• 제목/요약/키워드: Hot waste water

검색결과 133건 처리시간 0.023초

직접접촉식 열교환기내에서 물과 배기가스의 직접접촉에 의한 열 및 물질전달 (Heat and Mass Transfer between Hot Waste Gas and Cold Water in a Direct Contact Heat Exchanger)

  • 이금배
    • 대한기계학회논문집
    • /
    • 제16권6호
    • /
    • pp.1171-1178
    • /
    • 1992
  • 본 연구에서는 직접접촉식 열교환기를 이용한 실험을 통하여 열교환기 설계에 가장 중요한 열교환기 단위 체적당 총괄 열전달 계수를 시스템의 작동조건에 따라 구 하여 실제 설계자료로 이용하는 데 그 목적이 있다.

프로세스 시뮬레이션에 의한 제 2종 흡수식 열펌프 성능에 관한 연구 (A Study on the Performance of an Absorption Heat Transformer with Process Simulation)

  • 조승연;김영인
    • 대한설비공학회지:설비저널
    • /
    • 제16권3호
    • /
    • pp.295-304
    • /
    • 1987
  • The purpose of this study is to develop a computer model for simulating the water-lit hium bromide absorption heat transformer (AHT) Including all major components and to find the flexibility in operation. The effect of source hot water temperature, cooling water temperature, useful hot water flow rate, cooling water flow rate and evaporator circulation flow rate were investigated. The coefficient of performance (COP), temperature boost $({\Delta}T\;=\;T_A\;-\;Ti)$ and concentration variations can be predicted. The performance study indicates that the performance of AHT increases for the waste hot water temperature increasing and with a decrease of the cooling water temperature. The effect on performances of useful hot water flow rape is significant except on temperature boost. Also the effects on performance of cooling water flow rate and evaporator circulation flow rate are small. It is shown that the computer program is valuable to predict the performance of absorp-tion heat transformer units at various working corditions.

  • PDF

식품소재로서 굴통조림 가공부산액의 성분 특성 (Component Characteristics of Canned Oyster Processing Waste Water as a Food Resource)

  • 김진수;허민수;염동민
    • 한국식품영양과학회지
    • /
    • 제30권2호
    • /
    • pp.299-306
    • /
    • 2001
  • As a part of basic investigation for utilization of canned food processing by-products, a food components of the canned oyster processing waste water such as boiled and released water(BRW), wash water(WW) were investigated and compared with hot-water extracts from oyster. From the results of measuring heavy metal conte수, viable cells and coliform group, the canned oyster processing waste waters might not invoke health risk in using food resource. The contents of taste compounds (free amino acids, ATP related compounds, TMA (O) and total creatinine) of BRW and WW accounted for about 254% and 95%, respectively, in comparison with those of control (hot-water extract from oyster). The BRW showed a very high content of salt in comparing to the WW and control. In descending order, the values of whiteness index was WW, control and BRW. Sensory scores for color, oyster flavor intensity and saline taste were not significantly different between WW and control. But, BRW had the highest score in oyster flavor intensity, while had the lowest score in color and saline taste. But, the color and saline taste of BRW might be able to control by some pretreatment (concentration and drying in mild condition, desalination and recipe control etc). These results indicated that BRW and WW generated from various step during canned oyster processing could be a potential food resource by controlling of saline taste and color intensity.

  • PDF

Control of Water Heat Recovery Chiller Using Split Condenser Templifier Application

  • Cho, Haeng-Muk;Mahmud, Iqbal
    • 에너지공학
    • /
    • 제18권1호
    • /
    • pp.17-21
    • /
    • 2009
  • By using the heat recovery of water-cooled chillers, it is possible to reduce the energy operating costs positively and at the same time it could fulfill the heating re-heat air conditioning system as well as the hot water requirements. Basically templifiers are designed to economically to turn the waste heat into useful heat. Waste heat is extracted from a fluid stream by cooling it in the evaporator, the compressor amplifies the temperature of the heat and the condenser delivers the heat to heating loads such as space heating, kitchens and domestic hot water. Design of higher water temperature requirements and split condenser heat recovery chiller system (using of templifiers) produced hotter condenser water approximately up to $60^{\circ}C$ and control the entire heat recovery system.

