• Title/Summary/Keyword: Hospital building

Search Result 346, Processing Time 0.022 seconds

The Energy Performance & Economy Efficiency Evaluation of Micro Gas Turbine Installed in Hospital (대형병원 건물에 마이크로 가스터빈 적용을 위한 에너지성능 및 경제성 평가)

  • Kim, Byoung-Soo;Hong, Won-Pyo
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.5
    • /
    • pp.8-13
    • /
    • 2009
  • Feasibilities of the application of a micro gas turbine cogeneration system to a large size hospital building are studied by estimating energy demands and supplies. The energy demand for electricity is estimated by surveying and sorting the consumption records for various equipment and devices. The cooling heating, and hot water demands are further refined with TRNSYS and ESP-r to generate load profiles for the subsequent operation simulations. The operation of the suggested cogeneration system in conjunction with the load data is simulated for a time span of a year to predict energy consumption and gain profile. The simulation revealed that the thermal efficiency of the gas turbine is about 30% and it supplies 60% of the electricity required by the building. The recovered heat can meet 56% of total heating load and 67% of cooling, and the combined efficiency reaches up to 70%.

Research on Traditional Chinese Medicine harmonising two approaches

  • Chung, Leung Ping;Wai, Lau Tai;Sang, Woo Kam
    • Advances in Traditional Medicine
    • /
    • v.8 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • While full recognition of the practical value of Traditional Chinese Medicine is being endorsed, the current stand on the research methodology of this field should be worked out. Since modern medicine has already developed a logical system of research methodology basing on the principles of deduction, any research on any system of medicine need to take reference to what is most popularly used and commonly recommended. The best way to approach research on Chinese Medicine, therefore, would be one that would take full reference to the methodology being used in modern medicine, while at the same time respecting the traditional approach. This would enable traditional medicine to be elevated to the level of general modern recognition. Nevertheless, innate problems in traditional medicine are making its research difficult. The problems lie in difficulties to achieve uniform herb supply, principles of randomization and placebo arrangements, uncertain chemical structures and toxicology etc. A practical approach centered on carefully planned evidence-based clinical trials, with parallel studies on biological activities and herb authentication is being recommended.

DESIGN, CONSTRUCTION AND ACOUSTIC PERFORMANCE OF A SOUND-POOOF ENCLOSURE FOR DIESEL GENERATOR-SET

  • Bansal, A.S.
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1994.06a
    • /
    • pp.662-667
    • /
    • 1994
  • This paper presents the design and construction details of a soundproof enclosure for housing 20 KVA diesel generator-set. As the generator had to be installed close to the hospital building, it was desirable to reduce the transmission of noise by housing the generator in such an enclosure. The diesel engine being an air cooled one, it was essential to supply fresh air into the enclosure for its cooling. Forced inflow of air is provided through an inlet duct located in such a way that the incoming fresh air is thrown close to the inlet of cooling fan of the engine. The high velocity air stream, which heats up while passing over the engine head, escapes to the atmosphere through a rectangular outlet duct with enlarges inlet that receives hot air from the engine. The air ducts were designed specially and have been provided with acoustic lining for sound absorption. The masonary enclosure has been provided with double glazed fixed windows and double doors. The exhaust pipe of the engine fitted with a muffler has been taken out through the enclosure wall facing away from the hospital. Acoustic performance studies conducted in terms of attenuation provided by the enclosure at different frequencies have also been presented and discussed. The noise control measures adopted for building the sound-proof enclosure have been found to be quite effective as the noise levels inside the hospital building are now within the acceptable limits.

