• Title/Summary/Keyword: Horticultural greenhouse

Search Result 389, Processing Time 0.022 seconds

Fallow Cover Crop Species and Nitrogen Rate of Fertigated Solution on Cucumber Yield and Soil Sustainability in Greenhouse Condition

  • Lee, Seong Eun;Park, Jin Myeon;Noh, Jae Seung;Lim, Tae Jun
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.47 no.1
    • /
    • pp.23-27
    • /
    • 2014
  • Nutrient accumulation in surface soil has become a serious problem for cucumber production in greenhouse. However, still in many cases, soil management practices are only focused on maintaining crop yield, regardless of sustainability related with soil chemical properties. This study was conducted to propose a sustainable soil management practice by investigating the impact of cover crop species and nitrogen rate of fertigated solution on cucumber yield and soil chemical properties in greenhouse condition. Rye and hairy vetch were tested as a fallow cover crop, and each amount of urea (1/2, 3/4, 1 times of N fertilizer recommendations), determined by soil testing result, was supplied in fertigation plots as an additional nitrogen source. The result showed that the yield of cucumber was higher in rye treatment than control and hairy vetch treatment. In addition, rye effectively reduced EC and accumulated nutrients from the soil. Meanwhile, N concentration of fertigated solution showed no significant effect on the growth and yield of cucumber. Consequently, these results suggest that it is desirable to choose rye as a fallow catch crop for sustainable cucumber production in greenhouse.

A Report on the Control Effects of Automatic Dry Fog Sprayer on Aphids in Greenhouse Crops (시설 온실에서 진딧물에 대한 무인 연무방제기의 방제 효과 보고)

  • Kang, Taek-Jun;Kim, Se-Jin;Kim, Dong-Hwan;Yang, Chang Yeol;Kim, Hyeong-Hwan;Cho, Myoung-Rae
    • Korean journal of applied entomology
    • /
    • v.53 no.4
    • /
    • pp.479-483
    • /
    • 2014
  • The area of greenhouse horticulture has increased dramatically since the early 1990s in Korea. However, area per farmer still very small and diverse pest species occurs in greenhouse abundantly because of its protected condition. To manage pests, farmers use many pesticides frequently. Incessant and improper use of chemicals provoked pesticide resistance in pest and poisoning of farmers. In this study, we investigated the efficiencies of automatic dry fog sprayer for controlling two aphid species, Aphis gossypii and Myzus persicae, in greenhouse horticulture. When doors and side windows were completely closed in automatic dry fog sprayer treatment greenhouse, aphids were controlled similar level with conventional spraying method (percent control: 61.0~94.1%). However, when half of the doors and side windows of the greenhouse were opened, aphids were controlled poorly (percent control: 36.0~54.4%).

A field survey on roof ventilation system of single-span plastic greenhouse in cucurbitaceae vegetable cultivation (박과작물 재배 단동 비닐하우스의 천장 환기시스템 설치 실태조사)

  • Yeo, Kyung-Hwan;Yu, In-Ho;Rhee, Han-Cheol;Cheong, Jae-Woan;Choi, Gyeong Lee
    • Korean Journal of Agricultural Science
    • /
    • v.40 no.4
    • /
    • pp.317-323
    • /
    • 2013
  • This research was conducted to obtain the basic information for establishment of standard guidelines in the design and installation of roof ventilation system in single-span plastic greenhouse. To achieve this, the greenhouse structure & characteristics, cultivation status, and ventilation system were investigated for single-span greenhouse with roof ventilation system cultivating the Cucurbitaceae vegetables, watermelon, cucumber, and oriental melon. Most of single-span watermelon greenhouse in Haman and Buyeo area were a hoop-style and the ventilation system in those greenhouses mostly consisted of two different types of 'roof vent (circular or chimney type) + side vent (hole) + fan' and 'roof vent (circular type) + side vent (hole or roll-up type)'. The diameter of circular and chimney-type vent was mostly 60cm and the average number of vents was 10.5 per a bay with vent spacing of average 6.75m. The ratio of roof vent area to floor area and side vent area in the single-span watermelon greenhouse with ventilation fan were 0.46% and 7.6%, respectively. The single-span cucumber greenhouse in Haman and Changnyeong area were a gable roof type, such as even span, half span, three quarter and the 70.6% of total investigated single-span greenhouses was equipped with a roof ventilation fan while 58.8% had a circulation fan inside the greenhouse. The ratios of roof vent area to floor area in the single-span cucumber greenhouse ranged from 0.61 to 0.96% and in the case of the square roof vent, were higher than that of the circular type vent. On average, the roof ventilation fan in single-span cucumber greenhouse was equipped with the power input of 210W and maximum air volume of $85.0m^3/min$, and the number of fans was 9.75 per a bay. The number of roof vent of single-span oriental melon greenhouse with only roll-up type side vent ranged from 8 to 21 (average 14.8), which was higher than that of other Cucurbitaceae vegetables while the vent number of the greenhouse with a roof ventilation fan was average 7 per a bay.

