• 제목/요약/키워드: High-to-low ratio

검색결과 5,693건 처리시간 0.034초

유기물 조성에 따른 알루미나 테이프의 열간 가압 거동 (Effect of Organic Additive Composition on Isostatic Thermocompression Behavior of Alumina Tapes)

  • 이명현;박일석;김대준;이득용
    • 한국세라믹학회지
    • /
    • 제37권8호
    • /
    • pp.824-831
    • /
    • 2000
  • Alumina tapes, having various ratios of alumina to alumina+binder+plasticizer (a/(a+o)) and binder to binder+plasticizer(b/(b+p)), were prepared by the tape casting method. The tapes were thermocompressed varying the thermocompression parameters such as temperature, pressure, and duration time. Among the parameters, the pressure was the most influential to the tape packing density. The packing density varied in two different ways depending on the a/(a+o) ratio. For the tapes having low a/(a+o) ratio, a saturation density was reached by applying very a low pressure of 1 MPa. For tapes with high a/(a+o), on the contrary, the saturation density was obtained at a relatively high pressure. These different responses to the pressure are attributed to the fact that the rearrangement of alumina particles by the pressure becomes easy as an organic content in the tapes is high.

  • PDF

대형 LPG 엔진의 흡입 스월비에 따른 연소성능에 관한 연구 (The Effect of Intake Swirl Ratios on Combustion Performance in a Heavy-Duty LPG Engine)

  • 한병주;김창업;강건용;이창식
    • 한국자동차공학회논문집
    • /
    • 제9권5호
    • /
    • pp.46-53
    • /
    • 2001
  • To optimize the intake flow condition in the heavy-duty LPG SI engine, five different swirl ratios of intake port were investigated experimentally by oil spot method, LDV and single cylinder engine test. The flow characteristics near the piston surface were observed by oil spot method and magnitudes of swirl flow were measured quantatively by LDV method in the steady flow rig. The engine performances of various swirl flow were also tested with the heavy-duty LPG SI single cylinder engine. In the results, high swirl ratio, above $R_s$=2.3, was not suitable to develope a stable flame kernel and to produce high engine performance. Especially it was more serious under lean burn conditions, since turbulence intensity was smaller than bulk flow though those are increased together. These results were also confirmed by LDV measurement and oil spot method. On the contrary, low swirl ratio($R_s$=1.3) is not good to propagate a flame since the turbulence intensity and bulk flow are vanished during compression stroke and low swirl ratio has too weak initial energy for stable combustion. Therefore, the of optimized swirl ratio f3r the heavy-duty LPG engine in this work was found around $R_s$=2.0.

  • PDF

Atmospheric Photochemistry in Low-and High-NOx Regimes

  • Kim, Do-Yong;Soda, Satoshi;Kendo, Akira;Oh, Jai-Ho
    • 한국환경과학회지
    • /
    • 제16권1호
    • /
    • pp.1-8
    • /
    • 2007
  • Atmospheric photochemistry of $O_3-NOx-RH$ were considered theoretically, to clarify the reasons for the different trends of between the formation of photochemical oxidants (Ox) and its primary pollutants for the Low-and High-NOx regimes. Equations of OH, $HO_2$, and production of ozone ($O_3$) as a function of nitrogen oxides (NOx) and reactive hydrocarbons (RH) were represented in this study. For the Low-NOx regime, $HO_2$ radical is proportional to RH but independent of NOx. OH radical is proportional to NOx but inversely-proportional to RH. $O_3$ production is proportional to NOx but has a weak dependence on RH. For the High-NOx regime, OH and $HO_2$ radicals concentrations and $O_3$ production are proportional to RH but inversely-proportional to NOx. In addition, the Osaka Bay and surrounding areas of Japan were evaluated with the mass balance of odd-hydrogen radicals (Odd-H) using CBM-IV photochemical mechanism, in order to distinguish the Low- and High-NOx regimes. The Harima area (emission ratio, RH/NOx = 6.1) was classified to the Low-NOx regime. The Hanshin area (RH/NOx = 3.5) and Osaka area (RH/NOx = 4.3) were classified to the High-NOx regime.

