• Title/Summary/Keyword: Holographic Interferometry

Search Result 86, Processing Time 0.02 seconds

The Measurement Method of Small Deformation by using Holographic Interferometry (홀로그래픽 산섭법을 이용한 미소변형 측정법)

  • 강영준;문상준;최장섭
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1993.10a
    • /
    • pp.273-278
    • /
    • 1993
  • Conventional measurement methods for non-destructive testing(NDT) in nuclear power plants other industrial plants have been performed as the methods of contact with objects to be inspect, but those methods have been taken relatively much time to be inspected. Holographic interferometry which is a non-contact optical measurement method using a coherent light can overcome these demerit, and also has an advantage that the quantitative measurement of small deformation for large areas can be accomplished at a time with high precision. In this paper the comparisons of the experimental results from holographic interferometry with those form the finite element method(FEM) and the analytical solutions of elastic equation are discussed.

  • PDF

A Study on the Vibration Characteristics of Stiffened Cylinder (보강된 실린더의 진동특성에 관한 연구)

  • Kim, Gwang-Rae;Jang, Yong-Hun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.3
    • /
    • pp.408-414
    • /
    • 2001
  • The structural characteristics of the stiffened double cylinder was investigated through experiment and analysis. The outside cylinder was excited with piezoelectric actuator and the mode shape of the cylinder with stiffening T frame was obtained by using holographic interferometry. Finite element method was applied for further modal investigation of the stiffened cylinder. The experimental results showed that the mode shape of cylinder was dependent on the exciting frequencies and the T frame showed salient effect of damping at most of the resonent frequencies. In particular frequencies, the T frame worked as a transmitter. FFM showed similar results with the experiments. This paper showed that the laser-based method such as holographic interferometry is well suited for investigation of the whole-field mode shapes and FEM has good performance to estimate the medal characteristics of the mechanical structure.

The study of mixed convection in a rectangular enclosure for indoor air control (실내공기 제어를 위한 사각공간내의 혼합대류에 관한 연구)

  • 이철재;정한식;권순석
    • Journal of Ocean Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.109-117
    • /
    • 1996
  • The numerical and experimental studies on the mixed convection of a rectangular enclosure for indoor air control has been studied numerically using the finite volume method and experimentally with holographic interferometry and Laser apparatus. The parameters studied here are Pr= 0.71, $30{\leq}Re{\leq}600$, $700{\leq}Gr{\leq}100000$ and the positions of an outlet. The results show streamlines, isothrems, velocity distributions and photograph of holographic interferometry and streamlines. It is found that the minimum cell occurs at Re=100, Gr=10000. The mean Nusselt numbers can be expressed by the correlation equation $Nu=C{\cdot}Gr^a$ $Re^b.$ The comparison of numerical and experimental results shows a good agreement.

  • PDF

The measruement method for internal defect of pressure vessels by using holographic interferometry (홀로그래픽 간섭법을 이용한 압력용기의 내부결함 측정법)

  • 문상준;강영준;최장섭
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.04b
    • /
    • pp.377-382
    • /
    • 1995
  • Conventional measurement methods using ultrasonic wave or x-ray, eddy current for non-destructive testing(NDT) in nuclear power plants and other industrial plants have been performed as the method of contact with objects to be inspected. With this reason these methods have been taken relatively much time and the inspected area is limited by the location of probe or film. But holographic interferometry which is a non-contact optical measurement method using a coherent light source has an advantage that the quantitative measurement can be performed at a time. In this paper a new method using holographic interferometry and image processing for detecting internal flaws of pressure vessels is presented.

  • PDF

A Study on the Double Exposure Holographic Interferometry for Dental Science (치의학을 위한 이중노출 홀로그래피 간섭기법 연구)

  • Gil, S.K.;Kang, H.S.;Choi, P.S.;Park, H.K.
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.418-421
    • /
    • 1988
  • Holographic interferometry is applied in dental research to study the motion of teeth and the deformation of the associated facial structure. We consider double exposure holographic interferometry which has limiting factors such as the stability of fringes, the recording time, the amount of exposure, the localization of fringes and sensitivity. These factors are taken into account to make interferogram. The resulting interferogram gives fringe pattern which is analyzed qualitatively to determine the relative rotation and the deformation of the facial structure.

  • PDF

Measurement of 3-D Deformation by Using Holospeckle Interferometry (홀로스펙클 간섭법을 이용한 3차원 변형측정 연구)

  • 박승옥;권영하;유성규
    • Korean Journal of Optics and Photonics
    • /
    • v.1 no.1
    • /
    • pp.12-15
    • /
    • 1990
  • Holospeckle interferometry, the combined technique of holographic interferometry and speckle photography, was applied to the measurement of 3-D contact deformation created by an indentor. This new tech$.$ nique makes possible to measure both in-plane and out-of-plane displacements from one photographic plate. In this study, the optical system based on image holography was set up. In order to enhance the size and the contrast of the speckle, a proper magnification and a low reference beam ratio was used as compared with the conventional holographic interferometry technique. This system shows the magnified and clear holographic interference fringe as well as Young's fringe patterns.tterns.

