• 제목/요약/키워드: Horizontal and vertical angle

Search Result 514, Processing Time 0.024 seconds

Improvement of Small Wetland and Stream in Cultivated Area in point of Landscape Ecology (경작지 내 소규모 습지 및 소하천의 경관생태적 개선방안)

  • Cho, Hyun-Ju;Ra, Jung-Hwa;Kim, Jin-Hyo
    • Current Research on Agriculture and Life Sciences
    • /
    • v.29
    • /
    • pp.11-19
    • /
    • 2011
  • This research gives weight to establish practical improvement based on analysis of the landscape ecological character and value to realize the importance of small wetland and stream in cultivated areas functioning as a residual landscape element in rural landscape and to deal with ecological depression effectively. The results of summary are as follows. 1) The results of landscape ecological character analysis of wetlands biotop in total of 7 sites, for example, size of surface in site 5 was widely formed about $10,600m^2$, which was assessed satisfactory in terms of slope of waterfront, width of hedgerow, vegetation condition of composition and so on. Also, The number of flexibility showed 2 in site 8-1, the highest, and morphological diversity showed 1.47, the highest. 2) The results of problem analysis of wetland biotop, most of wetlands are analyzed that the width of hedgerow was below 1m. Also, the 4 wetlands in site 8 are appeared that hard to live slope vegetation in there because of slope of waterfronts are above $45^{\circ}$. 3) The results of landscape ecological character analysis of stream in total of 6 sites, for example, width of waterfront in site 4 showed 55m, the widest, and investigated consist of natural ingredients such as soil, rock, gravel. However, width of waterfront in site 2-2 showed 4m, the narrowest, and inclined angle of slope was formed a right angle. 4) The results of problem analysis of stream, width of waterfront hedgerow in site 2-1 showed about 5m, which was very narrower than width of waterfront, and toxic chemicals discharged from near cultivated area without any filtering. Also, all areas of site 2-2 was formed concrete, and was assessed dissatisfactory in terms of capacity of nature purification, flood control, habitat living space because of straight stream. 5) Based on the result above landscape ecological character and problem analysis, main improvement guidelines are set in terms of shape, vegetation, topography in case of wetlands, and which are set in terms of vertical, horizontal structure in case of stream.

  • PDF

Development of Supplemental Equipment to Reduce Movement During Fusion Image Acquisition (융합영상(Fusion image)에서 움직임을 줄이기 위한 보정기구의 개발)

  • Cho, Yong Gwi;Pyo, Sung Jae;Kim, Bong Su;Shin, Chae Ho;Cho, Jin Woo;Kim, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.84-89
    • /
    • 2013
  • Purpose: Patients' movement during long image acquisition time for the fusion image of PET-CT (Positron Emission Tomography-Computed Tomography) results in unconformity, and greatly affects the quality of the image and diagnosis. The arm support fixtures provided by medical device companies are not manufactured considering the convenience and safety of the patients; the arm and head movements (horizontal and vertical) during PET/CT scan cause defects in the brain fundus images and often require retaking. Therefore, this study aims to develop patient-compensation device that would minimize the head and arm movements during PET/CT scan, providing comfort and safety, and to reduce retaking. Materials and Methods: From June to July 2012, 20 patients who had no movement-related problems and another 20 patients who had difficulties in raising arms due to shoulder pain were recruited among the ones who visited nuclear medicine department for PET Torso scan. By using Patient Holding System (PHS), different range of motion (ROM) in the arm ($25^{\circ}$, $27^{\circ}$, $29^{\circ}$, $31^{\circ}$, $33^{\circ}$, $35^{\circ}$) was applied to find the most comfortable angle and posture. The manufacturing company was investigated for the permeability of the support material, and the comfort level of applying bands (velcro type) to fix the patient's head and arms was evaluated. To find out the retake frequency due to movements, the amount of retake cases pre/post patient-compensation were analyzed using the PET Torso scan data collected between January to December 2012. Results: Among the patients without movement disorder, 18 answered that PHS and $29^{\circ}$ arm ROM were the most comfortable, and 2 answered $27^{\circ}$ and $31^{\circ}$, respectively. Among the patients with shoulder pain, 15 picked $31^{\circ}$ as the most comfortable angle, 2 picked $33^{\circ}$, and 3 picked $35^{\circ}$. For this study, the handle was manufactured to be adjustable for vertical movements. The material permeability of the patient-compensation device has been verified, and PHS and the compensation device were band-fixed (velcro type) to prevent device movements. A furrow was cut for head fixation to minimize the head and neck movements, fixing bands were attached for the head, wrist, forearm, and upper arm to limit movements. The retake frequency of PET Torso scan due to patient movements was 11.06% (191 cases/1,808 patients) before using the movement control device, and 2.65% (48 cases/1,732 patients) after using the device; 8.41% of the frequency was reduced. Conclusion: Recent change and innovation in the medical environment are making expensive medical image scans, and providing differentiated services for the customers is essential. To secure patient comfort and safety during PET/CT scans, ergonomic patient-compensation devices need to be provided. Therefore, this study manufactured a patientcompensation device with vertically adjustable ergonomic ROM according to the patient's body shape and condition during PET Torso scan. The defects in the basal ganglia images due to arm movements were reduced, and retaking was decreased.

