• Title/Summary/Keyword: Hospital medical devices

Search Result 303, Processing Time 0.027 seconds

New techniques for wound management: A systematic review of their role in the management of chronic wounds

  • Bekara, Farid;Vitse, Julian;Fluieraru, Sergiu;Masson, Raphael;De Runz, Antoine;Georgescu, Vera;Bressy, Guillaume;Labbe, Jean Louis;Chaput, Benoit;Herlin, Christian
    • Archives of Plastic Surgery
    • /
    • v.45 no.2
    • /
    • pp.102-110
    • /
    • 2018
  • Debridement is a crucial component of wound management. Recent technologies such as hydrosurgery (Versajet), ultrasound therapy (the MIST therapy device), or plasma-mediated bipolar radio-frequency ablation therapy (Coblation) seem to represent interesting alternatives for wound debridement. The purpose of this systematic review was to describe, evaluate, and compare these three recently developed methods for the management of chronic wounds. In January 2016, an electronic database search was conducted of MEDLINE, PubMed Central, and Embase for articles concerning these three innovative methods for the management of chronic wounds. A total of 389 references were identified by our search strategy, and 15 articles were included. We extracted data regarding the number and age of patients, indications, operating time, number of procedures, costs, wound healing time, decrease in exudation, perioperative blood loss, bacterial load, and the occurrence of complications. The 15 articles included studies that involved 563 patients who underwent hydrosurgery (7 studies), ultrasound therapy (6 studies), or Coblation (2 studies). Six randomized controlled trials were included that compared the use of a scalpel or curette to hydrosurgery (2 studies) or ultrasound therapy (6 studies). Hydrosurgery, in addition to being a very precise and selective tool, allows significantly faster debridement. Ultrasound therapy provides a significant reduction of exudation, and improves the wound healing time. No comparative study dedicated to Coblation was identified. Despite the obvious clinical interest of the topic, our review of the current literature revealed a lack of prospective randomized studies comparing these devices with each other or with standard techniques, particularly for Coblation and hydrosurgery.

The Study on Organization, Infection Controller, Patient Infection Control of Dental Clinic in Certain Areas (일부지역 치과의 기관, 감염관리자, 환자의 감염관리에 관한 연구)

  • Choi, Du-Ri;Kim, Seol-Hee
    • Journal of dental hygiene science
    • /
    • v.15 no.4
    • /
    • pp.399-406
    • /
    • 2015
  • The purpose of this study was to investigate the performance of dental infection control. This survey was performed on 158 of the dental hygienist in certain areas. The research was performed using a self-reported questionnaire and interview method from June to July, 2014. The collected data was analyzed by PASW Statistics ver. 18.0. Guideline of infection management, infection controller, regular infection control training, Sterilization of the handpiece/per head resulted 57~74% for dental hospital. It was higher than 13~20% for dental clinics (p<0.05). Infection control guidelines and vaccination recognition of dental were more performed in dental hospital. Patient's hand hygiene performed, tooth brushing before treatment, cross infection educational experience was less than 20%, research cooperation of medical history was over 90% (p<0.05). Performing rate of the dental hospital workers were investigated higher in protective personal devices, infection control of treatment room. A correlation analysis about institutional support, infection control of dental hygienists, patients with infection control cooperation showed a positive correlation statistically significant. Infection control can be enhanced when the medical staff, the patient, the organization combined cognitive and practice. Dental hygienist is required to recognize and practice the infection control guidelines through continuing education.

The Acceptance Testing of 5 Mega Pixels Primary Electronic Display Devices and the Study of Quality Control Guideline Suitable for Domestic Circumstance (5 Mega 화소 진단용 전자표시장치 인수검사 및 국내 실정에 적합한 정도관리 가이드라인 연구)

