• 제목/요약/키워드: Horizontal furnace

검색결과 109건 처리시간 0.032초

기상응축 열교환을 이용한 고정밀 등온 가열로 개발 (Development of Heat-treatment Furnace with Maximum Uniform Zone using Gas-phase Condensing Heat Exchange)

  • 홍현선;공만식;강환국
    • 열처리공학회지
    • /
    • 제22권3호
    • /
    • pp.162-168
    • /
    • 2009
  • A horizontal tube furnace with a wide uniform-temperature zone was developed using isothermal characteristics of a heat pipe. The heat pipe heating system consists of a concentric annular shaped stainless-steel container, sodium as a working fluid and a screen mesh wick structure. The performance test of the heat pipe revealed that temperature changes along seven consecutive positions of the heat pipe outer wall were less than${\pm}0.1^{\circ}C$, thereby ensuring the high isothermal property. The isothermal property of the heat pipe-adapted tube fumace was investigated and compared to a conventional non-heat pipe type tube furnace. The temperature distribution measurement showed that the uniform temperature zone, in which temperature change is less than${\pm}$1$^{\circ}$C, of the heat pipe employed tube furnace system was about three times longer compared to the conventional tube furnace system.

수평형 CGL 소둔로의 연소 및 가열 성능 해석을 위한 오픈소스 OpenFOAM 기반 전산유체 해석 (Application of Open-source OpenFOAM for Simulating Combustion and Heating Performance in Horizontal CGL Furnace)

  • 김군홍;오경택;강덕홍
    • 대한기계학회논문집B
    • /
    • 제41권8호
    • /
    • pp.553-561
    • /
    • 2017
  • 본 연구에서는 산업용 가열 설비에 대한 연소 유동장과 복합 열전달 해석을 위하여 오픈소스 기반의 3차원 해석 시스템을 구축하고 실제 운전 중인 재가열로에 대한 해석을 통해 유용성을 확인하였다. 효율적인 가열로 전용 해석 체계를 위하여 오픈소스 OpenFOAM 라이브러리를 적용함으로써 다양한 해석 기능들을 추가로 개발할 수 있는 확장성과 상용 프로그램 도입에 비하여 경제성 측면에서도 장점들을 가지고 있다. 개발된 프로그램을 활용하여 실제 연속 아연 도금 강판 생산 공정 내의 수평형 소둔로에 대한 해석을 수행하였다. 해석 결과로부터 대상 가열 설비의 가열 성능은 고온 연소 기체에 의한 대류 보다는 복사 열전달 효과가 지배적이며, 이송되는 강판 표면으로 유입되는 복사 열전달량은 총 열전달량의 76% 수준으로 분석되었다. 현 가열로 전용 해석 시스템은 핵심적인 가열 설비 해석 기능을 포함하고 있지만, 다양한 연소 조건에 적용 가능한 난류 연소 모델과 가열로 벽면 열경계에 대한 추가적인 연구가 필요함을 확인하였다.

튜브형 가열로 반응기를 이용한 초미립 $SiO_2$ 입자의 제조 및 증착에 대한 수치모사 (The Numerical Simulation of Ultrafine $SiO_2$ Particle Fabrication and Deposition by Using the Tube Furnace Reactor)

  • 김교선;현봉수
    • 한국세라믹학회지
    • /
    • 제32권11호
    • /
    • pp.1246-1254
    • /
    • 1995
  • A numerical model for fabrication and deposition of ultrafine SiO2 particles were proposed in the simplified horizontal MCVD apparatus using tube furnace reactor. The model equations such as energy and mass balance equations and the 0th, 1st and 2nd moment balance equations of aerosols were considered in the reactor. The phenomena of SiCl4 chemical reaction, SiO2 particle formation and coagulation, diffusion and thermophoresis of SiO2 particles were included in the aerosol dynamic equation. The profiles of gas temperature, SiCl4 concentration and SiO2 particle volume were calculated for standard conditions. The concentrations, sizes and deposition efficiencies of SiO2 particles were calculated, changing the process conditions such as tube furnace setting temperature, total gas flow rate and inlet SiCl4 concentration.

