• Title/Summary/Keyword: Hip joint fracture

Search Result 44, Processing Time 0.121 seconds

Influence of Impact Angle on Deformation in Proximal Femur during Slide Falling (측방 낙상시의 충격 각도가 대퇴골 근위부의 변형에 미치는 영향)

  • 김병수;배태수;김정규;최귀원
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.3
    • /
    • pp.233-239
    • /
    • 2003
  • Falling related injuries are categorized as the most serious and common medical problems experienced by the elderly, hip joint fracture, one of the most serious consequences of falling in the elderly, occurs in only about 1% of falling. Nevertheless, hip fracture accounts for a considerable part of the disability, death, and medical costs associated with falling. In this study, we considered the impact angle and displacement rate in falling as another factor affecting femoral strength. Using a fresh-frozen human femur, we developed system to simulate the falling condition and then conducted the experiments changing the impact angle (0$^{\circ}$, 15$^{\circ}$, 30$^{\circ}$) of proximal femur. Also, in order to analyze the relative risk due to falling to normal situation in proximal femur, we did the static test simulating the two-legged stance condition. The results showed that the change in impact angle affected the strain distribution in proximal femur, and that a large deformation in femoral neck than in other sites. Furthermore despite low impact velocity, a large deformation in proximal femur occurred in the impact test and different strain distribution was observed compare to the static case.

Ceramic-Ceramic Wear Zirconia/Alumina Composites For The Application Of Total Hip Joint Implant (인공 고관절 골두용 세라믹 복합재료에 대한 세라믹-세라믹 접촉 마멸 특성 분석)

  • Kim H.;Lee K.Y.;Kim D. J.;Lee M. H.;Seo W. S.
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.355-361
    • /
    • 2004
  • Ceramic femoral heads in the total hip replacement have been developed to reduce the polyethylene liner wear, Alumina and zirconia (3Y-TZP) having the excellent tribological properties are coupled against acetabular cups of polyethylene and are used in clinical application worldwide. However, alumina has a risk of catastrophic failure, and zirconia has the low temperature degradation in spite of enhanced fracture toughness. Recently, novel zirconia/alumina composite is very attractive due to the low temperature degradation (LTD)-free character and high fracture toughness. In the present study, we focus on the wear of ceramic on ceramic, which are able to be used as femoral heads and acetabular cups. Therefore, LTD-free zirconia/alumina composites with three compositions are made in a form of disk and cylinder, and the wear of the composites is performed on pin-on-disk type wear tester. The wear is conducted with or without lubricant. All the composites fabricated with the different composition show the good wear resistance.

  • PDF

내저온열화 특성을 갖는 지르코니아/알루미나 복합세라믹의 마멸평가

  • Kim H.;Lee KY;Kim DJ;Lee MH;Seo WS
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.91-94
    • /
    • 2003
  • Ceramic femoral heads in the total hip replacement have been developed to reduce the polyethylene liner wear. Alumina and zirconia (3Y-TZP) are using in clinical application worldwide and there are many good test reports. However, alumina has a risk of catastrophic failure, and zirconia has the low temperature degradation in spite of enhanced fracture toughness. Recently, novel zirconia/alumina composite having low temperature degradation-free character and high fracture tough . was developed and it leads the lower wear 3f polyethylene than alumina and zirconia. In the present study, in order to optimise the microstructure of low temperature degradation (LTD)-free zirconia/alumina composite for the best wear resistance of polyethylene, various compositions of (LTD)-free zirconia/alumina composites were fabricated, and the sliding wear of UHMWPE against these novel composites were examined and compared with that against alumina and zirconia ceramics used for total hip joint heads.

  • PDF

Early Stage Legg-Calve-Perthes Disease in a Dog: Clinical, Surgical, Radiological, Computed Tomography and Histological Findings (초기 허혈성 대퇴골두 괴사증을 보이는 개에서 임상학적, 수술적, 방사선학적, 컴퓨터단층촬영, 조직학적 소견)

  • Thak, Min-Ae;Yoon, Hun-Young;Jeong, Soon-Wuk
    • Journal of Veterinary Clinics
    • /
    • v.30 no.5
    • /
    • pp.366-370
    • /
    • 2013
  • A 7-month-old Pomeranian presented with non-weight bearing lameness on the right pelvic limb. Physical examination revealed pain on extension of the right hip joint, and serum chemistry results showed an increased concentration of creatine kinase. Radiographic findings at admission included a weak radiolucent line on the right femoral head and widening of the right hip joint space, and mild displacement of the right capital femoral epiphysis was additionally identified on day 14. Computed tomography (CT) showed a decreased Hounsfield Unit measurement and a fracture line on the right femoral head. Early stage Legg-Calve-Perthes disease (LCPD) was diagnosed and femoral head and neck ostectomy was performed on the right femur. A fracture fissure and osteophytes at the epiphyseal plate of the femoral head were identified surgically. Necrosis in the femoral metaphysis and epiphysis was observed histologically. This case report describes the radiography, CT images, and surgical and histological findings in a dog with early stage LCPD.

