• 제목/요약/키워드: Horizontal geothermal heat pump

검색결과 19건 처리시간 0.019초

수평형 지중열교환기를 이용한 건물일체형 지열시스템의 도입타당성 분석 (The feasibility study for the building integrated geothermal system using the horizontal heat exchanger)

  • 채호병;남유진;윤성훈
    • 한국태양에너지학회 논문집
    • /
    • 제35권1호
    • /
    • pp.81-87
    • /
    • 2015
  • Recently, in order to prevent increasing energy usages in the international community, many countries have attempted to develop the innovative renewable energy systems. Among the renewable energy systems, Ground source heat pump(GSHP) system which supply the heating, cooling and hot water in the building has been attracted by its stability of heat production and high efficiency. However, the initial drilling costs become very expensive and the construction period takes longer the other systems, because GSHP system needs more than 100 m depth drilling. In this study, in order to reduce initial costs of the GSHP, the building integrated geothermal system using the horizontal heat exchanger was developed. The heating and cooling load in the standard housing model was calculated by a simulation and the system design capacity in the high-rise apartment was decided by the total load. Based on the system design capacity, the high-rise apartments were applied to a BIGS and vertical GSHP system and there are analyzed about initial costs. In the result, the initial cost of BIGS could reduce 24% of the initial cost of the vertical GSHP system.

건물구조체를 이용한 수평형 지열시스템의 시공법에 관한 연구 (Study on construction method of horizontal ground heat pump system using the building structure)

  • 채호병;남유진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 추계 학술논문 발표대회
    • /
    • pp.139-140
    • /
    • 2013
  • Ground source heat pump systems can achieve the energy saving of building and reduce CO2 emission by utilizing stable ground temperature. However, they have many barriers such as high cost of installation, incompletion of design tool, lack of recognition as heating and cooling systems. In order to solve the problems, the building integrated geothermal system (BIGS) developed by several researches which use building foundation as a heat exchanger. In order to establish the optimum design tool of BIGS with the horizontal heat exchanger, the prediction method of ground heat exchange rate developed with numerical simulation model. In this study, the economic analysis for BIGS was conducted based on simulation results and the optimal design method was suggested. As a result, it was found that the case of 32 A, piping space 0.3 m, piping deep 0.5 m and flow rate 9.52 L/min was the best case as 50.1 W/m2 of heat exchange rate. In this case the initial cost was reduced to 115 million won.

  • PDF

시설원예를 위한 수평형 지열 히트펌프의 냉방성능 해석 (Cooling Performance of Horizontal Type Geothermal Heat Pump System for Protected Horticulture)

  • 유영선;강연구;강금춘;김영중;백이
    • 생물환경조절학회지
    • /
    • 제17권2호
    • /
    • pp.90-95
    • /
    • 2008
  • 수직형에 비해 비교적 가격이 저렴하고 냉난방을 동시에 할 수 있는 농업시설에 적합한 10RT 규모의 수평형 지열히트펌프 시스템을 $240m^2$ 면적의 온실에 설치하고, 이 시스템의 냉방성능을 분석하였다. 응축기 출구온도가 $40^{\circ}C$에서 $58^{\circ}C$로 상승함에 따라 소비전력은 11.5kW에서 15kw로 상승하였으며, 고압이 1,617kpa에서 2,450kPa로 변화하였다. 냉방성능계수는 지중온도 $25.5^{\circ}C$에서 2.7 수준이었으며 지온이 상승함에 따라 하강하여 $33.5^{\circ}C$에서 2.0 수준이었다. 또한 온실 내부로부터 흡수하는 열량(냉방열량)은 같은 지중온도 수준에서 각각 28.8kW, 26.5kW이었다. 가동 8시간 후 지열교환기가 설치된 60cm깊이의 지온은 $14.3^{\circ}C$가 상승하였으며 150cm는 $15.3^{\circ}C$가 상승하였다. 반면 지열교환기가 매설되지 않은 60cm 깊이는 2.4, 150cm 깊이는 $4.3^{\circ}C$의 지온상승을 보였다. 열매 체유가 지열교환기를 통과한 후 평균 $7.5^{\circ}C$의 온포가 하강하였으며, 토양온도가 평균 $27.5^{\circ}C$ 수준에서 토양으로 방출하는 열량은 평균 46kw로 지중열교환기의 단위 길이 당 약 36.8W의 열량을 방출하는 것으로 분석되었다. 팬코일 유닛이 온실로부터 흡수하는 냉방 열량은 평균 28.2kW이었으며, 열매체유의 온도는 $4.2^{\circ}C$ 상승하였다. 축열조내 열전달매체유의 온도가 $26.0^{\circ}C$에서 $2.0^{\circ}C$까지 하강하는데 3시간이 소요되었으며, 평균 축열율은 29.7kW, 총 축열량은 321MJ이었다. 또한 $2.0^{\circ}C$까지 냉열을 축열한 후 $25.4^{\circ}C$까지 방열되는 시간은 외기온이 평균 $28.5^{\circ}C$일 때 4시간이었고, 총 313.0MJ의 에너지가 방열되었으며, 이때 평균 방열율은 21.7kW인 것으로 분석되었다.