Recovery of Silk Sericin from Soap-Alkaline Degumming Solution

  • Yang, Yesol;Lee, Sang Mi;Lee, Han Sol;Lee, Ki Hoon
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • 제27권1호
    • /
    • pp.203-208
    • /
    • 2013
  • Sericin is usually abandoned after the degumming process. However, it could be a valuable bioresource if an economically efficient recovery process could be set up. In this study, sericin was recovered directly from the degummed waste solution by adding calcium chloride, which induced the precipitation of the surfactant, sodium oleate, by charge interaction. The recovery yield was maximum when 10% of calcium chloride was added. Further increase in the calcium chloride concentration induced the precipitation of sericin. The recovered sericin had a molecular weight distribution similar to that of the hot-water-extracted sericin; but some highmolecular- weight sericin could not be recovered. The secondary structure and amino acid composition of the recovered sericin were similar to those of conventional hot-water-extracted sericin. We expect that sericin recovered from the degummed waste solution could be an alternative to the hot-water-extracted sericin, which is widely used in various applications.

냉매 열교환기 구성방법에 따른 제 2종 흡수식 히트펌프의 성능 특성 변화에 관한 연구 (Performance Characteristics of Type II LiBr-H2O Absorption Heat Pump in Accordance with the Refrigerant Heat Exchanger Configuration)

  • 이창현;윤준성;김인관;권오경;차동안;배경진;김민수;박찬우
    • 설비공학논문집
    • /
    • 제29권7호
    • /
    • pp.373-384
    • /
    • 2017
  • The objective of this study was to determine the effect of refrigerant heat exchanger on the performance of type II absorption heat pump performance using numerical analysis. Two heat exchange installation methods were used: solution to refrigerant and waste hot water to refrigerant. These methods were compared to the standard model of hot water flow without using refrigerant heat exchanger. When waste hot waters were bypassed to refrigerant heat exchanger, COP was not affected. However, steam mass generation rates were increased compared to those of the standard model. When solutions were bypassed to the refrigerant heat exchanger, results were different depending on the place where the solution rejoined. COP and steam mass generation rates were lower compared to those when waste heat water was passed to refrigerant heat exchanger. Thus, it is possible to obtain higher steam mass generation rates by using waste water and installing refrigerant heat exchanger.

온배수를 이용한 혼합냉매용 해양온도차 발전 사이클의 성능 특성 (Performance Characteristics of a Mixed Refrigerant OTEC Power Cycle Using Hot Waste Water)

  • 윤정인;손창효;허정호;예병효;김현주;이호생
    • 동력기계공학회지
    • /
    • 제17권6호
    • /
    • pp.102-107
    • /
    • 2013
  • In this paper, the performance analysis for evaporation capacity, total work and efficiency of the ocean thermal energy conversion(OTEC) power system using mixed refrigerant(R32,R152a) is conducted to find the effect of hot wasted water on OTEC power system. The system in this study is applied with two stage turbine, regenerator, cooler and separator on Organic Rankine Cycle. The commercial program HYSYS is used for the performance analysis. The main results were summarized as follows : The efficiency of the OTEC power cycle has a largely effect on the evaporation capacity and total work. As increasing temperature of heat source water, evaporator's capacity is decreased but total work increase. Otherwise, using hot wasted water bring effects not only increasing system efficiency but also declining evaporator's capacity. Thus With a thorough grasp of these effect, it is necessary to find way to use hot wasted water emitted by power plant and so on.

쓰레기 소각로의 2차공기가 유동현상에 미치는 현상 연구 (Study for a Secondary Air Affecting Fluid Flow in a Solid Waste Incinerator)

  • 이금배
    • 대한기계학회논문집B
    • /
    • 제20권9호
    • /
    • pp.2924-2932
    • /
    • 1996
  • As the environmental pollution can be greatly reduced and the waste heat can be also recovered through a combustion of municipal solid waste, the incineration begins to be highlighted recently in our country. But it is very difficult to be operated with constant combustion conditions for a long time as the domestic waste is composed of various components, contains a large percentage of water, and has a low heating value. Therefore, the cold flow test and partial hot flow test were conducted in the incinerator by use of injection angles of a secondary air affecting fluid flow as the first action to maintain the optimum combustion conditions. A model to a scale of 1:10 was designed and manufactured through the similarity of model and prototype flows. Velocities and temperatures were measured through the experiment. From the results, fluid flows of secondary air obtained from partial hot flow test correspond almost well with those of main flow obtained from cold flow test. Consequently, injection angles of secondary air are proved to affect main flow decisively.