  • PDF

HANJUNG 석탄 실험연소로의 초기운전 (The First Operation of Coal Combustion Test Facility in HANJUNG)

  • 장길홍;장인갑;정석용;천무환;김중석
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 1998년도 제17회 KOSCI SYMPOSIUM 논문집
    • /
    • pp.79-84
    • /
    • 1998
  • In this paper we show design and operation of 1MWth pulverized coal combustion test facility. The test facility is consists of coal feeding system, furnace and flue gas treatment system. The furnace is equipped with a top-fired burner in order to avoid influence of gravity on the coal particles. There are two part of vertical(VP) and horizontal pass(HP) at furnace. We can measure temperature and species of coal flames in vertical pass. Also, there is horizontally arranged section where investigation regarding corrosion and deposit formation will be carried out. The burner of combustor was externally air staging burner(EASB) type made by IFRF. The pulverized high bituminous(Blair athol) coal from Australia was used as fuel, and the particle size less than 80 ${\mu}m$ was 83.4%. Overall excess air ratio was 1.2.

  • PDF

The Effect of Particle Size on Ignition Characteristics of Pulverized High-Volatile Bituminous Coal

  • Kim, Hyung-Taek
    • 에너지공학
    • /
    • 제2권3호
    • /
    • pp.285-292
    • /
    • 1993
  • A cylindrical-shape, horizontal furnace was used to investigate the effect of particle size on the pulverized coal combustion behavior. Three differently-sized fractions (5, 30, and 44 microns in average diameter) of high-volatile bituminous coal, were burned in the test furnace. Ignition characteristics of pulverized coal flame were determined through the amount of methane in the carrier gas for the self-sustaining flame. Easiest ignition occurred with the immediately-sized coal particles. Ignition of coal jet flame appeared to occur through a gas-phase homogeneous process for particles larger than 30 microns. Below this limiting size, heterogeneous process probably dominated ignition of coal flame. Oxygen concentration of combustion air was varied up to 50%, to determine the oxygen-enrichment effect on the coal ignition behavior. Oxygen enrichment of primary air assisted ignition behavior of pulverized coal flame. However, enrichment of secondary air didn't produce any effect on the ignition behavior.

  • PDF

The Effect of Particle Size on Combustion Characteristics of Pulverized High-Volatile Bituminous Coal

  • Kim, Hyung-Taek;Jeon, Heung-Shin;Wongee Chun
    • 에너지공학
    • /
    • 제6권2호
    • /
    • pp.162-169
    • /
    • 1997
  • The particle size effect on the combustion characteristics of pulverized coal was investigated in the cylindrical-shape, horizontal furnace, fired in the range of 8.8∼10.6 kw. Three differently-sized fractions (5, 30, and 44 microns in average diameter) of high-volatile bituminous coal, were burned in the test furnace. Burnout behavior of pulverized coal flame were determined through the measurement of stable species concentrations (CO$_2$and H$_2$O). Concentrations of CO$_2$were compared with the theoretical values and the result showed good agreement. Thermal behavior of pulverized coal flame were determined as maximum flame temperatures occurred at fuel-rich conditions in every case. Flame lengths were also determined by decreasing with the particle size decrease. The flame length of the fine sized coal sample was comparable to that produced by distillate oil. The color of the coal flames ranged from orange to yellow, with the flame of the fine size fraction being brighter and yellower than the others.

