• Title/Summary/Keyword: High-volume

Search Result 6,457, Processing Time 0.032 seconds

Spalling and Internal Temperature Distribution of High Strength Column Member with Polypropylene Fiber Volume Fractions (폴리프로필렌섬유 혼입률에 따른 고강도콘크리트 기둥부재의 폭렬 및 내부온도 분포특성)

  • Won, Jong-Pil;Jang, Chang-Il;Lee, Sang-Woo;Kim, Heung-Youl;Kim, Wan-Young
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.6
    • /
    • pp.821-826
    • /
    • 2008
  • This study evaluated spalling and internal temperature distribution after elevated temperatures test for high strength concrete ($f_{ck}=60\;MPa$) column member with various polypropylene fiber volume fractions. The ISO-834 time-temperature curve was used for measurement of fire resistance properties. As the result of test, average internal temperature results indicated to low temperature in increased polypropylene fiber volume fraction. But, the highest internal temperature results show that does not difference in proportion of polypropylene fiber volume fractions.

Evaluation of a Method for the Measurement of PAHs in the Ambient Atmosphere - Focusing on High Volume Sampling and GC/MS Analysis (대기 중 다환방향족탄화수소 측정방법의 성능평가 - 하이볼륨 샘플링 및 GC/MS 분석방법을 대상으로)

  • Seo, Young-Kyo;Park, Dae-Kwon;Baek, Sung-Ok
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.4
    • /
    • pp.322-333
    • /
    • 2009
  • In this study, a measurement method was evaluated for the determination of polycyclic aromatic hydrocarbons (PAHs) in the ambient atmosphere. PAHs were sampled by high-volume samplers, and were then analysed with a GC/MS system. Particulate PAHs were collected on $8"{\times}10"$ quartz fiber filter, while vapor phase PAHs were adsorbed on polyurethane foam (PUF). Target compounds included a total of 36 PAHs, which are known to be frequently detected in the urban atmosphere. It was not necessary to clean-up samples before samples were analyzed using GC/MS, and the overall performance of the method was tested by a variety of quality control and quality assurance schemes. It is generally known that the clean-up procedure can negatively affect the recovery of samples. Precision and accuracy was evaluated using SRM provided by US NIST, and the results were generally satisfactory and reliable. However, the GC/MS method appeared not to be adequate for 6-rings PAHs, such as coronene, due to its lower sensitivity. In addition, collection efficiencies for low molecular compounds, such as 2-rings PAHs, were poor because of the lower retention volume of the PUF adsorbent. As a result, it was concluded that the method based on high-volume sampling and GC/MS analysis can give very reliable data by simultaneous sampling of both particulate and vapor phases for 3-rings to 5-rings PAHs of environmental concern.

Effects of Micropores on the Freezing-Thawing Resistance of High Volume Slag Concrete (슬래그를 다량 치환한 콘크리트의 동결융해 저항성능에 미치는 미세공극의 영향)

  • Kim, Rae-Hwan;Kim, Gyu-Yong;Lee, Bo-Kyeong;Shin, Kyoung-Su;Song, Gwon-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.4
    • /
    • pp.67-74
    • /
    • 2015
  • In this study, effects of micropores on the freezing-thawing resistance of high volume slag concrete are reviewed. Concrete was made with slag which contains the ground granulated blast furnace slag(GGBS) and the pig iron preliminary treatment slag(PS) by replacing 0, 40, 70 %, then compressive strength, freezing-thawing resistance, micropores were reviewed. Also, specified design strength, target air contents were set. Deterioration was induced by using 14-day-age specimen which has low compressive strength for evaluating deterioration by freeze-thawing action. As results of the experiment, despite of specified design strength which has been set similarly and ensured target air contents, the pore size distribution of the concrete showed different results. Micropores in GGBS70 specimen have small amount of water which is likely to freeze because there is small amount of pore volume of 10~100 nm size at 0 cycle which has not been influenced by freezing-thawing. For these reasons, it was confirmed that the freezing-thawing resistance performance of GGBS70 is significantly superior than other specimens because relatively small expansion pressure is generated compared to the other specimens.

Effect of Emulsified Refine Cooking Oil and Expandable Microsphere on Durability of High-Volume Blast Furnace Slag Concrete (정제유지류 및 팽창성 인공 기포 조합이 고로슬래그 다량치환 콘크리트의 내구성 및 미시적 특성에 미치는 영향)

  • Han, Min-Cheol;Han, Dongyeop;Lee, Myung-Ho
    • Journal of the Korea Institute of Building Construction
    • /
    • v.15 no.2
    • /
    • pp.201-207
    • /
    • 2015
  • In this paper, a series of experiments was conducted to evaluate the resistibility of carbonation and freeze-thawing damage of the high-volume blast furnace slag concrete using expancel, the expandable microsphere, and ERCO, emulsified refine cooking oil. The concrete mixture of 0.45 water-to-binder ratio with 60% of blast furnace slag was evaluated for carbonation, freeze-thawing resistibility, SEM, and porosity. According to the previous research, replacing ERCO contributes on improving carbonation resistibility with capillary pore filling effect by soap foaming reaction of ERCO while significantly decreased freeze-thawing resistibility. To improve this decreased freeze-thawing resistibility, expancel was used, and thus freeze-thawing resistibility was improved as the replacement ratio of expancel was increased. It is considered that the selective volume shrunken effect of expancel due to the external pressure and decreased air void spacing factor due to expancel.

