• 제목/요약/키워드: Hot gas system

검색결과 377건 처리시간 0.024초

슬릿과 스월베인이 Gun식 가스버너의 주 유동장에 미치는 영향 (Effects of Slits and Swirl Vanes on the Main Flow Fields of a Gun-Type Gas Swirl Burner)

  • 김장권;정규조
    • 동력기계공학회지
    • /
    • 제6권4호
    • /
    • pp.23-29
    • /
    • 2002
  • This paper is studied to investigate the effect of slits and swirl vanes on the main flow fields of a gun-type gas burner through X-Y plane and Y-Z plane respectively by using X-probe from hot-wire anemometer system. This experiment was carried out with flow rate $450{\ell}/min$ in respective burner models installed in the test section of a subsonic wind tunnel. The burner models with only slits and only swirl vanes respectively were made by modifying original gun-type gas burner. The fast jet flow spurted from slits played a role such as an air-curtain because it encircled rotational flow by swirl vanes and drives mixed main flow to axial direction. As a result, the gun-type gas burner had a wider flow range up to about Y/R=1.5 deviated from slits and maintains a comparatively large velocity in the central part of burner within the range of about X/R=2.5. Therefore, it was very desirable that swirl vanes were installed within slits in gun-type gas burner in order to control the main flow fields effectively.

  • PDF

Operation optimization of auxiliary electric boiler system in HTR-PM nuclear power plant

  • Du, Xingxuan;Ma, Xiaolong;Liu, Junfeng;Wu, Shifa;Wang, Pengfei
    • Nuclear Engineering and Technology
    • /
    • 제54권8호
    • /
    • pp.2840-2851
    • /
    • 2022
  • Electric boilers (EBs) are the backup steam source for the auxiliary steam system of high-temperature gas-cooled reactor nuclear power plants. When the plant is in normal operations, the EB is always in hot standby status. However, the current hot standby operation strategy has problems of slow response, high power consumption, and long operation time. To solve these problems, this study focuses on the optimization of hot standby operations for the EB system. First, mathematical models of an electrode immersion EB and its accompanying deaerator were established. Then, a control simulation platform of the EB system was developed in MATLAB/Simulink implementing the established mathematical models and corresponding control systems. Finally, two optimization strategies for the EB hot standby operation were proposed, followed by dynamic simulations of the EB system transient from hot standby to normal operations. The results indicate that the proposed optimization strategies can significantly speed up the transient response of the EB system from hot standby to normal operations and reduce the power consumption in hot standby operations, improving the dynamic performance and economy of the system.

고온부 냉각을 위한 스월챔버내의 유동 및 열전달 해석 (Analysis of Flow and Heat Transfer in Swirl Chamber for Cooling in Hot Section)

  • 이강엽;김형모;한영민;이수용
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2002년도 춘계 학술대회논문집
    • /
    • pp.71-78
    • /
    • 2002
  • All modem, aerospace gas turbines must operate with hot stage gas temperature several hundreds of degrees hotter than the melting temperatures of the materials used in their construction. Complicated cooling schemes need to be employed in the combustor walls and In the high pressure turbine stages. Internal passages are cast or machined into the hot sections of aero-gas turbine engines and air from the compressor is used for cooling. In many cases, the cooling system is engineered to utilize jets of high velocity air, which impinge on the internal surfaces of the components. They are divided by Impinging cooling method and Vortex cooling method. Specially, Research of new cooling system(Vortex cooling method) that overcome inefficiency of film cooling and limitation of space. The focus of new cooling system that improve greatly cooling efficiency using quantity's cooling air which is less is set in surface heat transfer elevation. Therefore, In this study, the numerical analysis have been performed for characteristic of flow and thermal in the swirl chamber and compared with the flow field measurement by LDV. especially, for understanding of high heat transfer efficiency in vicinity of wall. we considered flow structure and mechanism of vortex and heat transfer characteristic in variation of Reynolds number.

  • PDF

공동주택용 태양열원 급탕시스템의 운전성능 연구 (A Study on the Operating Performance of Solar Assisted Hot Water System for Apartment Houses)

  • 이윤규;황인주
    • 설비공학논문집
    • /
    • 제15권11호
    • /
    • pp.928-936
    • /
    • 2003
  • In the present study, feasibility investigation on the solar assisted hot water supply system for apartment houses was carried out by the review of service facility and heat load pattern. Also analysis and experiment of the small sized system model were performed. This hybrid system are consists of solar collector, heat storage tank, controller, and gas boiler using LPG as a secondary heat source. The analytical results showed a good agreement with experimental data. We found that this hybrid system could reduce the energy cost by 30% for hot water compared to typical boiler system in the apartment houses. Also we showed that this model could be used for the energy and economic analysis of the hybrid system.

1kW급 고체산화물 연료전지 발전시스템 자열운전 (Self-sustainable Operation of a 1kW class SOFC System)

  • 이태희;최진혁;박태성;유영성
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.57-60
    • /
    • 2008
  • KEPRI has studied planar type SOFC stacks using anode-supported single cells and kW class co-generation systems for residential power generation. A 1kW class SOFC system consisted of a hot box part, a cold BOP part and a water reservoir. A hot box part contains a SOFC stack made up of 48 single cells and ferritic stainless steel interconnectors, a fuel reformer, a catalytic combustor and heat exchangers. Thermal management and insulation system were especially designed for self-sustainable operation. A cold BOP part was composed of blowers, pumps, a water trap and system control units. When a 1kW class SOFC system was operated at $750^{\circ}C$ with hydrogen after pre-treatment process, the stack power was 1.2kW at 30 A and 1.6kW at 50A. Turning off an electric furnace, the SOFC system was operated using hydrogen and city gas without any external heat source. Under self-sustainable operation conditions, the stack power was about 1.3kW with hydrogen and 1.2kW with city gas respectively. The system also recuperated heat of about 1.1kW by making hot water.