  • PDF

Measurement Method of the Vibration Mode Shapes Using Electro-Optic Holographic Interferometry (전자 광학적 훌로그래픽 간섭법을 이용한 진동물체의 모드형태 계측법)

  • Choi, Jang-Seob;Kang, Young-June
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.2
    • /
    • pp.564-574
    • /
    • 1996
  • This paper describes as Electronic Speckle Pattern Interferometry system which has been designed for measuring vibration patterns and quantitative measurement of vibration amplitude fields by using the time average method on a object. Visbility of fringe patterns is more improved by using the phase stepping and frame average method to reduce speckle and electric noise. And a bias vibration is introduced into the reference beam to shift the $\frac{2}{0}$ fringes so that fringe shift algorithms can be used to determine vibration amplitude. The experimental results are compared to those of the FFT analyzer and the FEM model analysis.

Vibration Analysis of Loudspeaker by Using Electronic Speckle Pattern Interferometry (전자 스페클 간섭계에 의한 스피커 진동 해석)

  • 김정규;노경완;강영준;김동우
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.356-361
    • /
    • 1996
  • Nowadays, Electronic Speckle Pattern Interferometry is a well established measuring technique with a wide range of industrial applications, particularly in the fields of deformation measurement and vibration analysis. Comparing with holographic inteferometry, it has some attractive features, which are rapid recording and reconstruction, satisfiable automation etc. Time-average ESPI was used to provide vibration mode shape of an object whose vibration amplitude is given as a fringe pattern. However, it is not possible to determine the direction of motions of a point on the object at any given time, because time-average method does not give any information about the phase of vibration. A better technique is stroboscopic method which can measure the amplitude and phase of vibrating surface. In this paper, loudspeakers were tested by these two methods and the mode shape and amplitude of vibration were visualized. As measured results, we can assume that these techniques will be applied directly in the loudspeaker industry.

  • PDF

A STUDY OF HOLOGRAPHIC INTERFEROMETRY ON THE INITIAL REACTION OF MAXILLOFACIAL COMPLEX TO THE INTERMAXILLARY FORCES ON THE ORTHODONTIC ARCHWIRES (교정용 호선에 악간 교정력 적용시 악안면골의 초기반응에 관한 Holographic Interferometry 연구)

  • Jin, Ik-Jae;Yang, Won-Sik
    • The korean journal of orthodontics
    • /
    • v.24 no.2
    • /
    • pp.447-476
    • /
    • 1994
  • This study was performed to evaluate the initial reaction of maxillofacial complex to the Class II intermaxillary and the anterior vertical elastic forces on the six types of archwires including multiloop edgewise arch wires(MEAW). A human dry skull was used for this purpose and this investigation was done by holographic interferometry. Based on such investigation, the fringe pattern and the number of fringes of each condition were compared and analyzed. The findings of this study were as follows: 1. As the orthodontic forces increased, the amount of displacement increased. 2. As the orthodontic forces were applied, the fringes were shown not only in the teeth and the maxilla but also in the adjacent bones, i.e., temporal bone, zygomatic bone, nasal bone, frontal bone and sphenoid bone. And the direction of fringe pattern and the number of fringes were different from each other by the sutures. 3. As the long Class II elastic forces were applied, the backward-downward displacements of the anterior teeth and the maxilla were shown, and backward displacement of the former were grater than those of the latter. And backward displacements were greater by the long Class II elastic forces than by the short Class II elastic forces. 4. As the anterior vertical elastic forces were applied, downward displacements of the anterior teeth and the maxilla were shown, and the downward displacements of the former were greater than those of the latter relatively. 5. The downward displacements of the anterior area to the anterior vertical elastic forces of the MEAW were greater than those of other archwires. In addition, the more tip-back bend was applied, the more displacement was seen. 6. As the Class II intermaxillary forces and the enough anterior vertical elastic forces were applied on the MEAW with tip-back bend, there was an intrusive effect of the posterior teeth.

  • PDF

Holospeckle interferometry for measureen of 3-D displacement (3차원 변위측정을 위한 홀로스펙클 간섭법)

  • 박승옥
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1990.02a
    • /
    • pp.131-135
    • /
    • 1990
  • The combined technique of holographic interferometry and speckle photography, so called holospeckle interferometry, has been attention for the measurement of 3-D displacements. This new technique enables the researcher to obtain information of in plane and out-of plane displacements from one photographic plate. There is room for further development of special optical arrangement in order to apply holospeckle interferometry in specific field. In this study, the enlarged fringe pattern was obtained by specifical optical arrangement.

  • PDF