Effect of Initial Volume of Hard Water and Contact Time on the Reduction of Calcium Ion Concentration using High Voltage Impulse Technique (고전압 임펄스 기술을 활용한 경도 제거에서 경수의 초기부피와 인가시간이 칼슘이온 농도에 미치는 영향)

  • Cho, Seung-Yeon;Kim, Tae-Hui;Chang, In-Soung;Hong, Woong-ki;Lee, June-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.7
    • /
    • pp.1066-1071
    • /
    • 2017
  • Recently high voltage impulse (HVI) technique has been extensively studied for desalting processes to control the $CaCO_3$ scale formation in industrial water practices such as power plant, boiler, and heat exchange operations. Investigation of the operational parameters for the HVI is important, however, those had not been reported yet. In this study, the effect of initial feed volume and contact time on reduction of calcium ion concentration by the HVI technique was investigated. Initial feed volumes of artificial hard water which contained 100 mg/L of $Ca^{2+}$, were set to 1, 2, and 3 L respectively. After 24hr of HVI contact with 12kV, $Ca^{2+}$ ion was reduced to 50, 29 and 19 % of their initial concentration, indicating that calcium removal increased as initial feed volume decreased. This implies the applied HVI pulse energy per unit mass of calcium is important parameter determining overall desalting efficiency. A series of extended operations of HVI up to 30 days verified the long term stability of the HVI system. The calcium ion declined to 40 mg/L after 2~3 days, and further reduction of calcium was not achieved, indicating that optimum operation time could be 2~3 days under these experimental conditions. Consequently, it was confirmed that the important operational parameter of HVI technique is initial feed volume and contact time as well as the applied voltage that was already proven in the previous study.

Preparation and Characterization of high-quality activated carbon by KOH activation of pitch precursors (KOH 활성화에 의한 피치계 고품질 활성탄의 제조 및 특성)

  • Lee, Eun-Ji;Kwon, Soon-Hyung;Choi, Poo-Reum;U, Jong-Pyo;Jung, Ji-Chul;Kim, Myung-Soo
    • Journal of the Korean Applied Science and Technology
    • /
    • v.31 no.3
    • /
    • pp.408-415
    • /
    • 2014
  • In order to prepare high-quality activated carbons (ACs), coal tar pitch (CTP), and mixtures of CTP and petroleum pitch (PP) were activated with KOH. The ACs prepared by activation of CTP in the range of $700{\sim}1000^{\circ}C$ for 1~5 h had very porous textures with large specific surface areas of $2470{\sim}3081m^2/g$. The optimal activation conditions of CTP were determined as CTP/KOH ratio of 1:4, activation temperature of $900^{\circ}C$, and activation time of 3 h. The obtained AC showed the highest micro-pore volume, and pretty high specific surface area and meso-pore volume. The micro-pore volumes and specific areas of activated mixtures of CTP and PP were similar to each other but the meso-pore volume could be increased. In order to change the degree of crystallinity of precursors before KOH activation process, the CTPs were carbonized in the range of $500{\sim}900^{\circ}C$. As the carbonization temperature increased, the specific surface area and pore volume of the activated ACs with the same activation conditions for CTP decreased dramatically. It was demonstrated that the increased pore size distribution of AC electrodes in the range of 1 to 2 nm plays an important role in the performance of electric double-layer capacitor.

Degree of Enteral Tube Feeding in the Intensive Care Unit and Change in Nutritional Status (병원 중환자의 경관유동식 공급 현황 및 영양상태 변화)

  • Im, Hyeon-Suk;Park, Eun-Gyeong;Lee, Jong-Ho
    • Journal of the Korean Dietetic Association
    • /
    • v.7 no.3
    • /
    • pp.217-226
    • /
    • 2001
  • It is important to supply adequate nutrition to critically ill patients, whose gastrointestinal system is properly functioning, through the enteral tube feeding if oral intake is impossible. In this study we investigated the changes in nutritional status with enteral tube feeding according to the volume required. We investigated the volume ordered according to the patient's requirements, volume infused according to the volume ordered in 41 enteral tube feeding patients in intensive care unit from Jannuary to July, 2000. Body weight, serum albumin level, and total lymphocyte count were evaluated to assess nutritional status. The mean fasting period was 5 days before the enteral feeding and patients whose fasting period over 3 days were 51%. The mean enteral tube feeding period was 29 days and method of feeding was nasogastric, bolus feeding 6 times per day. The volume ordered was 69.7% of the patients' recommended calorie and volume infused was 86.6% of their volume prescribed. Accordingly, the volume infused was estimated 61.7% of their volume required. Only 44.6% of their reqiured volume was infused within 3 days after enteral tube feeding was started. It took 16 days in average to meet the patients' recommended calorie; 56% of subjects still did not fully met their requirements by the end point. Among the impeding factors in supplying enteral tube feeding, factors related to the number of feeding were high residual volume in stomach, vomiting, gastrointestinal bleeding, abdominal distension and surgery. Factors related to the acctual infused volume were diarrhea, gastrointestinal bleeding, abdominal distension, airway management and tube reinsertion. Significant correlations were shown between the volume infused and changes in both the patients' weight and serum albumin level. Deviding the subjects into two groups by their infused volume, less than 70% and more than that, we compared the two to come up with a significant difference in their serum albumin level, -0.23 vs 0.21, and their body weight, -4.52 vs 0.12. In enteral tube feeding, the volume delivered in sufficient to the pateints' energy requirement can affect their nutriitional status in critically ill patient; adequate nutritional management plan is essential. It is necessary to make every effort to educate clinical staff and to set up a unified management program to prescribe adequate ammount of energy for the patient's nutritional requirement.