출구 온도를 고려한 수평형 지중열교환기의 매설 지침에 관한 연구 (A Study on Burial Guideline of Horizontal Geothermal Heat Exchanger based on Exit Temperature)

  • 조성우;임병찬
    • 설비공학논문집
    • /
    • 제26권12호
    • /
    • pp.553-558
    • /
    • 2014
  • Geothermal energy can be used with a geothermal heat pump or an earth-to-air heat exchange system (EAHES), which is referred to as a "cooling tube" in Korea. In this study, we suggest EAHES burial guidelines in terms of the parameters of buried pipe length and air velocity regarding the exit air temperature of EAHES. The exit air temperature for EAHES in three regions (Changwon, Busan and Seoul) was calculated with variation in buried pipe length and air velocity at ${\Phi}100mm$ and ${\Phi}200mm$. In conclusion, variation in the buried pipe length is more effective than that of air velocity to achieve the required exit air temperature.

EnergyPlus를 이용한 수평형의 지열 히트펌프와 어스튜브를 조합한 시스템의 성능 검토 (Performance Analysis on Combined Horizontal Ground Source Heat Pump with Earth tube using EnergyPlus)

  • 조성우
    • 한국지열·수열에너지학회논문집
    • /
    • 제13권2호
    • /
    • pp.22-29
    • /
    • 2017
  • This study is performed to performance of the combined system the GSHP (Ground Source Heat Pump) system with the Earth tube system using EnergyPlus program. The Earth tube system using fan is characteristics as supply lower (higher) air temperature than outdoor air temperature in cooling and heating seasons, the GSHP system is characteristics as small indoor air temperature variation range. As the results of Earth tube + GSHP system simulation, GSHP power can be reduced than the GSHP single operation as 17.3% in cooling seasons and 32.5% in heating seasons, the GSHP design capacity can be replaced more small size.

강변여과수를 이용한 온실난방기술 개발 (Greenhouse Heating Technology Development by using Riverbank Filtration Water)

  • 문종필;이성현;권진경;강연구;유영선;이수장
    • 한국농공학회논문집
    • /
    • 제53권6호
    • /
    • pp.145-152
    • /
    • 2011
  • In order to heat greenhouse nearby river channel, riverbank filtration water source heat pump was developed for getting plenty of heat flux from geothermal energy. Recharging well, thermal storage tank with separating insulation plate and filtering tank for eliminating iron, manganese were mainly developed for making the coefficient of performance (COP) of heat pump higher. Heating system using riverbank filtration water source heat pump was installed at a paprika greenhouse in the Jinju region where a single fold of vinyl cover and 2 layers of horizontal thermal curtain were installed as a part of temperature keeping and heat insulation with a greenhouse area of 3,185 $m^2$. 320,000 kcal/h was supplied for performing a site application tests. A greenhouse heating test was performed from Feb. 1, 2011 to Apr. 30, 2011. As the result of that, COPh of the heat pump was measured in the range of 4.0~4.5, while COPS of the system was represented as 2.9~3.3. COP measured of the heat pump was very good and well responded to indoor heating temperature of the environment control system of a greenhouse.