메탄/공기 대향류 예혼합화염의 NO 발생특성에 관한 수치해석 (A Numerical Analysis of the NO Emission Characteristics in $CH_4/Air$ Counterflow Premix Flame)

  • 조은성;정석호
    • 한국연소학회지
    • /
    • 제9권4호
    • /
    • pp.22-27
    • /
    • 2004
  • Lean premix combustion is a best method in low $NO_x$ gas turbine combustor and we must know the characteristics of NO emission in high temperature and pressure condition in premix flame. Numerical analysis was performed to investigate the NO emission characteristics by adopting a counterflow as a model problem using detailed chemical kinetics. Methane $(CH_4)$ was used as a test fuel which is the main fuel of natural gas. The tested parameters were stretch rate, equivalence ratio, initial temperature, and pressure in premix flame. Results showed that NO emission was high in low stretch rate, near stoichiometric equivalence ratio, high initial temperature, and high pressure. Also, the pressure effect was sensitive in high temperature condition.

  • PDF

Power Efficient Modulation Scheme $CDM^2-MAP$ for Low Complexity and High Performance

  • Khuong Ho Van;Kong Hyung-Yun;Nam Doo-Hee
    • Journal of Communications and Networks
    • /
    • 제8권1호
    • /
    • pp.1-7
    • /
    • 2006
  • Quadrature amplitude modulation-spread spectrum (QAM-SS) and code division multiplexing (CDM) are multi-level modulation schemes with high performance but they cause a large peak-average power ratio (PAPR). Therefore, this paper proposes a novel modulation scheme for high-rate transmission which follows a sequence of CDM-mapping-CDM not only to correct the above-mentioned problem but also offer a high flexibility in obtaining arbitrary multilevel modulation with very low implementation complexity and high performance.

Furosemide 투여후의 뇨중 Aldosterone 농도대 K/Na 비사이의 관계 (A Relation of Urinary Aldosterone Concentration to K/Na Ratio Following Furosemide Administration in Normal Subjects with High Sodium or Low Sodium Intake)

  • 성호경
    • The Korean Journal of Physiology
    • /
    • 제9권2호
    • /
    • pp.33-39
    • /
    • 1975
  • Changes of urinary aldosterone excretion, concurrent sodium and potassium excretion following furosemide administration were studied in normotensive young Korean with high sodium intake, moderate sodium restriction and marked sodium depletion. After intravenous injection of furosemd 40mg, plasma and urine samples were collected at every thirty minutes for two hours. Plasma-and urinary aldosterone, electrolyte concentration and urine flow rate were measured by means of radioimmunoassay or flamephotometry. Relations of urinary aldosterone to concurrent sodium or potassium/sodium ratio, and of urinary aldosterone to concurrent plasma aldosterone activity were studied. Following were the results: 1. Furosemide administration resulted in a increased urinary aldosterone concentration and unchanged or somewhat decreased sodium concentration in course of time after the injection. 2. Urinary potassium concentration showed initial decrease and subsequent increase in course of time after furosemide administration and it resulted in a gradual increase in urinary potassium/sodium ratio. 3. Studying the relations between urinary aldosterone excretion and potassium/sodium excretion ratio, or sodium excretion were meaningless because of the urinary flow rate after the injection was decreased with time course. 4. Furosemide administration showed a good relationship of urinary aldosterone concentration to concurrent potassium/sodium ratio rather than concurrent sodium concentration in subjects with sodium restriction, but no meaningful relationship was detected in subjects with high sodium intake because increasing rate of the ratio was not so wide. 5. Furosemide also resulted a reasonable relation of plasma aldosterone concentration to concurrent urinary aldosterone concentration especially during low sodium intake. 6. Above results suggested that relation of urinary aldosterone concentration to K/Na ratio following furosemide administration during sodium restriction is significant and has a benefit to reduce the variation induced by kalemic change showing in the diragram for daily aldosterone to sodium excretion.

  • PDF

고조파 조절기 형상이 자석 기어의 코깅 자기력에 미치는 영향 분석 (Influence of Harmonic Modulator Shape on the Cogging Force of Magnetic Gear)

  • 정광석
    • 융복합기술연구소 논문집
    • /
    • 제12권1호
    • /
    • pp.7-12
    • /
    • 2022
  • The reduction ratio of the magnetic gear is determined by the ratio of the number of poles between the high-speed permanent magnet layer and the low-speed permanent magnet layer. In general, it is known that the greater the least common multiple of both poles, the smaller the torque ripple called by cogging of the magnetic force generated in the magnetic gear. However, little is known about the effect of the harmonic modulator that filters the magnetic field in the magnetic gear to magnetically couple the high-speed side and the low-speed side except for the number of poles. In this study, torque ripple characteristics according to changes in modulator shape such as opening ratio and tooth thickness are analyzed using a finite element analysis tool.

