• Title/Summary/Keyword: Horizontal distance

Search Result 834, Processing Time 0.035 seconds

Research About Students' Horizontal Heterophoria in Near Distance with Maddox Rod (Maddox Rod를 사용한 대학생의 근거리 수평사위에 대한 고찰)

  • Choi, Kyong-Seo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.3
    • /
    • pp.59-63
    • /
    • 2009
  • Purpose: To investigate the near horizontal heterophoria of the college students in their twenties on north Kyonggi Province. Methods: The all subjects had not experienced any ocular surgery and have no disease and their mean age is 22.9. As 122 subjects, they are 50 emmetropes and 72 ametropes. The ametropes are all myopia. After distance visual acuity correction with subjective and objective refraction test, evaluated their horizontal heterophoria with red maddox rod. Results: In maddox rod test, the subjects consist of orthophoria 4.9%, esophoria 9.8% and exophoria 85.3%. In the emmetropes orthophoria is 8%, esophoria is also 8% and exophoria is 84%. In the ametropes orthophoria is 2.8%, esophoria is 11.1% and exophoria is 86.1%. The mean size of horizontal heterophoria is esophoria 3.59PD (prism diopter), exophoria 7.04PD and in the emmetropes esophoria is 3.25PD, exophoria is 6.60PD. In the ametropes esophoria is 3.75PD and exophoria is 7.34PD. Conclusions: In the emmetropoes the orthophoria is more than in the ametropes and the esophoria and exophoria is more in the ametropes. But the differences between the heterophoria and emmetropia or ametropia were not significant (p>0.05). The mean size of heterophoria is higher in the ametropes than in the emmetropoes. The distribution range of heterophoria is wider in the male subjects than the female subjects.

  • PDF

MMS Data Accuracy Evaluation by Distance of Reference Point for Construction of Road Geospatial Information (도로공간정보 구축을 위한 기준점 거리 별 MMS 성과물의 정확도 평가)

  • Lee, Keun Wang;Park, Joon Kyu
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.39 no.6
    • /
    • pp.549-554
    • /
    • 2021
  • Precise 3D road geospatial information is the basic infrastructure for autonomous driving and is essential data for safe autonomous driving. MMS (Mobile Mapping System) is being used as equipment for road spatial information construction, and related research is being conducted. However, there are insufficient studies to analyze the effect of the baseline reference point distance, which is an important factor in the accuracy of the MMS outcome, on the accuracy of the outcome. Therefore, in this study, the accuracy of the data acquired using MMS by reference point distance was analyzed. Point cloud data was constructed using MMS for the road in the study site. For data processing, 4 data were constructed considering the distance from the reference point for MMS data, and the accuracy was analyzed by comparing the results of 12 checkpoints for accuracy evaluation. The accuracy of the MMS data showed a difference of -0.09 m to 0.11 m in the horizontal direction and 0.04 m to 0.19 m in the height direction. The error in the vertical direction was larger than that in the horizontal direction, and it was found that the accuracy decreased as the distance from the reference point increased. In addition, as the length of the road increases, the distance from the reference point may vary, so additional research is needed. If the accuracy evaluation of the method using multiple reference points is made in the future, it will be possible to present an effective method of using reference points for the construction of precise road spatial information.

Comparative analysis of craniofacial asymmetry in subjects with and without symptoms of temporomandibular joint disorders: a cross-sectional study

  • Anita Pradhan;Preeti Bhattacharya;Shivani Singh;Anil Kumar Chandna;Ankur Gupta;Ravi Bhandari
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.49 no.3
    • /
    • pp.125-134
    • /
    • 2023
  • Objectives: The aim of the study was to quantify and compare craniofacial asymmetry in subjects with and without symptoms of temporomandibular joint disorders (TMDs). Materials and Methods: A total of 126 adult subjects were categorized into two groups (63 with a TMDs and 63 without a TMDs), based on detection of symptoms using the Temporomandibular Joint Disorder-Diagnostic Index (TMD-DI) questionnaire. Posteroanterior cephalograms of each subject were traced manually and 17 linear and angular measurements were analyzed. Craniofacial asymmetry was quantified by calculating the asymmetry index (AI) of bilateral parameters for both groups. Results: Intra- and intergroup comparisons were analyzed using independent t-test and Mann-Whitney U test, respectively, with a P<0.05 considered statistically significant. An AI for each linear and angular bilateral parameter was calculated; higher asymmetry was found in TMD-positive patients compared with TMD-negative patients. An intergroup comparison of AIs found highly significant differences for the parameters of antegonial notch to horizontal plane distance, jugular point to horizontal plane distance, antegonial notch to menton distance, antegonial notch to vertical plane distance, condylion to vertical plane distance, and angle formed by vertical plane, O point and antegonial notch. Significant deviation of the menton distance from the facial midline was also evident. Conclusion: Greater facial asymmetry was seen in the TMD-positive group compared with the TMD-negative group. The mandibular region was characterized by asymmetries of greater magnitude compared with the maxilla. Patients with facial asymmetry often require management of temporomandibular joint (TMJ) pathology to achieve a stable, functional, and esthetic result. Ignoring the TMJ during treatment or failing to provide proper management of the TMJ and performing only orthognathic surgery may result in worsening of TMJ-associated symptoms (jaw dysfunction and pain) and re-occurrence of asymmetry and malocclusion. Assessments of facial asymmetry should take into account TMJ disorders to improve diagnostic accuracy and treatment outcomes.

