• Title/Summary/Keyword: Hot plate

Search Result 690, Processing Time 0.026 seconds

Analgesic Effects of Sokyungwhalhyul-tang on Constriction Nerve Injury-Induced Neuropathic Pain in Rats (말초 신경병증성 통증 모델에서 소경활혈탕의 진통 효과)

  • Kim, Kyung-Yoon;Jeong, Hyun-Woo;Choi, Chan-Hun;Kim, Hyung-Woo;Kim, Gi-Do;Sim, Ki-Cheol;Kim, Gye-Yeop
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.25 no.2
    • /
    • pp.195-201
    • /
    • 2011
  • Nardostachys chinensis;Anti-proliferation;Cell cycle arrest;Differentiation;U937 cells; This study was conducted to determine the analgesic effect of Sokyungwhalhyul-tang(SKWHT) using the model of peripheral neuropathic pain model. A model of neuropathic pain was made by ligating left 5th lumbar spinal nerve of rats. After 1 days, the extract of SKWHT was orally administered daily. Rats were divided into four groups; (1) Control group(n=6), (2) Experimental group I(SKWHT-OA1, 100 mg/kg, n=6), (3) Experimental group II(SKWHT-OA2, 300 mg/kg, n=6), (4) Experimental group III(SKWHT-OA3, 500 mg/kg, n=6). After that, we examined the withdrawl response of neuropathic rats legs by von Frey filament and Hot plate at pre, $1^{th}$, $4^{th}$, $7^{th}$, $14^{th}$, $21^{th}$ days after the induction of neuropathic pain. And also we examined c-fos, GOT, GPT and histological study of Liver at 21th days. von Frey filament and Hot plate were increase in experimental group I, II, III than Con. especially group III was most significantly analgesic effect than the other groups at $14^{th}$, $21^{th}$ days. In c-fos protein expression on spinal cord, group III was most significantly reduction immunoreactivity at $21^{th}$ days and in blood serum GOT & GPT levels and histologic finding of Liver in all experimental groups were no significant difference with Con at $21^{th}$ days. According to the above results, SKWHT(500 mg/kg) may have a significant analgesic effect on the neuropathic pain.

Desmutagenic Effect of Water Extract from Artemisia capillaris THUNB on the Mutagenicity of Benzo[a]pyrene (Benzo[a]pyrene의 변이원성에대한 인진쑥 물 추출물의 항돌연변이 효과)

  • 안병용
    • KSBB Journal
    • /
    • v.15 no.4
    • /
    • pp.331-336
    • /
    • 2000
  • The antimutagenic activity of the extract of Artemisia capillaris THUNB on the mutagenicity induced by benzo(a)pyrene [B(a)P] in the presense of S9 mixture was studied using bacterial mutagenic assay system. Samples harvested in summer and autumn were extracted using ethanol and hot water. Among these extracts the water extract of summer sample had the strongest inhibitory effect against the mutagenenicity of B(a)P, The water extract of Artemisia capillaris THUNB was separated again into ethanol soluble and insoluble parts. The ethanol insoluble part(El) of water extract exhibited higher inhibition effects than the ethanol soluble part against the mutagenic activity of B(a)P. El showed dose-dependent activity on the mutagenicity of B(a)P in SOS Chromotest and Ames test. The 50% inbibition concentraction $(IC_{50}$ of El were $200{\mu}g/assay$ $600{\mu}g/plate$ and $800{\mu}b/plate$ in E. coil PQ37 S. typhimurium TA100 and TA98 respectively. El were showed desmutagenic effect but had no effect on the DNA repair system for B(a)P-induced mutagenesis. HPLC analysis showed that the formation of aflatoxin M1 by cytochrome P-450 1A1 known as playing an impotant role on B(a) P-induced mutagenicity was highly inhibited by El. Therefore we encluded that B(a)P-induced mutagencity can be reduced possible due to the interference of el with cytochrome P-450 1A1-dependent bioactivation.

