• Title/Summary/Keyword: High-rise Building

Search Result 1,780, Processing Time 0.029 seconds

A Study on the Circulation Planning of Multi Shopping Mall with User Evaluation (사용자 평가를 통한 복합쇼핑몰 동선 계획 연구)

  • Kim, Ji Soo;Hwang, Yeon Sook
    • Design Convergence Study
    • /
    • v.15 no.5
    • /
    • pp.55-70
    • /
    • 2016
  • Multi shopping malls provide us new life-style nowadays with the term, malling. Multi shopping malls are consisted of selling space, entertainment space and convenience space so that arrangement and circulation planning of each facilities have large influence to users. Based on this influences, this study aims to provide basic data for multi shopping malls' circulation planning. Therefore, this study selected 6 multi shopping malls in Seoul and conducted survey that satisfaction of circulation planning of multi shopping malls. For user satisfaction investigation, we studied concept of multi shopping mall following Korean building act and selected composition and characteristics of circulation. Also, we classified the malls to size and circulation shapes for comparison of the satisfaction results. Classified types are high-rise and low-rise and they are separated to small size and big size. In addition, classified circulation shapes are categorized to net type, loop type, cyclical loop type and multi type by forms of central space and main stream of the malls.

Local Buckling of Built-up Square Tubular Compression Members Fabricated with HSA800 High Performance Steels under Concentric Axial Loading (중심압축력을 받는 건축구조용 고성능강(HSA800) 용접 각형강관 압축재의 국부좌굴)

  • Yoo, Jung-Han;Kim, Joo-Woo;Yang, Jae-Keun;Kang, Joo-Won;Lee, Dong-Woo
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.4
    • /
    • pp.435-442
    • /
    • 2012
  • Recently, high performance(strength) steels have been utilized to structural materials in buildings and bridges with the demand for high-rise and long-span of main structures. This paper is a series of basic study for the design specification of structural members using high performance steel, material properties of high performance rolled steel building structures. HSA800 was compared with the requirements of Korean Standards(KS) for HSA800. Welded square tube stub columns with variables of width-to-thickness ratios are planned in order to investigate the local buckling behaviors and check the current design limit of width-to-thickness ratio and uniaxial compressive tests are carried out. In addition, the local buckling behaviors of stub columns obtained finite element analysis were compared with those of test results.

A Study on Compressive Strength of Built-up H Shaped Columns Fabricated with HSA800 High Performance Steels (건축구조용 고성능강(HSA800) 용접 H형단면 기둥의 압축강도에 관한 연구)

  • Kim, Tae Soo;Lee, Myung Jae;Oh, Young Suk;Lee, Kang Min;Kim, Do Hwan
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.6
    • /
    • pp.627-636
    • /
    • 2012
  • Recently, high performance(strength) steels have been utilized to structural materials in buildings and bridges with the demand for high-rise and long-span of main structures. This paper is a series of basic study for the design specification of structural members using high performance steel, material properties of high performance rolled steel building structures; material properties of HSA800 steel was compared with the requirements of Korean Standards(KS) for HSA800. Welded H-shape stub columns with variables of width-to-thickness ratios are planned in order to investigate the local buckling behaviors and check the current design limit of width-to-thickness ratio and uniaxial compressive tests are carried out. In addition, the buckling behaviors of stub columns obtained finite element analysis were compared with those of test results.

An Experimental Study on the Structural Behavior of Stub Columns with HSA800 High-strength Steels under Eccentric Loads (편심하중을 받는 건축구조용 고강도 강재(HSA800) 단주의 거동에 관한 실험적 연구)

  • Lee, Kangmin;Lee, Myung Jae;Oh, Young Suk;Oh, Keunyeong;Hong, Sungbin
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.4
    • /
    • pp.289-297
    • /
    • 2014
  • Recently, high performance steels have been utilized to structural materials in buildings and bridges with the demand for high-rise and long-span of main structures. In this paper, flexure-compression members with the high-strength steel were experimentally evaluated to satisfy the design criteria when stub columns fabricated with HSA800 steel were eccentrically loaded. This test was conducted on box-shaped and H-shaped steels stub columns with high-strength steel to verify the P-M interaction of members subjected to combined forces according to axial load ratios. The results showed that all specimens were satisfied the requirements of Korean Building Code(KBC2009) for using of structural members.

