A bus seat is required to be ergonomically designed in terms of its shape and physical properties to increase seating comfort. The present study is intended to develop a systematic bus seat evaluation protocol based on seating comfort. A total of 48 participants evaluated 12 parts (seat belt, recliner, armrest, headrest, upper-back support, lumbar support, seatback bolster, seatback overall, hip support, thigh support, seatpan bolster, and seatpan overall) of 12 bus seats with 17 subjective comfort measures (e.g., convenience of control, suitability of size, and overall comfort). Lastly, ergonomic features of shape and physical properties of each seat part were identified based on the subject evaluation analysis results. The developed bus seat evaluation protocol can be applied to evaluate various types of seats.
This paper treats the implementation of a statically stable control system for a biped walking robot with 10 degrees-of-freedom. Statically stable walking of a biped robot can be realized by keeping the center of mass (COM) inside the sole of the supporting foot (or feet) during single-support or double-support phases. We predetermined five static positions for walking based on the COM method. The positions can be represented by the length of the gait, the width between the feet, the height of the foot and two parameters in the hip movement. With the five parameters, we calculated the position trajectory. And we got the angular trajectories of 10 joints from the posit ion trajectory using the position tracking control and neural network. By tracking the angular trajectories, the robot can walk maintaining stability. We implemented walking of a biped robot throught the above ...
The purpose of this report was to describe the gait pattern and parameters of the complicated bilateral amputee with right transtibial and left tarsometatarsal amputation. Using a Vicon 370 three dimensional gait analysis system, the gait analysis was performed at pre and post-test. Treadmill Training with 15 degree, incline was practiced for 8weeks, 3times per week. In linear parameters, the Velocity, Stride length and Single limb support were increased than pre-test. but Cadence and Double limb support were less post-test than pre-test. In kinematics, the maximal pelvic tilt angle showed right side $21.87^{\circ}$, left side $20.67^{\circ}$ at pre-swing phase, and decreased as compared with pre-test. Especially, the inimal hip flexion angle showed right side $-6.83^{\circ}$, left side $1.52^{\circ}$ at pre-swing phase and increased as compared with pre-test. The maximal knee flexion angle disclosed right side $2.66^{\circ}$, left side $21.71^{\circ}$ at stance phase, and decreased as compared with pre-test. In kinetics, the hip extension moment on initial contact stage was right side 0.938NM/Kg, left side 0.09NM/Kg, which was impaired compared with normal person.
In this study the swimwear pattern focused on a typical middle-aged women's body was developed and discussed. To determine the characteristics of a typical middle-aged women's body, their actual bust were cast. According to a generated flattened body surface shell, the right side of pattern was designed considering stretching ratio of swimwear materials as shown in the figure 3. Special features of the developed swimwear pattern are a bust dart, a particularly designed lining, a power-net, and a brassiere-cup. Against a commercial swimwear pattern, the darts were applied to bust area considering its volume. The lining was attached on the entire right side except brassiere part, and power-net was added twice on belly and hip part. As a result, silhouette and body shape were improved. The new brassiere-cup was designed and made to satisfy the middle-aged women's demand about their bust volume. Swimwear fitting test was performed, and it was evaluated. The developed swimwear rated activity, body support, entire silhouette, pressure, comfortable fitting, suitability with body figure, nudity higher by comparison with a commercial swimwear, as shown in the Table 6. Specially the developed swimwear satisfied future customers about a bust, a hip, a waist, a belly area, which the middle-aged women are not confident. Reducing exposure of an armhole and upper leg area, it also satisfied them. New developed swimwear pattern will provide useful reference to swimwear businesses targeting middle-aged women.
