• Title/Summary/Keyword: Ho-patch

Search Result 388, Processing Time 0.029 seconds

Design of Dual-Band Chip Antenna using LTCC Multilayer Technology (LTCC 적층 기술을 이용한 이중대역 칩 안테나의 설계)

  • Kim Young Do;Won Chung Ho;Lee Hong Min
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.3 s.333
    • /
    • pp.19-24
    • /
    • 2005
  • This paper presents design simulation, implementation, and measurement of a miniaturized GPS/K-PCS dual-band LTCC chip antenna for mobile communication handsets. The dimension of LTCC chip antenna is $9mm\times15mm\times1.2mm$. The meander type radiating patch for dual-band operation is realized by using via holes with 0.3mm height to connect upper and lower-layer antenna. The lower meander type antenna is to be tuned to the lower frequency (GPS) band. The upper meander antenna with via hole connection is to contribute the higher frequency (K-PCS) band. The resonant frequency and frequency ratio of the proposed antenna can be adjusted by changing the height of via-hole and effective path of meander radiating patch. The electrical characteristics of the meander chip antenna applied to a GPS/K-PCS are suitable for mobile communication application.

A Study on Design of Microstrip Patch Antenna for Mobile Communication Systems using IE3D (IE3D를 이용한 단일 급전 이동통신용 마이크로스트립 패치 안테나 설계에 관한 연구)

  • Park, Jong-Dae;Park, Byeong-Ho;Shim, Woo-Seop;Kim, Myeong-Dong;Seong, Hyeon-Kyeong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.10a
    • /
    • pp.316-319
    • /
    • 2012
  • In this paper, a novel particle swarm optimization method based on IE3D is used to design a mobile communication Microstrip Patch Antenna. The aim of the thesis is to Design and fabricate an inset fed rectangular Microstrip Antenna and study the effect of antenna dimensions Length (L), Width (W) and substrate parameters relative Dielectric constant (${\varepsilon}r$), substrate thickness on Radiation parameters of Band width. When the antenna was designed, a dual-band, dual-polarized antenna was used to secure the bandwidth and improve performance, and a coaxial probe feeding method so that the phased array of antenna is easy.

  • PDF

Implementation of the Vehicle Antenna for the AM/FM/TDMB/GPS Receiver (AM/FM/TDMB/GPS 수신용 전장 안테나 제작)

  • Kim, Joo-Man;Son, Tae-Ho
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.8 no.5
    • /
    • pp.105-113
    • /
    • 2009
  • In this paper, a vehicle antenna for AM, FM, TDMB, GPS systems was designed and implemented. AM antenna loaded into small space of shark shape was designed by ferrite turn style antenna. For the FM and TDMB antenna, folded monopole antenna which helical is folded was applied. GPS antenna for achieving characteristics both bandwidth and gain improvement was designed microstrip patch that has air substrate and fractal structure. Receiving signal strengths by the measurement were presented for the AM, FM and TDMB antenna. AM signal strength was -65.7dBm, this strength is almost as same conventional pole antenna as -63.4dBm. It can be replaced conventional pole or glass antenna by the studied antenna. Signal strengths for FM and TDMB were -55.66 and -43.50dBm at center frequency, they are 5~10dB higher than conventional antenna. Measurements of bandwidth and gain for the GPS antenna showed 135 MHz under VSWR 2 : 1 and 4.31dBi, gains over GPS band were 3~5dB higher than ceramic patch antenna.

