• Title/Summary/Keyword: High-speed measuring device

Search Result 57, Processing Time 0.022 seconds

EVALUATION AND DEVELOPMENT OF DIGITAL DEVICE FOR MEASURING PROXIMAL TOOTH CONTACT TIGHTNESS (디지털 방식의 인접면 접촉강도 측정장치의 개발 및 평가)

  • Choi, Woo-Jin;Kim, Kyung-Hwa;Kim, Jin-A;Kang, Dong-Wan;Oh, Sang-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.5
    • /
    • pp.687-695
    • /
    • 2007
  • Statement of problem: The proper contact relation between adjacent teeth in each arch plays an important role in the stability and maintenance of the integrity of the dental arches. Proximal contact has been defined as the area of a tooth that is in close association, connection, or touch with an adjacent tooth in the same arch. Purpose: The aim of this study was to develop a digital device for measuring the proximal tooth contact tightness by pulling a thin stainless steel strip (2mm wide, 0.03mm thick) inserted between proximal tooth contact. Material and method: This device consists of measuring part, sensor part, motor part and body part. The stainless steel strip was connected to a stain gauge. The strain gauge was designed to convert the frictional force into a compressive force. This compressive force was detected as a electrical signal and the electrical signal was digitalized by a A/D converter. The digital signals were displayed by a micro-processor. The pulling speed was 8mm/s. Results: For testing reliability of the device in vivo, two healthy young adults (A, B) participated in this experiment. The tightness of proximal tooth contact between the second premolar and the first molar of mandible (subject A) and maxilla (subject B) was measured fifteen times for three days at rest. We double-checked the accuracy of the device with a Universal Testing Machine. Output signals from the Universal Testing Machine and the measuring device were compared. Regression analysis showed high linearity between these two signals. In vivo test, no significant differences were found between measurements. Conclusion: This device has shown to he capable of producing reliable and reproducible results in measuring proximal tooth contact. Therefore, it was considered that this device was appropriate to apply clinically.

Efficiency Characteristics of DC-DC Boost Converter Using GaN, Cool MOS, and SiC MOSFET (GaN, Cool MOS, SiC MOSFET을 이용한 DC-DC 승압 컨버터의 효율 특성)

  • Kim, Jeong Gyu;Yang, Oh
    • Journal of the Semiconductor & Display Technology
    • /
    • v.16 no.2
    • /
    • pp.49-54
    • /
    • 2017
  • In this paper, recent researches on new and renewable energy have been conducted due to problems such as energy exhaustion and environmental pollution, and new researches on high efficiency and high speed switching are needed. Therefore, we compared the efficiency by using high speed switching devices instead of IGBT which can't be used in high speed switching. The experiment was performed theoretically by applying the same parameters of the high speed switching devices which are the Cool MOS of Infineon Co., SiC C3M of Cree, and GaN FET device of Transform, by implementing the DC-DC boost converter and measuring the actual efficiency for output power and frequency. As a result, the GaN FET showed good efficiency at all switching frequency and output power.

  • PDF

Verification of High Speed Performance for the Electronic Pedal using a Rotor (회전체를 이용한 전자페달의 고속 성능 검증)

  • KIM, Yong-Kyu;GO, Jun-Young;YOON, Yong-Ki;KIM, Ju-Yeop;LEE, Jong-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.8
    • /
    • pp.1450-1456
    • /
    • 2016
  • In this paper, we have checked a method of performance evaluation for electronic pedal, which is a core technology of HBD for detecting the axle temperature of high-speed train. As it is practically impossible to conduct train speed test of 500 km/h, we utilize a high speed rotor for evaluating high speed performance of the electronic pedal instead. According to this method, we found that the measurement results by the velocity measuring instrument is similar with the ones from this research through the high speed rotor. In conclusion, it will be possible to conduct reliability evaluation for high speed performance for Beacon, Balise and RFID, which are utilized for transmitting vital information of train control systems through using the rotor.