Horizontal Active Thrusts and Design of GRS-RW System for Distanced Surcharge (상재하중 이격거리를 고려한 GRS-RW 공법의 토압해석 및 설계)

  • 방윤경
    • Journal of the Korean Geotechnical Society
    • /
    • v.15 no.1
    • /
    • pp.15-29
    • /
    • 1999
  • This study presents an analytical method of estimating the developed horizontal active thrusts against GRS-RW( Geosynthetic Reinforced Soil Retaining Wall) system adapted to the case of distanced surcharge. In addition, the design charts that could be used for preliminary design of GRS-RW system are presented. The proposed method of analysis uses two body translation mechanism as well as force polygon concept. taking into account the effect of facing's rigidity. Besides. the effect of tension cracks in c-\Phi$ soils, seismic effects and horizontal distance from the back face of wall to uniformly distributed surcharge loadings are also included. The results of horizontal active thrusts obtained from the developed method of analysis are compared with those from Jarquio's modified Boussinesq equation.

  • PDF

Validity of Horizontal Reference Planes on Cone-Beam Computed Tomography Generated Postero-Anterior Cephalogram (Cone-beam CT영상으로부터 얻어진 정모두부방사선사진에서 수평기준선의 설정)

  • Kang, Hee-Jea;Kim, Jong-Ryoul;Kim, Yong-Il
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.33 no.4
    • /
    • pp.346-351
    • /
    • 2011
  • Purpose: The purpose of this study was to measure the angular differences between the horizontal reference planes on the CBCT generated PA cephalogram and the modified interpupillary plane, which was usually used in the clinical examination, and to evaluate the validity of the horizontal reference planes. Methods: The CBCT generated PA cephalogram was used to measure the angles between the FH, Lo and IP planes. The subjects consisted of 42 patients with facial asymmetry (males: 21, females: 21, mean-age: 21.6 years). The control groups were also assessed (males: 10, females: 10, mean-age: 23.8 years). The distance of the interpupil was measured on the soft-tissue volume rendered image. The angular differences were statistically analyzed using the $Mann-Whitney$ $U$ $test$ for inter-group comparisons and the $Friedman$ $test$ for intra-group comparisions. Results: The angle between the FH plane and IP plane (the angle of the FH-IP line) showed a statistically significant difference between the two groups ($p$ <0.05). There was no statistical differences between each angle (angle of the FH-IP line, angle of the FH-Lo line, angle of the Lo-IP line) on the intra-group comparision ($p$ >0.05). Conclusion: The angle between the Lo line and IP line (angle of the Lo-IP line) showed no statistically significant difference in both the control and asymmetry groups. Therefore, the Lo line could be used as a horizontal reference plane in CBCT generated PA cephalograms.

Application of Horizontal Barrier on a Rack to Reduce Fire Spread (화재확산 저감을 위한 랙크 내 수평차단막 적용에 관한 연구)

  • Yeo, In-Hwan;Cho, Gyu-Hwan
    • Fire Science and Engineering
    • /
    • v.31 no.4
    • /
    • pp.71-79
    • /
    • 2017
  • A rack warehouse with a vertically loading type and high loading density has severe risks and damage during its fire. In this regard, US and Japan strive to minimize the fire spread by applying in-rack sprinkler, horizontal barriers, etc. corresponding to their own rack warehouse but there is no study and policy in Korea. Therefore, a model scale fire test was carried out targeting the standard rack incorporating the national rack warehouse in order to check fire characteristics in ignition points and installation distances of horizontal barriers in this study. As a result of the test, vertical fire spread of about 30% was inhibited by narrowing its installation distance from 2-layer to 1-layer in an ignition condition of the flue space. In addition, as a result of the measurement of the temperature in the upper and lower parts of the horizontal barrier, the temperature distribution showed about 2~4 higher in a condition with an installation of the barrier than that in the condition without the barrier. Consequently, it is likely that the horizontal barrier will help the initial operation of in-rack sprinkler.