Objective: The aim of this study was to investigate the influence of seat heights for optimizing the ingress/egress performance in the elderly people. Background: Recently elderly users have been increasing in number and the ease of ingress/egress of the vehicle becomes an important issue. Method: Seven elderly subjects participated in this study(age: 71.7${\pm}$3.6yr, height: 167.7${\pm}$5.4cm, weight: 68.1${\pm}$11.5kg). Each subject performed the sitting and rising task from comfortable seated position on the chair under the following conditions: (1) with a lumbar support and (2) without a lumbar support. We measured EMG activities of seven muscles(tibialis anterior, soleus, gastrocnemius, vastus lateralis, rectus femoris, biceps femoris and erector supinae) and ranges of motion in lower limb during sitting and standing from three different heights (400mm, 500mm and 600mm from ground) of slide-up seat. Results: Muscle activities and angular movements of hip and knee joints during standing-up and sitting-down with a high seat height(600mm) were reduced mean 30.4% in extensor muscles, 57.11% in flexor muscle, 18.74% in erector muscle and 31.0% in joints compared with a low seat height(400mm). Conclusion: Muscle activities and joint movements in hip and knee were reduced when rising/sitting from a high seat height(600mm) compared with a low seat height(400mm). Application: This study can be used to design vehicle that are easy to get in and out of by older peoples with or without impairments.
Purpose: The purpose of this study was to compare the spatiotemporal and kinematic gait parameters and muscle activity of the lower extremities between forward walking on sand (FWS) and backward walking on sand (BWS) in normal adults. Methods: This study was conducted on 13 healthy adults. Subjects performed FWS and BWS and the spatiotemporal and kinematic gait parameters of stride time, stride length, velocity, cadence, step length, stance, swing, double support, and hip range of motion (ROM), knee ROM were measured by a wearable inertial measurement unit system. In addition, the muscle activity of the rectus femoris (RF), biceps femoris (BF), tibialis anterior (TA), and gastrocnemius (GA) was measured. Results: The stride length, stride velocity, cadence, and step length in the BWS were significantly lower than FWS (p<0.05), and stride time was significantly greater (p<0.05). However, there was no significant difference in the ratio of stance, swing, and double support between the two (p>0.05). The kinematic gait parameters, including hip and knee joint range of motion in BWS, were significantly lower than FWS (p<0.05). The muscle activity of the RF in BWS was significantly higher than FWS (p<0.05), but the muscle activity of the BF, TA, GA did not show any significant differences between the two movements (p>0.05). Conclusion: A strategy to increase stability by changing the gait parameters is used in BWS, and this study confirmed that BWS was a safe and effective movement to increase RF muscle activity without straining the joints. Therefore, BWS can be recommended for effective activation of the RF.
Study was developed the metallic plate for fixation in the femur fracture and plates has a firm place in fracture treatment. This plates can be stabilized for fracture fixation as well as biological and dynamical device. The device's designation and sizing has a optimization with bending structural stiffness and strength, known meaning that is reliable regardless of the plate by the short type and long type. The bending strength of the curved metallic long plate has to evaluate a 11,000N and the bending strength of the curved metallic short plate has to evaluate a 6,525N. This see the X-ray image of bending angle made certain of 15$^{\circ}$ at number 2 and same 82.87$^{\circ}$ at number 2, 4, 5, 7, 8, 9, 10 by outside angle, and confirmed 25.26$^{\circ}$ at number 3, 3.68$^{\circ}$ at number 6, 15.64$^{\circ}$ at number 9 by inside angle. This study shows that keep up the metallic plate for fixation in the femur fracture through X-ray Image and the device can be used to support Revision case of Hip Implant and to use a case of Hip screw compression of Hip Neck Fracture. Short plate have a wrapping of femur and long plate have to preserve a pole of femur.