Development of Semi-basement Type Greenhouse Model for Energy Saving

  • Kim, Seoung Hee;Joen, Jong Gil;Kwon, Jin Kyeong;Kim, Hyung Kweon
    • Journal of Biosystems Engineering
    • /
    • v.41 no.4
    • /
    • pp.328-336
    • /
    • 2016
  • Purpose: The heat culture areas of greenhouses have been continuously increasing. In the face of international oil price fluctuations, development of energy saving technologies is becoming essential. To save energy, auxiliary heat source and thermal insulation technologies are being developed, but they lack cost-efficiency. The present study was conducted to save energy by developing a conceptually new semi-basement type greenhouse. Methods: A semi-basement type greenhouse, was designed and constructed in the form of a three quarter greenhouse as a basic structure, which is an advantageous structure to inflow sunlight. To evaluate the performance of the developed greenhouse, a similar structured general greenhouse was installed as a control plot, and heating tests were conducted under the same crop growth conditions. Results: Although shadows appeared during the winter in the semi-basement type greenhouse due to the underground drop, the results of crop growth tests indicated that there were no differences in crop growth and development between the semi-basement type greenhouse and the control greenhouse, indicating that the shadows did not affect the crop up to the height of the crop growing point. The amount of fuel used for heating from January to March was almost the same between the two greenhouses for tests. The heating load coefficients of the experimental greenhouses were calculated as $3.1kcal/m^2{\cdot}^{\circ}C{\cdot}h$ for the semi-basement type greenhouse and $2.9kcal/m^2{\cdot}^{\circ}C{\cdot}h$ for the control greenhouse. Since the value is lower than the double layer PE (polyethylene) film greenhouse value of $3.5kcal/m^2{\cdot}^{\circ}C{\cdot}h$ from a previous study, Tthe semi-basement type greenhouse seemed to have energy saving effects. Conclusions: The semi-basement type greenhouse could be operated with the same fuel consumption as general greenhouses, even though its underground portion resulted in a larger volume, indicating positive effects on energy saving and space utilization. It was identified that the heat losses could be reduced by installing a thermal curtain of multi-layered materials for heat insulation inside the greenhouse for the cultivation of horticultural products by installing thermal curtain of multi-layered materials for heat insulation inside the greenhouse, it was identified that the heat losses could be reduced.

Effect of Greenhouse Cooling and Transplant Quality Using Geothermal Heat Pump System (지열-열펌프 시스템의 온실냉방 및 육묘 효과)

  • Lee, Jae-Han;Lee, Yong-Beom;Kwon, Joon-Kook;Kang, Nam-Jun;Kim, Hak-Joo;Choi, Young-Hah;Park, Jin-Myeon;Rhee, Han-Cheol
    • Journal of Bio-Environment Control
    • /
    • v.15 no.3
    • /
    • pp.211-216
    • /
    • 2006
  • This study was carried out to investigate the effect of greenhouse cooling by a geothermal heat pump system on greenhouse temperature and growth of vegetable transplants in summer season. Greenhouse air temperature in day time was $3-4^{\circ}C$ lower in fog plus shading system than in shading, while in night time that was $5-7^{\circ}C$ lower in geothermal heat pump (GHP) plus shading system compared to shading or fogplus shading. system. Plant height of cucumber, tomato and hot pepper transplants was shortened in GHP plus shading compared to shading or fog plus shading system. And Leaf area and dry weight were slightly decreased in GHP plus shading compared to the other systems. Therefore, healthy transplant index on cucumber, tomato and hot pepper was higher in GHP plusshading than in shading or fogplusshading system.

