• Title/Summary/Keyword: Hollow Fiber

Search Result 631, Processing Time 0.025 seconds

The Fundamental Studies and Development of Modified Electrothermal Vaporization Hollow Cathode Glow Discharge Cell (개선된 전열증기화 속빈음극관 글로우 방전셀의 기초연구 및 개발)

  • Lee, Seong-Hun;Cho, Won-Bo;Jeong, Jong-Pil;Choi, Woo-Chang;Kim, Kyu-Whan;Woo, Jeong-Su;Lee, Chang-Su;Kang, Dong-Hyun;Lee, Sang-Chun
    • Analytical Science and Technology
    • /
    • v.15 no.6
    • /
    • pp.514-520
    • /
    • 2002
  • The electrothermal vaporization (ETV) hollow cathode glow discharge atomic emission spectrometer for analysis of liquid sample has been developed and characterized. This system has improved the sample introduction method of electrothermal vaporization and the hollow cathode glow discharge. The sample introduction method was possible to provide high analyte transport efficiency to the plasma by helix coil made of tungsten material. In addition, small volume samples (<$30{\mu}{\ell}$) could be used. The system has glow discharge cell with special design for improvement of precision. The effect of discharge parameters such as discharge power, gas flow rate has been studied to find optimum condition. The emitted light was effectively carried into detector by fiber optic cable in UV region. The calibration curve of Pb, Cd were obtained with 3 samples.

Analysis of Folded Plate Structures Composed of [$45^{\circ}$/$-45^{\circ}$/$-45^{\circ}$/$90^{\circ}$/$45^{\circ}$/$45^{\circ}$/$-45^{\circ}$]r Type Laminated Composites Plates ($45^{\circ}$/$-45^{\circ}$/$-45^{\circ}$/$90^{\circ}$/$45^{\circ}$/$45^{\circ}$/$-45^{\circ}$r 복합재료 적층판으로 구성된 사각단면 절판구조물의 구조해석)

  • 김덕현;이정호;홍창우;이남주
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2000.04a
    • /
    • pp.93-96
    • /
    • 2000
  • The theory of non-prismatic folded plate structures was reported by the senior author in 1965 and 1966. Fiber reinforced composite materials are strong in tension. The structural element for such tension force is very thin and weak against bending because of small bending stiffnesses. Naturally, the box type section is considered as the optimum structural configuration because of its high bending stiffnesses. Such structures can be effectively analyzed by the folded plate theory with relative ease. The "hollow" bending member with uniform cross-section can be treated as prismatic folded plates which is a special case of the non-prismatic folded plates. Tn this paper, the result of analysis of a folded plates with one box type uniform cross-section is presented. Each plate is made of composite laminates with fiber orientation of [ABBCAAB]$_r$, with A=-B=$45^{\circ}$, and C=$90^{\circ}$. The influence of the span to depth ratio is also studied. When this ratio is 5, the difference between the results of folded plate theory and beam theory is 1.66%. is 1.66%.

  • PDF

Enzyme Deactivation During Enzyme Recycling with Ultrafiltration Hollow Fibers (한외여과막을 이용한 효소재순환 시스템에서의 효소역가감소)

  • 김준석;정용섭홍석인
    • KSBB Journal
    • /
    • v.11 no.3
    • /
    • pp.347-352
    • /
    • 1996
  • The enzyme deactivation in a membrane recycling system for the simultaneous saccharification and fermentation(SSF) was studied under various temperature and pressure. The optimum molecular weight cut off(MWCO) of the ultrafiltration membrane for recycling cellulase and ${\beta}$-glucosidase was 50,000. When the cellulase was recycled continuously through the membrane system, it was not deactivated. But the activity of ${\beta}$-glucosidase was decreased with an increase in operating temperature and transmembrane pressure. After 720 minutes at $42^{\circ}C$ and 24.8 psig , the activity of ${\beta}$-glucosidase was reduced by 35% of the initial activity. Such tendencies could be well explained by the results of highly induced shear at the fiber surface of membrane when temperature and transmembrane pressure became higher.