  • PDF

Seismic retrofit of a steel-reinforced concrete hospital building using continuous energy-dissipative steel columns

  • Massimiliano Ferraioli;Biagio Laurenza;Angelo Lavino;Ciro Frattolillo;Gianfranco De Matteis
    • Steel and Composite Structures
    • /
    • v.47 no.4
    • /
    • pp.467-488
    • /
    • 2023
  • Seismic retrofit of an existing steel-reinforced concrete hospital building that features innovative use of a continuous energy-dissipative steel column (CEDC) system is presented in this paper. The special system has been adopted to provide an efficient solution taking into account the difficulties of applying traditional intervention techniques to minimize the impact on architectural functionality and avoid the loss of building function and evacuation during the retrofit implementation. The lateral stiffness and strength of the CEDC system were defined based on the geometric and mechanical properties of the steel strip dampers. The hysteretic behavior under cyclic loadings was defined using a simplified numerical model. Its effectiveness was validated by comparing the results of full-scale experimental data available from the literature. All the main design considerations of the retrofitting plan are described in detail. The effectiveness of the proposed retrofitting system was demonstrated by nonlinear time-history analyses under different sets of earthquake-strong ground motions. The analysis results show that the CEDC system is effective in controlling the deformation pattern and significantly reducing damage to the existing structure during major earthquakes.

Empirical Research on Application of ICT for Reduction of Energy Consumption of Hospital Buildings (ICT를 활용한 병원건물의 에너지 절감방안 연구)

  • Lee, Junghwan;Han, Youngdo;Kim, Dongwook
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.1
    • /
    • pp.422-430
    • /
    • 2018
  • Increase in oil prices and building energy consumption has been a great burden for Korea which has significant energy dependence on foreign energy sources. In this context, reduction of building energy consumption, which comprises 40% of total energy consumption, is a very important issue. This research therefore empirically analyzed a hospital "P" that implemented ICT-based energy consumption and cost reduction initiative. The hospital first replaced existing water absorber for heating/cooling air and boiler for heating water with water heat storage heat pump system. This was accompanied by subscribing to different electricity price plans to maximize cost reduction. Secondly, the hospital additionally applied ICT-based optimized control algorithm that considers surrounding factors (external temperature, changes in energy demand). The analysis of these mechanisms indicate that the ICT-based energy consumption and cost reduction initiative for hospitals can reduce energy consumption by 53.6% with replacement of low-efficiency equipment and additionally by 18.2% with optimized control algorithm. The mechanisms will provide energy consumption reduction opportunities for other hospitals and buildings with high energy consumption.

Correlation Between Meteorological Factors and Hospital Power Consumption (기상요인과 병원 전력사용량의 상관관계)

  • Kim, Jang-Mook;Cho, Jung-Hwan;Kim, Byul
    • Journal of Digital Convergence
    • /
    • v.14 no.6
    • /
    • pp.457-466
    • /
    • 2016
  • To achieve eco-friendly hospitals it is necessary to empirically verify the effect of meteorological factors on the power consumption of the hospital. Using daily meteorological big data from 2009 to 2013, we studied the weather conditions impact to power consumption and analyzed the patterns of power consumption of two hospitals. R analysis revealed that temperature among the meteorological factors had the greatest impact on the hospital power consumption, and was a significant factor regardless of hospital size. The pattern of hospital power consumption differed considerably depending on the hospital size. The larger hospital had a linear pattern of power consumption and the smaller hospital had a quadratic nonlinear pattern. A typical pattern of increasing power consumption during a hot summer and a cold winter was evident for both hospitals. The results of this study suggest that a hospital's functional specificity and meteorological factors should be considered to improve energy savings and eco-friendly building.

A Study on Environment-friendliness in Tokyo Regional Hospitals - Focused on the Sustainable Site and Transportation (일본 도쿄 지역 병원의 친환경성 분석 연구 - 토지이용 및 교통부분을 중심으로)

  • Lim, Yeonghwan
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.21 no.3
    • /
    • pp.57-67
    • /
    • 2015
  • Purpose: As the concerns for the environment are gradually prioritized, increasing interests of environment-friendly buildings are drawn. Numerous researches about healthcare buildings have been performed however, they were mainly focused on convenience or healing condition for medical treatments. The hospitals consume energy and generate $CO_2$ as twice as the residential or commercial buildings do. Various green building certification systems are globally arranged. But, it isn't easy to find certification criteria for the green hospital besides the US and UK's ones which are specially designed to evaluate environment-friendly medical buildings(Lim&Yoo, 2010). Methods: In this study, we investigates current conditions of Tokyo Regional hospitals in environment-friendly standpoint and also investigates the foreign certification criteria and systems for the green healthcare building and finds the possibility to apply them to Korean one. Results: Through this study, we found that the Tokyo regional hospitals can be environmentally improved by management plans and programs. Implications: Based on this analysis, Korean Green Building Certification for healthcare facilities will be developed in near future.