  • PDF

Quasi-monochromatic Parallel Radiography Achieved with a Polycapillary Plate

  • Sato, Eiichi;Komatsu, Makoto;Hayasi, Yasuomi;Tanaka, Etsuro;Mori, Hidezo;Kawai, Toshiaki;Ichimaru, Toshio;Takayama, Kazuyoshi;Ido, Hideaki
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.418-421
    • /
    • 2002
  • Fundamental study on quasi-monochromatic parallel radiography using a polycapillary plate and a plane-focus x-ray tube is described. The x-ray generator consists of a negative high-voltage power supply, a filament (hot cathode) power supply, and an x-ray tube. The negative high-voltage is applied to the cathode electrode, and the transmission type target (anode) is connected to the ground potential. The maximum voltage and current of the power supply were -100 kV (peak value) and 3.0 mA, respectively. In this experiment, the tube voltage was regulated from 20 to 25 kV, and the tube current was regulated by the filament temperature and ranged from 1.0 to 3.0 mA. The exposure time is controlled in order to obtain optimum film density, and the focal spot diameter was about 10 mm. The polycapillary plate is J5022-21 made by Hamamatsu Photonics Inc., and the outside and effective diameters are 87 and 77 mm, respectively. The thickness and the hole diameter of the polycapillary are 1.0 mm and 25 ${\mu}$m, respectively. The x-rays from the tube are formed into parallel beam by the polycapillary, and the radiogram is taken using an industrial x-ray film of Fuji IX 100 without using a screen. In the measurement of image resolution, we employed three brass spacers of 2, 30, and 60 mm in height. By the test chart, the resolution fell according to increases in the spacer height without using a polycapillary. In contrast, the resolution slightly fell with corresponding increases in the height by the polycapillary. In angiography, fine blood vessels of about 100 ${\mu}$m are clearly visible.

  • PDF

Degradation Behavior of Eutectic and Pb-free Solder Plated Ribbon in Crystalline Silicon Photovoltaic Module (유무연 용융도금 리본에 따른 결정질 실리콘 태양전지 모듈 열화거동)

  • Kim, Ju-Hee;Kim, A Yong;Park, Nochang;Ha, Jeong Won;Lee, Sang Guon;Hong, Won Sik
    • Journal of Welding and Joining
    • /
    • v.32 no.6
    • /
    • pp.75-81
    • /
    • 2014
  • Usage of heavy metal element (Pb, Hg and Cd etc.) in electronic devices have been restricted due to the environmental banning of the European Union, such as WEEE and RoHS. Therefore, it is needed to develop the Pb-free solder plated ribbon in photovoltaic (PV) module. This study described that degradation characteristics of PV module under damp heat (DH, $85^{\circ}C$ and 85% R.H.) condition test for 1,000 h. Solar cell ribbons were utilized to hot dipping plate with Pb-free solder alloys. Two types of Pb-free solder plated ribbons, Sn-3.0Ag-0.5Cu (SAC305) and Sn-48Bi-2Ag, and an electroless Sn-40Pb solder hot dipping plated ribbon as a reference sample were prepared to evaluate degradation characteristics. To detect the degradation of PV module with the eutectic and Pb-free solder plated ribbons, I-V curve, electro-luminescence (EL) and cross-sectional SEM analysis were carried out. DH test results show that the reason of maximum power (Pm) drop was mainly due to the decrease fill factor (FF). It was attributed to the crack or oxidation of interface between the cell and the ribbon. Among PV modules with the eutectic and Pb-free solder plated ribbon, the PV module with SAC305 ribbon relatively showed higher stability after DH test than the case of PV module with Sn-40Pb and Sn-48Bi-2Ag solder plated ribbons.

Fabrication of Full-Scale Combustion Chamber of Liquid Rocket Engine for Ground Hot Firing Tests (실물형 고압 연소기의 연소시험 검증용 제작)

  • Kim Jonggyu;Seo Seonghyeon;Kim Seunghan;Han Yeoungmin;Ryu Chulsung;Seol Wooseok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • v.y2005m4
    • /
    • pp.305-308
    • /
    • 2005
  • This paper presents a fabrication of a full-stale combustion chamber of a liquid rocket engine for a ground hot firing test. Engine drawings for manufacturing were prepared after conceptual and detail designs. The combustor is composed of a head and a chamber. SUS316L is used for materials of the head because of the good quality in low temperature. Inner materials of the ablative cooling chamber is silica/phenolic and outer case materials is the SUS316L. Materials of the regenerative cooling chamber are C18200 and SUS316L. After lathe, general milling and MCT machinings, components were finished by electrolytic polishing. A brazing method was applied for bonding the injectors and the injector plate, the regenerative cooling chamber because of structure configurations.