The purpose of this study was to compare kinematic characteristics on the limbs at 3 different walking speed during the energy and the normal walking. Eight subjects performed energy walking and normal walking at the slow speed(65 beats/min), the normal speed(115beats/min), the fast speed(160 beats/min). The 3-d angle was calculated by vector projected with least squares solution with three-dimensional cinematography(Motion Analysis corporation). The range of motion was calculated on the trunk, shoulder, elbow, hip, knee joint. The results showed that stride length was no difference of the two walking pattern. The duration of support phase was also no difference of the two walking pattern. The range of motion of shoulder joint significantly increased in the sagittal and frontal planes, and the range of motion of elbow joint significantly increased as the energy walking. The range of motion of hip joint had no significant difference in the any planes in changing of walking speed. But the most remarkable difference of the two walking patterns revealed at the trunk. The range of flexion/extension angle had significant increasing $2.36^{\circ}$ at normal speed, and the range of the right/left flexion angle had significant increasing below $4^{\circ}$ at the 3 walking speed, and The range of rotation angle had significant increasing $7.35^{\circ}$, $9.22^{\circ}$, respectively at the normal and slow speed. But there was no significant difference of range of motion at the hip and knee joints between energy walking and normal walking.
Background and Purpose. Objective measurements of hamstring muscle length are needed to quantify baseline limitations and to document the effectiveness of therapeutic interventions. Several indirect clinical tests for measuring hamstring muscle length are available, but influence of their test procedure is not well documented. The purpose of this study were 1) to describe hamstring muscle length as reflected by use of six tests(active straight leg raising(ASLR), passive straight leg raising(PSLR), passive straight leg raising with the lower back flat(PSLRB), active knee extension(AKE), passive knee extension(PKE), hip joint angle(HJA). 2) to examine the correlation among the tests. Subjects, Sixty subjects(30 men. 30 women) ranging in age from 18 to 25 years(mean 20.2 years) and with no limitation hamstring flexibility and no neurological and orthopedical problems. Methods. All subjects performed six tests. A inclinometer was used to determine the end point of range of motion. HJA was measured using an inclinometer placed over the sacrum. PSLRB were tested PSLR with the low back flat and the opposite thigh slightly flexed and support on pillows. Results, A mean ASLR value of 85.9 degrees, PSLR value of 99.9 degrees, PSLRB value of 109.8 degrees, AKE value of 77.2 degrees PKE value of 83.1 degrees and HJA value of 73.0 degrees were obtained for all subjects. A dependent t-test showed significant difference between the angles of ASLR and PSLR(p<0.001). There was a significant difference between the angles of PSLR and PSLRB(p<0.001). There was a significant difference between the angles of AKE and PKE(p<0.001). The highest correlation was between PSLR and PSLRB(r=0.915, p<0.001). All SLR tests were significants related(p<0.001), as well as AKE and PKE(p<0.001). The lowest correlation was between PKE and HJA(r=0.171. p>0.05). Conclusion and Discussion. The results indicated that the hip flexion angles for ASLR, PSLR and PSLRB were a difference, and the knee extension angles for AKE and PKE were a difference.
Purpose: This study was done to establish reference data for temporo-spatial, kinematic and kinetic parameters for normal Koreans as they age. Methods: Normal adults and children without a previous history of musculoskeletal problems were enrolled in this study. The normal subjects were divided by age into three groups: Group I: children ($11.95{\pm}0.29$ years); Group II: young adults ($23.90{\pm}3.67$ years); Group III: older adults ($71.40{\pm}4.08$ years). The temporo-spatial and kinematic data were measured using 6 MX3 cameras while each subject walked through a 10 m walkway at a self-selected speed. The kinetic data were measured using 2 force plates and were calculated by inverse dynamics. Results: Motion patterns are typically associated with a specific phase of the gait cycle. Our results were as follows: 1. There were significant differences between the different age groups in temporo-spatial parameters such as cadence, double support, time of foot off, stride length, step length, and walking speed. 2. There were significant differences between the groups in kinematic parameters such as range of motion (ROM) of the hip, knee and ankle in the sagittal plane, ROM of the pelvis, hip and knee in the coronal plane and ROM of the pelvis, hip and ankle in the transverse plane. 3. There were significant differences between the groups in kinetic parameters such as joint moments of force, joint mechanical power generation or absorption and ground reaction forces. Conclusion: The results of this study can be utilized (a) as a reference for kinematic and kinetic data of gait analysis in normal Koreans, and (b) as an aide in evaluating and treating patients who have problems relating to gait.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.