• 제목/요약/키워드: Horizontal shear

검색결과 659건 처리시간 0.025초

전단벽식 건축구조물 수직진동의 수평방향 전달특성에 관한 실험연구 (An Experimental Study on the Vertical Vibration Transfer in Horizontal Way according to Shear Wall Building Structures due to Exciting Vibration Forces)

  • 전호민
    • 한국소음진동공학회논문집
    • /
    • 제16권3호
    • /
    • pp.270-282
    • /
    • 2006
  • In general, the vertical vibration problems for strength of members and serviceability of building structures are not considered in structural design process, but the prediction of the vertical vibration is very important and essential to structural design process. This study aims to investigate the characteristics of vertical vibration in terms of the transfer of horizontal directions to near-rooms on the shear wall building structures. In order to examine the characteristics of vertical vibration, the modal test and the impact (heel-drop and hammer) excitation experiments were conducted several times on two building structure. The results from the experiments are analyzed and compared with the results. The results of this study suggest that the characteristics of vertical vibration transfer in horizontal way are effected from the fundamental frequency of the slabs, and are effected the shear wall on the Path of the vibration transfer.

효과적인 강자성체 평판구조물 검사를 위한 전 방향 전단파 자기변형 패치 트랜스듀서 개발 (Development of an omni-directional shear-horizontal wave magnetostrictive patch transducer for the effective inspection of a ferromagnetic plate)

  • 승홍민;김윤영
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.548-549
    • /
    • 2014
  • Omni-directional shear-horizontal magnetostrictive patch transducers have a disadvantage that magnetic flux leakage into the plate when it is installed on a ferromagnetic plate. The leakage produces poor transduction efficiency and unwanted wave mode excitation which should be avoided in guided wave inspections of large plate-like structures. In order to resolve these problems, we newly developed a method to reduce the leakage into the plate. In the method, the patch and the magnet are vertically lifted off and their optimal positions are determined by numerical simulations. Also, the verification of the developed method is successfully verified by experiments.

  • PDF

패널파괴형 철골 커플링 보-벽체 접합부의 내진거동 (Seismic Behavior of Steel Coupling Beam-Wall Connection with Pane Shear Failure)

  • 박완신;한민기;김선우;황선경;양일승;윤현도
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.431-434
    • /
    • 2005
  • In the past decade, various experimental programmes were undertaken to address the lack of information on the interaction between steel coupling beams and reinforced concrete shear wall in a hybrid coupled shear wall system. In this paper, the seismic performance of steel coupling beam-wall connections in a hybrid coupled shear wall system is examined through results of an experimental research programme where three 2/3-scale specimens were tested under cyclic loading. The test variables included the reinforcement details that confer a ductile behaviour on the steel coupling beam-wall connection, i.e., the face bearing plates and the horizontal ties in the panel region of steel coupling beam-wall connections. Panel shear strength reflects enhancement achieved through mobilization of the reinforced concrete panel using face bearing plates and/or horizontal ties in the panel region of steel coupling beam-wall connections.

  • PDF

Tests of reinforced concrete deep beams

  • Lu, Wen-Yao;Hsiao, Hsin-Tai;Chen, Chun-Liang;Huang, Shu-Min;Lin, Ming-Che
    • Computers and Concrete
    • /
    • 제15권3호
    • /
    • pp.357-372
    • /
    • 2015
  • This study reports the test results of twelve reinforced concrete deep beams. The deep beams were tested with loads applied through and supported by columns. The main variables studied were the shear span-to-depth ratios, and the horizontal and vertical stirrups. The shear strengths can be effectively enhanced for deep beams reinforced with both horizontal and vertical stirrups. The test results indicate the shear strengths of deep beams increase with the decrease of the shear span-to-depth ratios. The normalized shear strengths of the deep beams did not increase proportionally with an increase in effective depth. An analytical method for predicting the shear strengths of deep beams is proposed in this study. The shear strengths predicted by the proposed method and the strut-and-tie model of the ACI Code are compared with available test results. The comparison shows the proposed method can predict the shear strengths of reinforced concrete deep beams more accurately than the strut-and-tie model of the ACI Code.