Mixing and Strength Properties of 150MPa Ultra High Strength Concrete (150MPa 초고강도 콘크리트 배합 및 강도발현 특성)

  • Ahn, Jong-Mun;Kang, Hoon;Kim, Jong-Keun;Shin, Sung-Woo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.373-376
    • /
    • 2008
  • Ultra High Strength Concrete(UHSC) is necessary a clear presentation about mechanical property that is different from normal strength concrete and an evaluation of serviceability of high rise building which is used ultra high strength concrete. To mixing ultra high strength concrete with $f_{ck}$=150MPa pre-mix cement were manufactured and experimental study were conducted to evaluated on the mixing properties and compressive strength with major variables as unit cement contents, water-binder ratio and type of pre-mix cement. As a test result, it is shown that the concrete mixing time is required about 5$^{\sim}$6 minute untill the each materials(ordinary portland cement, silica fume, blast-furnace slag powder and anhydrite) are revitalized enough. A slump flow of fresh concrete are shown about 700$^{\sim}$750mm with proper viscosity. And average value of concrete compressive strength are shown about 77% in 7days, 87% in 14days and 102% in 56days for 28days of concrete material age. From this experimental study, a proper mixture proportion of pre-mix cement are recommended about 54$^{\sim}$59% OPC, 25$^{\sim}$30% blast-furnace slag powder and 10$^{\sim}$15% silica fume for mix the ultra high strength concrete with $f_{ck}$=150MPa.

  • PDF

Structural Design And Analysis of Haeundae Doosan We've The Zenith (해운대 두산 위브 더 제니스 구조설계)

  • Park, Ki-Hong;Park, Suk-Jin
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2008.11a
    • /
    • pp.93-98
    • /
    • 2008
  • Haeundae Doosan We've The Zenith project is adjacent to Suyoung-bay, now it is in the process of excavation and foundation work. The main use of the tower is residence which height is 300m and 80 floor, the highest residential reinforced concrete building through the Orient. It is comprised of 3 high- rised buildings and 1 low-rised building, the basement is 230m wide and 200m length sized mass structure. The lateral resistance system is acted effectively against the lateral load and satisfactorily against the wind vibration by the 4 direction extension of the center core wall($700{\sim}800mm$ thickness) and reinforced concrete column set around the slab. Flat-plate slab system(250mm thickness) is adjusted for the slab system and it enables effective work process and shortening the working term by minimizing the ceiling height and not needing to install perimeter beam and drop panel. The strength and serviceability of the structure is able to be monitored and estimated constantly through the health monitoring system during the construction and after the construction.

  • PDF

A Study on the Construction of Indoor Spatial Information using a Terrestrial LiDAR (지상라이다를 이용한 지하철 역사의 3D 실내공간정보 구축방안 연구)

  • Go, Jong Sik;Jeong, In Hun;Shin, Han Sup;Choi, Yun Soo;Cho, Seong Kil
    • Spatial Information Research
    • /
    • v.21 no.3
    • /
    • pp.89-101
    • /
    • 2013
  • Recently, importance of indoor space is on the rise, as larger and more complex buildings are taking place due to development of building technology. Accordingly, range of the target area of spatial information service is rapidly expanding from outdoor space to indoor space. Various demands for indoor spatial information are expected to be created in the future through development of high technologies such as IT Mobile and convergence with various area. Thus this research takes a look at available methods for building indoor spatial information and then builds high accuracy three-dimensional indoor spatial information using indoor high accuracy laser survey and 3D vector process technique. The accuracy of built 3D indoor model is evaluated by overlap analysis method refer to a digital map, and the result showed that it could guarantee its positional accuracy within 0.04m on the x-axis, 0.06m on the y-axis. This result could be used as a fundamental data for building indoor spatial data and for integrated use of indoor and outdoor spatial information.