  • PDF

In-Patients' Food Consumption and Perception on Foodservice Quality at Hospitals (환자들의 병원급식 섭취 실태 및 병원급식 품질 속성에 대한 인식 분석)

  • Kim, Min-Young;Kim, Kyung-Joo;Lee, Kyung-Eun
    • Journal of the Korean Dietetic Association
    • /
    • v.14 no.1
    • /
    • pp.87-96
    • /
    • 2008
  • The purposes of this research were to investigate in-patients' perception on foodservice quality and to examine factors influencing their meal consumption at hospitals. Three general hospitals with over 400 beds in Seoul and Chon-An agreed to participate in the research. A total of 516 in-patients of the hospitals were surveyed on their meal consumptions, reasons of plate wastes, perceptions of foodservice quality, and demographic information. A response rate was 76% after excluding responses with significant missing data. On average the regular diet patients consumed 72%, 69%, and 68% of rice, soups, and side dishes served, respectively; the therapeutic diet patients consumed less than 70% of the meals they were served. The consumption rates did not differ significantly by diet type, gender, age, and hospitalization period. Among the therapeutic diet patients, those who had nutrition education consumed significantly more rice than the others (p<0.05). The main reasons why the patients did not eat all food served were 'lack of energy' and 'not tasty'. The patients' perception on foodservice quality was low; the therapeutic diet patients perceived more negatively than the regular diet patients in 'keeping hot food hot, cold food cold(p<0.05)', 'maintaining consistency of taste(p<0.01)', and 'providing nutrition information(p<0.01)'. To achieve the goal of the foodservice at hospitals, the dietitians can use the findings of the research in developing and implementing strategies to improve the patients' meal consumption. Recipe standardization, employee training, and production management will be useful for improving food quality and nutrition education on therapeutic diets for the patients will improve their meal consumption at hospitals.

  • PDF

A Numerical Analysis on Transient Fuel temperatures in a Military Aircraft under Non-operating Ground Static Condition (지상 정적 상태에서의 항공기내 연료온도변화에 대한 수치해석)

  • 김영준;김창녕
    • Journal of Energy Engineering
    • /
    • v.12 no.1
    • /
    • pp.11-16
    • /
    • 2003
  • A numerical study was performed on the transient fuel temperatures of a military aircraft stationed under non-operating static condition. Numerical calculation was peformed by an explicit method using modified Dufort-Frankel scheme. It was assumed that the non-operating aircraft is subjected to repeated daily cycles of air temperature with the solar radiation and wind speed corresponding to the 1 % hot day ambient condition. And, the aircraft was assumed to be in turbulent flow. The convective heat transfer coefficient for turbulent flow on the flat plate suggested by Eckert was employed to calculate heat transfer between the aircraft surface and the ambience. The energy conservation equation on fuel was used as governing equation for this analysis. As a result of this analysis, the wing tank temperature showed the highest temperature and the largest rate of temperature changes among fuel tanks. The results of this analysis could be used as initial foe] temperatures for analysis of the transient fuel temperatures in various flight missions. Also, this analysis method could be used to analysis and design of an aircraft thermal energy management system.

Anti-inflammatory and anti-noceceptive action of the crude extracts of Costus specious on rodents

