• Title/Summary/Keyword: Hip internal rotation

Search Result 76, Processing Time 0.025 seconds

Development of Hip Joint Simulator to Evaluate The Wear of Biomaterials Used in Total Hip Joint Replacement (인공고관절 생체재료 마멸평가를 위한 시뮬레이터 개발)

  • 이권용;윤재웅;전승범;박성길
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.06a
    • /
    • pp.265-270
    • /
    • 2001
  • Hip joint simulator which Is an essential device for evaluating the wear of biomaterials (ultrahigh molecular weight polyethylene, Co-Cr alloy, alumina, etc.) used in total hip joint replacement was developed. This hip joint simulator mimics the joint motion and joint loading of human gait by adapting the 4 degree of freedom in kinematic motion (flexing/extension, adduction/abduction, Internal rotation/external rotation) and axial loading, Four stations are operated by 8 servo-motors and harmony drives. Joint leading was imposed by displacement control from a ball screw, LM guide, and spring system. Each kinematic link system operates separately or coupled modes. A heater and a thermocouple were installed for keeping the body temperature in each station.

  • PDF

Range of Motion and Isokinetic Strength of Hip Joint in the College Women with Idiopathic Genu Vara (특발성 내반슬 여대생의 고관절 가동범위와 등속성 근력)

  • Kim, Che-Young;Lim, Seung-Kil
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.10
    • /
    • pp.210-217
    • /
    • 2014
  • This study is to present objective data for the approaches of therapeutic exercise for the correction of genu varum by making an analysis and a comparison of the hip joints' ROM and isokinetic muscles of the female college students with straight legs with those of a female college student with idiopathic genu varum. Additionally, the state of the adductor muscle's thighs and the deep muscles of the subjects with bowed legs were experimented and the equipment's effect and applicability was reviewed through the process of the movement of newly developed exercise equipment, Balloa(2013, Balloa/Adonia/Korea). As a result, a person with genu varum needs the height increasing method for increasing external rotation ROM of a hip joint and requires the exercise techniques to strengthen external rotator muscles and to inhibit the activity of internal rotator muscles of a hip joint. Balloa increases the external rotation ROM of a hip joint and strengthens gluteal muscles, deep muscles, and adductor muscles, and the equipment's function of muscle strengthening shows that the equipment is an effective corrective exercise for the patients of genu varum.

The Relationship Between the Range of Hip Rotation and the Quadriceps Angle in Subjects With and Without Flat Foot

  • Lee, Keun-hyo;Chon, Seung-chul
    • Physical Therapy Korea
    • /
    • v.25 no.4
    • /
    • pp.19-26
    • /
    • 2018
  • Background: Alignment of the lower limb is an important factor, influencing balance and gait in kinematics and kinetics, in patients with and without a flat arched foot. Flat arched foot are associated with the range of motion (ROM) of the hip and alignments of the knee joints, is strongly influenced. Objects: The purpose of this research was to investigate the relationship between hip joint ROM and quadriceps angle (Q-angle), by dividing them into two groups according to the presence or absence of flat feet, using a navicular drop test (NDT) and resting calcaneal stance position (RCSP). Methods: Forty elderly patients were allocated to the experimental group (flat foot group, n1=20) or the control group (non-flat group, n2=20). Universal and digital goniometer, tractograph and tape measure were used to determine the related changes in the hip ROM, Q-angle, NDT and RCSP. Results: Data were analyzed using the Pearson correlation coefficients. Active internal ROM of the hip joint (right, r=.803, p<.001), (left, r=.951, p<.001) were highly correlated with NDT, and also, was moderately correlated with Q-angle (right, r=.562, p=.019), (left, r=.757, p<.001). Passive internal ROM of the hip joint (right, r=.742, p=.001), (left, r=.922, p<.001) were highly correlated with NDT, and also, was moderately correlated with RCSP (right, r=-.530, p=.029) and with Q-angle (right, r=.710, p=.001), (left, r=.698, p=.002) in the flat foot group. However, no strong correlation among the hip ROM, NDT, RCSP and Q-angle were found in the non-flat foot group. Conclusion: This research may provide evidence of the correlations between hip internal ROM and flat foot.