Morphometric characteristics of diploid and triploid Far Eastern catfish, Silurus asotus

  • Park, In-Seok
    • Korean Journal of Environmental Biology
    • /
    • v.38 no.1
    • /
    • pp.106-113
    • /
    • 2020
  • This study identified the differences in the morphometric characteristics of the truss and classical dimensions between diploid and triploid Far Eastern catfish, Silurus asotus, and provided methods for sorting diploid and triploid Far Eastern catfish based on morphometric observations. The significant variables were the direct distance between the anterior edge of the lower lip and the anterior insertion of the dorsal fin(DALAD), the horizontal distance between the anterior edge of the lower lip and the anterior insertion of the ventral fin (HALAV), the direct distance between the anterior edge of the upper lip and the first nostril(DAUF), the direct distance between the anterior edge of the upper lip and the second nostril(DAUS), the interorbital width(IW), and the mandible barbel length (ManBL). The more significant variables were HALAV, DALAD, DAUF, IW, and DAUS. The most useful combination of variables for separating the two groups was DALAD, IW, and DAUF, which correctly classified 85% of the catfish as triploid or diploid, and that percentage was the maximum degree of value possible (p<0.05). Triploid Far Eastern catfish had a high rate of growth in the head region and body depth during the first year after hatching. Triploid Far Eastern catfish had smaller heads and shorter mandible barbels than diploid Far Eastern catfish.

Diopside DSD (crystal size distribution) in the Contact Metamorphic Aureole (Hwanggangni Formation) near the Daeyasan Granite Goesan, Korea (괴산지역 대야산 화강암체 주변 접촉변성대(황강리층)에서의 투휘석 결정 크기분포)

  • Kim, Sangmyung;Kim, Hyung-Shik
    • The Journal of the Petrological Society of Korea
    • /
    • v.5 no.2
    • /
    • pp.161-167
    • /
    • 1996
  • The CSD (crystal size distribution) of diopside crystals in the calc-silicate hornfels of the Hwanggangni Formation intruded by the Cretaceous Daeyasan granite shows the patterns of continuous nucleation and growth. There is correlation between the distance from the intrusion contact and the slopes from the linear part of log(population density) vs. size diagrams. In the log(population density) vs. size diagrams of the samples systematically collected from the intrusion contact, two different groups are recognized; the slopes for the samples near the intrusion contact (horizontal distance from the contact less than 50m) are gentler (1500$cm^{-1}$) than those for the samples away from the intrusion contact (2500$cm^{-1}$, distance from the contact greater than 100 m). These differences may reflect the differences in growth rates and crystallization time, or the differences in diopside-forming reactions. All of the log(population density) vs. size diagrams show depletion of smaller crystals. The observed depletion may be due to Ostwald ripening or the changes in nucleation rates as the reactant phases diminishes. Similar grouping is also possible for the observed degree of depletion of smaller crystals; the depletion decreases with increasing distance from the intrusion contact, suggesting temperature-dependent rates of Ostwald ripening.

  • PDF

Comparison of Experimental and FDS Data for Calculating Heat-Affected Range in Forest Fires (산불 열영향 범위 산정을 위한 실험 및 FDS 데이터 비교)

  • Kim, H.S.;Kang, Y.J.;Kim, J.H.;Kim, K.H.;Lee, B.D.;Kim, Jeong Hun
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.4
    • /
    • pp.91-96
    • /
    • 2014
  • This research deals with the combustion experiment of pine trees, which are the most representative species in Korea. Experimental data are compared with theoretical ones using Fire Simulation Program(FDS). It is considered that horizontal/vertical temperature distribution and radiant heat influence on adjacent areas in fire scenes. The linear function for separation distance to temperature was drawn by applying Stefan-Boltzmann's law; $y=112.13133{\times}({\sigma}T^4)^{-0.52916}$ for calculating the separation distance. In combustion experiment, the radiant heat came to $1.4{\sim}1.5kW/m^2$ in case of the separation distance by one meter. The numerical values mean that human body show the critical level of pain after one minute without a protective equipment.

Passive Ranging Based on Planar Homography in a Monocular Vision System

  • Wu, Xin-mei;Guan, Fang-li;Xu, Ai-jun
    • Journal of Information Processing Systems
    • /
    • v.16 no.1
    • /
    • pp.155-170
    • /
    • 2020
  • Passive ranging is a critical part of machine vision measurement. Most of passive ranging methods based on machine vision use binocular technology which need strict hardware conditions and lack of universality. To measure the distance of an object placed on horizontal plane, we present a passive ranging method based on monocular vision system by smartphone. Experimental results show that given the same abscissas, the ordinatesis of the image points linearly related to their actual imaging angles. According to this principle, we first establish a depth extraction model by assuming a linear function and substituting the actual imaging angles and ordinates of the special conjugate points into the linear function. The vertical distance of the target object to the optical axis is then calculated according to imaging principle of camera, and the passive ranging can be derived by depth and vertical distance to the optical axis of target object. Experimental results show that ranging by this method has a higher accuracy compare with others based on binocular vision system. The mean relative error of the depth measurement is 0.937% when the distance is within 3 m. When it is 3-10 m, the mean relative error is 1.71%. Compared with other methods based on monocular vision system, the method does not need to calibrate before ranging and avoids the error caused by data fitting.