• Title/Summary/Keyword: Hollow Fiber

Search Result 631, Processing Time 0.023 seconds

Membrane Contactors for Water Carbonation

  • Alessandra Criscuoli;Enrico Drioli
    • Membrane Journal
    • /
    • v.1 no.1
    • /
    • pp.59-59
    • /
    • 1991
  • A theoretical and experimental study made in order to determine the performance of mem-brane contactors in water carbonation is presented. In particular on the basis of experimental results pre-viously obtained it has been derived an expression in which the effect of some parameters as temprera-ture water and CO₂ flow rate CO₂ pressure trans-membrane pressure on the performance of the process is taken into account. The study refers to hollow fiber membrane contactors used for the experimental tests. The main scope has been to verify if by membrane contactors it is possible to reach the same de-gree of water carbonation as by trditional methods (1-5 g/1) and to derive for the module used a cor-relation able to describe the performance of the process at several operating conditions. The high CO₂ removal observed confirms the interesting potentialties of membrane contactors also in gas streams purification.

Preparation of $\gamma-LiAlO_2$ Short Fibers by the Sol-Gel Method (졸-겔법에 의한 $\gamma-LiAlO_2$ 단섬유의 제조)

  • 현상훈;이재현;홍성안
    • Journal of the Korean Ceramic Society
    • /
    • v.33 no.10
    • /
    • pp.1079-1088
    • /
    • 1996
  • Discontinuous ${\gamma}$-LiAlO2 fibers for fiber-reinforcing MCFC matrixes have been produced by the sol-gel process using the centrifugal spinning apparatus of the Rotary type. Gel fibers could be obtained through spinning of stable LiAlO2 complex polymetric sols under the optimum spinning conditions (hollow-disc rotating velocity 9000 rpm sol feeding rate of 4ml/min flowing N2 temperature of 4$0^{\circ}C$ and flowing N2 pressure of 4 bar). It was found that defect free and densified ${\gamma}$-LiAlO2 fibers with the relative density of 98% and the mean diameter of 4.7${\mu}{\textrm}{m}$ were prepared when the spinned fibers were heat-treated to 100$0^{\circ}C$ on the specified heating schedule. in particular the mean diameter and length of fibers could be controlled by the pressure of flowing N2 and the chopping-sieving method respectively.

  • PDF

Purification and characterization of glucosyltransferase and fructosyltransferase from Leuconostoc mesenteroides NRRL B-1149

  • Park, Jun-Seong;Park, Hyeon-Jeong;Lee, So-Yeong;Kim, Do-Won;Kim, Do-Man
    • 한국생물공학회:학술대회논문집
    • /
    • 2002.04a
    • /
    • pp.188-191
    • /
    • 2002
  • A glucan and a fructan producing enzymes from Leuconostoc mesenteroides NRRL B-1149 were prepared and concentrated from the cu1ture of 1.5% sucrose using polysulfone ultrafiltration hollow fiber in the presence of 0.1% (w/v) Tween 80, 1 mM $CaCl_2$, and 0.02% $NaN_3$. The molecular masses of the enzymes were estimated to be about 213.6 kDa and 180 kDa, respectively, based on the PAS staining for the glucosyltransferase and Mukasa method for fructosyltransferase. Polymers produced by the enzymes showed different solubility; an insoluble glucan and a soluble fructan. The linkages of polymers were determined by methylation using Hakomori reagent and following acid hydrolysis. The glucan was composed of ${\alpha}$-1,6 and 1,3 linkages and the fructan showed similar linkage data of levan.

  • PDF

A Survey of water pollution and the development of water treatment system on agricultural Area (농어촌의 수질오염과 수질특성에 적합한 정수 처리시스템의 개발에 관한 연구(1))

  • 정문호;김영규;조태석;배현주;신명옥;김수연;김민지;김민영;김수복
    • Journal of environmental and Sanitary engineering
    • /
    • v.12 no.2
    • /
    • pp.65-74
    • /
    • 1997
  • The purpose of this study was to investigate the removal effect and variation of contaminated water by various water treatment processes using sediment filter, activated carbon, photocatalysis, reverse osmosis, ultra violet sterilizer and ultra filtration. The removal effect of chloride and trace metal was low by activated carbon and ultra filter but high in reverse osmosis. The removal effect of bacteria and E. coli was low by activated carbon and membrane filter system using activated carbon but high in impregnated activated carbon. The removal effect of TCE was low in sand and ultra filter system as compared with activated carbon. Ultra filtration process was effective for purify agricultural water without E.coli. Reverse osmosis was effective to remove heavy metal and activated carbon was effective to remove halogenated organic chemical compound. The flux and the removal effect of COD in spiral wound ultrafilter were higher than the hollow fiber ultrafilter.