  • Jung, Hai-Jo;Kim, Hee-Joung;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.18 no.2
    • /
    • pp.98-106
    • /
    • 2007
  • In June 2005, Yonsei University Medical Center, Severance Hospital upgraded a full-PACS system by adding twenty (5 mega pixels) Totoku ME511L flat panel LCD display devices for diagnostic interpretation purposes. Here we report upon the quantitative (or visual) acceptance testing of the twenty Totoku ME511L display devices for reflection, luminance response, luminance spatial dependency, resolution, noise, veiling glare, and display chromaticity based on AAPM TG 18 report. The tools used in the tests included a telescopic photometer, which was used as a colorimeter, illuminance meter, light sources for reflection assessment, light-blocking devices, and digital TG18 test patterns. For selected 8 flat panel displays, mean diffuse reflection coefficient ($R_d$) was $0.019{\pm}0.02sr^{-1}$. In the luminance response test, luminance ratio (LR), maximum luminance difference ($L_{max}$), and deviation of contrast response were $550{\pm}100,\;2.0{\pm}1.9%\;and\;5.8{\pm}1.8%$, respectively. In the luminance uniformity test, maximum luminance deviation was $14.3{\pm}5.5%$ for the 10% luminance of the TG18-UNL10 test pattern. In the resolution test with luminance measurement method, percent luminance (${\Dalta}L$) at the center was $0.94{\pm}0.64%$. In all cases of noise testing, rectangular target In every square in the three quadrants was visible and all 15 targets except the smallest one in the every corner pattern and the center pattern. The glare ratio (GR) was $12,346{\pm}1,995$. The color uniformity, (u',v'), was $0.0025{\pm}0.0008$. Also, the research results of qualify control guideline of primary disply devices suitable for domestic circumstance are presented All test results are in-line with the criteria recommended by AAPM TG18 report and are thus fully acceptable for diagnostic image interpretation. As a result, the acceptance testing schedule described provides not only an acceptance standard but also guidelines for quality control, optimized viewing conditions, and a means for determining the upgrading time of LCD display devices for diagnostic interpretation.

  • PDF

Effect of Human Implantable Medical Devices on Dose and Image Quality during Chest Radiography using Automatic Exposure Control (자동노출제어를 적용한 흉부 방사선 검사 시 인체 이식형 의료기기가 선량과 화질에 미치는 영향)

  • Kang-Min Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.3
    • /
    • pp.257-265
    • /
    • 2024
  • In this study, we applied AEC(Auto Exposure Control), which is used in many chest examinations, to evaluate whether medical devices inserted into the body affect the dose and image quality of chest images. After attaching three HIMD(Human implantable medical devices) to the ion chamber, the Monte Carlo methodology-based program PCXMC(PC Program for X-ray Monte Carlo) 2.0 was applied to measure the effective dose by inputting the DAP(Dose Ares Product) value derived from the Pacemaker and CRT and Chemoport Additionally, to evaluate image quality, we set three regions of interest and one noise region on the chest and measured SNR and CNR. The final study results showed significant differences in DAP and Effective dose. There was a significant difference between Pacemaker and CRT when AEC was applied and not applied. (p<0.05) When applied, the dose increased by 37% for Pacemaekr and 52% for CRT. Chemoport showed a 10% increase in effective dose depending on whether AEC was applied, but there was no significant difference. (p>0.05) In the image quality evaluation, there was no significant difference in image quality between all HIMD insertions and AEC applied or not. (p>0.05) Therefore, when the HIMD was inserted into the chest during a chest x ray and overlapped with the ion chamber sensor, the effective dose increased, and there was no difference in image quality even at a low dose without AEC. Therefore, when performing a chest X-ray examination of a patient with a HIMD inserted, it is considered that performing the examination without applying AEC is a method that can be considered to reduce the patient's radiation exposure.