Evaluation of Ergonomic Performance of Medical Smart Insoles

  • Yi, Jae-Hoon;Lee, Jin-Wook;Seo, Dong-Kwon
    • Physical Therapy Rehabilitation Science
    • /
    • v.11 no.2
    • /
    • pp.215-223
    • /
    • 2022
  • Objective: This study was to resolve the limitations of the experimental environment and to solve the shortcomings of the method of measuring human gait characteristics using optical measuring instruments. Design: A cross-sectional study. Methods: Fifteen healthy adults without a history of orthopedic surgery on the lower extremities for the past 6 months were participated. They were analyzed gait variables using the smart guide and the 3D image analysis at the same time, and their results were compared. Visual-3D was used to calculate the analysis variables. Results: The reliability and validity of the data according to the two measuring instruments were found to be very high; gait speed(0.85), cycle time(0.99), stride time of both feet(0.98, 0.97) stride legnth of both feet(0.86, 0.88) stride per minute of both feet(0.99, 0.96), foot speed of both feet(0.90, 0.91), step time of both feet(0.77, 0.71), step per minute(0.72, 0.74), stance time of both feet(0.96, 0.97), swing time of both feet(0.93, 0.79), double step time(0.81), initial double step time(0.84) and terminal step time(0.76). Conclusions: In the case of the smart insole, which measures human gait variables using the pressure sensor and inertial sensor inserted in the insole, the reliability and validity of the measured data were found to be very high. It can be used as a device to replace 3D image analysis when measuring pathological gait.

Measurement of Archer's Paradox Size using Multiple Frames (다중프레임을 이용한 궁사의 패러독스 크기 측정)

  • Kim, Jonggeun;Jeong, Yeongsang;Song, Moonjae;Kim, Sungshin
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.1
    • /
    • pp.21-26
    • /
    • 2014
  • An arrow produced by a manufacturing process is evaluated using the archer's paradox and the intensity of the impact point. The accuracy rate in particular is changed by the arrow's vibrational movement, which is called the archer's paradox. The archer's paradox occurs not only in the right, left, upward, and downward directions, but in all directions. The optimized value of the archer's paradox has not been studied yet. This paper proposes to measure the archer's paradox to determine its optimized value. Measuring the archer's paradox using a high-speed camera is expensive, and it is difficult to translate the result to a numerical value. However, the device for measuring the archer's paradox proposed in this paper is inexpensive, and the results are easy to convert to a numerical value. Therefore, this device is more suitable for optimization of the archer's paradox than a high-speed camera. In this paper, we propose to measure the size of the paradox using multiple frames, which can measure the position of an arrow moving at a speed of 300km/h to within millimeters. We calculate the size of the paradox experimentally using the measured location in each frame. This value is not an approximate value, but an accurate numerical value.

Dynamic Fracture Behavior of Some Polymeric Materials (고분자재료의 동적 파괴거동에 관한 연구)

  • 이억섭;한정우;한문식
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.7
    • /
    • pp.1630-1641
    • /
    • 1995
  • The dynamic stress intensity factors (DSIF ; $K_{I}$$^{dyn}$) were studied in some polymeric materials using caustics method with a high speed camera system. Also crack tip propagation speed was measured by dynamic crack propagation velocity measuring device. To calculate DSIF a finite element analysis program-INha Stress Analysis Moving CRack(INSAMCR) was utilized. Dynamic fracture characteristics were investigated to verify a relationship between DSIF and crack tip propagation speed and acceleration in PMMA, Homalite-100 and Polycarbonate. The relationship between dynamic stress intensity factor and crack tip velocity revealed typical shapes. Measured crack tip acceleration data envelope converges to the zero level with increasing DSIF. Equivalently crack tip velocities show a wide spread range at low values of DSIF, but become a constant with a higher DSIF. $1.2MPa{\sqrt{m}}$, $1.4MPa{\sqrt{m}}$ and $1.3 MPa{\sqrt{m}}$ were obtained as $K_{I}$$^{dyn}$ values to arrest the dynamic crack for PMMA, Homalite-100 and Polycarbonate, respectively. INSAMCR was run to verify experimental results in PMMA and shows good agreementment.