  • Alam, Ashraful;Subhan, Nusrat;Awal, Abdul;Alam, Shohidul;Akramudau, Kazi
    • Advances in Traditional Medicine
    • /
    • v.8 no.3
    • /
    • pp.243-251
    • /
    • 2008
  • The effect of alcoholic extracts of Costus specious (Family: Zingiberaceae) was evaluated in experimental models of pain and inflammation. Oral administration of 100, 200 and 300 mg/kg of C. specious extracts were used for the above study. Crude extracts of C. specious (300 mg/kg dose) showed maximum time needed for the response against thermal stimuli ($7.242\;{\pm}\;0.532\;s$) which is comparable to diclofenac sodium ($8.471\;{\pm}\;0.25\;s$) in the hot plate test. The MPH (Maximum Possible Analgesia) has been found to be 14.285 for 300 mg/kg dose of the crude extract while the MPH for diclofenac was 15.857 after 60 min of administration in the hot tail-flick method. The crude extract at 300 and 200 mg/kg doses showed significant reduction in acetic acid induced writhings in mice with a maximum effect of 59.661% reduction at 300 mg/kg dose which is comparable to standard diclofenac sodium (73.4%). Alcoholic extract of C. specious showed significant inhibition in serotonin and egg albumin induced hind paw oedema in rats at 100, 200 and 300 mg/kg of the crude extracts respectively (Serotonin induced edema 44.22; 53.75; 58.51%; egg albumin induced edema - 41.317; 53.892; 59.880% inhibition after 4 h respectively). The antiinflammatory effects showed by the extract were comparable to that of standard indomethacin 5 mg/kg (Serotonin induced edema 77.56%; egg albumin induced edema 77.844% inhibition after 4 h). These results suggest that the extract possesses both the anti-inflammatory and analgesic activity on mice and rat model.

The Effect of Diaphragm inside Trough Rib on Fatigue Behavior of Trough Rib and Cross Beam Connections in Orthotropic Steel Decks (강바닥판 종리브와 횡리브 교차부의 피로거동에 대한 종리브내 다이아프램의 영향)

  • Choi, Dong Ho;Choi, Hang Yong;Choi, Jun Hyeok
    • Journal of Korean Society of Steel Construction
    • /
    • v.12 no.3 s.46
    • /
    • pp.239-250
    • /
    • 2000
  • This study investigates the mechanical behavior on trough rib to crossbeam joint in orthotropic steel plate decks, specially emphasizing on the effect of diaphragm inside trough rib on the fatigue behavior of slit by static and fatigue tests. In particular, the effects of diaphragm on in-plane stress and out-of-plane stress, stress concentration, propagation of fatigue cracks at the silt are studied. With the result of experiment and numerical analysis, we have estimated the fatigue strength using the nominal stress and hot-sport stress. The details with diaphragm have occurred about 50% stress reduction at trough rib part of trough rib to crossbeam joint than the detail without diaphragm, however, the lower parts of crossbeam have occurred much more stress. Initial crack size or slit have an considerable influence on the propagation of fatigue cracks due to V-notch. The fatigue strength category of the details without diaphragm has higher value than fatigue limit, whereas that of the details with diaphragm is estimated lower than fatigue limit.

  • PDF

Development of Multiple Layers Insulation for SOFC (SOFC를 위한 고온용 적층단열재 개발)

  • CHOI, CHONGGUN;HWANG, SEUNG-SIK;CHOI, GYU-HONG
    • Journal of Hydrogen and New Energy
    • /
    • v.29 no.4
    • /
    • pp.386-392
    • /
    • 2018
  • Fuel cells are known as eco - friendly energy facilities that can use heat energy and electric energy at the same time. Fuel cells are classified according to the temperature and material used, and solid oxide fuel cell (SOFC) is relatively high temperature ($700-800^{\circ}C$). SOFC requires a hot box consisting of a high temperature stack, a reformer, a burner, and the heat exchangers in order to use energy efficiently. The hot box needs to maintain heat insulation performance at high temperature to reduce heat loss. However, Fibrous insulation, which is widely used, needs to be improved because it has a disadvantage that the thermal conductivity is rapidly increased due to the increase of temperature. Therefore, this study was carried out to develop a thermal insulation, which is applied to multiple layers insulation (MLI) technic, that can be used under SOFC operating conditions and prevent a drastic drop in thermal conductivity at high temperature. The developed insulation is consist of a thermally conductive material, a spacer, and a reflective plate. The thermal conductivity of the insulation was measured by in the thermal conductivity measuring device at high temperature range. As a result, it was confirmed that the developed layers insulation have an good thermal conductivity (0.116 W/mK) than fibrous insulation (0.24 W/mK) as a radiation shielding effect at a high temperature of 1,173 K.