• Title/Summary/Keyword: Holter electrocardiography

Search Result 5, Processing Time 0.018 seconds

Detection of Arrhythmias by Holter Monitoring and Use of Wearable Electrocardiography Devices Holter and wearable devices for arrhythmia detection

  • Ji Yeon Chang;Jae Kyung Kim
    • International Journal of Advanced Culture Technology
    • /
    • v.11 no.2
    • /
    • pp.310-314
    • /
    • 2023
  • In this paper, we show that the limitations of Holter monitoring and Wearable Electrocardiogarphy Devices and their arrhythmia detection. Sudden death caused by cardiovascular disease, often referred to as the "silent killer" due to its unpredictable nature, is a major health concern. Electrocardiography (ECG) is a basic diagnostic tool for detecting heart disease, but its limitations make it difficult to detect arrhythmia, a significant indicator of an irregular heart state. To address this limitation, a long-term continuous ECG recording device has been developed, Holter ECG device and wearable device. A significant number of studies have focused on the differences between Holter monitoring and wearable devices. The Holter tests were useful for detecting regularly occurring arrhythmias, whereas wearable patches were better at detecting random and infrequent arrhythmias. Wearable patches were effective in detecting episodes of arrhythmia and myocardial ischemia. Despite the concern, wearable devices had less signal loss than Holter monitoring and patients also preferred wearable devices over Holter monitoring due to convenience. These results could mean that the wearable devices can perfectly replace the Holter test.

Evaluation of the Diagnostic Performance and Efficacy of Wearable Electrocardiogram Monitoring for Arrhythmia Detection after Cardiac Surgery

  • Seungji Hyun;Seungwook Lee;Yu Sun Hong;Sang-hyun Lim;Do Jung Kim
    • Journal of Chest Surgery
    • /
    • v.57 no.2
    • /
    • pp.205-212
    • /
    • 2024
  • Background: Postoperative atrial fibrillation (A-fib) is a serious complication of cardiac surgery that is associated with increased mortality and morbidity. Traditional 24-hour Holter monitors have limitations, which have prompted the development of innovative wearable electrocardiogram (ECG) monitoring devices. This study assessed a patch-type wearable ECG device (MobiCARE-MC100) for monitoring A-fib in patients undergoing cardiac surgery and compared it with 24-hour Holter ECG monitoring. Methods: This was a single-center, prospective, investigator-initiated cohort study that included 39 patients who underwent cardiac surgery between July 2021 and June 2022. Patients underwent simultaneous monitoring with both conventional Holter and patchtype ECG devices for 24 hours. The Holter device was then removed, and patch-type monitoring continued for an additional 48 hours, to determine whether extended monitoring provided benefits in the detection of A-fib. Results: This 72-hour ECG monitoring study included 39 patients, with an average age of 62.2 years, comprising 29 men (74.4%) and 10 women (25.6%). In the initial 24 hours, both monitoring techniques identified the same number of paroxysmal A-fib in 7 out of 39 patients. After 24 hours of monitoring, during the additional 48-hour assessment using the patch-type ECG device, an increase in A-fib burden (9%→38%) was observed in 1 patient. Most patients reported no significant discomfort while using the MobiCARE device. Conclusion: In patients who underwent cardiac surgery, the mobiCARE device demonstrated diagnostic accuracy comparable to that of the conventional Holter monitoring system.

Nonlinear analysis of cardiotonic effect of acupuncture treatment on heart rate variability assessed by 24-hour Holter monitoring (침처치의 24시간 심박변이도 영향에 대한 비선형 분석)

  • Oh, Dal-Seok;Lee, Jeon;Kim, Jong-Yeol;Choi, Sun-Mi
    • Korean Journal of Oriental Medicine
    • /
    • v.14 no.1
    • /
    • pp.85-89
    • /
    • 2008
  • This study is to investigate cardiotonic effect of acupuncture on heart rate variability(HRV) analyzed by a nonlinear way(DFA, Detrended Fluctuation Analysis). It was designed as a randomized, single-blind, waiting list-controlled, cross-over study. We assessed heart rate and R-R intervals in Circadian electrocardiography with a Holter monitoring device for twelve hospitalized participants. The compatible analytical program, Zymed, was used for generating the signals of R-R intervals from 24 hour-ECG. In DFA analysis, we produced DFA alpha 1, alpha 2 parameters according to the process of Cygwin module of Linux server. We tested if there was any difference between HRV parameters using SPSS, a statistical package. There was no difference between acupuncture and no treatment group in DFA alpha 2 parameter {95% Confidence Interval (-)0.058 - 0.037, P = .565}. Two group all showed large intra-individual variations. Consequently, acupuncture treatment did not modulate the complexity of HRV in a DFA analysis. This study can be a rationale for acupuncture's properties on cardiovascular and autonomic systems.

  • PDF

Assessment of covariate-effect of sleeping behavior on heart rate variability during a clinical trial (임상시험 중 수면행위가 심박변이도에 미치는 영향 분석)

  • Lee, Jeon;Oh, Dal-Seok;Lee, Hae-Jung;Choi, Sun-Mi;Kim, Jong-Yeol
    • Korean Journal of Oriental Medicine
    • /
    • v.13 no.3
    • /
    • pp.97-103
    • /
    • 2007
  • The object of this study is to evaluate confounding effect of sleeping behavior on heart rate variability (HRV) in healthy volunteers during a randomized clinical trial. From 6 healthy volunteer, we acquired circadian electrocardiography(ECG) with a Holter monitoring device(DigiTrak Plus, Philips). The compatible analytical program, Zymed, was used for calculation of RR intervals of 24h ECG signal. Then, we generated HRV signals and calculated 9 HRV parameters in time domain and frequency domain for every 30 minute with Matlab 6.x software. We also encoded participants' activities as follows; stable condition(1), sleeping behavior(2), eating behavior(3), and undefined condition(4). Using SPSS 12.0, we tested if there was any difference between HRV parameters of day-time and night-time and between those of a subject in stable condition and in sleeping behavior. As a result, one of the most important parameter-LF/HF ratio, which indicates the autonomic balance between sympathetic and parasympathetic nervous systems, as same the other parameters, showed large inter-individual variations in circadian profiles. And, the mean LF/HF ratio of each participant was different between in stable condition and in sleeping behavior (p<.05). Consequently, the effect of sleeping behavior must be considered when one or more of HRV parameters, especially LF/HF ratio, are used as assessment index in clinical studies.

  • PDF

Analysis of Data Transmission Rate and Power Consumption in Zigbee Based Electrocardiography (지그비 기반 심전계의 데이터 전송률과 소비 전력 분석)

  • Kim, Nam-Jin;Hong, Joo-Hyun;Lee, Tae-Soo
    • The Journal of the Korea Contents Association
    • /
    • v.6 no.12
    • /
    • pp.96-104
    • /
    • 2006
  • In this study, data transmission ratio and power consumption issues of Zigbee based sensor module and personal digital assistant(PDA) were addressed to develop ECG telemetry device. PDA processes the data transmitted through serial port using non-blocking method. The transmission rate was dependent on the packet structure. It was 300 ECG samples/sec, when each packet was composed of 2 ECG data and 3-axial acceleration vector. Using two AAA batteries in series, operating time of the wireless sensor module was above 28 hours in average. Power consumption of PDA was dependent on screen ON/OFF condition and serial port usage. In this application, operating time of PDA was 5 hours in average. In conclusion, there was no problem in the power consumption of wireless sensor module and transmission rate, when the developed device was used as 24 hour Holter device. But, PDA has the problem of power consumption, which should be solved.

  • PDF