A Study on the POE (Post Occupancy Evaluation) according to the Residential Environment of Mixed-use Apartment Complexes In Seoul

  • Ha, Man Joon
    • International Journal of High-Rise Buildings
    • /
    • v.9 no.2
    • /
    • pp.197-212
    • /
    • 2020
  • In this study, POE(Post Occupancy Evaluation) evaluation indexes were selected into six categories through the consideration of theories and prior research. Therefore, qualitative supply can be achieved through POE according to the aspect of residential environment after the quantitative supply of mixed-use apartment complex by the population concentration in Seoul due to industrialization and urbanization. As the evaluation elements, detailed survey contents were selected for livability, convenience, comfort, safety, economy, and sociality. Based on the survey contents, six elements were evaluated and analyzed using Data coding and Likert scale after surveying 12 complexes (Urban areas and non-urban areas) in Seoul. As a result of the study, six categories selected as the POE showed that importance of quality of life and safety was developed in high recognition according to high satisfaction with convenience and safety. Sociality showed the lowest satisfaction in the following order : livability, comfort, economy and sociality. Residents' sense of community, interaction with neighborhood, etc., showed low satisfaction, and it seems that it is necessary to improve and supplement the system for the development of mixed-use apartment complex in the future. The detailed characteristics of livability showed high satisfaction of the living room, the front door and the main room which are main uses of housing, and low satisfaction in storage size. The analysis of convenience is that convenient public transportation was the highest, and educational environment and additional facilities were the lowest, showing the advantages and disadvantages of location characteristics. As a result of the analysis of comfort, satisfaction with the landscape area was low and it seems that green space is needed for the development of mixed-use apartment complex in the future. Lastly, regarding the safety, the satisfaction of the access control, the location of security office, etc. were high, however separation of circulation was low. Therefore, it is necessary to clearly separate the circulation between the residence and other facilities in the mixed-use apartment complex.

A Study on the Effects of All-in-one Automatic Fire Shutters Installed in High School on Evacuation Time

  • Lee, Soon Beom;Kong, Ha Sung;Lee, Jai Young
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.14 no.3
    • /
    • pp.182-192
    • /
    • 2022
  • This study analyzed the effects of the all-in-one automatic fire shutter (hereinafter referred to as "all-in-one shutter") installed along the fire compartment in a five-story high school building on the evacuation time by using the Pathfinder simulation program. When the all-in-one shutter was added as a new variable, the evacuation time was delayed, indicating insufficient evacuation safety. The evacuation time exceeded the appropriate standard when the evacuation exit was designated to the students in the present state of being placed on the 2nd, 3rd, and 4th floors and the all-in-one shutter was activated. When students were placed on the 1st, 2nd and 3rd floors under the same conditions, the evacuation time was also greatly exceeded. However, when the width of the entrance was set to 130cm, the evacuation time was almost the same as when the all-in-one shutter was not installed. In high-rise school buildings, the bottleneck caused by all-in-one shutters is becoming a major factor in evacuation barriers. To ensure the evacuation safety of school buildings, it has been judged that evacuation education and training to predict the evacuation time required through the all-in-one shutter entrance and induce an evacuation procedure suitable for the standard evacuation time should be carried out in parallel. The implications of this study and suggestions for effective fire compartments and follow-up studies were discussed.

A Study on security characteristics and vulnerabilities of BAS(Building Automation System) (BAS의 보안 특성 및 취약점에 관한 연구)

  • Choi, Yeon-Suk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.4
    • /
    • pp.669-676
    • /
    • 2017
  • Recently, due to the importance of information security, security vulnerability analysis and various information protection technologies and security systems are being introduced as a countermeasure against cyber-attacks in new as well as existing buildings, and information security studies on high-rise buildings are also being conducted. However, security system introduction and research are generally performed from the viewpoint of general IT systems and security policies, so there is little consideration of the infrastructure of the building. In particular, the BAS or building infrastructure, is a closed system, unlike typical IT systems, but has unique structural features that accommodate open functions. Insufficient understanding of these system structures and functions when establishing a building security policy makes the information security policies for the BAS vulnerable and increases the likelihood that all of the components of the building will be exposed to malicious cyber-attacks via the BAS. In this paper, we propose an architecture reference model that integrates three different levels of BAS structure (from?) different vendors. The architectures derived from this study and the security characteristics and vulnerabilities at each level will contribute to the establishment of security policies that reflect the characteristics of the BAS and the improvement of the safety management of buildings.