전단벽-골조 시스템의 내진설계를 위한 근사해석법 (Approximate Analysis of Shear Wall-Frame Structure For Seismic Design)

  • 유석형
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제23권2호
    • /
    • pp.99-106
    • /
    • 2019
  • 횡력을 받는 전단벽-골조 시스템은 휨거동을 하는 전단벽과 전단거동을 하는 골조가 슬래브의 강체평면운동(Diaphragm Action)을 통하여 상호작용하여 수평력에 효율적으로 저항하는 시스템이다. 횡력을 받는 골조의 거동은 보와 기둥의 휨 변형에 의한 골조의 수평 전단변형과 기둥의 축 변형에 의한 골조의 휨 변형으로 구분 할 수 있다. 일반적으로 전단벽-골조 시스템의 근사해석 시 골조의 휨변형은 무시하여 왔으나, 건물의 높이가 증가 할수록 골조의 휨 거동은 큰 영향을 미칠 것으로 사료된다. 따라서 본 연구에서는 횡력을 받는 전단벽-골조 시스템의 근사해석 시 기둥의 축 변형을 고려하기위하여 병렬전단벽 시스템(Coupled Shear Wall System)의 해석 시 사용하는 연속매체모델(Continuous Medium Model)을 이용하여 횡 변위 및 부재력을 산정할 수 있는 근사식을 수정 제시 하였다. 새롭게 제시된 근사식을 검토하기 위하여 기존 식과 컴퓨터에 의한 Matrix해석 결과와 비교하였으며, 비교결과 건물 높이가 높을수록 본 연구에서 제시한 근사해석 식이 기존 식보다 Matrix 해석 결과에 가깝게 나타났다.

준설매립토에 대한 실내 수평배수재 실험에서 진공압의 효과 (Effects of Vacuum Pressure in The Laboratory Horizontal Drain Test for Dredged Clay)

  • 양원준;장연수;박정용
    • 한국지반신소재학회논문집
    • /
    • 제3권1호
    • /
    • pp.17-25
    • /
    • 2004
  • 준설토의 표층개량을 위해 타설하는 수평배수재의 개량효과를 증가하기 위하여 수평배수재의 단부에 진공압을 가하여 지중의 간극수를 강제로 배출하는 진공압식 수평배수공법이 사용되고 있다. 본 연구에서는 진공압의 크기에 따른 준설매립지반의 압밀 및 강도 증가효과를 규명하기 위하여 토조시험을 실시한 후 순수 자중압밀의 경우와 비교하였다. 그 결과 자중압밀의 경우 표층부로부터 깊이가 깊어질수록 함수비가 작아지는 경향을 보였으나, 진공압이 재하된 경우는 진공압의 크기가 커질수록 배수재 주위에 낮은 함수비가 배수재에서 멀어질수록 높은 함수비 분포를 나타내었다. 진공압이 재하된 경우 준설토의 전단강도 또한 배수재를 중심으로 큰 개량효과를 얻을 수 있었으며, 토조시험기의 폭이 0.5m로 실제 현장에서 적용되는 배수재 간격이 0.7m~1.2m인 것을 고려했을 때 토조시험기에서는 진공압 30kPa~40kPa 범위에서 최적의 압밀효과를 얻을 수 있었다.

  • PDF

Assessment of the performance of composite steel shear walls with T-shaped stiffeners

  • Zarrintala, Hadi;Maleki, Ahmad;Yaghin, Mohammad Ali Lotfollahi
    • Earthquakes and Structures
    • /
    • 제23권3호
    • /
    • pp.297-313
    • /
    • 2022
  • Composite steel plate shear wall (CSPSW) is a relatively novel structural system proposed to improve the performance of steel plate shear walls by adding one or two layers of concrete walls to the infill plate. In addition, the buckling of the infill steel plate has a significant negative effect on the shear strength and energy dissipation capacity of the overall systems. Accordingly, in this study, using the finite element (FE) method, the performance and behavior of composite steel shear walls using T-shaped stiffeners to prevent buckling of the infill steel plate and increase the capacity of CSPSW systems have been investigated. In this paper, after modeling composite steel plate shear walls with and without steel plates with finite element methods and calibration the models with experimental results, effects of parameters such as several stiffeners, vertical, horizontal, diagonal, and a combination of T-shaped stiffeners located in the composite wall have been investigated on the ultimate capacity, web-plate buckling, von-Mises stress, and failure modes. The results showed that the arrangement of stiffeners has no significant effect on the capacity and performance of the CSPSW so that the use of vertical or horizontal stiffeners did not have a significant effect on the capacity and performance of the CSPSW. On the other hand, the use of diagonal hardeners has potentially affected the performance of CSPSWs, increasing the capacity of steel shear walls by up to 25%.