  • PDF

Effects of fiber forms on thermal anisotropy in fibrous composites (섬유강화 복합재의 열이방성에 대한 섬유 형태적 영향)

  • Sim, Hwan-Bo;Lee, Bo-Seong
    • Korean Journal of Materials Research
    • /
    • v.5 no.2
    • /
    • pp.215-222
    • /
    • 1995
  • Anisotropic pitch-based C-type and hollow carbon fibers can obtain wider shear stresses during the spinning and induce higher molecular orientation than that of round along the fiber axis. These fibers reinforced unidirectional epoxy composites were prepared by hot-press moulding method and perpendicular and parallel thermal conductivities of the composites were measured by a steady-state meth od. In the case of round carbon fibers reinforced epoxy composites(H-CF/EP), thermal anisotropic factor showed nearly 50, while those of H-CF/EP and C-CF/EP showed about 130 and 118, respectively. As a result, both H-CF/EP and C-CF/EP had an excellent directional thermal conductivity to distribute heat, above 200 %.

  • PDF

Effects of deficiency location on CFRP strengthening of steel CHS short columns

  • Shahabi, Razieh;Narmashiri, Kambiz
    • Steel and Composite Structures
    • /
    • v.28 no.3
    • /
    • pp.267-278
    • /
    • 2018
  • Structures may need retrofitting as a result of design and calculation errors, lack of proper implementation, post-construction change in use, damages due to accidental loads, corrosion and changes introduced in new editions of construction codes. Retrofitting helps to compensate weakness and increase the service life. Fiber Reinforced Polymer (FRP) is a modern material for retrofitting steel elements. This study aims to investigate the effect of deficiency location on the axial behavior of compressive elements of Circular Hollow Section (CHS) steel short columns. The deficiencies located vertically or horizontally at the middle or bottom of the element. A total of 43 control column and those with deficiencies were investigated in the ABAQUS software. Only 9 of them tested in the laboratory. The results indicated that the deficiencies had a significant effect on the increase in axial deformation, rupture in deficiency zone (local buckling), and decrease in ductility and bearing capacity. The damages of steel columns were responsible for resistance and stiffness drop at deficiency zone. Horizontal deficiency at the middle and vertical deficiency at the bottom of the steel columns were found to be the most critical. Using Carbon Fiber Reinforced Polymer (CFRP) as the most effective material in retrofitting the damaged columns, significantly helped the increase in resistance and rupture control around the deficiency zone.

Characteristics of Kapok Fibers According to Various Pretreatment Conditions (전처리 처리 조건에 따른 케이폭 섬유의 특성)

  • Hong, Seok Il;Lee, Hee Dong;Shim, Jae Yun;Seo, Won Jin;Lee, Beom Soo
    • Textile Coloration and Finishing
    • /
    • v.26 no.3
    • /
    • pp.230-236
    • /
    • 2014
  • The kapok fibers which are the functional fiber materials having natural hollows are environment friendly materials the demand and interest of which are increasing. The kapok fibers are environment friendly and natural hollow fibers which are 5-8 times lighter than cottons and have excellent performances in thermo keeping property, air permeability, bulkiness and resilience. In this study, the pretreatment according to the dyeing behaviors of kapok fibers were studied. Pretreatment(scouring, bleaching) were a variety of conditions. Scouring and bleaching, images of changed surfaces and cross-sections and dyeing behaviors of the dye-o-meter according to the concentration measured in meters and compared. Although the final exhaustion ratio of the kapok fibers scoured with a high concentration recipe was almost as same as that of the kapok fibers bleached with a high concentration recipe, the initial absorption speed of the kapok fibers scoured with the high concentration recipe was faster than that of the kapok fibers bleached with the high concentration recipe.

Polarization-Dependent Property of Long-Period Liquid Crystal Fiber Gratings (액정 장주기 격자의 편광 특성)

  • Baek, Seung-In;Jeong, Yoon-Chan;Kang, Jin-Gu;Lee, Byoung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2002.11a
    • /
    • pp.46-47
    • /
    • 2002
  • 최근 액정을 주입한 속이 빈 광섬유(Hollow fiber)와 주기적인 전극을 이용하여 전기적으로 제어 가능한 장주기 격자에 대해서 보고된 바 있다. 액정의 중요한 특성 중의 하나는 그 광축이 외부의 전기장에 의해 동적으로 재배열된다는 점이다. 또한 액정은 광축에 따라 굴절률이 다른 비등방성 물질이기 때문에 광축의 배열에 따라, 그리고 입사하는 빛의 편광에 따라 그 빛이 느끼는 굴절률이 달라지게 된다. 본 논문에서는 입사하는 빛의 편광에 따른 액정 장주기 광섬유 격자의 특성에 대해 연구하였다. 주기적인 전극의 길이는 3 cm이고 주기는 500 ${\mu}m$ 이다. 액정을 주입한 속이 빈 광섬유의 길이는 15 mm 이다. 입사하는 빛이 이상(extraordinary) 편광 상태일 때 약 6 dB 의 투과 손실을 나타냈으며 그 대역폭은 약 15 nm 이었다. 이 때 외부에서 인가한 전압은 150 V 였다. 입사하는 빛이 정상(ordinary) 편광 상태일 때에는 액정의 유효 굴절률이 외부 전기장에 대해 변하지 않기 때문에 장주기 투과 특성을 얻을 수 없었다.

