• Title/Summary/Keyword: Hop test

Search Result 67, Processing Time 0.023 seconds

A Study on how to Utilize the DR System using Assistive Devices (보조기구를 이용한 DR System 활용 방법에 대한 연구)

  • Seon-Yeol, Seo;Jeong-Ho, Kim;Jin-Ok, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.115-122
    • /
    • 2023
  • The hip joint device is an important immobilization device for internal rotation in the diagnosis of bone density test, microfracture, and arthritis. These fixing mechanisms have limitations in maintaining reproducibility due to the use of Velcro. In this study, we developed an improved hip joint device and evaluated its usefulness. For 30 students enrolled in the Department of Radiology, we evaluated the reproducibility through medical imaging and the time required for positioning by applying the conventionaling and improved device. Changes over time were also evaluated. As a result, compared to the conventional device, the improved device showed a 32% reduction in positioning time and improved reproducibility by about 6.2 times. As for the amount of change over time, the positioning time increased in the conventional device, but decreased in the improved device, and the reproducibility of the conventional device was lower than that of the improved device. Through this, it can be said that the use of the improved device improved the image quality and reduced the radiologist's workload.

Plant Virome Analysis by the Deep Sequencing of Small RNAs of Fritillaria thunbergii var. chekiangensis and the Rapid Identification of Viruses

  • Chen, Lu-xi;Pan, Hang-kai;Tao, Yu-tian;Yang, Dang;Deng, Hui-min;Xu, Kai-jie;Chen, Wen-bin;Li, Jun-min
    • The Plant Pathology Journal
    • /
    • v.38 no.5
    • /
    • pp.533-540
    • /
    • 2022
  • Thunberg fritillary (Fritillaria thunbergii), a perennial used in traditional Chinese herbal medicine, is a members of the family Liliaceae. The degeneration of germplasm is a severe problem in the production of Fritillaria thunbergii var. chekiangensis. However, no information about viral infections of F. thunbergii var. chekiangensis has been reported. In this study, we sequenced the small RNAs of F. thunbergii var. chekiangensis from leaves and bulbs, and viruses were identified using a phylogenetic analysis and BLAST search for sequence. In addition, multiplex reverse transcriptase-polymerase chain reaction (RT-PCR) was used to rapidly detect viruses in this variety. Our study first reported that five viruses infected F. thunbergii var. chekiangensis. Among them, fritillary virus Y (FVY), lily mottle virus (LMoV), Thunberg fritillary mosaic virus (TFMV), and hop yellow virus (HYV) had been reported in F. thunbergii, while apple stem grooving virus was first reported in the genus Fritillaria. A multiplex RT-PCR method was developed to rapidly test the four viruses FVY, LMoV, TFMV, and HYV in F. thunbergii var. chekiangensis. Our results provide a better understanding of the infection of F. thunbergii var. chekiangensis by viruses and a basic reference for the better design of suitable control measures.

ACL reconstruction with autologous hamstring tendon - Short term clinical result using new femoral suspensory fixation device 'Cross Pin' and graft tensioner for maintaining a constant tension- (자가 슬괵건을 이용한 전방 십자 인대 재건술 - 새로운 대퇴부 현수고정법인 Cross Pin과 일정한 긴장력 유지를 위한 Graft Tensioner 사용의 단기 추시 결과 -)

