of -79℃. The gaseous CO2 removes heat from the mold and releases it into the atmosphere. In this paper, a CO2 cooling module was applied to an injection mold in order to cool a large area cavity uniformly and quickly, and the cooling performance of the injection mold was investigated. The product was a high-curvature molded part with a molding area of 300x100mm. Heat cartridges were installed in a stationary mold, and CO2 cooling module was inserted inside a movable mold. Through structural analysis, it was confirmed that the maximum deformation of mold with CO2 cooling module was 0.09mm. A CO2 feed system with a heat exchanger was used for cooling experiments. The CO2 was injected into the holes on both sides of the supply pipe of the cooling module and discharged through hexagon blocks to cool the mold. It took 5.8 seconds to cool the mold from an average temperature of 140℃ to 70℃. Through the experiment using CO2 cooling module, it was found that a cooling rate of up to 12.98℃/s and an average of 10.18℃/s could be achieved.