  • PDF

Flexural and compression behavior for steel structures strengthened with Carbon Fiber Reinforced Polymers (CFRPs) sheet

  • Park, Jai-woo;Yoo, Jung-han
    • Steel and Composite Structures
    • /
    • v.19 no.2
    • /
    • pp.441-465
    • /
    • 2015
  • This paper presents the experimental results of flexural and compression steel members strengthened with carbon fiber reinforced polymers (CFRP) sheets. In the flexural test, the five specimens were fabricated and the test parameters were the number of CFRP ply and the ratio of partial-length bonded CFRP sheets of specimen. The CFRP sheet strengthened steel beam had failure mode: CFRP sheet rupture at the mid span of steel beams. A maximum increase of 11.3% was achieved depending on the number of CFRP sheet ply and the length of CFRP sheet. In the compression test, the nine specimens were fabricated and the main parameters were: width-thickness ratio (b/t), the number of CFRP ply, and the length of the specimen. From the tests, for short columns it was observed that two sides would typically buckle outward and the other two sides would buckle inward. Also, for long columns, overall buckling was observed. A maximum increase of 57% was achieved in axial-load capacity when 3 layers of CFRP were used to wrap HSS columns of b/t = 60 transversely.

Bioblock technique to treat severe internal resorption with subsequent periapical pathology: a case report

  • Mark Frater;Tekla Sary;Sufyan Garoushi
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.4
    • /
    • pp.43.1-43.9
    • /
    • 2020
  • A variety of therapeutic modalities can be used for the endodontic treatment of a traumatized tooth with internal root resorption (IRR). The authors present a case report of the successful restoration of a traumatized upper central incisor that was weakened due to severe IRR and subsequent periapical lesion formation. A 20-year-old female patient was referred to our clinic with severe internal resorption and subsequent periapical pathosis destroying the buccal bone wall. Root canal treatment had been initiated previously at another dental practice, but at that time, the patient's condition could not be managed even with several treatments. After cone-beam computed tomography imaging and proper chemomechanical cleaning, the tooth was managed with a mineral trioxide aggregate plug followed by root canal filling using short fiber-reinforced composite, known as the Bioblock technique. This report is the first documentation of the use of the Bioblock technique in the restoration of a traumatized tooth. The Bioblock technique appears to be ideal for restoring wide irregular root canals, as in cases of severe internal resorption, because it can uniquely fill out the hollow irregularities of the canal. However, further long-term clinical investigations are required to provide additional information about this new technique.

Experimental and analytical study on improvement of flexural strength of polymer concrete filled GFRP box hybrid members

  • Ali Saribiyik;Ozlem Ozturk;Ferhat Aydin;Yasin Onuralp Ozkilic;Emrah Madenci
    • Steel and Composite Structures
    • /
    • v.50 no.4
    • /
    • pp.475-487
    • /
    • 2024
  • The usage of fiber-reinforced polymer materials increases in the construction sector due to their advantages in terms of high mechanical strength, lightness, corrosion resistance, low density and high strength/density ratio, low maintenance and painting needs, and high workability. In this study, it is aimed to improve mechanical properties of GFRP box profiles, produced by pultrusion method, by filling the polymer concrete into them. Within the scope of study, hybrid use of polymer concrete produced with GFRP box profiles was investigated. Hybrid pressure and bending specimens were produced by filling polymer concrete (polyester resin manufactured with natural sand and stone chips) into GFRP box profiles having different cross-sections and dimensions. Behavior of the produced hybrid members was investigated under bending and compression tests. Hollow GFRPxx profiles, polymer-filled hybrid members, and nominative polymeric concrete specimens were tested as well. The behavior of the specimens under pressure and bending tests, and their load bearing capacities, deformations and changes in toughness were observed. According to the test results; It was deduced that hybrid design has many advantages over its component materials as well as superior physical and mechanical properties.