  • PDF

공동주택 에너지 소비 경향 분석에 관한 연구 (The Analysis of Energy Consumption Characteristics of the Apartment)

  • 이현정;박선효;배상환;이병석;김양섭
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.305-310
    • /
    • 2012
  • In 2009, The Ministry of Land, Transport and Maritime Affairs, Korea opens apartment maintenance fee to public in "Apartment Management Info System". The high energy consumption component of apartment, which is hot water, water, electricity and heating, is released to public on this system. Through this system, apartment energy consumption and greenhouse gas emissions data can be compiled and expected to be accurately analyzed. Energy consumption and greenhouse gas emissions statistics of the apartment are collected being made to reduce energy and gas emissions. However, The accurate survey of energy consumption trends have not been accomplished. The energy consumption and greenhouse gas emissions survey in Apartment should be made first in order to reduce energy consumption. and then the correlation factors analysis which is affecting energy consumption is required. The purpose of this study is to analyze energy consumption characteristics of apartment in Bundann-gu, Seongnam, Korea in monthly, unit area and building built year basis. And then the research can be used as the basis of policy to Reduce energy consumption and greenhouse gas emissions.

  • PDF

고온정제 온도에 따른 IGCC 시스템 성능 영향 분석 (The analysis of the effect on the temperature of Hot Gas Clean-Up for IGCC system)

  • 서석빈;김종진;이윤경;안달홍
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1999년도 추계 학술발표회 논문집
    • /
    • pp.47-51
    • /
    • 1999
  • 차세대 석탄가스화복합발전(Integrated Gasification Combined Cycle; IGCC)으로써 고온정제(Hot Gas Clean-up; HGCU)는 고온고압의 석탄가스 중에 있는 불순물을 고온고압에서 제거하는 기술이다. 현재 이 기술에 대한 연구가 국내외적으로 활발히 이루어지고 있으며 특히 미국 에너지성에서는 2000년까지 플랜트 효율 45%의 건식 고온정제를 채용한 IGCC 시스템을 개발 중에 있으며 나아가 목표 효율 50% 이상으로 건식 고온 정제뿐 아니라 차세대 가스터빈을 채용한 시스템으로 2010년 개발을 목표로 하고 있다.(중략)

  • PDF

콘덴싱 가스보일러시스템의 제어 알고리즘 개발을 위한 효과적인 동적모델 (Effective Dynamic Models for the Development of Control Algorithms of a Condensing Gas Boiler System)

  • 한도영;김성학
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.34-39
    • /
    • 2007
  • Condensing gas boiler units may make a big role for the reduction of energy consumption in heating industries. In order to decrease the energy consumption of a condensing gas boiler unit, the effective operations and controls of the system are necessary. In this study, mathematical models of a condensing gas boiler system were developed and programmed in order to predict dynamic behaviors of the system. These include dynamic models for a blower, a gas valve, a pump, a burner, a boiler heat exchanger, and a hot water heat exchanger. Control algorithms for the control of a gas valve, a blower, and a pump were also assumed. Simulation results showed good predictions of the dynamic phenomena of a boiler system. Therefore, the simulation program developed for this study may be effectively used for the development of control algorithms of the boiler system.

  • PDF

수소가스 감지용 가연성 가스센서 제작을 위한 요소기술 개발 (Development of Core Technologies for Integrating Combustible Hydrogen Gas Sensor)

  • 윤의중;박형식;이석태;박노경
    • 한국전기전자재료학회논문지
    • /
    • 제20권3호
    • /
    • pp.228-233
    • /
    • 2007
  • Core technologies for integrating hydrogen gas sensor were investigated. In this study, the thermally isolated micro-hot-plate with areas of $100{\times}100-260{\times}260{\mu}m^2$ was fabricated by utilizing surface micromachining technique that provides better manufacturing yield than bulk micromachining counterpart. The optimum design of the sensor was peformed by analyzing the thermal profile of the structure obtained from a ANSYS simulator. The 400-nm-thick polysilicon films doped with phosphorus, the 300-nm-thick aluminum films, and the 200-nm-thick $SnO_2$(or ZnO)films were used as the micro-heater material, the temperature sensor material, and the gas sensitive material, respectively. The experimental results show that the developed gas sensors can detect $H_2$ concentration as low as 1 ppm.

Experimental Investigation on the Turbulence Augmentation of a Gun-type Gas Burner by Slits and Swirl Vanes

  • Kim, Jang-kweon
    • Journal of Mechanical Science and Technology
    • /
    • 제18권10호
    • /
    • pp.1819-1828
    • /
    • 2004
  • The purpose of this paper is to investigate the effects of slits and swirl vanes on the turbulence augmentation in the flow fields of a gun-type gas burner using an X-type hot-wire probe. The gun-type gas burner adopted in this study is composed of eight slits and swirl vanes located on the surface of an inclined baffle plate. Experiment was carried out at a flow rate of 450 ι/min in burner model installed in the test section of subsonic wind tunnel. Swirl vanes playa role diffusing main flow more remarkably toward the radial direction than axial one, but slits show a reverse feature. Consequently, both slits and swirl vanes remarkably increase turbulence intensity in the whole range of a gun-type gas burner with a cone-type baffle plate.