  • PDF

터널 화재로 인한 콘크리트 세그먼트의 손상특성 규명 (Fire-induced damage on Shield TBM concrete segment)

  • 최순욱;장수호;이규필;배규진
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.423-430
    • /
    • 2005
  • Fire accidents in underground space may bring much loss of lives as well as properties and result in catastrophic disasters. This study aimed to manufacture the high-temperature furnace capable of simulating fire scenarios (RABT and RWS) and carry out the preliminary fire tests to evaluate fire-induced damage in underground structures. Specimens used in the fire tests were the concrete segments generally used in shield TBM tunnels. The simulated fire scenario was set to the RABT curve that is the most representative fire scenario in underground space. From the fire tests, the spalling was estimated to reach approximately 20cm from the surface exposed to fire. In addition, from the observation of core specimens obtained after fire tests, the deteriorated zone of unspalled specimens amounted to approximately 10cm from the surface of spalling.

  • PDF

Recycling of EAF Dust by Semi-continuous High Kinetic Process

  • Zoz, H.;Kaupp, G.;Ren, H.;Goepel, K.;Naimi-Jamal, M. R.
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part 1
    • /
    • pp.491-492
    • /
    • 2006
  • The horizontal high energy rotor ball mill ($Simoloyer^{(R)}$) is used to break and activate dry solids. It is used for dry-milling and in the vertical mount for wet-milling in leaching processes. Technical electric arc furnace (EAF) dust with high contents of zinc oxide, zinc ferrite and magnetite is efficiently separated by ambient temperature leaching. The process shows promise for industrial application

  • PDF

단일 온도대역 수평 Bridgman(1-T HB) 법에 의한 GaAs 단결정 성장시 As 원소의 초과 유입량 계산 (Calculation of the amount of excess As charge for the GaAs single crystal growting with the horizontal Bridgman method of single temperature zone(1-T HB))

  • 오명환;주승기
    • 한국결정학회지
    • /
    • 제7권1호
    • /
    • pp.64-72
    • /
    • 1996
  • 증기압 제어를 위한 저온부를 없애고, 고온부의 단일 온도영역만으로 GaAs 단결정을 성장 시키는 단일 온도대역 수평 Bridgman(1-T HB: single temperature zone horizontal Bridgman)방식에서는 증기압에 상응할만한 반응관 내부의 압력을 As 초과 유입량의 기화에 의하여 유지해야 하므로 그 양을 정밀하게 결정해 주어야 한다. 이것을 위하여, 우선적으로 Ga-As 계에서의 열화학적 특성을 규명하였고, 이에 근거하여 단일 온도대역 수평 Bridgman 법으로 결정성장할 때의 As 초과 유입량을 GaAs 장입량, 반응관 칫수, 온도구배 등에 의한 일반해로 유도하였다. 따라서 단일 온도대역 수평 Bridgman 법에 의한 GaAs 단결정 성장의 이론적 근거를 마련하였다.

  • PDF

An experimental and numerical analysis of concrete walls exposed to fire

  • Baghdadi, Mohamed;Dimia, Mohamed S.;Guenfoud, Mohamed;Bouchair, Abdelhamid
    • Structural Engineering and Mechanics
    • /
    • 제77권6호
    • /
    • pp.819-830
    • /
    • 2021
  • To evaluate the performance of concrete load bearing walls in a structure under horizontal loads after being exposed to real fire, two steps were followed. In the first step, an experimental study was performed on the thermo-mechanical properties of concrete after heating to temperatures of 200-1000℃ with the purpose of determining the residual mechanical properties after cooling. The temperature was increased in line with natural fire curve in an electric furnace. The peak temperature was maintained for a period of 1.5 hour and then allowed to cool gradually in air at room temperature. All specimens were made from calcareous aggregate to be used for determining the residual properties: compressive strength, static and dynamic elasticity modulus by means of UPV test, including the mass loss. The concrete residual compressive strength and elastic modulus values were compared with those calculated from Eurocode and other analytical models from other studies, and were found to be satisfactory. In the second step, experimental analysis results were then implemented into structural numerical analysis to predict the post-fire load-bearing capacity response of the walls under vertical and horizontal loads. The parameters considered in this analysis were the effective height, the thickness of the wall, various support conditions and the residual strength of concrete. The results indicate that fire damage does not significantly affect the lateral capacity and stiffness of reinforced walls for temperature fires up to 400℃.