Maternal and neonatal outcomes in Korean women with type 2 diabetes

  • Jang, Hye-Jung;Kim, Hee-Sook;Kim, Sung-Hoon
    • The Korean journal of internal medicine
    • /
    • v.33 no.6
    • /
    • pp.1143-1149
    • /
    • 2018
  • Background/Aims: The purpose of this study was to compare maternal and neonatal outcomes in Korean women with type 2 diabetes and nondiabetic controls. Methods: We performed a retrospective survey of 200 pregnancies in women with type 2 diabetes (n = 100) and nondiabetic controls (n = 100) who delivered from 2003 to 2010 at Cheil General Hospital & Women's Healthcare Center, Korea. We compared maternal characteristics as well as maternal and neonatal outcomes between groups matched by age, pre-pregnancy weight, body mass index, parity, and gestational age at delivery. Results: The number of infants that were small for gestational age and the rate of major congenital malformations were not significantly different. However, women with type 2 diabetes showed a slightly higher risk for primary caesarean section (35.0% vs. 18.0%, p = 0.006) as well as pre-eclampsia (10.0% vs. 2.0%, p = 0.017), infections during pregnancy (26.0% vs. 2.0%, p < 0.001), neonatal weight ($3,370{\pm}552.0$ vs. $3,196{\pm}543.3$, p = 0.025), large for gestational age (22.0% vs. 9.0%, p = 0.011), and macrosomia (15.0% vs. 5.0%, p = 0.018) compared to nondiabetic controls. Conclusions: Maternal and neonatal outcomes for women with type 2 diabetes were worse than those for nondiabetic controls. Diabetic women have a higher risk for primary caesarean section, pre-eclampsia, infections during pregnancy, large neonatal birth weight, large for gestational age, and macrosomia.

A Design of Key Generation and Communication for Device Access Control based on Smart Health Care (스마트 헬스케어 기반의 디바이스 접근제어를 위한 키 생성 및 통신기법 설계)

  • Min, So-Yeon;Lee, Kwang-Hyong;Jin, Byung-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.11
    • /
    • pp.746-754
    • /
    • 2016
  • Smart healthcare systems, a convergent industry based on information and communications technologies (ICT), has emerged from personal health management to remote medical treatment as a distinguished industry. The smart healthcare environment provides technology to deliver vital information, such as pulse rate, body temperature, health status, and so on, from wearable devices to the hospital network where the physician is located. However, since it deals with the patient's personal medical information, there is a security issue for personal information management, and the system may be vulnerable to cyber-attacks in wireless networks. Therefore, this study focuses on a key-development and device-management system to generate keys in the smart environment to safely manage devices. The protocol is designed to provide safe communications with the generated key and to manage the devices, as well as the generated key. The security level is analyzed against attack methods that may occur in a healthcare environment, and it was compared with existing key methods and coding capabilities. In the performance evaluation, we analyze the security against attacks occurring in a smart healthcare environment, and the security and efficiency of the existing key encryption method, and we confirmed an improvement of about 15%, compared to the existing cipher systems.

A Study on Perceived Discomfort in Patients Following Cardiac Catheterization (심도자 검사 환자의 불편감에 관한 연구)

  • 이은자
    • Journal of Korean Academy of Nursing
    • /
    • v.25 no.1
    • /
    • pp.124-140
    • /
    • 1995
  • Cardiac cathererization has become a routine diagnostic procedure indicated for evaluation of a wide varity of cardiac conditions. Patients are admitted to the coronary care unit after cardiac catheterization. These conscious patients report feeling uncomfortable in the CCU, but no studies have been done on the effects of bed rest, sand bags on the femoral puncture site and restricted mobility for 4 to 12 hours or longer postprocedure. The main objective of this thesis is to provide basic data to nursing on interventions which de-crease the uncomfortableness experienced by patients in the CCU following cardiac catheterization. In this phenomenological study, the various discomforts felt by the patients were collected and classified. The study subjects were a convenience sample of 29 patients who were admitted to the CCU of a general hospital in Inchon following cardiac catheterization. They were conscious, so they were able to communicate without difficulty. The data were collected over an U days period from July 21, to October 14, 1994. The subjects were interviewed using unstructured open questions and the interviews were tape recorded with the patient's permission The data were analyzed using the Van Kaams phenomenological method. Reliability and validity were exammed by two professor of nursing science, one head nurse, one staff nurse and one cardiologist. The results of the study are summarized as follows ; 1. The 129 descriptive statements by the postcardiac catheterization patients of discomfort were organized into 19 themes. 2. The 19 themes were divided into 3 categories ; physical, psychological, and environmental aspects. 3. The problems concerning the physical aspect were the discomfort of restriction of movement, dysuria, medical devices, pain in the puncture site, symptom is related to the procedure of cardiac catheterization, headache and dizziness, leg painand tingling sensation, and chest pain. The problems concerning the psychological aspect were regret resulting from dependency, economic burden, dissatisfaction with medical personnel, dissatisfaction with medical service system, anxiety about the result of the procedure, concern about the prognosis, loneliness, and concern over treatment procedure. The problems concerning the environmental aspect were influence from neighboring patients, noise, and maladaptation to environmental change. The necessity for holistic care which satisfies physical, psychological, and environmental need must be emphasized in order to solve these discomforts.