  • Seo, Seung-Suk;Kim, Chang-Wan;Kim, Jin-Seok;Choi, Sang-Yeong
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.10 no.1
    • /
    • pp.27-34
    • /
    • 2011
  • Purpose: To evaluate the short term clinical result of ACL reconstruction with autologous hamstring tendon using Cross pin and Graft Tensioner and to seek way to resolve the experienced technical problems. Materials and Methods: From January 2008 to March 2009, 35 patients who had been treated arthroscopic ACL reconstruction were enrolled. The femoral side of ACL graft was fixed with Cross pin. The tibial side of graft was fixed with Intrafix and post-tie. The graft was tensioned with Graft Tensioner at 80N. We analyzed the clinical, radiographic results and complications. Results: IKDC subjective score and Lysholm score improved to 89.1 and 91.4 points. Also, Pivot shift test and One-leg hop test showed good results postoperatively. Side to side difference using KT-1000 arthrometer and Telos stress radiography improved compared with normal limb to $2.8{\pm}1.6$ mm and $2.6{\pm}1.3$ mm, respectively. The femoral tunnel enlarged to $2.3{\pm}1.1$ mm. Soft tissue irritation and femoral tunnel-graft harness length mismatch, femoral tunnel-cross pin tunnel mismatch were happened as peri-operative complications. Conclusion: Using of Cross pin and Graft Tensioner for ACL reconstruction with hamstring tendon is one of the good method for obtaining stability in short-term clinical result. But to reduce femoral tunnel-cross pin mismatch, it needs to shorten femoral bone tunnel and to create cross pin tunnel as vertical as possible. And to reduce femoral tunnel-graft harness mismatch, it needs to advance position rod further 3 mm when to create femoral tunnel.

  • PDF

Novel Balance Tests for Assessing Functional Ankle Instability: Relationships with BMI and Gender (기능적 족관절 불안정성을 평가할 수 있는 새로운 균형 평가법: 체질량 지수와 성별과의 연관성)

  • Patankar, Harshad P.;Yeo, Eui-Dong;Kim, Seung-Joo;Lim, Hong-Chul;Hwang, Myong-Hoi;Park, Se-Hyun;Kim, Hak-Jun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.16 no.2
    • /
    • pp.128-134
    • /
    • 2012
  • Purpose: To design novel balance tests to assess FAI and evaluate whether these tests are affected by BMI or gender, with the goal of developing reliable FAI assessment tests that are not influenced by these factors. Materials and Methods: Participants included 20 young, healthy volunteers, 12 males and 8 females, with a mean age of $24{\pm}4$ years and a mean BMI of $23{\pm}2.28$. None of the subjects had known ankle instability. The following tests were assessed in each participant: single leg balance (SLB), percentage of leg press (PLP), single leg cycling (SLC), one leg squat (OLS), multiple direction reach-front/back/side (MDR-F/B/S), single leg hop (SLH), two leg jump (TLJ) and side step (SS). Data were analyzed using the SPSS 12.0 software program with ANOVA and t-test used. Results: When grouped by BMI, we found that despite differences in BMI, the performances of all subjects were equivalent except for the one-leg-squat test, for which the mean ratios for underweight ($1.69{\pm}0$), normal weight ($1.05{\pm}0.19$), and overweight ($0.93{\pm}0.30$) individuals were significantly different (p=0.02); ratios for SLB (p=0.273), SLC (p=0.903), PLP (p=0.664), MDR-F/B/S (p=0.498, 0.908, and 0.503, respectively), SLH (p=0.332) were not significantly different. When calculated according to gender, we found that the OLS (p=0.013) and MDRS (p=0.034) were significantly different, while parameters for all the remaining tests were not affected. Conclusion: We found that the SLB, PLP, SLC, MDR-F/B, and SLH ratios were unaffected by BMI or sex and, therefore, are reliable parameters for assessing ankle instability.

Development of Multipoint Simultaneous Full-duplex Team Communication Module for SCBA (SCBA 면체용 다자간 동시 양방향 팀 통신모듈 개발)

  • Kim, Si-Kuk;Choi, Su-Gil;Lim, Woo-Sub;Han, Yong-Taek
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.165-172
    • /
    • 2019
  • This study presents the design and manufacture of a self-contained breathing apparatus SCBA wireless communication module with a multipoint simultaneous full-duplex communication system to enable communication between team members wearing the SCBA system. It is necessary for fire-fighters to wear the SCBA system during extinguishing and rescue work at the fire site. Evaluation of the team communication module confirmed the feasibility of communication over more than 500 m in the test condition based on the line of sight. By implementing the Ad-hoc function, it was confirmed that the communication distance could be extended to 128 m by automatic routing up to 3 hoc. The vertical distance inside the building for successful communication was up to the 5th floor in the open staircase and up to the 3rd floor in the partitioned staircase. Furthermore, the performance testing of the communication module assuming a fire situation, confirmed that five team members correctly recognized the standard abbreviation of fire and wireless communication without a separate PTT key operation. In addition, the flame resistance was verified by exposing the module to a flame at 950 ± 50 ℃ for 5 s and then immediately extinguishing the flame.