Effect of Physiotherapeutic Intervention Using TECAR Therapy on Pain Self-Awareness and Hip Joint Function in Hip Impingement Syndrome: A Case Study

  • Oh, Dong-Gun;Kim, Seon-Ki;Yoo, Kyung-Tae
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.16 no.3
    • /
    • pp.45-53
    • /
    • 2021
  • PURPOSE: The current case study focuses on identifying the effects of the independent application of TECAR therapy and physiotherapeutic intervention using TECAR therapy on pain self-awareness and hip joint function in patients with hip impingement syndrome caused by nonstructural changes. Subjects: The research subject was a 34-year-old woman struggling with acute pain in her left hip, difficulty in actively moving the hip, and a problem in its overall function. METHODS: The subject's pain awareness and hip joint function were measured using a Visual Analog Scale (VAS) and passive range of motion (PROM), respectively. The experimental intervention was carried out in 24 sessions of 16 minutes each, three times a week, for eight weeks. RESULTS: The VAS score decreased to 0 cm on the post-test from 4.3 cm, 6.5 cm, and 7.2 cm in the pre-test at the rest, standing, and gait positions, respectively. The index of PROM measured hip joint flexion, extension, abduction, adduction, internal rotation, external rotation, and passive straight leg raise. The values increased to 122.5°, 24.5°, 78°, 33°, 65°, 42°, and 96.5° in the post-test compared to 88.5°, 15°, 39°, 21.5°, 23°, 22°, and 46.5° in the pre-test, respectively. CONCLUSION: TECAR therapy and physiotherapeutic intervention using TECAR can help reduce pain and enhance the hip joint function in patients with hip impingement syndrome.

A Case Study of a Female Patient with Patellofemoral Pain Syndrome for Effect of Hip Joint Traction and Hip Posterolateral Muscles Strengthening on Knee Pain, Range of Motion, and Lower Extremity Function Scale (슬개대퇴통증 증후군 환자에게 적용한 고관절 견인과 근력 강화 운동이 무릎 통증, 관절가동범위, 하지기능에 미치는 영향-사례 연구)

  • Hong, Hyun-Pyo
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.20 no.1
    • /
    • pp.35-38
    • /
    • 2014
  • Background: The case study examined the effect of a hip joint traction and hip posterolateral muscles strengthening on knee pain, range of motion, and lower extremity function scale of patients with patellofemoral pain syndrome (PFPS). Although PFPS has previously been attributed to quadriceps dysfunction, more recent research has linked this condition to impairment of the hip musculature and kinematic. Methods: Subject is a 27-years-old female with PFPS. Performed hip joint traction with belt and posterolateral muscles(hip abductors, external rotators) strengthening for 4 weeks, 3 times a week, once a day. Before and after the therapy, measurements were made on the visual analog scale (VAS) and of the ROM, and a lower extremity functional scale (LEFS) was conducted. Results: The results showed positive changes in VAS and range of motion and lower extremity functional scale. First VAS of knee changed from 6 to 2. Second hip joint range of motion showed that internal rotation recored from $53^{\circ}$ to $58^{\circ}$ and external rotation recorded from $32^{\circ}$ to $37^{\circ}$. Third The lower extremity functional scale showed before therapy of 44; after therapy, 63. Conclusion: The hip joint traction and hip posterolateral muscles strengthening was effective in alleviating knee pain, increasing ROM and Lower extremity functional scale of the PFPS patients.