Greenhouse Evaluation of Melon Rootstock Resistance to Monosporascus Root Rot and Vine Decline as Well as of Yield and Fruit Quality in Grafted 'Inodorus' Melons

  • Jang, Yoonah;Huh, Yun-Chan;Park, Dong-Kum;Mun, Boheum;Lee, Sanggyu;Um, Yeongcheol
    • Horticultural Science & Technology
    • /
    • v.32 no.5
    • /
    • pp.614-622
    • /
    • 2014
  • Melons (Cucumis melo L.) are generally grafted onto Cucurbita rootstocks to manage soilborne pathogens such as Monosporascus root rot and v ine decline (MRR/VD) and Fusarium wilt. However, g rafting onto Cucurbita rootstocks reportedly results in the reduction of fruit quality. In this study, the resistance to MRR/VD, yield, and fruit quality of melons grafted onto melon rootstocks were evaluated under greenhouse conditions. Eight melon rootstocks (R1 to R8) were used and the inodorus melon 'Homerunstar' was used as scion. Melon rootstocks R1 to R6 were selected based on resistance to MRR/VD under greenhouse conditions. Non-grafted 'Homerunstar' and plants grafted onto squash interspecific hybrid 'Shintozwa' rootstock (Cucurbita maxima D. ${\times}$ C. moschata D.) served as controls. Grafted melons were cultivated in the greenhouse infested with Monosporascus cannonballus during two growing seasons (summer and autumn). The responses to MRR/VD, yield, and fruit quality differed depending on the rootstocks and growing season. The melons grafted onto 'Shintozwa' exhibited less severe disease symptoms and higher survival rates than non-grafted melons in both seasons. While the melon rootstocks in the summer cultivation did not increase the survival rate compared to non-grafted melons, the melon rootstocks R1 and R2 in the autumn cultivation led to higher survival rates. The melon rootstocks resistant to MRR/VD increased the percentage of marketable fruits and marketable yields. Grafting onto the melon rootstocks caused little or no reduction of fruit quality such as low calcium content, fruit softening, and vitrescence, especially in lower-temperature autumn season. Accordingly, these results suggest that grafting onto the melon rootstocks may increase the tolerance to MRR/VD and the marketable yield without a reduction of fruit quality.

Heat Loss Audit and Assessment of the Greenhouses Using Infrared Thermal Image Analysis (적외선 열화상 분석을 통한 온실의 열손실 진단 및 평가)

  • Moon, Jong-Pil;Yun, Nam-Kyu;Lee, Sung-Hyoun;Kim, Hak-Joo;Lee, Su-Jang;Kim, Young-Hwa
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.52 no.2
    • /
    • pp.67-73
    • /
    • 2010
  • Unlike Urban building, horticultural facilities has a lot of heat loss through plastic or glass covering material which could be much influential to growing plant and consuming energy for heating greenhouse. In many cases, heat loss from a break of cover, a gap of joint sealing, the entrance to greenhouse and windows for ventilation are the main factors considered in calculating the heating load for horticultural facilities. however the normal observation through human eye and digital camera could not recognize where the heat loss occurred. but the infrared thermal image camera with detecting thermal difference could be very effective for noticing heat loss by analyzing infrared thermal image. In this study, greenhouse structure, covering material, internal and external provisions for Horticultural facilities were surveyed in different sites and Infrared thermal camera shooting and image analysis were performed for auditing heat loss from cultivation facilities The results from this study were that unexpected heat loss had been noticed in 7 representative cases of greenhouse such as side wall covered with single or double plastic, and the joint of horizontal thermal curtain, roof without horizontal thermal curtain, entrance to greenhouse, windows for ventilation. the most important factors for keeping heat energy were whether the horizontal thermal curtain with multifold thermal material was installed or not. The internal or external covering using multifold thermal curtain proved to be the most effective ways to keep heat energy from losing through heat transmission, heat radiation. from inside to outside the horticultural facilities.

