Hip Arthrodesis to Treat Severe Hip Osteoarthritis in an Adolescent with Down Syndrome (다운증후군 청소년의 중증 고관절 골관절염에서 고관절 유합술)

  • Jung, Yu-Hun;Shin, Keun-Young;Lee, Joo-Young
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.2
    • /
    • pp.164-167
    • /
    • 2021
  • Down syndrome is the most common chromosomal disorder and is accompanied by hip osteoarthritis in approximately 28% of patients. This paper reports a case of hip arthrodesis as a treatment for severe hip osteoarthritis in adolescent Down syndrome patients. When performing surgical treatment of patients with Down syndrome, it is necessary to take a comprehensive approach that considers not only the medical point of view, but also the psychological and economic requirements of the patient and their social environment.

The Wear Rate and Survivorship in Total Hip Arthroplasty Using a Third-generation Ceramic Head on a Conventional Polyethylene Liner: A Minimum of 15-year Follow-up

  • Bum-Jin Shim;Sung-Jin Park;Chan Ho Park
    • Hip & pelvis
    • /
    • v.34 no.2
    • /
    • pp.115-121
    • /
    • 2022
  • Purpose: The purpose of this study was to evaluate the wear and survival rates of third-generation ceramic heads on a conventional ultra-high molecular weight polyethylene liner. Materials and Methods: A total of 160 hips (147 patients with a mean age of 55.9 years) who underwent total hip arthroplasty using the third-generation ceramic head on a conventional polyethylene liner from March 1998 to August 2003 were reviewed retrospectively. Evaluation of the wear rate for 56 hips (49 patients) followed-up for at least 15 years was performed using the PolyWare program version 8 (Draftware Developers, USA). The Kaplan-Meier survivorship was also evaluated. Results: Linear wear and volumetric wear rates were 0.11±0.47 mm/year and 32.75±24.50 mm3/year, respectively. Nine revisions were performed during the follow-up period because of cup or stem loosening. The Kaplan-Meier survival rate, using cup revision or total revision total hip arthroplasty (THA) as the endpoint of analysis, was 93.7% at 15 years and 73.6% at 20 years. Conclusion: Because all revisions were performed between 15 and 20 years in our study, surgeons should pay greater attention to patients who underwent THA with ceramic-on-polyethylene bearing from 15 years postoperatively. Contemporary alumina ceramic on highly cross-linked polyethylene could certainly be a good alternative bearing couple providing better longevity.

Dental Prosthesis Causing Pneumonia in a Delirious Elderly Patient after Hip Fracture Surgery (고관절 골절 수술후 발생한 섬망환자의 치과보철물에 의한 폐렴)

  • Lee, Young-Kyun;Ha, Yong-Chan;Koo, Kyung-Hoi
    • Journal of Trauma and Injury
    • /
    • v.25 no.3
    • /
    • pp.97-100
    • /
    • 2012
  • We report a case of delayed diagnosed pneumonia due to an aspirated metallic crown, which had been detached from a molar tooth. Dental prosthesis should be checked and a careful review of the chest radiograph is mandatory when an elderly patient with delirium after hip fracture surgery develops pneumonia postoperatively.

Hip Flexion during Intraoperative Insetting of a Perforator Flap for Reconstruction of an Ischial Sore

  • Nam, Su Bong;Oh, Heung Chan;Lee, Jae Woo;Song, Kyeong Ho;Bae, Seong Hwan
    • Archives of Reconstructive Microsurgery
    • /
    • v.25 no.2
    • /
    • pp.43-48
    • /
    • 2016
  • Purpose: Perforator flap-using ischial sore reconstruction is performed in a prone position. But after the surgery, recurrence frequently occurs in a sitting position. In this sense, we introduce modified flap insetting method which closely resembles patient's sitting position to lessen the flap tension surgically. Materials and Methods: Authors tried to check a skin tension difference between prone position and sitting position in normal people group and to find out the importance of performing flap insetting in hip flexion position. Healthy volunteers were collected (n=20) and designed the same length of 4 divided sections around the ischium. Lengths of each section were measured when hip joint was flexed to 90 degree and when both hip and knee joints were flexed to 90 degree and the statistical evaluation was performed. Twenty cases with ischial sore underwent reconstructive surgery using perforator flap under hip flexion position and followed-up for any recurrences. Results: There was a meaningful difference between the joint flexed skin length and that of the neutral position. Flap showed sufficient thickness over 12 months. Conclusion: It seems that recurrence could be reduced when the reconstructed flap could sufficiently cover in a sitting position regarding its significant length difference in normal people group.