Effect of Sagittal Pelvic Tilt on Kinematic Changes of Hip and Knee Joint During Sit-to-Stand (일어서기 동작 시 시상면 골반 기울임이 엉덩관절과 무릎관절의 운동형상학에 미치는 영향)

  • Lim, In-Hyuk;Choi, Bo-Ram;Kim, Hyun-Sook
    • Physical Therapy Korea
    • /
    • v.18 no.3
    • /
    • pp.26-37
    • /
    • 2011
  • Although there have been various studies related to the body's movement from a sitting to a standing position (sit-to-stand task), there is limited information on the kinematic changes on the frontal and transverse planes. The purpose of this study was to ascertain how pelvic tilt affects kinematic changes in the frontal and transverse planes in the hip and knee joints during a sit-to-stand task. For this study, 33 healthy participants (13 female) were recruited. Each participant rose from a sitting to a standing posture at his or her preferred speed for each of three different pelvic tilt trials (anterior, posterior, and neutral), and the measured angles were analyzed using a 3-D motion analysis system. A one-way repeated measure analysis of variance was performed with Bonferroni's post hoc test. In addition, an independent t-test was carried out to determine the sex differences in hip and knee joint kinematic changes during the sit-to-stand tasks. The results were as follows: 1) The hip and knee joint angle in the frontal and transverse planes showed a significant difference between the different pelvic tilt postures during sitting in the pre-buttock lift-off phase (pre-LO) (p<.05). Compared to the posterior pelvic tilt posture, the anterior pelvic tilt posture involved significantly greater hip joint adduction and internal rotation, knee joint adduction, and reduced internal rotation of the knee joint. 2) Sex differences were found with significant differences for males in the initial and maximal angles in the frontal plane of the hip and knee joint (p<.05). Females had a significantly smaller initial abduction angle of the hip joint and a significantly greater maximal angle of the hip adduction joint. These results suggest that selecting a sit-to-stand exercise for pelvic tilt posture should be considered to control abnormal movement in the lower extremities.

Effect of Artificial Leg Length Discrepancy on 3D Hip Joint Moments during Gait in Healthy Individuals (건강한 성인에서 인위적 다리길이 차이가 보행 중 3차원 엉덩관절 모멘트에 미치는 효과)

  • Jo, Min-Ji;Kim, Dong-Hyun;Han, Dong-Wook;Choi, Eun-Jin;Kim, Ye-Seul;Kim, Yong-Wook
    • PNF and Movement
    • /
    • v.17 no.3
    • /
    • pp.391-399
    • /
    • 2019
  • Purpose: This study investigated the three-dimensional moment values of the hip joint for subjects with artificial leg length alterations and subjects with unaltered leg lengths. Methods: Forty-two healthy adults (8 men, 34 women) participated in this study. The selected subjects were able to walk normally, had less than a 1 cm leg length discrepancy, and were instructed to wear shoes that fit their feet. The study participants performed 8 dynamic gait trails to measure the hip joint moment using a three-dimensional motion analysis system. Kinetic and dynamic three-dimensional gait analysis data were collected from infrared cameras, and a force plate was used to standardize the weight of each subject. Results: There were significant correlations between the differences in the leg length discrepancy during right extension, right flexion, right internal rotation, and left extension in hip joint moments (p<0.05). There were significant correlations between the differences in shoe conditions during left extension, right flexion, right extension, and right internal rotation in the hip moments (p<0.05). Conclusion: This study suggests that a leg length discrepancy can affect hip joint moment, which may further exacerbate musculoskeletal disorders, such as osteoarthritis in lower extremity joints. Therefore, further studies should be conducted to verify the impact of clinical interventions on differences in hip joint moment values to correct leg length discrepancies and prevent osteoarthritis in lower extremity joints.