  • PDF

Full mouth Rehabilitation with Orthognathic Surgery in Facial Asymmetry Patient : Case Report (안면 비대칭환자의 악교정 수술을 동반한 완전구강회복)

  • Im, So-Min;Shin, Hyoung-Joo;Kim, Dae-Gon;Park, Chan-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.3
    • /
    • pp.359-371
    • /
    • 2010
  • Facial asymmetry has been found with a higher frequency (70~84%) in skeletal class III malocclusion patients. Anticipating the poor prognosis of prosthesis due to malocclusion, occlusal stability must be obtained by orthodontic treatment. Moreover, orthodontic surgery would be needed in some severe cases for better functional and esthetic results. The orthognathic surgery is performed on one jaw or two jaw depending on the results of facial diagnosis. Genioplasty may change the vertical, horizontal, sagittal position of chin by osteotomy or augmentation using implants, also. This case is about a 24 year-old male patient who visited our clinic to solve the facial asymmetry and mandibular prognathism. Skeletal class III malocclusion, maxillary canting and menton deviation to left by 13 mm were detected. Multiple ill-fitting prostheses, unesthetic maxillary anterior prostheses, and several dental caries were found. After pre-operative orthodontic treatment, Le-Fort I osteotomy, sagittal split ramus osteotomy, genioplasty, right mandibular angle augmentation were done for the correction of jaw relation and asymmetry. By diagnostic wax-up after post-operative orthodontic treatment, maxillary full mouth rehabilitation and mandibular posterior restorations were planned out. For better result, clinical crown lengthening procedure was done on #11, 12 and implant was placed on left mandibular first molar area. The patient was satisfied with the final prostheses. Because of his high caries risk, long-term prognosis will depend on the consistent maintenance of oral hygiene and periodic follow-up.

Design Anamorphic Lens Thermal Optical System that Focal Length Ratio is 3:1 (초점거리 비가 3:1인 아나모픽 렌즈 열상 광학계 설계)

  • Kim, Se-Jin;Ko, Jung-Hui;Lim, Hyeon-Seon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.4
    • /
    • pp.409-415
    • /
    • 2011
  • Purpose: To design applied anamorphic lens that focal length ratio is 3:1 optical system to improve detecting distance. Methods: We defined a boundary condition as $50^{\circ}{\sim}60^{\circ}$ for viewing angle, horizontal direction 36mm, vertical direction 12 mm for focal length, f-number 4, $15{\mu}m{\times}15{\mu}m$ for pixel size and limit resolution 25% in 33l p/mm. Si, ZnS and ZnSe as a materials were used and 4.8 ${\mu}m$, 4.2 ${\mu}m$, 3.7 ${\mu}m$ as a wavelength were set. optical performance with detection distance, narcissus and athermalization in designed camera were analyzed. Results: F-number 4, y direction 12 mm and x direction 36 mm for focal length of the thermal optical system were satisfied. Total length of the system was 76 mm so that an overall volume of the system was reduced. Astigmatism and spherical aberration was within ${\pm}$0.10 which was less than 2 pixel size. Distortion was within 10% so there was no matter to use as a thermal optical camera. MTF performance for the system was over 25% from 33l p/mm to full field so it was satisfied with the boundary condition. Designed optical system was able to detect up to 2.9 km and reduce a diffused image by decreasing a narcissus value from all surfaces except the 4th surface. From sensitivity analysis, MTF resolution was increased on changing temperature with the 5th lens which was assumed as compensation. Conclusions: Designed optical system which used anamorphic lens was satisfied with boundary condition. an increasing resolution with temperature, longer detecting distance and decreasing of narcissus were verified.