  • PDF

Feasibility Study of Improved Patch Group Prior Based Denoising (PGPD) Technique with Medical Ultrasound Imaging System

  • Kim, Seung Hun;Seo, Kanghyen;Kang, Seong Hyeon;Kim, Jong Hun;Choi, Won Ho;Lee, Youngjin
    • Journal of Magnetics
    • /
    • v.22 no.1
    • /
    • pp.55-59
    • /
    • 2017
  • The purpose of this study was to quantitatively evaluate image quality using intensity profile, coefficient of variation (COV), and peak signal to noise ratio (PSNR) with respect to noise reduction techniques in the ultrasound images. For that purpose, we compared with the median filter, Rudin-Osher-Fatemi (ROF), Anscombe and proposed patch group prior based denoising (PGPD) techniques. To evaluate image quality, the Shepp-Logan phantom and the ultrasound image were acquired using simulation and experiment, respectively. According to the results, the difference of intensity profile using PGPD technique is lowest compared with original Shepp-Logan phantom. In simulation, the measured COV was 0.249, 0.198, 0.198, 0.177, and 0.080 using noisy, median, ROF, Anscombe and PGPD technique, respectively. Also, in experimental image, the measured COV was 0.245, 0.230, 0.231, 0.242 and 0.187 using noisy, median, ROF, Anscombe and PGPD technique, respectively. Especially, when we used PGPD technique, the PSNR has highest value in both simulation and experiment. In this study, we performed simulation and experiment study to compare various denoising techniques in the ultrasound image. We can expect the PGPD technique to improve in medical diagnosis with excellent noise reduction.

Design and Simulation of an On-body Microstrip Patch Antenna for Lower Leg Osteoporosis Monitoring (하지 골다공증 감시를 위한 온-바디 마이크로 스트립 패치 안테나의 설계 및 모의실험)

  • Kim, Byung-Mun;Yun, Lee-Ho;Lee, Sang-Min;Park, Young-Ja;Hong, Jae-Pyo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.4
    • /
    • pp.763-770
    • /
    • 2021
  • In this paper, in order to exclude the influence of BAN(Body Area Network) signals operating in the ISM band, the design and optimization process of an on-body microstrip patch antenna operating at 4.567 GHz is presented. The antenna for the monitoring of the lower legs with cancellous osteoporosis is designed to be lightweight and compact with improved return loss and bandwidth. The structure around the applied lower leg consisted of a five-layer dielectric plane. Taking into account losses, the complex dielectric constant of each layer is calculated using multi Cole-Cole model parameters, whereas a unipolar model is used for normal or osteoporotic cancellous bones. The return loss of the coaxial feed antenna on the phantom is -67.26 dB at 4.567 GHz, and in the case of osteoporosis, at the same frequency the return loss difference is 35.88 dB, and the resonance frequency difference is about 7 MHz.

A Case Report of Stroke Patient With Drooling Improved by Electro-acupuncture Therapy (뇌 손상 환자의 침 흘림에 대한 전침 적용 1례)

  • Ahn, Lib;Kim, Su-min;Kim, Myung-ho;Lee, Sang-ah;Choi, Dong-jun
    • The Journal of the Society of Stroke on Korean Medicine
    • /
    • v.15 no.1
    • /
    • pp.90-96
    • /
    • 2014
  • Drooling causes inconvenience and develops complications, therefore it can be very stressful to patients and caregivers. Drooling caused by neurological disabilities appears to be the consequence of dysfunction in the coordination of the swallowing mechanism. However, there is no explanation about drooling by brain injury in oriental medicine literature. This is the case report about a stroke patient with drooling improved by electro-acupuncture therapy. The patient already applied scopolamine patch, and improved drooling before admission. However, caregiver concerned about side effects, so we stopped using scopolamine patch and applied electro-acupuncture for drooling treatment. The patient was treated by 4 acupuncture points on either side of Yeomcheon(CV 23), and Jichang(ST 4), Hyeopgeo(ST 6) with mixed low frequency electro stimulation. Although we stopped using scopolamine patch, drooling maintained improved state without a change, futhermore after 16 days later, drooling had disappeared until the patient discharged. This result showed electro-acupuncture is useful method to improve drooling caused by brain injury.