강성 배분비를 고려한 고강성화 경량화 차체 설계 (Design of High Stiffness and Lightweight Body for Stiffness Distribution Ratio)

  • 양희종;김기창;임시형;김찬묵;임홍재
    • 한국소음진동공학회논문집
    • /
    • 제17권10호
    • /
    • pp.901-906
    • /
    • 2007
  • Lightweight body due to the decrease of panel thickness and reinforcing member might cause low stiffness. On the other hand, high stiffness body requires an increase of mass. Front pillar section area has been decreased for increasing the driver's visual field. Global vehicle stiffness is affected by stiffness distribution ratio between upper part and lower part at a side body structure. This paper describes a process used to evaluate the stiffness distribution ratio based on strain energy. In addition, optimum design schemes are presented for high stiffness and lightweight body structure considering the investigated stiffness distribution ratio.

저압보일러에서 고온의 온수 생성 후 압축기에서 고압수를 생성하는 고온·고압 세척시스템에 관한 연구 (A Study on a High-Temperature/High-Pressure Washing System in which High-Temperature Water is Generated in a Low-Pressure Boiler and High-Pressure Water is Generated Thereafter in a Compressor)

  • 조동현
    • 한국기계가공학회지
    • /
    • 제18권1호
    • /
    • pp.94-100
    • /
    • 2019
  • This study was conducted on a high-temperature/high-pressure washer in which low-pressure cold water in a boiler is heated to a temperature range of $70{\sim}80^{\circ}C$ by supplying diesel combustion heat. The high-temperature water is sent to a compressor to increase its pressure to 200 bar, thereby making high-temperature/high-pressure water, which is sprayed through a spray nozzle. In the results of this study, the spray temperature of the high-pressure washing was shown to be the highest when the ratio between the actual amount of combustible air and the theoretical amount of air was 1:1 and the energy consumption rate of the low-pressure boiler type high-pressure washer was shown to be much lower than that of the high-pressure boiler type high-pressure washer.

대표적인 열분해가스화 용융시설의 공정별 다이옥신 배출거동에 관한 연구 (A study on the Dioxin behavior in the process of representative pyrolysis/gasfication/melting plant)

  • 신찬기;신대윤
    • 환경위생공학
    • /
    • 제22권1호
    • /
    • pp.1-16
    • /
    • 2007
  • The incineration process has commonly used for wastes amount reduction and thermal treatments of pollutants as the technologies accumulated. However, the process is getting negative public images owing to matter of hazardous pollutants emission. Specially dioxins became a main issue and is mostly emitted from municipal solid wastes incineration. In this reason, pyrolysis/gasfication/melting process is presented as a alternative of incineration process. The pyrolysis/gasfication/melting process, a novel technology, is middle of verification of commercial plant and development of technologies in Korea. But the survey about the pollutant emission from the process, and background data in these facilities is necessary. So in this survey, it Is investigated that the behavior of dioxins in three pyrolysis/gasfication/melting plant (S, T, P) of pilot scale. In case of S plant, concentration of dioxins shows high at latter part of cogenerated boiler and stack which are operate on low temperature conditions than a latter parts of pyrolysis and melting furnace which are operate on high temperature condition. Concentration of gas phage dioxins had increased after combusted gas passed cogenerated boiler and this is attributed to react of precursor materials such as chlorobenzene and chlorophenol. Concentration of dioxins in T plant showed lower levels at latter part of cooling equipment which are operate with water spray type on low temperature conditions than a latter parts of gasfied melting furnace which are operate on high temperature condition. Removal efficiency of dioxins at gas treatment equipment was 78.8 %. Concentration of dioxins in P plant was low at latter part of SDA/BF which is operate at low temperature conditions than a latter parts of pyrolysis gasfied chamber which are operate at high temperature condition. Removal efficiency of dioxins of SDA/BF was 85.9 % and therefore, it showed high efficiency at those of stoker type incineration facility. However, concentration of dioxins which emitted at high temperature condition were low in three facilities and satisfied present standard emission level of dioxins. To consider the distribution ratio of dioxins, Particulate phase dioxins at S and P plants showed similar ratio with which shows in current stoker type for middle scale domestic waste incineration facility. It is necessary to continuos monitoring the ratio of distribution of dioxins in T plant in because ratio of gas phage dioxins showed high.