• 제목/요약/키워드: High-temperature piping

검색결과 129건 처리시간 0.019초

루프디자인에 따른 배관시스템의 열응력에 관한 연구 (A Study on Thermal Stress of Power Piping due to Loop Design)

  • 이정현;박지성
    • 한국생산제조학회지
    • /
    • 제23권5호
    • /
    • pp.450-455
    • /
    • 2014
  • Domestic power plants have consistently been developed over the years in industrially developed nations with high standards of living. Considering the power plant development strategy, design efficiency is of upmost importance. Therefore, an improper design directly affects the power plant's risk management plan and the potential risks of the piping system. Therefore, in this study, research is intended to be carried out to allow efficient power plant operation, through optimization of the design of the piping system. The purpose of the study is to confirm economic feasibility by changing the piping loop design, expanding the length of pipe loops, and to investigate the thermal stress influence on the piping system through simulations of systems similar in condition to those currently used in existing plants in Korea.

소형 공정열교환기 시제품의 고온구조해석 (High-temperature Structural Analysis on the Small Scale PHE Prototype)

  • 송기남;이형연;홍성덕;박홍윤
    • 한국압력기기공학회 논문집
    • /
    • 제6권1호
    • /
    • pp.57-64
    • /
    • 2010
  • PHE(Process Heat Exchanger) is a key component required to transfer heat energy of $950^{\circ}C$ generated in a VHTR(Very High Temperature Reactor) to the chemical reaction that yields a large quantity of hydrogen. Korea Atomic Energy Research Institute established the gas loop for the performance test of components, which are used in the VHTR, and they manufactured a PHE prototype to be tested in the loop. In this study, as part of the high-temperature structural-integrity evaluation of the PHE prototype, which is scheduled to be tested in the gas loop, we carried out high-temperature structural-analysis modeling, thermal analysis, and thermal expansion analysis of the PHE prototype. The results obtained in this study will be used to design the performance test setup for the PHE prototype.

  • PDF

배관 강성을 고려한 소형 공정열교환기 시제품에 대한 탄성 고온구조해석 (Elastic High-temperature Structural Analysis on the Small Scale PHE Prototype Considering the Pipeline Stiffness)

  • 송기남;강지호;홍성덕;박홍윤
    • 한국압력기기공학회 논문집
    • /
    • 제7권3호
    • /
    • pp.48-53
    • /
    • 2011
  • A PHE (Process Heat Exchanger) is a key component required to transfer heat energy of $950^{\circ}C$ generated in a VHTR (Very High Temperature Reactor) to the chemical reaction that yields a large quantity of hydrogen. A small-scale PHE prototype made of Hastelloy-X is being tested in a small-scale gas loop at Korea Atomic Energy Research Institute. In this study, as a part of the evaluation on the high-temperature structural integrity of the small-scale PHE prototype, we carried out macroscopic high-temperature structural analysis of the small-scale PHE prototype under the gas loop test conditions considering the pipeline stiffness.

원전 배관의 반복 측정 데이터에 대한 신뢰도 분석 방법 (Reliability Analysis Method for Repeated UT Measurement Data in Nuclear Power Plants)

  • 윤훈;황경모
    • Corrosion Science and Technology
    • /
    • 제12권3호
    • /
    • pp.142-148
    • /
    • 2013
  • Safety is a major concern in Nuclear Power Plants (NPPs). Piping systems in NPPs are very complex and composed of many components such as tees, elbows, expanders and straight pipes. The high pressure and high temperature water flows inside piping components. As high speed water flows inside piping, the pipe wall thinning occurs in various reasons such as FAC (Flow Accelerated Corrosion), LDIE (Liquid Droplet Impingement Erosion) and Flashing. To inspect the wall thinning phenomenon and protect the piping from damages, piping components are checked by UT measurement in every overhaul. During every overhaul, approximately 200~300 components (40,000~60,000 UT data) are examined in NPPs. There are some methods from EPRI for evaluating wear rate of components. However, only few studies have been conducted to find out the raw data reliability for the wear rate evaluation. Securing the reliable raw data is the key factor for a reasonable evaluation. This paper suggests the reliability analysis method for the repeatedly measured data for wear rate evaluation.

소형가스루프 시험조건에서 소형 공정열교환기 시제품의 고온구조해석 (High-Temperature Structural Analysis on the Small-Scale PHE Prototype under the Test Condition of Small-Scale Gas Loop)

  • 송기남;홍성덕;박홍윤
    • 한국압력기기공학회 논문집
    • /
    • 제8권1호
    • /
    • pp.1-7
    • /
    • 2012
  • A PHE (Process Heat Exchanger) is a key component required to transfer heat energy of $950^{\circ}C$ generated in a VHTR (Very High Temperature Reactor) to the chemical reaction that yields a large quantity of hydrogen. A small-scale PHE prototype made of Hastelloy-X is being tested in a small-scale gas loop at Korea Atomic Energy Research Institute. In order to properly evaluate the high-temperature structural integrity of the small-scale PHE prototype, it is very important to impose a proper constraint condition on its structural analysis model. For this effort, we tried to impose several constraint conditions on the structural analysis model and consequently fixed a proper and effective displacement constraints.