Highly Cited Articles in Periacetabular Osteotomy Research

  • Colin K. Cantrell;Cody J. Goedderz;Ryan S. Selley;Ernest L. Sink;Michael D. Stover
    • Hip & pelvis
    • /
    • v.34 no.2
    • /
    • pp.87-95
    • /
    • 2022
  • Purpose: The aim of this study is to identify highly cited articles and examine trends and characteristics in research on periacetabular osteotomy. Materials and Methods: The 50 most highly cited articles on periacetabular osteotomy research were identified using Scopus. Data regarding article demographics and publication were collected from each article and an analysis was performed. Results: The mean citation count was 125±37. The article with the highest total citation count (796), five-year citation count (327), and five-year citation density (65/year) was reported by Reinhold Ganz. The five-year citation density showed strong correlation with total citation density (r=0.930, P<0.001). Reinhold Ganz, the most productive author, was listed on 13 articles in the cohort with 455 weighted citation points. Conclusion: This study provides a collection of articles examining periacetabular osteotomies and demonstrates that citation count can be regarded as an acceptable measure of the contemporary academic influence of an article.

Total Hip Arthroplasty with Cemented Dual Mobility Cup into a Fully Porous Multihole Cup with Variable Angle Locking Screws for Acetabular Fractures in the Frail Elderly

  • Mathias van den Broek;Kris Govaers
    • Hip & pelvis
    • /
    • v.35 no.1
    • /
    • pp.54-61
    • /
    • 2023
  • Purpose: The purpose was to examine the clinical and radiological outcomes after surgical treatment of acetabular fractures with total hip arthroplasty with a dual mobility cup cemented into a porous multihole cup in the population of frail elderly patients. Materials and Methods: A retrospective review of 16 patients who underwent surgery (mean age, 76.7 years) with a mean follow-up period of 36.9 months was conducted. Following surgery, patients underwent postoperative follow-up at six weeks, three, six, and 12 months and clinical and radiological examinations were performed. Results: Classification of fractures was based on the Letournel classification. Following surgery, all patients were allowed weight-bearing as tolerated immediately postoperative. Fourteen patients showed maintenance of preoperative mobility status at one year. The mean Harris hip score was 64.8 (range, 34.7-82.8) and 80.0 (range, 60.8-93.8) at three months and one year, respectively. The mortality rate was 12.5% at one year (2/16). Complications included heterotopic ossification (2/16), deep venous thrombosis (1/16), heamatoma (1/16), and femoral revision due to a Vancouver B2 fracture (1/16). No case of deep infection, dislocation, or implant loosening was reported. Conclusion: Total hip arthroplasty using a dual mobility cup cemented into a porous multihole cup with locking screws resulted in a stable construct with a capacity for immediate weight-bearing as tolerated with rapid relief of pain. The findings of this study suggest that this procedure can be regarded as a safe method that has shown promising clinical and radiological outcomes for treatment of patients with medical frailty.