고강도 철근콘크리트 깊은 보의 전단거동 및 ACI 전단설계 기준과의 비교 (Shear Behavior of High-Strength Concrete Deep Beams and Comparisons with ACI Shear Design Provisions)

  • 정헌수;양근혁;함영삼
    • 콘크리트학회논문집
    • /
    • 제14권6호
    • /
    • pp.874-882
    • /
    • 2002
  • 현재, 깊은 보의 전단설계는 보통강도 콘크리트를 사용한 일반 보의 사인장 균열내력에 대한 실험식인 ACI 기준에 기본을 두고 시행되고 있지만, 고강도 철근콘크리트 깊은 보의 전단거동에 대한 자료는 매우 제한적이다. 따라서, 본 실험연구의 목적은 고강도 철근콘크리트 깊은 보의 전단거동을 이해하고 ACI 설계 기준의 안전율을 파악하기 위한 것이다. 상부 2점 대칭하중을 받는 22개의 고강도 콘크리트 깊은 보의 전단내력에 대한 실험결과를 나타내었다. 콘크리트 압축강도는 800kgf/$\textrm{cm}^2$이며, 주요 변수로는 전단경간비, 전단철근의 양 및 배근 형태 등이다. 실험결과로부터 전단철근의 전단저항에 대한 효율성은 ACI 기준에서 제시하는 순 경간깊이비(1n/d) 보다는 전단경간비가 크게 관계되었으며 전단경간비가 0.75 이상에서 수직 전단철근이 수평 전단철근보다 전단저항에 더 효율적이었다. 고강도 철근콘크리트 깊은 보의 전단내력을 예측하기 위하여 실험결과들과 전단마찰이론에 근거해서 ACI 기준식을 수정, 제시하였다.

Lateral deformation capacity and stability of layer-bonded scrap tire rubber pad isolators under combined compressive and shear loading

  • Mishra, Huma Kanta;Igarashi, Akira
    • Structural Engineering and Mechanics
    • /
    • 제48권4호
    • /
    • pp.479-500
    • /
    • 2013
  • This paper presents the experimental as well as analytical study conducted on layer-bonded scrap tire rubber pad (STRP) isolators to develop low-cost seismic isolators applicable to structures in developing countries. The STRP specimen samples were produced by stacking the STRP layers one on top of another with the application of adhesive. In unbonded application, the STRP bearings were placed between the substructure and superstructure without fastening between the contact surfaces which allows roll-off of the contact supports. The vertical compression and horizontal shear tests were conducted with varying axial loads. These results were used to compute the different mechanical properties of the STRP isolators including vertical stiffness, horizontal effective stiffness, average horizontal stiffness and effective damping ratios. The load-displacement relationships of STRP isolators obtained by experimental and finite element analysis results were found to be in close agreement. The tested STRP samples show energy dissipation capacity considerably greater than the natural rubber bearings. The layer-bonded STRP isolators serve positive incremental force resisting capacity up to the shear strain level of 150%.

Analysis of reinforced concrete corbel beams using Strut and Tie models

  • Parol, Jafarali;Al-Qazweeni, Jamal;Salam, Safaa Abdul
    • Computers and Concrete
    • /
    • 제21권1호
    • /
    • pp.95-102
    • /
    • 2018
  • Reinforced concrete corbel beams (span to depth ratio of a corbel is less than one) are designed with primary reinforcement bars to account for bending moment and with the secondary reinforcement placed parallel to the primary reinforcement (shear stirrups) to resist shear force. It is interesting to note that most of the available analytical procedures employ empirical formulas for the analysis of reinforced concrete corbels. In the present work, a generalized and a simple strut and tie models were employed for the analysis of reinforced corbel beams. The models were benchmarked against experimental results available in the literature. It was shown here that increase of shear stirrups increases the load carrying capacity of reinforced concrete corbel beams. The effect of horizontal load on the load carrying capacity of the corbel beams has also been examined in the present paper. It is observed from the strut and tie models that the resistance of the corbel beam subjected to combined horizontal and vertical load did not change with increase in shear stirrups if the failure of the corbel is limited by concrete crushing. In other words, the load carrying capacity was independent of the horizontal load when failure of the beam occurred due to concrete crushing.