Treatment of Avascular Necrosis of the Talus with Vascularized Fibular Graft (혈관부착 비골이식술을 이용한 거골 무혈성 괴사의 치료)

  • Chung, Duke-Whan;Kho, Duk-Whan
    • Archives of Reconstructive Microsurgery
    • /
    • v.9 no.1
    • /
    • pp.49-55
    • /
    • 2000
  • Nonunion and avascular necrosis are well-recognized complications of severe ankle injury especially aftrer talar neck fracture. The treatment of avascular necrosis is controversial and methods of treatment are limited. Many modalities have been introduced for the treatment of avascular necrosis of talus. The prolonged non-weight bearing for 2~3 years is not practical but also is occasionally complicated by late segmental collapse. Operative treatment includes tibiotalar arthrodesis and talectomy with tibiocalcaneal arthrodesis, but arthrodesis in patients with talar avascular necrosis is technically demanding and cause stiff, immobile foot and relatively high failure rate was reported. It is desirable to preserve their original joint if possible. Vascularized fibular grafting has been reported as a joint preserving treatment option for osteonecrosis of the hip but has not been described for the ankle. The authors applied free vascularized fibular grafts for 3 cases of avascular necrosis of talus. We observed evidences of revascularization of necrotic talar body and progression of fracture healing and obtained satisfactory results at mean 8 months of follow-up. Vascularized fibular grafting is one of the better alternatives for treating avascular necrosis of talus. It is expected that vascularized fibular grafting can prevent the necrotic talar dome from progressing to collapse and promote directly restored vascularization and new bone formation.

  • PDF

Psoas Compartment Block for the Relief of Lumbar and Left Thigh Pain after Operation of Second Lumbar Compression Fracture -A case report- (척추 수술 후 발생된 요부 및 좌측 대퇴전부 통증 치료를 위한 대요근 근구 차단술의 효과 -증례 보고-)

  • So, Keum-Young;Park, You-Jin;Koog, Jong-Soo
    • The Korean Journal of Pain
    • /
    • v.11 no.2
    • /
    • pp.314-316
    • /
    • 1998
  • Psoas compartment block has been used to provide anesthesia and analgesia of hip joint. This block is advocated for relief of pain of various origins in the thigh, leg and lumbar area. A-40-year-old women complained of pain in the left thigh and lumbar area after operation of the second lumbar vertebral compression fracture. To relieve pain, caudal block was performed. This block reduced in lumbar pain but left thigh pain persisted. So, we were performed psoas compartment block using mepivacaine and dexamethasone, which relieved the pain in the left thigh and lumbar area. We recommend psoas compartment block as useful and simple method for patients with thigh and lumbar area pain, especially when the epidural block is not feasible.

  • PDF

Study on Injury Risk Factors of the Elderly for Safety·Security Design (안전·안심디자인을 위한 고령자의 손상 위험요인에 관한 연구)

  • Kim, Mi-Young
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.2
    • /
    • pp.105-112
    • /
    • 2017
  • This study recognizes it as a social problem that can be prevented by basic research on safety security design for the elderly, and aims to clearly analyze risk factors for injury. For this study, raw data from the 6th Korean National Health and Nutrition Survey were employed and analyzed. Their social characteristics were classified with standards including gender, education, EuroQoL(human locomotion, normal activity and pain uncomfortableness), the quality of life(PHQ-(1)(2)(4)), recognition on stress, activity restriction status and associated causes(bone fracture and joint injury). Their epidemiological traits were chronic diseases, 'diabetes and hip-joint pain', and health-behavioral traits were 'smoking, breakfast frequency and high-level physical activity status.' In conclusion, it can be found that damage risk of elderly rose in case of female, lower education, inconvenience or limitation, pain or discomfort in locomotion and daily activities, higher recognition of stress, lower interest in work, feeling of depression, despair, and weariness, restriction in activity caused by bone fracture and joint injury, having diabetes and hip-joint pain, smoking, low frequency in having breakfast and high-level physical activities. Based on this study, we envision that an effective solution for injury risk factors caused by the organic relation can be reached in the near future.