The Effects of COVID-19 Pandemic on the Recovery of Hip Fracture Patients

  • Young Yool Chung;Sung Nyun Baek;Tae Gyu Park;Min Young Kim
    • Hip & pelvis
    • /
    • v.35 no.4
    • /
    • pp.253-258
    • /
    • 2023
  • Purpose: To figure out how complete control of family visits to prevent infection of coronavirus disease 2019 (COVID-19) affected the activity recovery of hip fracture patients admitted to nursing hospitals. Materials and Methods: Eighty-one patients with hip surgery in the two years prior to COVID-19 pandemic were classified as Group A, and 103 patients in the next two years were designated as Group B. The subjects' walking ability was evaluated by using the modified Koval index (MKI). In order to analyze the impact of the family visit control to the subjects, each group was classified into two different groups: (1) inpatients group who admitted to nursing hospitals and (2) home-treated patients. Additionally, statistical elements were processed in consideration of other factors that may affect the results of the experiment. Results: The MKI evaluated at 6 months postoperative was 3.31±1.79 in Group A and 2.77±1.91 in Group B, and it was meaningfully low after the pandemic (P=0.04). There was significantly low among both of Group A 2.74±1.76 and Group B 1.93±1.81 after the pandemic (P=0.03) among those treated at the nursing hospital. The rate of deterioration of the MKI was 35 (43.2%) in Group A and 57 (55.3%) in Group B, which increased by 12.1% after the pandemic. Conclusion: The pandemic had a negative effect on the recovery of postoperative activities of elderly hip fracture patients who admitted to nursing hospitals when family access was completely restricted to prevent infection.

Ultrasonography-Guided Multiple Needling for the Treatment of Calcific Tendinitis Around Hip Joint: 4 Cases Report (초음파 감시하 다발성 천공술을 이용한 고관절 주위 석회화 건염의 치료: 4례 보고)

  • Kwon, Yong-Wook;Lee, Kyung-Jae;Min, Byung-Woo;Bae, Ki-Cheor;Cho, Chul-Hyun
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.5 no.2
    • /
    • pp.89-93
    • /
    • 2012
  • Although calcific tendinitis around hip joint is a rare condition, patients with symptomatic calcific tendinitis serve very severe pain and are disturbed their daily activities. We report four calcific tendinitis patients who had acute pain around the hip with limitation of motion of the joint and were treated with ultrasonography-guided multiple needling with dramatic pain relief.

  • PDF

Erythrocyte Sedimentation Rate and C-reactive Protein Values in Patients with Hip Arthroplasty (인공고관절 치환술 전후의 CRP 및 ESR의 변화)

  • Kim, Se-Dong;Lee, Dong-Chul;Park, Dong-Gu
    • Journal of Yeungnam Medical Science
    • /
    • v.9 no.2
    • /
    • pp.218-223
    • /
    • 1992
  • Serum C-reactive protein(CRP) levels and erythrocyte sedimentation rates(ESR) were measured in 46 patients treated with uncomplicated primary hip replacements, 39 total tip replacements and 7 bipolar hip replacements. In uncomplicated primary hip replacements, ESR levels were slightly elevated preoperatively and were variable postoperatively. But CRP was normal before surgery and elevated in postoperative course, but back to normal within three weeks in most cases. Early success of hip arthroplasty is indicated by normalization of CRP within three weeks, regardless of ESR. Since ESR seems to react somewhat differently from the CRP, both methods are useful in the monitoring of complications after hip arthroplasty.

  • PDF

Ultrasonographic Findings of Normal Hip Joint and Painful Hip due to Soft Tissue Problem (고관절 초음파의 정상 소견 및 고관절 주위 질환의 초음파 소견)

  • Nam, Woo-Dong;Nam, Shin Woo;Han, Kye Young
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.3 no.1
    • /
    • pp.38-46
    • /
    • 2010
  • The lesions around hip joint including bone, joint and soft tissue can cause the pain. For diagnosis of these lesions, physical examination and simple X-ray were accomplished primarily. Some special cases, CT or MRI was a useful tool. However ultrasonography could provide non-invasive and dynamic images for the lesions of tendon and bursa, and it could be a useful tool for follow up after hip surgery. Due to the deep location of hip joint, ultrasonography is not easy for physician to examine and its application was impossible in some obese patients. This article deals with the normal and pathologic ultrasonographic findings of the hip joint and various applications using ultrasonography.

  • PDF