  • PDF

The Effectiveness of Buprenorphine Transdermal Patch on Patients with Shoulder Pain: Short-Term Follow-up Study (견관절 통증을 동반한 동결견 환자에게서 Buprenorphine transdermal patch의 효과: 단기 추시 결과)

  • Hong, Jin Ho;Park, Yong Bok;Ryu, Ho Young;Jeon, Sang Jun;Park, Won Ha;Yoo, Jae Chul
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.7 no.1
    • /
    • pp.7-12
    • /
    • 2014
  • Purpose:The effectiveness of transdermal buprenorphine patch on the patients with frozen state of frozen shoulder was evaluated. Materials and Methods: Between March and September in 2013, 127 patients with pain and limited range of motion in shoulder joint over 6 months were included. Every patient was confirmed the diagnosis through MRI or ultrasonogram and each patient received intra-articular injection of steroid once. After 2~4 weeks, every patient was interviewed via telephone survey and finally 105 patients were included, 54 patients received only oral NSAIDs (NP group) while 51 patients received additional transdermal buprenorphine patch (BP group). Pain and functional visual analog scale (PVAS, FVAS), American Shoulder Elbow Society (ASES) score was checked. Results: Generally, every outcome variables showed improvements in both groups (p<0.001). PVAS score after treatment showed superior result in NP group but it was not significant (p=0.088). In ASES score, NP group had superior result than BP group and it had significant difference. Similarly in FVAS, NP group showed superior result but the data before treatment was significantly different (p=0.028) Conclusion: Transdermal buprenorphine patch didn't show superior treatment result in the patient with frozen state of frozen shoulder which was applied with oral NSAIDs after single intra-articular glenohumeral steroid injection in short-term follow-up.

  • PDF

Development of application that removes moving objects from pictures (사진에서 움직이는 물체를 제거하는 어플리케이션 개발)

  • Byun, Ju-Seung;Kim, Min-ho;Shin, Byeong-Seok
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2017.04a
    • /
    • pp.993-994
    • /
    • 2017
  • 여러 장의 사진을 촬영하여 움직이는 객체를 식별하고 이를 지울수 있는 모바일 어플리케이션을 제안한다. 여러 장의 사진을 촬영 후 첫 번째 사진을 기준으로 나머지 사진들에 와핑(warping) 변환을 적용하고, 최적의 패치(patch)들을 변환된 사진 속에서 골라내어 이동 객체로 가려진 배경을 복원한다.

Transdermal Drug Delivery Devices Based on Microneedles: A Review

  • Kim, Byeong Hee;Seo, Young Ho
    • Journal of mucopolysaccharidosis and rare diseases
    • /
    • v.1 no.1
    • /
    • pp.5-14
    • /
    • 2015
  • This paper addresses the state of arts of microneedles for the transdermal drug delivery applications. Microneedles can be classified based on materials and shapes. For the materials, microneedles could be made of ceramics, metals and polymers. The shape of the microneedles can be classified into solid and hollow microneedles. Methods of transdermal drug delivery based on microneedle patch are discussed, and various fabrication methods of microneedle patches are introduced.

Design at Small Triangular Slottes Patch Antenna (슬롯에 의한 소형 삼각형 패치 안테나 설계)

  • Hyun, Jae-Sung;Son, Tae-Ho
    • Proceedings of the KAIS Fall Conference
    • /
    • 2006.05a
    • /
    • pp.377-380
    • /
    • 2006
  • 본 논문에서는 USPCS 기지국 송신밴드 (주파수 대역 $1.93\;Ghz^{\sim}1.99\;Ghz$)에 만족하는 소형이면서도 대역폭이 넓은 슬롯 삼각형 패치 안테나를 설계 및 제작하였다. 각각의 슬롯의 길이와 폭을 변화시켰을 때의 입력반사계수의 특성을 고찰하였고, 슬롯이 있을 때와 없을 때의 패치 안테나의 크기를 비교하였다. 그 결과 슬롯에 의해 크기를 줄일 수 있을 뿐만 아니라 대역폭도 넓힐 수 있음을 확인하였다.

  • PDF