몽골의 천부 지열에너지(냉난방 에너지)개발 가능성에 관한 연구 (A Study on Development Potential of Shallow Geothermal Energy as Space Heating and Cooling Sources in Mongolia)

  • 한정상;윤운상;윤건신;이태열;김형수
    • 한국지열·수열에너지학회논문집
    • /
    • 제8권2호
    • /
    • pp.36-47
    • /
    • 2012
  • Time-series variation of groundwater temperature in Mongolia shows that maximum temperature is occured from end of October to the first of February(winter time) and minimum temperature is observed from end of April to the first of May(summer time). Therefore ground temperature is s a good source for space heating in winter and cooling in summer. Groundwater temperatures monitored from 3 alluvial wells in Ulaabaatar at depth between 20 and 24 m are $(4.43{\pm}0.8)^{\circ}C$ with average of $4.21^{\circ}C$ but mean annual ground temperature(MAGT) at the depth of 100 m in Ulaanbaatar was about $3.5{\sim}6.0^{\circ}C$. Bore hole length required to extract 1 RT's heat energy from ground in heating time and to reject 1 RT's heat energy to ground in summer time are estimated about 130 m and 98 m respectively. But in case that thermally enhanced backfill and U tube pipe placement along the wall are used, the length can be reduced about 25%. Due to low MAGT of Ulaabaatar such as $6^{\circ}C$, the required length of GHX in summer cooling time is less than the one of winter heating time. Mongolia has enough available property, therefore the most cost effective option for supplying a heating energy in winter will be horizontal GHX which absorbs solar energy during summer time. It can supply 1 RT's ground heat energy by 570 m long horizontally installed GHX.

설비공학 분야의 최근 연구 동향 : 2016년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2016)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제29권6호
    • /
    • pp.327-340
    • /
    • 2017
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2016. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of flow, heat and mass transfer, the reduction of pollutant exhaust gas, cooling and heating, the renewable energy system and the flow around buildings. CFD schemes were used more for all research areas. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results of the long-term performance variation of the plate-type enthalpy exchange element made of paper, design optimization of an extruded-type cooling structure for reducing the weight of LED street lights, and hot plate welding of thermoplastic elastomer packing. In the area of pool boiling and condensing, the heat transfer characteristics of a finned-tube heat exchanger in a PCM (phase change material) thermal energy storage system, influence of flow boiling heat transfer on fouling phenomenon in nanofluids, and PCM at the simultaneous charging and discharging condition were studied. In the area of industrial heat exchangers, one-dimensional flow network model and porous-media model, and R245fa in a plate-shell heat exchanger were studied. (3) Various studies were published in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, subjects include mobile cold storage heat exchanger, compressor reliability, indirect refrigeration system with $CO_2$ as secondary fluid, heat pump for fuel-cell vehicle, heat recovery from hybrid drier and heat exchangers with two-port and flat tubes. In the alternative refrigeration/energy system category, subjects include membrane module for dehumidification refrigeration, desiccant-assisted low-temperature drying, regenerative evaporative cooler and ejector-assisted multi-stage evaporation. In the system control category, subjects include multi-refrigeration system control, emergency cooling of data center and variable-speed compressor control. (4) In building mechanical system research fields, fifteenth studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, renewable energies, etc. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which could be help for improving the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the analyses of indoor thermal environments controlled by portable cooler, the effects of outdoor wind pressure in airflow at high-rise buildings, window air tightness related to the filling piece shapes, stack effect in core type's office building and the development of a movable drawer-type light shelf with adjustable depth of the reflector. The subjects of building energy were worked on the energy consumption analysis in office building, the prediction of exit air temperature of horizontal geothermal heat exchanger, LS-SVM based modeling of hot water supply load for district heating system, the energy saving effect of ERV system using night purge control method and the effect of strengthened insulation level to the building heating and cooling load.