The Diagnosis of Rheumatologic and Degenerative Arthritis by X-ray Sacroiliac Joint Projection (X-ray 엉치엉덩관절 촬영법을 통한 류마티스 및 퇴행성관절염 진단)

  • Lee, Jun-Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.397-402
    • /
    • 2018
  • The study best image for diagnosis of fracture, dislocation and unilateral degenerative arthritis of the Sacroiliac joint, this study was performed to obtain the best image of the joint space of the hip joint by giving angle change to the pelvis phantom and the x-ray tube. I received evaluation. The results of the Receiver Operating Characteristic that in the case of simple photographs for the detection of joint arthritis and degenerative arthritis in the prone position, the photograph taken in the prone position raises the buttocks of the opposite side of the test by $25^{\circ}{\sim}30^{\circ}$ and the x-ray tube is perpendicular to the sagittal plane passing 2.5 cm inward from the thorny vertebra In the lying position, lift the Sacroiliac joint of the test side by $25^{\circ}{\sim}30^{\circ}$, and take a $5^{\circ}$ angle of the x-ray tube angle toward the foot toward the center of the upper bruch spine from it will be helpful to diagnose arthritis. the center of the upper bruch spine to the side of the ankle joints in the transverse direction And posterior direction, it will be helpful to diagnose arthritis.

Comparative Study of Compliance for Venous Thromboembolism Prophylaxis (American College of Chest Physicians Guideline and American College of Orthopedic Surgeons Guideline) in High Risk Patients with a Venous Thromboembolism (정맥혈전 색전증 고위험군에서 시행한 혈전색전 예방요법(American College of Chest Physicians 지침 및 American College of Orthopedic Surgeons 지침)의 준수율 비교 연구)

  • Suh, You-Sung;Nho, Jae-Hwi;Jang, Byung-Woong;Kang, Deokwon;Won, Sung-Hun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.4
    • /
    • pp.317-326
    • /
    • 2019
  • Purpose: To compare and analyze the rate of prevention of two venous thromboembolism prophylaxis guidelines in patients with artificial joint arthroplasty and hip joint fracture. Proper prophylaxis for preventing thromboembolism in orthopedic surgery is significant because of this fetal complication. Materials and Methods: This study compared and retrospective analyzed the rate of prevention using the medical records and radiographs of patients who underwent orthopedic surgery from March 2009 to February 2011 according to the American College of Chest Physicians (ACCP) guidelines and from March 2012 to February 2014 according to the American Academy of Orthopedic Surgeons (AAOS) guidelines. Results: The guidelines for venous thromboembolism prophylaxis have been applied to patients with artificial joint replacement and hip joint fracture, the compliance rate of the ACCP guidelines was 56.0% before surgery, 67.0% after surgery with chemical prophylaxis, and 80.5% with mechanical prophylaxis. In addition, the compliance rate of the AAOS guidelines was 74.1% with chemical prophylaxis, and 88.3% with mechanical prophylaxis, which was higher than the ACCP guidelines. The compliance rates of mechanical and chemical prophylaxis before and after surgery of the ACCP guidelines, and the compliance rate of mechanical and chemical prophylaxis of the AAOS guidelines were compared and analyzed. The results revealed statistical significance (p<0.05) before and after total knee replacement arthroplasty and hip joint fracture internal fixation and total high risk orthopedic surgery. Conclusion: Raising the compliance rate of prophylaxis of venous thromboembolism in high risk orthopedic surgery is necessary and people should follow the guidelines for a unified direction depending on which situation they are in.

Predicted the behavior of the femur according to the loading condition using FEM (유한요소해석을 이용한 하중조건에 따른 대퇴골의 거동예측)

  • Song, Seung-Youp;Choi, Seong Dae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.12 no.4
    • /
    • pp.3-9
    • /
    • 2013
  • Falling related injuries are categorized as the most serious and common medical problems experienced by the elderly. Hip joint fracture, one of the most serious consequences of falling in the elderly, occurs in only about 1% of falling. In this study, according to the loading conditions, the analysis is the behavior of the femur. The CT images using the commercial program "Mimics" the bones of three-dimensional CAD data generated, and we will analyze the results of finite element analysis. The boundary conditions on the basis of existing research has been simplified. In this paper, the whole femur was assumed to be isotropic linear elastic material. Predicted the behavior of the femur according to the loading condition, it can be help the development of high-precision artificial bones and joints can be treated with surgery and will be able to perform efficiently.