Sunroof Wind Noise Reduction Using Automatic Noise Measurement and Analysis System (자동 소음 계측 및 분석 장치를 이용한 자동차 썬루프 윈드노이즈 저감 기술 개발)

  • Shin, Seong-Ryong;Kim, Heung-Ki;Jung, Seung-Gyoon;Kook, Hyung-Seok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11b
    • /
    • pp.166-169
    • /
    • 2005
  • The best sunroof wind noise quality is mainly related to the sunroof deflector which affects both low-speed buffeting and high-speed aerodynamic noise. An automatic deflector-moving and noise-measuring apparatus is developed to obtain hundreds of measuring data which haven't been available by hand. With an additional program for fast and easy noise analysis, this device leads quickly to the better position and angle of the deflector. Now, the 'better' means the lower noise level and the robuster design solution. From these kinds of better solutions, more meaningful guidelines on the deflector design and sunroof wind noise reduction can be suggested.

  • PDF

Optimum Design of a Liquid Film Thickness Measurement Device Using Electric Conductance for Impingement Liquid Film (충돌 액막 분석을 위한 전기전도 액막 두께 측정장치 최적설계)

  • Lee, Hyeongwon;Lee, Hyunchang;Kim, Taesung;Ahn, Kyubok;Yoon, Youngbin
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.6
    • /
    • pp.386-391
    • /
    • 2018
  • To analyze the film cooling in a liquid rocket engine, it is necessary to understand the characteristics of the wall-impingement liquid film. We designed an optimal two-dimensional device for measuring the thickness of the liquid film thickness. This device quantitatively measures the liquid-film thickness distribution. In previous liquid-film thickness measuring devices, the liquid film was formed over the entire area of the sensor. However, its formation depended on injection conditions. To compensate for this, optimal resistors are selected. Additionally, saturation variations with partial saturation are analyzed. Furthermore, calibration using the enhanced plate method is conducted with improvements in spatial resolution. The device designed here can be used to analyze the properties of an impingement liquid film with a slit injector. This study can be used for film-cooling analysis in liquid rocket engines.

A Stereo Image Recognition-Based Method for measuring the volume of 3D Object (스테레오 영상 인식에 기반한 3D 물체의 부피계측방법)

  • Jeong, Yun-Su;Lee, Hae-Won;Kim, Jin-Seok;Won, Jong-Un
    • The KIPS Transactions:PartB
    • /
    • v.9B no.2
    • /
    • pp.237-244
    • /
    • 2002
  • In this paper, we propose a stereo image recognition-based method for measuring the volume of the rectangular parallelepiped. The method measures the volume from two images captured with two CCD (charge coupled device) cameras by sequential processes such as ROI (region of interest) extraction, feature extraction, and stereo matching-based vortex recognition. The proposed method makes it possible to measure the volume of the 3D object at high speed because only a few features are used in the process of stereo matching. From experimental results, it is demonstrated that this method is very effective for measuring the volume of the rectangular parallelepiped at high speed.

A study on the inspection algorithm of FIC device in chip mounter (칩 마운터에의 FIC 부품 인식에 관한 연구)

  • Lyou, Kyoung;Moon, Yun-Shik;Kim, Kyoung-Min;Park, Gwi-Tae
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.4 no.3
    • /
    • pp.384-391
    • /
    • 1998
  • When a device is mounted on the PCB, it is impossible to have zero defects due to many unpredictable problems. Among these problems, devices with bent corner leads due to mis-handling and which are not placed at a given point measured along the axis are principal problem in SMT(Surface Mounting Technology). It is obvious that given the complexity of the inspection task, the efficiency of a human inspection is questionable. Thus, new technologies for inspection of SMD(Surface Mounting Device) should be explored. An example of such technologies is the Automated Visual Inspection(AVI), wherein the vision system plays a key role to correct this problem. In implementing vision system, high-speed and high-precision are indispensable for practical purposes. In this paper, a new algorithm based on the Radon transform which uses a projection technique to inspect the FIC(Flat Integrated Circuit) device is proposed. The proposed algorithm is compared with other algorithms by measuring the position error(center and angle) and the processing time for the device image, characterized by line scan camera.

  • PDF