A Study on the Remodeling of General Hospitals in Consideration of Healing Environmental Elements - focused on the case of a hospital - (치유환경 요소를 고려한 종합병원의 리모델링 사례연구 - A병원 사례를 중심으로 -)

  • Lim, Jin Woo;Park, Jae Seung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.10 no.1
    • /
    • pp.7-17
    • /
    • 2004
  • This study aims to propose planning guides and general suggestions in the remodeling of general hospitals. Among the many goals in the hospital remodeling, this study focuses on the enhancing the 'healing environment' to existing building. Accordingly this study analyzes design criteria for 'healing environment' through the case study of 'A' hospital which has been remodeled recently, and compares those criteria with actual execution.

  • PDF

A Study on the Floor Area Characteristics of the University School Building Facilities by the Campus Characteristics in 2001-2003 (캠퍼스 특성별 대학교사시설의 면적특성 - 2001년$\sim$2003년의 기간을 중심으로 -)

  • Kim, Jong-Seok
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.13 no.3
    • /
    • pp.48-55
    • /
    • 2006
  • This paper considered the situation of the school building facilities in the university classified by the campus characteristics. Data were collected from 224 universities campus of 180 4 year colleges. The results are as follows: 1) The floor area of school building facilities increases continuously in 2001-2003 in the campuses studied. The floor area of school building facilities per 1 student increase $15.85m^2$ in 2001, $17.62m^2$ in 2002, and $17.79m^2$ in 2003. 2) The floor area of school building facilities is distributed widely, also the floor area of school building facilities is below $130,000m^2$ and the floor area per 1 student is below $23m^2$ in 75% of the campuses studied. 3) The floor area of school building facilities per 1 student increases $16.07m^2$ in 2001, $17.41m^2$ in 2002 and $17.62m^2$ in 2003. 4) The floor area of school building facilities per 1 student is large but tends to decrease every year in the university of education. Medical, arts and physical type campus has the large floor area per 1 student and the distribution of area is wide owing to the campus having a hospital. The floor area per 1 student is large and the distribution of area is wide in the sub campus.

Case Study on the Building Organization of Medibio Research Laboratory Facilities in Research-driven Hospital (연구중심병원 의생명연구원의 실험실 구성 사례 조사)

  • Kim, Young-Aee
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.11
    • /
    • pp.95-104
    • /
    • 2018
  • Healthcare technology has been growing and fostering cooperation between industry, university and hospitals as growth engines in korea. So, the medibio research institutes in hospital have been constructed to promote research and industrialization centering on healthcare technology. The purpose of this study is to investigate the cases of research institutes in hospitals, and search the characteristics of building organization of medibio research laboratory facilities. Case study is investigated by floor plan, homepage and site visits about five research institutes selected in research-driven hospitals. The facility title and size of research laboratory is originated from site area and research building location. The building function include not only the research lab and business office reflecting on the development platform, and but assembly and meeting room in the ground level. Laboratory floor plans have three types, rectangular, rectangular+linear and linear type, one is traditional and efficient, the others are people and friendly. And building core types are correlated with lab space unit modules, single and double side core are shown in rectangular type. All the laboratories are open lab, composed with laboratory bench and research note writing desk facing the lab service and enclosed lab-support area. And they have communication space looking as warm and cozy common area for the innovation, convergence and collaboration. As the high risk of contamination and high standard for safety and security, equipment and facilities are well managed with biological environment including BSC, fume hood, PCR classification, eye washing and emergency shower.