Control Effect of Sudan Grass on Root-Knot Nematode, Meloidogyne incognita, in Cucumber and Lettuce Greenhouses (오이와 상추 재배지에서 수단그라스를 이용한 Meloidogyne incognita의 방제 효과)

  • Kim, Hyeong-Hwan;Kim, Dong-Hwan;Yang, Chang-Yeol;Kang, Taek-Jun;Han, Kyung-Sook;Park, Hae-Woong;Jung, Young-Hak;Jeon, Sung-Wook;Song, Jin-Sun;Choo, Ho Yul
    • Research in Plant Disease
    • /
    • v.20 no.4
    • /
    • pp.264-269
    • /
    • 2014
  • The effect of biological control of the root-knot nematode, Meloidogyne incognita, on cucumber and lettuce was evaluated with green manure crop species in greenhouse. Nematicidal effect of sudan grass cultivation in cucumber greenhouse was comparable to that of chemical treatment with fosthiazate GR, showing the high activity of 88.6%. Sudan grass cultivation in lettuce greenhouse significantly reduced the number of M. incognita in soil, showing 93.5% of nematiidal activity. In addition, since growth of sudan grass was superior to other green manure crop species, it is considered that cultivation of sudan grass is proper to control M. incognita in greenhouse.

Effect of Surfactant Concentrations on Anti-waterdrop, Environment and Lettuce(Lactuca sativa L.) Growth in Polyethylene Film Greenhouse (계면활성제 처리 농도가 무가온 플라스틱온실의 방적성, 환경 및 상추 생육에 미치는 영향)

  • Chun, Hee;Lee, Hye-Eun;Yemm, Sung-Hyun;Kim, Hak-Ju;Lee, Si-Young;Nam, Yooun-Il;Kim, Kyung-Je
    • Journal of Bio-Environment Control
    • /
    • v.12 no.4
    • /
    • pp.195-199
    • /
    • 2003
  • In polyethylene film house treated with surfactants(SF316+FB0800), waterdrops attached on film surface were absorbed to filter paper of 9 cm in diameter and measured 1.21 mL in control, 0.15 mL in 1% and 0.07 mL in 2% on December 10 at 10:00, 2002. However, there was no clear difference between surfactant concentrations 1% and 2%, And the most waterdrop was measured at 10:00 in daytime. As the air temperature was higher in greenhouse, waterdrop was sweled. So, the least waterdrop was measured at 14:00. In greenhouse covered with surfactants concentrated 1% and 2%, transmittances of solar radiation were 9.3% and 12.9% higher than control, respectively. In air temperature and relative humidity, there were no significant difference in all greenhouse. in forenoon, the air temperature and relative surfactant treated film greenhouse tended 1~2$^{\circ}C$ warmer than that of control. However, sil temperatures of surfactant treated film greenhouse tended 3~4$^{\circ}C$ warmer than that of control. During winter, the lettuce growth in surfactant treated film greenhouse was faster than that of control. However, there was no difference between surfactant concentrations of 1% and 2%.

Economic Analysis of Cooling-Heating System Using Ground Source Heat in Horticultural Greenhouse (시설원예의 지열냉·난방시스템 경제성 분석)

  • Ryoo, Yeon-Su;Joo, Hye-Jin;Kim, Jin-Wook;Park, Mi-Lan
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.6
    • /
    • pp.60-67
    • /
    • 2012
  • Government Geothermal Cooling-Heating Projects has made efforts to reduce GHG(Greenhouse Gas) emissions and to manage cost of greenhouse farm households. This study evaluated the economic benefits of heating load rate of change by comparing Geothermal Cooling-Heating System with the existing system(greenhouse diesel heating) in the Government Geothermal Cooling-Heating Projects. Economic analysis results shows that, 1) When installing the Cooling-Heating system according to the ratio of 70% heating load in policy standards, the geothermal cooling-heating system has economic efficiency with greenhouse type or scale independent because the investment cost is recovered within 7 years. And It was more economic efficiency the ratio of 50% heating load than70% heating load. 2) When installing the Cooling-Heating system according to the glass greenhouse of the ratio of 90% heating load, pay period of investment cost is recovered within 5 years. Therefore it is necessary to apply flexible heating sharing according to greenhouse type or scale.