  • PDF

Study on the Transmission of Medical Information using Bluetooth Technology (블루투스를 이용한 의료정보 신호의 전송에 관한 연구)

  • 엄정규;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.05a
    • /
    • pp.520-523
    • /
    • 2001
  • In this paper, a system that transmits ECG signals which get from hand baggage ECG is implemented by using Bluetooth technology. Bluetooth technology is a close range wireless communication used wireless frequency 2.4GHZ bandwidth. This technology consumes very small power and provides high reliability also self error correction with high speed frequency hopping. Because every device which uses Bluetooth protocol can communicate each other. These can connect between the system implemented and any devices such as mobile telephone with Bluetooth module, notebook, and the personal mobile device. Also, the paper proposes capability of transmission to the sever of hospital through each type of wireless communication device that acquired medical information signals in mobile medical machine. The system consists of hardware parts with Bluetooth module and host part, and software parts with bluetooth protocol stacks. The host precesses a connection with other device and transmits ECG signals with bluetooth frequency hopping sequence.

  • PDF

Study on the Transmission of Medical Information using Bluetooth Technology (블루투스를 이용한 의료정보 신호의 전송에 관한 연구)

  • 엄정규;김영길
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.2
    • /
    • pp.297-301
    • /
    • 2001
  • In this paper, a system that transmits ECG signals which get from hand baggage ECG is implemented by using Bluetooth technology. Bluetooth technology is a close range wireless communication used wireless frequency 2.4GHz bandwidth. This technology consumes very small power and provides high reliability also self error correction with high speed frequency hopping. Because every device which uses Bluetooth protocol can communicate each other. These can connect between the system implemented and any devices such as mobile telephone with Bluetooth module, notebook, and the personal mobile device. Also, the paper proposes capability of transmission to the sever of hospital through each type of wireless communication device that acquired medical information signals in mobile medical machine. The system consists of hardware parts with Bluetooth module and host part, and software parts with blutooth protocol stacks. The host precesses a connection with other device and transmits ECG signals with bluetooth frequency hopping sequence.

  • PDF

A study on Actual Condition and Interfererence of Electromagnetic Fields inside of The Hospital (I) (의료기관내 전자파환경 실태와 그 영향 (I))

  • Lee, Jun-Ha;Shin, Hyun-Jin;Yoo, Heum
    • Progress in Medical Physics
    • /
    • v.8 no.1
    • /
    • pp.53-67
    • /
    • 1997
  • General hospitals have being under the influence of various and specific environment of electromagnetic field. The factors are development of medical electric equipment and device with enlarged functional demands, in high power and multi-frequency. It has all of both faces, EMI(electromagnetic interference) and EMS(electromagnetic susceptibility). In additional, expansion of personal communication system(cellular phone) has many unreliable factor of using time and area, making noise of electromagnetic fields. We studied actual conditions of EMI in the medical site, where is numerous medical equipment, especially central operation room and ICU(intensive care unit), AKR(artificial kidney room : hemo-dialysis unit), etc. The influence, most of medical equipments made electromagnetic nosie has various factors in its band of frequency, harmonics and strength. In the experimental use of electro-surgical unit and cellular phone, noticeable and considerable noise of eletromagnetic fields were measured. All of that can make trouble and errors on the steadiness of bioelectrical devices. In conclusion, It is necessary to reconsiderations of reallocating EMI source vs. EMS factor, and set to definite forbiding area of using cellular phone. For maintenance of steady normal conditions, in spite of existing any other legal standards of safty level, it need considering all of alternative electromagnetic situations on a case-by-case basis.

  • PDF