  • PDF

Structural optimizations of the optical fiber hydrophones with the hollow mandrel: Part I. Effects of the foraming layer on the wave propagation and the sensitivity (중공형 멘드릴을 이용한 광섬유 하이드로폰의 최적 구조 설계 Part I. Forming 층이 음파 전달 및 감도에 미치는 영향)

  • 임종인;노용래
    • The Journal of the Acoustical Society of Korea
    • /
    • v.17 no.4
    • /
    • pp.23-29
    • /
    • 1998
  • 본 논문은 foraming층이 음파의 전달 특성에 미치는 영향 및 멘드릴형 광섬유 하이 드로폰의 광음향 감도 특성에 미치는 영향을 분석한 것이다. 유한 요소법을 이용하여 foaming층의 내부 구조에 따른 음파의 전달 특성을 분석하였고, AL(Aluminium)/foaming 및 Nylon/foaming 멘드릴(mandrel) 각각에 대하여 foaming층의 재질 및 두께 변화에 따른 광음향감도 변화를 분석하였다. 그 결과, foaming층 내의 구조변화의 영향을 무시할 수 있 었다. 또한 AL al cNylon층상 복합체인 멘드릴에서 foaming층의 탄성율이 낮을수록, 두께 가 증가할수록 공음향 감도는 증가하였다. 그러므로 1GPa 이하의 탄성율을 지닌 두꺼운 Foaming층을 사용하여 층상 복합체 멘드릴을 구성하는 것이 광음향 감도의 향상을 위하여 효율적이다.

  • PDF

Structural optimizations of the optical fiber hydrophones with the hollow mandrel: Part II. The hydrophone's sensitivity with the mandrel's geometry (중공형 멘드릴을 이용한 광섬유 하이드로폰의 최적 구조 설계 Part II. 멘드릴의 형상 에 따른 광음향 감도 특성)

  • 임종인;노용래
    • The Journal of the Acoustical Society of Korea
    • /
    • v.17 no.4
    • /
    • pp.30-37
    • /
    • 1998
  • 본 논문은 중공형 층상 복합체 멘드릴(mandrel)을 이용하여 기본 공진주파수가 15kHz이상이고, 우수한 감도 특성을 지닌 광섬유 하이드로폰의 최적 구조를 설계하는 것에 관한 것이다. 유한요소법을 이용하여 Al/foraming 및 Nylon/foaming층상 복합체의 공지주 파수를 분석하여 설계 변수의 범위를 결정하였고, 멘드릴 형상에 따른 광음향 감도 특성을 분석하여 최적구조를 결정하였다. 그 결과로 멘드릴의 외경이 감소할수록, 길이가 증가할수 록 감도가 향상되었다. AL 멘드릴의 경우, 내경/외경 비가 낮을수록, Nylon멘드릴의 경우 내경/외경 비가 높을수록 감도 증가를 위하여 효율적이다. 그리고 결정된 최적구조의 Al/foaming 및 Nylon/foaming멘드릴을 사용한 광섬유 하이드로폰의 감도는 각각 1rad./Pa 대비 약 82dB 및 85.7dB 정도 이었고, Al층상 복합체 보다는 Nylon층상 복합체를 이용하는 것이 고 감도의 광섬유 하이드로폰을 제조하는데 유리함을 알 수 있었다.

  • PDF

Application and Development of Dehumidication Systems - Focusing on Membrane Dryer (제습시스템의 응용과 발전 - Membrane Dryer를 중심으로)

  • 남상용;임지원;황해영;하성용
    • Membrane Journal
    • /
    • v.14 no.1
    • /
    • pp.1-17
    • /
    • 2004
  • Dehumidification systems have been developed for the various applications, especially for the production of dry compressed air. Compressed air producing system attach $\varepsilon$ d with dehumidification unit have advantages such as high reliability, low error ratio, comfortable working conditions, etc. Conventional dehumidification systems have several economical drawbacks like high electric cost, high cost of adsorbent and it is not environmentally friendly system because freezing agent like a Freon has been used. Membrane dryer is emerging system which have economical advantages and environmental merits.

Membrane Contactors for Water Carbonation

  • Alessandra Criscuoli;Enrico Drioli
    • Korean Membrane Journal
    • /
    • v.1 no.1
    • /
    • pp.59-64
    • /
    • 1999
  • A theoretical and experimental study made in order to determine the performance of mem-brane contactors in water carbonation is presented. In particular on the basis of experimental results pre-viously obtained it has been derived an expression in which the effect of some parameters as temprera-ture water and {{{{{CO }_{2 } }}}}} flow rate {{{{{CO }_{2 } }}}}} pressure trans-membrane pressure on the performance of the process is taken into account. The study refers to hollow fiber membrane contactors used for the experimental tests. The main scope has been to verify if by membrane contactors it is possible to reach the same de-gree of water carbonation as by trditional methods (1-5 g/1) and to derive for the module used a cor-relation able to describe the performance of the process at several operating conditions. The high {{{{{CO }_{2 } } }}}} removal observed confirms the interesting potentialties of membrane contactors also in gas streams purification.

  • PDF