Reliability Study of Hip Range of Motion Measurement by Smartphone Inclinometer (스마트폰 경사계를 사용한 엉덩관절 가동범위의 측정 신뢰도 연구)

  • Yang, Hoesong;Jeong, Chanjoo;Yoo, Youngdae;Bae, Seahyun
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.4 no.2
    • /
    • pp.89-96
    • /
    • 2016
  • Purpose : The purpose of this study was to evaluate inter-tester reliability and Intra-tester reliability about range of motion(ROM) measurement of hip joint with smartphone inclinometer. Method : Six observers performed goniometric and smartphone inclinometer measurements of various hip movements, including both active ROM for flexion, extension, external rotation, internal rotation. Measurements were performed in the right hip of fifty normal subjects. All measures were performed three times for evaluating reliability of observer. Inter- and intra-observer reliabilities were evaluated using the intraclass correlation coefficient(ICC). Result : The results were as follows, inter-observer reliability ICC value showed .948-.974 in smartphone inclinometer. And showed .781-.827 in goniometer. Intra-observer reliability ICC value showed .653-.992 in smartphone inclinometer. And showed .613-.854 in goniometer. Conclusion : Smartphone inclinometer are portable and widely available tools that are mostly reliable and valid for assessing active hip range of motion, with potential use when a goniometer is not available.

Effects of Kinematics and Kinetics of the Lower Extremities Joint during Drop Landing in Adult Women with Patellofemoral Pain Syndrome (슬개대퇴동통증후가 성인 여성의 드롭랜딩 시 하지 주요관절의 운동역학적 변화에 미치는 영향)

  • Jeon, Kyoungkyu;Yeom, Seunghyeok
    • Korean Journal of Applied Biomechanics
    • /
    • v.31 no.1
    • /
    • pp.64-71
    • /
    • 2021
  • Objective: This study investigated the different in isokinetic peak strength of the knee joint, and kinetics and kinematics in drop landing pattern of lower limb between the patellofemoral pain syndrome (PFPS) patients and normal. Method: 30 adult females were divided into the PFPS (age: 23.13±2.77 yrs; height: 160.97±3.79 cm, weight: 51.19±4.86 kg) and normal group (age: 22.80±2.54 yrs, height: 164.40±5.77 cm, weight: 56.14±8.16 kg), with 15 subjects in each group. To examine the knee isokinetic peak strength, kinematics and kinetics in peak vertical ground reaction force during drop landing. Results: The knee peak torque (Nm) and relative strength (%) were significantly weaker PFPS group than normal group. In addition, PFPS group had significantly greater hip flexion angle (°) than normal group. Moreover, normal group had significantly greater moment of hip abduction, hip internal rotation, and left ankle eversion than PFPS group, and PFPS group had significantly greater moment of knee internal rotation. Finally, there was significant differences between the groups at anteroposterior center of pressure. Conclusion: The PFPS patients had weakened knee strength, and which can result in an unstable landing pattern and cause of more stress in the knee joints despite to effort of reduce vertical ground reaction force.

A Study of Comparison of Pelvic Alignment, Hip Joint Range of Motion About 20's Female University Students' With Dysmenorrhea (여대생의 월경곤란증 정도에 따른 골반정렬과 고관절 가동범위의 비교연구)

  • Choi, Im-soon;Jang, Hyun-jeong
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.21 no.2
    • /
    • pp.47-52
    • /
    • 2015
  • Background: The objective of this study was to compare dysmenorrhea with pelvic alignment, hip joint range of motion about 20's female university students. Sixty two female students participated in this study. To investigate the measure of dysmenorrhea, we used modified menstrual distress questionnaire (MMDQ) and numerric rating scale (NRS). The pelvic alignment was assessed by using the palpation meter. The active range of motion (ROM) were assessed by measuring the flexion, extension, abduction, adduction, internal rotation and external rotation. Each measurement was assessed by goniometer. The data were analyzed by calculating independent T-test. Consequently, As the increase of dysmenorrhea, we observed significantly the increase of pelvic anterior tilt in right and left pelvic (p<.05). Otherwise, as the increase of dysmenorrhea, range of motion of hip joint was significantly limited in right and left external rotation (p<.05). Thus, this study provides young female with valuable information about dysmenorrhea.

  • PDF