The Effects of Active Movement Myofascial Decompression Therapy and Static Myofascial Decompression Therapy on Range of Motion, Muscle Strength, Functional Movement in Young Adults. (젊은 성인에서 능동 움직임을 결합한 근막감압치료 적용과 정적 적용이 관절가동범위, 근력, 기능적 움직임에 미치는 영향)

  • Lee, Jee-Hyun;Kim, Tae-Hyeon;Kang, Si-Yun;Kum, Do-Gun;Lee, Sung-Yeon;Do, Kwang-Sun;Kim, Chang-Sook;Bae, Ju-Han;Park, Jun-Hyuck;Kim, Jae-Eun
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.9 no.3
    • /
    • pp.165-173
    • /
    • 2021
  • Purpose : Myofascial decompression is frequently mentioned as a method applied to cupping. The purpose of this study is to evaluate and compare active range of motion (AROM), muscle strength, and functional movement by applying myofascial decompression to the hamstrings. Methods : This study evaluated AROM, muscle strength, and functional movement by applying active movement myofascial decompression and static myofascial decompression to the dominant leg, respectively, in a crossover design conducted with normal adults (n=21) in their average 20s enrolled at G University in G city, Gyeongsangbuk-do. Active movement myofascial decompression was implemented for five minutes at a rate of 100 bpm to make the beats in flexion and extension respectively. Static myofascial decompression was only performed for five minutes while at rest. All of these interventions were performed at a cupping depth of two mm. After a one-week washout period, static was applied again to compare the same dependent variables. Results : Regarding AROM and muscle strength, both groups showed significant differences in the before and after results (p<.05). However, in the Functional Reach Aspect and Single Leg Hop test, the active movement myofascial decompression group showed better results. There was no statistical difference between the Active movement myofascial decompression group and Static myofascial decompression group in any dependent variable (p<.05). Conclusion : As a result of this experiment, both active movement myofascial decompression and static myofascial decompression had a positive effect on dependent variable. Therefore this study is meaningful in that it is easier and simpler to see the effect on flexibility, muscle strength, and functional movement just by implementing movement myofascial decompression.

THE CHANGE OF CANAL CONFIGURATION AFTER INSTRUMENTATION BY SEVERAL NICKEL-TITANIUM FILES IN THE SIMULATED CANAL WITH ABRUPT CURVATURE (수종의 엔진구동형 니켈-타이타늄 파일에 의한 급한 만곡의 근관 성형시 근관형태 변화에 대한 비교연구)

  • Lim, Jung-Jang;Kim, Dong-Jun;Hwang, Yun-Chan;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.4
    • /
    • pp.303-311
    • /
    • 2005
  • The purpose of this study was to evaluate which type of Ni-Ti files are able to maintain canal configuration better in the simulated canal with abrupt curvature near it's apex. Ninety six simulated root canals were made in epoxy resin and $\sharp$15 finger spreader was used as root canal templates. The simulated root canals were made with radius of curvature of 1.5mm, 3.0mm, 4.0mm, 6.0mm respectively and the angle of curvature of all simulated canals were adjusted to 90 degree. The simulated canals were instrumented by ProFile, ProTaper, Hero 642, and $K^3$ at a 300 rpm using crown-down pressureless technique. Pre-instrumented and post-instrumented images were taken by digital camera and were superimposed with Adobe Photos hop 6.0 program. Images were compared by image analysis program. The changes of canal width at the inner and outer side of the canal curvature. canal transportation were measured at 9 measuring point with 1 mm interval. Statistical analysis among the types of Ni-Ti files was performed using Kruskal-Wallis test and Mann-Whitney U-test. The result was that ProFile maintain original canal configuration better than other engine driven Ni-Ti files in the canals above 3.0mm radius of curvature, and in the 1.5mm radius of curvature, most of Ni-Ti flies were deformed or separated during instrumentation.