  • PDF

Relationships between Cell Bio-volume and Growth Rate of Dominant Red Tide Organisms in the Coastal Water (연안내만해역에서 우점하는 주요적조생물의 성장과 세포체적의 관계)

  • Baek, Seung-Ho;Joo, Hae-Mi
    • Korean Journal of Environmental Biology
    • /
    • v.30 no.1
    • /
    • pp.1-8
    • /
    • 2012
  • To understand growth characteristics of eight dominant red tide species ($Prorocentrum$ $minimum$, $Heterocapsa$ $triquetra$, $Scrippsiella$ $trochoidea$, $Akashiwo$ $sanguinea$, $Chattonella$ $marina$, $Heterosigma$ $akashiwo$, $Amphidinium$ $carterae$ and $Rhodomonas$ $salina$) in the Korean coastal water, the growth rates were examined in relation with the impacts of water temperature and bio-volume. Of these, $P.$ $minimum$, $C.$ $marina$, $H.$ $akashiwo$, $A.$ $carterae$ and $R.$ $salina$ were eurythermal species with relatively high growth rates in a borad ranges (15 to $25^{\circ}C$) of water temperature. On the other hand, the growth rate of $H.$ $triquetra$, $S.$ $trochoidea$ and $A.$ $sanguinea$ were high in relatively mid temperature (optimum: $25^{\circ}C$) condition. In particular, $H.$ $triquetra$ was well adapted in low temperature of 5 to $15^{\circ}C$, implying that the species can survive and grows even at very low temperature. Based on results of our experiment, the growth characterestics of five eurythermal species and three mid temperature species may have dominated in Korean coastal water during summer season and fall season, respectively. Contrastively, the growth characteristics of $H.$ $triquetra$ make a consistently dominant during the cold winter season. In addition, the growth rates of large bio-volume species were lower than those of small bio-volume species, indicates that growth of single cells of several flagellates might be depended on the cells sizes.

A Stereo Image Recognition-Based Method for measuring the volume of 3D Object (스테레오 영상 인식에 기반한 3D 물체의 부피계측방법)

  • Jeong, Yun-Su;Lee, Hae-Won;Kim, Jin-Seok;Won, Jong-Un
    • The KIPS Transactions:PartB
    • /
    • v.9B no.2
    • /
    • pp.237-244
    • /
    • 2002
  • In this paper, we propose a stereo image recognition-based method for measuring the volume of the rectangular parallelepiped. The method measures the volume from two images captured with two CCD (charge coupled device) cameras by sequential processes such as ROI (region of interest) extraction, feature extraction, and stereo matching-based vortex recognition. The proposed method makes it possible to measure the volume of the 3D object at high speed because only a few features are used in the process of stereo matching. From experimental results, it is demonstrated that this method is very effective for measuring the volume of the rectangular parallelepiped at high speed.

A Study on the Improvement of Accuracy in Mapping the Distribution of the Emission Volume of Air Pollution Using GIS (GIS를 이용한 대기오염 배출량 분포도의 정확도 향상에 관한 연구)

  • 최진무
    • Spatial Information Research
    • /
    • v.6 no.1
    • /
    • pp.65-76
    • /
    • 1998
  • Air contaminant density must be inferred exactly to manage air pollution. Each land use of air pollution source is duplicated in the existing air contaminant distribution because the resolution of the land use map is low. The purpose of this study is to understand how the land use map is used to determine effectively in the distribution calculation of the emission volume and the inference of air contaminant density, as it is made in a high resolution. The major findings are as follows : In this study, as to making a high resolution($28.5m{\times}28.5m$) map of land use with GIS, each air pollution source is not duplicated spatially and land use can be reflected effectively. In Seoul, each air contaminant density was inferred (using a TCM-2 model) with the existing distribution map of emission volume, whose resolution is $1km{\times}1km$, and the new distribution map of emission volume, whose resolution is $28.5km{\times}28.5km$. According to the result, the inference value of the new distribution map was more similar to the actual value of an automatic survey network.

  • PDF