용접물성치를 고려한 소형 공정열교환기 시제품의 고온구조해석 (High-Temperature Structural Analysis on the Small-Scale PHE Prototype using Weld Properties)

  • 송기남;홍성덕;박홍윤
    • 한국압력기기공학회 논문집
    • /
    • 제8권2호
    • /
    • pp.1-6
    • /
    • 2012
  • A PHE (Process Heat Exchanger) in a nuclear hydrogen system is a key component required to transfer heat energy of $950^{\circ}C$ generated in a VHTR (Very High Temperature gas cooled Reactor) to the chemical reaction that yields a large quantity of hydrogen. A small-scale PHE prototype made of Hastelloy-X is being tested in a small-scale gas loop at Korea Atomic Energy Research Institute. Previous research on the high-temperature structural analysis of the small-scale PHE prototype had been performed only using parent material properties. In this study, high-temperature structural analysis using weld properties in weld zone was performed and the analysis results compared with the previous research.

PGSFR중간열교환기의 정상상태 고온 구조 건전성 평가 (Evaluation of High Temperature Structural Integrity of Intermediate Heat Exchanger in a Steady State Condition for PGSFR)

  • 이성현;구경회;김성균
    • 한국압력기기공학회 논문집
    • /
    • 제12권1호
    • /
    • pp.107-114
    • /
    • 2016
  • Four cylindrically shaped IHXs(Intermediate Heat Exchangers) are installed in the PHTS(Primary Heat Transfer System) of the PGSFR(Prototype Gen IV Sodium cooled Fast Reactor). As for the IHX, the temperature difference of structure is inevitable result caused by heat transfer between primary coolant sodium and IHTS(Intermediate Heat Transport System) sodium. It is necessary to evaluate the high temperature structural integrity of IHXs which operate at the elevated temperature condition over the creep temperature. In this paper, the high temperature structural integrity of IHX under assumed loading conditions has been reviewed according to ASME code.

STELLA-2 소듐 시험 시설 고온 배관 계통의 설계 및 건전성 평가 (Design and Integrity Evaluation of High-temperature Piping Systems in the STELLA-2 Sodium Test Facility)

  • 손석권;이형연;주용선;어재혁;김종범;정지영
    • 대한기계학회논문집A
    • /
    • 제40권9호
    • /
    • pp.775-782
    • /
    • 2016
  • 본 연구에서는 한국원자력연구원이 개발 중인 소듐 열유동 종합효과 시험장치(STELLA-2)의 주요 배관 계통을 대상으로 고온 설계를 수행하고, 두 가지 설계기술기준에 따라 배관의 건전성 평가를 수행하였다. 배관 설계기술기준으로는 일반 압력배관에 관한 ASME B31.1과 프랑스의 원자력등급 배관 설계기술기준인 RCC-MRx RD-3600을 적용하였으며, 이들 기술기준의 보수성을 정량적으로 비교 및 분석하였다. STELLA-2 소듐시설에서는 모의 잔열제거계통(Model DHRS), 모의 중간열전달계통(Model IHTS) 및 펌프 모의계통(PSLS)에 배관이 설치되는데, 두 설계기술기준을 따라 이들 배관 계통에 대해 건전성 평가를 수행한 결과 설계 건전성이 확인되었으며, 설계 기술기준 간 비교분석 결과 유지하중에 대해서는 ASME B31.1이, 열하중에 대해서는 RCC-MRx RD-3600이 더 보수적인 것으로 평가되었다.

Type 316L 스테인리스강의 700℃ 열교환기에의 적용 방법론 (Application methodology of Type 316L stainless steel to a 700℃ heat exchanger)

  • 이형연;남기언;이윤승;어재혁
    • 한국압력기기공학회 논문집
    • /
    • 제20권1호
    • /
    • pp.75-83
    • /
    • 2024
  • In this study, high temperature design and integrity evaluation methodology have been developed for Type 316L stainless steel air-to-sodium heat exchanger which uses 700℃ sodium as coolant. Currently the only design rules that take creep effects into consideration explicitly for the 316L stainless steel subjected to high temperature in the creep range are French RCC-MRx, where elevated temperature designs are possible around 550℃. Absent design coefficients at high temperature were determined based on the material properties newly determined in previous studies, and high-temperature design evaluation methodologies were developed based on 3D finite element analyses on the 700℃ class heat exchanger. In addition, works were conducted on the web-based design evaluation program of HITEP_RCC-MRx including incorporation of material properties and design coefficients up to 700℃. Methodologies on high temperature design evaluations on Type 316L stainless steel high-temperature heat exchanger were suggested.

원자로 냉각재배관 엘보우 및 서포트 스컷트용 (Fracture Resistance Characteristics of SA516-Gr.70 Steel Plate for RCS Piping Elbow and Support Skirt)

  • 손종동;임만배
    • 한국안전학회지
    • /
    • 제21권4호
    • /
    • pp.49-54
    • /
    • 2006
  • The evaluation of elastic-plastic fracture characteristic was investigated in ferrite steel SA 516- Gr70 used for reactor coolant piping elbow and support skirt of pressure vessels. This paper describes the effect of temperature on J-R curve characteristic of this material. The elastic-plastic fracture mechanics parameter J is obtained with unloading compliance method. The test method were analyzed according to ASTM E 813-89 and E 1152-89. Unloading compliance $J_{IC}$ tests were performed on 1 CT specimens at varied temperatures from $25^{\circ}C$ to about $400^{\circ}C$ using a high temperature extensometer. At all temperature, valid $J_{IC}$ measurements could be made and $J_{IC}$ decreased with increasing temperature. SEM fractography schematically illustrates microvoid initiation, growth and coalescence at the tip of a preexisting crack.